Operational specifications of the laser illuminated track etch scattering dosemeter reader.

The personnel dosimetry operations team at the Los Alamos National Laboratory (LANL) has accepted the laser illuminated track etch scattering (LITES) dosemeter reader into its suite of radiation dose measurement instruments. The LITES instrument transmits coherent light from a He-Ne laser through the pertinent track etch foil and a photodiode measures the amount of light scattered by the etched tracks. A small beam stop blocks the main laser light, while a lens refocuses the scattered light into the photodiode. Three stepper motors in the current LITES system are used to position a carousel that holds 36 track etch dosemeters (TEDs). Preliminary work with the LITES system demonstrated the device had a linear response in counting foils subjected to exposures up to 50 mSv (5.0 rem). The United States Department of Energy requires that the annual general employee dose not exceed 50 mSv (5.0 rem). On a regular basis, LANL uses the Autoscan-60 reader system (Thermo Electron Corp.) for counting track etch dosemeters. However, LANL uses a 15 h etch process for CR-39 dosemeters, and this produces more and larger track etch pits than the 6 h etch used by many institutions. Therefore, LANL only uses the Autoscan-60 for measuring neutron dose equivalent up to exposure levels of approximately 3 mSv (300 mrem). The LITES system has a measured lower limit of detection of approximately 0.6 mSv (60 mrem), and it has a correlation coefficient of R (2) = 0.99 over an exposure range up to 500 mSv (50.0 rem). A series of blind studies were done using three methods: the Autoscan-60 system, manual counting by optical microscope and the LITES instrument. A collection of track etch dosemeters of unknown neutron dose equivalent (NDE) were analysed using the three methods, and the performance coefficient (PC) was calculated when the NDE became known. The Autoscan-60 and optical microscope methods had a combined PC = 0.171, and the LITES instrument had a PC = 0.194, where a PC less than or equal to 0.300 is considered satisfactory.

Dose-Response Relationship, Radiation↗

Monte Carlo modelling of a simple accident dosemeter.

A simple dosemeter made of a sulphur tablet, bare and cadmium-covered indium foils and a cadmium-covered copper foil has been modelled using MCNP5. Studies of the model without phantoms or other confounding factors have shown that the cross sections and fluence-to-dose factors generated by the Monte Carlo method agree with those generated by analytic expressions for the high-energy component. In this study, the effect of location on phantoms is studied and an extension of this study to low and intermediate energies is done. The activities expected from exposure to four critical assemblies on phantom is calculated and compared with observations.

Computer Simulation↗

Monte Carlo modelling of a simple accident dosemeter.

A simple dosemeter made of a sulphur tablet, bare and cadmium-covered indium foils and a cadmium-covered copper foil has been modelled using MCNP5. Studies of the model without phantom or other confounding factors have shown that the cross sections and fluence-to-dose factors generated by the Monte Carlo method agree with those generated by analytic expressions for the high energy component. In this study, a comparison of the effect of location on phantoms and an extension to low and intermediate energies is done. The activities expected from exposure to four critical assemblies on phantom is calculated and compared with observations.

Computer Simulation↗

Using operational equipment to read accident dosemeters.

Analysis of accident dosemeters usually involves the use of laboratory-based counting equipment. Gamma spectrometers are used for indium, copper and gold, and alpha-beta detectors for sulphur. This equipment is usually not easily transported due to the shielding required and the weight and delicacy of the counters. For intercomparison studies that require reading the dosemeters on site, a transportable system is required unless the site operating the study can count samples for all the participants. In the case of an actual accident these systems would have a difficulty in counting a large number of accident dosemeters. In an accident, personnel are usually subdivided according to their level of exposure. Those exposed to higher doses are treated immediately. An alternate system should be made available to handle the dosemeters worn by those personnel are likely to receive lower doses. Improvements in portable operational equipment for gamma and beta monitoring allow their use as spectrometers. Such a system was used for the SILENE intercomparison conducted at IRSN Valduc on 12 June and 19, 2002, and the preliminary results compared well with the other participants.

Equipment Failure Analysis↗

Multisphere default spectra--solution spectrum and dosemeter response implications.

Initial calibration of a multisphere spectroscopy system has been completed at Los Alamos National Laboratory using four standard calibration scenarios. Spectrum unfolding was performed using three methods of constructing the default spectrum: simple parameter models, Monte Carlo calculations and physical measurement. Comparisons of the resulting spectra for each solution method are presented. Implications of the spectral solutions upon dosemeter characterisation are addressed.

Algorithms↗

Computation of cross sections and dose conversion factors for criticality accident dosimetry.

In the application of criticality accident dosemeters the cross sections and fluence-to-dose conversion factors have to be computed. The cross section and fluence-to-dose conversion factor for the thermal and epi-thermal contributions to neutron dose are well documented; for higher energy regions (>100 keV) these depend on the spectrum assumed. Fluence is determined using threshold detectors. The cross sections require the folding of an expected spectrum with the reaction cross sections. The fluence-to-dose conversion factors also require a similar computation. The true and effective thresholds are used to include the information on the expected spectrum. The spectra can either be taken from compendia or measured at the facility at which the exposures are to be expected. The cross sections can be taken from data computations or analytic representations and the fluence-to-dose conversion factors are determined by various standards making bodies. The problem remaining is the method of computation. The purpose of this paper is to compare two methods for computing these factors: analytic and Monte Carlo.

Algorithms↗

Laser illuminated etched track scattering (LITES) dosimetry system.

Los Alamos National Labs (LANL) has developed an etched track foil (CR-39) reader for neutron dose between 0 and 50.0 mSv. Currently, the US Department of Energy mandates general employee annual exposure not to exceed 50.0 mSv (5 rem). At LANL, due to a non-linear response at higher exposures. accepted practice only uses an Autoscan 60 system up to 3 mSv. The LITES system, however, has demonstrated linear response to 50 mSv, where the proprietary design measures the amount of laser light scattered by the etched tracks, proportional to dose. A collection of calibrated foils was counted by an Autoscan 60 and the LITES prototype, and the Autoscan 60 showed good linearity when counting exposure up to about 15 mSv, but not for higher exposures. From 0 to 50 mSv, the Autoscan 60 had a correlation coefficient of R2 = 0.941 and the LITES system had R2 = 0.991.

Animals↗

WENDI: an improved neutron rem meter.

Neutron rem meters are routinely used for real-time field measurements of neutron dose equivalent where neutron spectra are unknown or poorly characterized. These meters are designed so that their response per unit fluence approximates an appropriate fluence-to-dose conversion function. Typically, a polyethylene moderator assembly surrounds a thermal neutron detector, such as a BF3 counter tube. Internal absorbers may also be used to further fine-tune the detector response to the shape of the desired fluence conversion function. Historical designs suffer from a number of limitations. Accuracy for some designs is poor at intermediate energies (50 keV-250 keV) critical for nuclear power plant dosimetry. The well-known Andersson-Braun design suffers from angular dependence because of its lack of spherical symmetry. Furthermore, all models using a pure polyethylene moderator have no useful high-energy response, which makes them inaccurate around high-energy accelerator facilities. This paper describes two new neutron rem meter designs with improved accuracy over the energy range from thermal to 5 GeV. The Wide Energy Neutron Detection Instrument (WENDI) makes use of both neutron generation and absorption to contour the detector response function. Tungsten or tungsten carbide (WC) powder is added to a polyethylene moderator with the expressed purpose of generating spallation neutrons in tungsten nuclei and thus enhance the high-energy response of the meter beyond 8 MeV. Tungsten's absorption resonance structure below several keV was also found to be useful in contouring the meter's response function. The WENDI rem meters were designed and optimized using the Los Alamos Monte Carlo codes MCNP, MCNPX, and LAHET. A first generation prototype (WENDI-I) was built in 1995 and its testing was completed in 1996. This design placed a BF3 counter in the center of a spherical moderator assembly, whose outer shell consisted of 30% by weight WC in a matrix of polyethylene. A borated silicone rubber (5% boron by weight) absorber covered an inner polyethylene sphere to control the meter's response at intermediate energies. A second generation design (WENDI-II) was finalized and tested in 1999. It further extended the high-energy response beyond 20 MeV, increased sensitivity, and greatly facilitated the manufacturing process. A 3He counter tube is located in the center of a cylindrical polyethylene moderator assembly. Tungsten powder surrounds the counter tube at an inner radius of 4 cm and performs the double duty of neutron generation above 8 MeV and absorption below several keV. WENDI-II is suitable for field use as a portable rem meter in a variety of work place environments, and has been recently commercialized under license by Eberline Instruments, Inc. and Ludlum Measurements, Inc. Sensitivity is about a factor of 12 higher than that of the Hankins Modified Sphere (Eberline NRD meter) in a bare 252Cf field. Additionally, the energy response for WENDI-II closely follows the contour of the Ambient Dose Equivalent per unit fluence function [H'(10)/phi] above 0.1 MeV. Its energy response at 500 MeV is approximately 15 times higher than that of the Hankins and Andersson-Braun meters. Measurements of the energy and directional response of the improved meter are presented and the measured response function is shown to agree closely with the predictions of the Monte Carlo simulations in the range from 0.144 MeV to 19 MeV.