PubMed Health⌕ Search

Biomedical subjects

R T Klann

Publications and source records attributed to R T Klann.

2 recordsLinked to original sources

Testing shields in the Argonne National Laboratory fuel conditioning facility support areas.

Testing has been completed for two lightly shielded areas that support operations in the Fuel Conditioning Facility at the Argonne National Laboratory site at the Idaho National Engineering Laboratory. Operational requirements dictated the use of a radiography source containing 0.44 TBq (12 Ci) of 192Ir to challenge reinforced concrete and steel shields that surround a decontamination, maintenance, and repair area for contaminated equipment used in hot cell operations. A more intense source containing 0.89 TBq (24 Ci) of 192Ir was used to test lead shot and steel shields around tanks in a radioactive liquid waste system and the boundaries of the room that contained it. Measurement procedures were developed to find design flaws and construction deficiencies while minimizing radiation exposure to test participants. While the shields are adequate to limit gamma ray deep dose equivalents to 10 mSv y(-1) (1 rem y(-1)) or less to facility personnel, several modifications were necessary to assure that the attenuation is adequate to keep dose rates less than 5 microSv h(-1) (0.5 mrem h(-1)) in normally occupied areas.

Decontamination↗

Testing hot cell shielding in the fuel conditioning facility.

A comprehensive shield test program for a hot cell complex, the Fuel Conditioning Facility at Argonne National Laboratory, has been completed with minimum radiation exposure to participants. The recently modified shielding design for two hot cells and their associated transfer paths for irradiated materials was analyzed and tested for attenuating gamma rays from mixed fission product sources. Testing was accomplished using 0.37 TBq (10 Ci) and 518 TBq (14,000 Ci) 60Co sources. Of specific concern were radiation levels around wall penetrations and the interface between transport casks and the cell floor. Detailed measurements were made for surfaces that bound the hot cells, a transfer tunnel between the two cells, and storage pits that extend below the floors of both cells. In addition to surface measurements, dose equivalent rates in adjacent corridors were determined when the larger source was exposed. Results indicate that with some administrative controls, the facility shields are adequate to meet the design criterion that limits annual dose to less than 10 mSv (1 rem) for facility workers.

Cobalt Radioisotopes↗