Concentrated autologous plasma protein: a biochemically neutral solder for tissue welding.

BACKGROUND AND OBJECTIVE: Xenographic or allographic serum protein solders used for laser welding may have immunologic and/or pathogenic complications. The objective of these studies was to develop a safe, autologous solder. STUDY DESIGN/MATERIALS AND METHODS: Five methods of preparing concentrated autologous plasma protein solder (CAPPS) were evaluated. Next, the CAPPS was evaluated via (1) thermal denaturation studies using differential scanning calorimetry, (2) tissue welding studies to characterize both acute and healing properties. RESULTS: The optimal concentration method to produce CAPPS rapidly was a dialysis method using chemical (osmotic) forces. The CAPPS showed similar denaturation profiles to serum albumin (SA) solders. Acutely, CAPPS provided comparable breaking strengths to SA solders. At 7 days, there was no significant difference in breaking strength or histology between 50% human SA solder and CAPPS (using a porcine skin model). CONCLUSIONS: These studies demonstrate that the CAPPS system provides acceptable acute and chronic properties for laser welding.

Animals↗

Differential scanning calorimetry of albumin solders: interspecies differences and fatty acid binding effects on protein denaturation.

BACKGROUND AND OBJECTIVE: Understanding albumin solder denaturation is important for laser tissue soldering. Human (HSA), bovine (BSA), porcine (PSA), and canine (CSA) albumin both fatty acid containing (FAC) and fatty acid free (FAF) were evaluated by using differential scanning calorimetry (DSC). STUDY DESIGN/MATERIALS AND METHODS: DSC was used to measure difference thermograms to determine the irreversible thermal denaturation profile for 50% albumin solutions. The denaturation transition's onset, end and peak temperatures, and enthalpy were measured. RESULTS: All FAC species, except BSA, exhibited twin peaked endotherms. Single endotherms were observed for all FAF species and BSA-FAC. Onset and end temperatures were significantly [P < 0.001] lower for all FAF species (except BSA's end temperature). There was a 30% decrease in the denaturation enthalpy between FAF and FAC groups. CONCLUSION: FAF albumin solders were found to denature at significantly lower temperatures, while also having a 30% reduction in enthalpy when compared with their FAC counterparts.

Animals↗

Heart booster: a pericardial support device.

BACKGROUND: Congestive heart failure is a pervasive disease afflicting millions of people. For many, their quality of life can be significantly improved by a pericardial device that can enhance cardiac output without the added risk of thromboembolism associated with direct blood contact. METHODS: A cardiac assist device with tubular elements is wrapped around the heart. Fluid is pumped into and out of the wrap causing contraction and dilation of its circumference. This contracting and relaxing action generates cardiac assistance without the need to contact blood. In vitro characterization and in vivo studies in calves were conducted to demonstrate the characteristics of the device. RESULTS: In vitro characterization with the device wrapped around one-half of a ventricle to simulate left ventricular support demonstrated outputs of 6.5 L/min at physiological afterloads. In vivo studies in calves demonstrated both cardiac output and afterload enhancements when the device is activated. CONCLUSIONS: This study provides a first demonstration of a device that provides cardiac support by a contraction and relaxation scheme with the device wrapped around the epicardium of the heart. The main feature of this actuation method is the potential for building a small device for implantation without blood contact.

Animals↗

Long-term mechanical circulatory support system reliability recommendation: American Society for Artificial Internal Organs and The Society of Thoracic Surgeons: long-term mechanical circulatory support system reliability recommendation.

Jointly developed by members of the American Society for Artificial Internal Organs and the Society of Thoracic Surgeons along with staff from the Food and Drug Administration, the National Heart, Lung and Blood Institute and other experts, this recommendation describes the reliability considerations and goals for Investigational Device Exemption and Premarket Approval submissions for long-term, mechanical circulatory support systems. The recommendation includes a definition of system failure, a discussion of an appropriate reliability model, a suggested in vitro reliability test plan, reliability considerations for animal implantation tests, in vitro and animal in vivo performance goals, the qualification of design changes during the Investigational Device Exemption clinical trial, the development of a Failure Modes Effects and Criticality Analysis, and the reliability information for surgeons and patient candidates. The document will be periodically reviewed to assess its timeliness and appropriateness within five years.

Animals↗

Design considerations for bearingless rotary pumps.

The designs of rotary blood pumps have shown substantial technical progress over recent years, especially contact bearing designs. However, the concern for potential thromboembolism remains and can only be eliminated by the use of bearingless pumps. Bearingless designs can be achieved through the application of magnetic, hydrodynamic, and hydrostatic forces or a proper combination of these forces. Although a purely magnetically suspended, actively controlled system can be designed, judicious use of hydraulic forces can allow simplification of device configuration and control. In this study, bearingless designs were evaluated for both axial and centrifugal pump configurations. Trade-offs between shear rates and bearing leak rates were considered based upon constraints imposed by hemolysis and residence time. These principles were used for determining the design feasibility of a rotary pump using combined magnetic and hydraulic stabilizing forces.

Biomechanical Phenomena↗

Temperature-controlled laser photocoagulation of soft tissue: in vivo evaluation using a tissue welding model.

BACKGROUND AND OBJECTIVES: Laser surgical procedures involving photocoagulation of soft tissue have relied on subjective visual endpoints. The thermal damage to the denatured tissue in these procedures is highly dependent on the tissue temperatures achieved during laser irradiation. Therefore, a system capable of real time temperature monitoring and closed loop feedback was used to provide temperature controlled photocoagulation (TCPC). STUDY DESIGN/MATERIALS AND METHODS: The TCPC system consisted of a 1.32 microns Nd:YAG laser, an infrared thermometer, and a microprocessor for data acquisition and feedback control. A porcine skin model was used. Tissue welds were completed to evaluate the photocoagulation effects at different predetermined temperatures. A quantitative measurement of tissue photocoagulation was obtained by tensile strength measurements of the laser repairs. Histology of the irradiated tissue was used to determine the extent of thermal injury associated with different photocoagulation temperatures. RESULTS: The TCPC system was capable of maintaining a relatively constant temperatures (+/- 4 degrees C) during laser irradiation. The tensile strengths of acute repairs increased with temperature over the range studied (65-95 degrees C). Tensile measurements made after several days of healing showed that higher temperature (95 degrees C) welds had lower strengths than repairs completed at lower (65 degrees C or 75 degrees C) temperatures and were significantly lower at 3 days. Acute histology showed that the amount thermal damage was strongly dependent on the tissue temperature and increased both in tissue depth and lateral to the repair with temperature. The histologic results suggest that the increase in the acute repair tensile strength as the weld temperature increased was due to an increase in the depth of tissue photocoagulation. The increase in the lateral tissue injury measured histologically for higher temperature welds likely resulted in the decreased chronic tensile strengths, as a healing response to excessive thermal damage. CONCLUSION: Tissue temperatures can be controlled during laser photocoagulation of skin. The degree of acute and chronic tissue damage is highly dependent on the temperature during welding. By controlling the tissue temperature during laser procedures, the surgical outcome can be more reliably predicted and reproduced, as compared to the conventional open loop methods. In addition, the use of a TCPC system should significantly reduce the learning curve for photothermal surgical procedures.

Animals↗

Laser assisted vascular welding with real time temperature control.

BACKGROUND AND OBJECTIVE: Previous studies in laser assisted vascular welding have been limited by the lack of a reliable end point for tissue fusion. As a means of improving the reproductibility of laser assisted repairs, a system incorporating real time temperature monitoring and closed loop feedback was used. STUDY DESIGN/MATERIALS AND METHODS: The system consisted of a direct view infrared thermometer for monitoring the laser heated spot, a 1.9 microns diode laser, and a microprocessor for data acquisition and feedback control of the laser power to maintain a constant tissue temperature. Rat aortas were welded under constant surface temperature conditions. RESULTS: In vivo temperature stability of +/- 2 degrees C was achieved over a temperature range of 70-90 degrees C pertinent to welding small vessels. When welds were completed using the feedback system to maintain the tissue temperature at 80 degrees C, the acute success rate was 100% and the burst pressure was 290 +/- 70 mmHg. CONCLUSION: These studies demonstrate that the use of real time monitoring and feedback control results in improved consistency for vascular tissue welding.

Anastomosis, Surgical↗

A magnetically suspended and hydrostatically stabilized centrifugal blood pump.

A magnetically suspended centrifugal blood pump intended for application as a long-term implantable ventricular assist device has been built and tested. The rotor is freely suspended in the blood by magnetic and hydrostatic restoring forces. This design obviates the need for bearings and shaft seals, and eliminates the problems of reliability and thrombogenicity associated with them. The positional stability and hydrodynamic performance of the pump has been characterized in vitro at flows of up to 10 L/min at physiologic pressures. Radial position control is realized by an analog electronic feedback control system. The pressure distribution in the fluid surrounding the rotor provides dynamic control in the axial direction with no active feedback. Rotor excursion is less than 50 microns (mu) when the housing receives an impulse peaking at an acceleration of 40 g or upon sudden blockage of the flow. In vitro blood measurements indicate an acceptable level of hemolysis compared with that of a standard centrifugal pump.

Animals↗

Absorption characteristics at 1.9 microns: effect on vascular welding.

A 1.9 microns laser was used to investigate the acute weld strengths for anastomoses of rat and rabbit aortas and femoral arteries. The wall thicknesses for these vessels approximately matched the optical absorption depth of 125 microns for 1.9 microns radiation in vascular tissues. A low power (150 mW) 1.9 microns laser was used. Laser power was delivered through silica fiber optics for manual control. The fiber tip was held approximately 1 mm from the target resulting in a laser spot size of 0.7 mm at the tissue. The linear delivery rate was approximately 0.3 mm/sec. Acute burst pressures of the welds showed a linear correlation with the reciprocal of the vessel radius. These results suggest that the product of the weld strength times the optical absorption depth is constant over the range of vessel sizes studied. A weld strength for a weld thickness equal to the optical absorption depth was determined to be 4 x 10(6) dynes/cm2, which is comparable to the strength of sutured anastomoses. These acute studies suggest that a laser wavelength with absorption depth in tissue matched to the vessel wall thickness should yield optimum welds. Therefore, a laser operating near 1.9 microns is suitable for small vessel welding.

Anastomosis, Surgical↗

Arterial laser welding with a 1.9 micrometer Raman-shifted laser.

A new 1.9 micron Raman-shifted neodymium:yttrium aluminum garnet (Nd:YAG) laser was used for small vessel welding. Bursting pressures and stresses of sutured and laser-welded arteriotomies created in the rat femoral artery and aorta were measured. Sutured arteriotomies had a significantly higher burst stress than laser-welded arteriotomies. Although there were no significant differences in burst stress at the various laser powers tested, an optimal power was identified. The laser was also used to weld transected rat aortas. The average power delivered was 200 mW for 30 seconds per anastomosis. The average time for completing an anastomosis was 6 minutes compared with 18 minutes when sutures were used. In relation to proximal aortic diameter, there was a 7.9% decrease at the anastomosis immediately (n = 4), and a 6.6% and 4.9% increase occurred at 24 hours (n = 4) and 10 weeks (n = 5), respectively. Acute anastomotic compliance, and compliance at 24 hours and 10 weeks were decreased by 47.2%, 39.5%, and 47.8%, respectively, and were similar to sutured anastomoses. Histology showed little thermal denaturation of the aorta within 0.6 mm of the anastomosis, approximately 1 mm of medial cell death, and nearly normal elastic fiber alignment. One focal false aneurysm was noted at 10 weeks. Although the sutured and laser-welded anastomoses share similar compliance changes, the laser-welded anastomoses are more isodiametric. This preliminary experience with the 1.9 micron laser shows the distinct advantages of a handheld fiber, no requirement for cooling irrigation, speed, and no difference in compliance from sutured anastomoses.

Analysis of Variance↗

Temperature as a periodontal diagnostic.

Elevated temperature, normally a characteristic of inflammation, is a potential indicator of periodontal disease. Conversely, local periodontal site temperatures within normal variation could suggest relative periodontal health. To evaluate this potential, a temperature probe was designed with rapid response (less than 1 s), high accuracy and reproducibility (+/- 0.1 degree C), good transducer thermal isolation and physical dimensions approximating those of a conventional periodontal probe. To compensate for subject-to-subject variations in core temperature, site temperatures were measured and expressed as differences relative to the sublingual temperature. A cross sectional study was conducted using this instrument in which pocket temperatures of 14 subjects with advanced adult periodontitis were measured and compared with the sulcus temperatures of 11 healthy subjects. Overall, the mean site temperature of the diseased subjects was 0.65 degree C higher than that of the healthy subjects. A natural posterior-to-anterior temperature gradient was observed with the posterior sites being hotter than the anterior sites. Tooth-by-tooth analysis showed that diseased teeth have higher temperatures than anatomically equivalent healthy teeth (p less than 0.01). Threshold temperatures for differentiating diseased and healthy teeth were determined to optimize sensitivity and specificity. The results suggest that site temperature is a diagnostic of inflammatory activity associated with periodontal disease. The specifically designed instrument detected significant disease-related departures from normality.

Body Temperature↗

A unique left-right flow imbalance compensation scheme for an implantable total artificial heart.

A new method has been developed for accommodating the difference between pulmonary and arterial flows in a totally implantable, hydraulically actuated total artificial heart (TAH). The left and right sides are alternately pumped, with concurrent filling of one pump and ejection from the other. A small hydraulic fluid chamber is used to compensate for the higher left sided flow. This chamber is incorporated into the left inflow of the TAH, with the flexing bladder in contact with atrial blood, and the hydraulic fluid communicates with the right sided hydraulic chamber. The volume of hydraulic fluid that enters and exits the latter chamber constitutes a corresponding reduction in the right sided blood chamber stroke volume. Placement of this compensation chamber in the left side inflow provides a negative feedback of the right sided flow, based on the left atrial pressure (LAP). Higher LAP (indicating too much right sided flow) leads to higher fluid flow to and from the compensation chamber and a lower right sided blood flow and vice versa. The hydraulic flow resistance can be preadjusted to yield a 15% flow difference at an LAP of 15 mmHg.

Animals↗

Chronic in vivo evaluation of an electrohydraulic total artificial heart.

Development of the Abiomed total artificial heart (TAH) designed for human use is progressing. Implant durations of longer than 60 days have been achieved in calves. The device consists of blood pumps, valves, and a hydraulic atrial flow balancing chamber fabricated from polyetherurethane. The energy converter, a centrifugal hydraulic pump with a rotary fluid switching valve, is positioned between the blood pumps. In two consecutive chronic in vivo studies (47 days and longer than 60 days), cardiac output was maintained in excess of 8 l/min. The atrial flow balancing chamber maintained a mean right-to-left pressure gradient of 7.5 and -1.4 mmHg in each respective study. There were no pulmonary complications. Platelet counts, fibrinogen concentrations, and hematocrit values returned to baseline levels within 20 days, whereas bilirubin, serum glutamic-oxaloacetic transaminase, blood urea nitrogen, and creatinine levels returned to normal within 1 week of implant. After the first post-operative day, plasma free hemoglobin levels of less than 10 mg/dl indicated no device-related hemolysis throughout the duration of the studies. At explant (47 day study), pathologic analysis showed no renal infarcts, no tissue necrosis, and no thermal damage. The device was fully encapsulated by 2-4 mm thick fibrous connective tissue. A newly designed textured-to-smooth surface inflow showed no signs of pannus ingrowth or thrombotic complications. These studies demonstrate that this TAH is suitable for long-term implantation.

Animals↗

Progress in the development of the ABIOMED total artificial heart.

The ABIOMED implantable total artificial hearts in the final phase of engineering development. The system has a compact electrohydraulically driven energy converter sandwiched between two blood pumps, an internal electronics pack, an internal battery, a transcutaneous energy transmission coil for power transmission, and external wearable electronics pack and battery. The current effort is to complete development of the system during 1996 in preparation for formal pre clinical testing of the device. In vivo studies with the current thoracic unit (ABH II) have achieved 108 days of survival verifying the thermal, physiologic, and hematologic compatibility of the system. The abdominal implantable electronics pack showed no thermal dissipation problem. System improvements include scaling down the size of the thoracic unit, and efficiency enhancement in the power and hybrid electronics. The new system (ABH III) retains the flow capacity of greater than 10 L/min. Size reduction results in an atrial to sternal dimension that would fit 98% and 75% of men and women, respectively.

Animals↗

Long-term mechanical circulatory support system reliability recommendation: American Society for Artificial Internal Organs and Society of Thoracic Surgeons: long-term mechanical circulatory support system reliability recommendation.

Jointly developed by members of the American Society for Artificial Internal Organs and the Society of Thoracic Surgeons along with staff from the Food and Drug Administration, the National Heart, Lung and Blood Institute and other experts, this recommendation describes the reliability considerations and goals for Investigational Device Exemption and Premarket Approval submissions for long-term, mechanical circulatory support systems. The recommendation includes a definition of system failure, a discussion of an appropriate reliability model, a suggested in vitro reliability test plan, reliability considerations for animal implantation tests, in vitro and animal in vivo performance goals, the qualification of design changes during the Investigational Device Exemption clinical trial, the development of a Failure Modes Effects and Criticality Analysis, and the reliability information for surgeons and patient candidates. The document will be periodically reviewed to assess its timeliness and appropriateness within five years.

Clinical Trials as Topic↗