Perioperative myocardial ischemia: pathophysiology and does it really matter.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R Teplick.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The preoperative cardiac assessment of the thoracic patient differs very little from the assessment of any patient for noncardiac surgery, aside from a few special issues. Therefore, rather than reviewing the general issue of evaluation for noncardiac surgery, which is a topic that has been reviewed many times in the recent past, this article focuses on the purposes, methods, and limitations of risk assessment in the noncardiac surgical patient with suspected coronary artery disease (CAD), including thoracic surgical patients. Because risk assessment is imprecise and the main indications for invasive coronary procedures prior to noncardiac surgery are the same for any person for whom life-expectancy is expected to be prolonged, meticulous preoperative evaluation for CAD is not usually warranted, even for patients undergoing high-risk surgery or with multiple risk factors for CAD. To help understand this point of view and to utilize cardiology consultants appropriately, implications of basic pathophysiology as well as statistical principles are also discussed.
The inadequacy of the current techniques to monitor renal function has been the most important limitation for determining the appropriateness of a particular form of therapy in acute renal failure. The objective of this study was to determine the advantage offered by a new method of accurate, noninvasive, and real-time monitoring of renal function during the critical care of patients. A radiation detector attached to a miniature data logger was used to monitor the clearance of the glomerular filtration agent 99mTc-diethylene triamine pentaacetic acid from the extracellular space in 20 patients admitted into an intensive care unit. The rate constant for this clearance was calculated online from 5-min epoch lengths of activity versus time. Changes in this constant were compared with changes in plasma creatinine and timed urine output. The results showed that the ambulatory renal monitor could accurately measure rapid changes in renal function during the critical care of patients who are at risk of acute renal failure with a resolution time of 5 to 10 min. The sensitivity and specificity of the technique are also superior to plasma creatinine and urine output because it can detect minimal and transient changes in renal function that otherwise may have gone undetected by these parameters. This unique approach should allow for the immediate institution and/or adjustment of the appropriate therapeutic procedure to preserve or improve the renal function.
OBJECTIVE: Mechanical ventilation is thought to increase the risk of nosocomial pneumonia by permitting leakage of bacteria-laden gastro-oropharyngeal secretions into the upper airways. The goal of this study was (a) to validate radiographic signs of pooled secretions above endotracheal-tube cuffs (supracuff liquid) in an animal model and (b) to determine whether suctionable pooled supracuff liquid can be identified on bedside radiographs of intubated patients. MATERIALS AND METHODS: Diagnostic criteria for supracuff liquid were initially validated by three radiologists interpreting 162 randomized radiographs made in an intubated sheep cadaver. The primary criteria included (a) replacement of the normal supracuff lucency with liquid opacity and (b) the formation of a sharp interface between the lucency of the upper edge of the cuff below and the liquid above. Graded infusions of 0, 3, 8, 13, and 23 ml of saline were made in triplicate into the space above the cuff, and radiographs were evaluated for the presence or absence of saline. The validated diagnostic criteria were used by two radiologists to estimate the frequency with which pooled liquid was seen on portable chest radiographs of 47 patients undergoing elective short-term postanesthetic mechanical ventilation. RESULTS: In the sheep-cadaver model, the diagnostic criteria for supracuff liquid allowed successful differentiation between no liquid, a small amount of liquid (3-8 ml), and a large amount of liquid (13-23 ml; c2, p < .0001). In a clinical study, radiographic signs of supracuff liquid were identified in 57% of 47 patients. In a small subset of patients (n = 18), the estimated liquid volume (mean +/- SEM) was calculated to be 7.8 +/- 1.1 ml (range = 2.1-18.4 ml). CONCLUSIONS: Radiography is a sensitive means of identifying small volumes of supracuff liquid above the inflated cuffs of endotracheal tubes. Potentially contaminating liquid pooled above the cuff of an endotracheal tube can be identified in about half of patients undergoing short-term mechanical ventilation. Our results suggest the suction of the supracuff space may be a reasonable prophylactic maneuver against nosocomial pneumonia. A much larger study is suggested to investigate the actual relation between pooled supracuff liquid and the development of nosocomial pneumonia.
To test for oxygen wasting by norepinephrine (NE) without relying on normalization by measures of performance such as the pressure-volume area, myocardial oxygen consumption (MVO2) was determined for isovolumic beats at five different left ventricular (LV) end-diastolic volumes (EDV) in nine isolated cross-perfused canine hearts in each of three states: a basal anesthetic state (B); after depression with halothane (H); and after adding NE to increase contractility back to the B state (H+NE). The end-diastolic and peak systolic pressure-volume lines were identical for B and H+NE. The R2 for a linear regression of MVO2 per beat for B vs. H+NE for beats originating at the same EDV and developing similar (within 10%) peak isovolumic pressures for all hearts was 0.85. The slope and intercept were 0.83 and 0.01, which are significantly less than one (P less than 0.001) and greater than zero (P less than 0.001), respectively. These data suggest that NE increases both the economy of pressure development as well as activation energy of an isovolumically contracting LV.
A prospective, randomized study was conducted to compare the retroperitoneal versus transperitoneal approach for elective aortic reconstruction. One hundred thirteen patients (transperitoneal = 59, retroperitoneal = 54) were randomized between March 1987 and October 1988. In addition, to assess the changing course of patients undergoing aortic reconstruction similar data were gathered retrospectively on a group of 56 patients undergoing aortic reconstruction by the same surgeons performed via a transperitoneal approach in 1984 to 1985. Randomized patients were identical in age, male to female ratio, smoking history, incidence and severity of cardiopulmonary disease, indication for operation, and use of epidural anesthetics. Details of operation including operative and aortic cross-clamp times, crystalloid and transfusion requirements, degree of hypothermia on arrival at the intensive care unit, and perioperative fluid and blood requirements did not differ significantly for patients undergoing transperitoneal versus retroperitoneal reconstruction. Respiratory morbidity, as assessed by percent of patients requiring postoperative ventilation, deterioration in pulmonary function tests, and the incidence of respiratory complications, was identical in randomized patients. Other aspects of postoperative recovery including recovery of gastrointestinal function, the requirement for narcotics, metabolic parameters of operative stress, the incidence of major and minor complications, and the duration of hospital stay were similar for randomized patients undergoing transperitoneal and retroperitoneal reconstruction. When compared to retrospectively reviewed patients having aortic reconstruction, randomized patients undergoing transperitoneal and retroperitoneal operations had highly significant (p less than 0.001) reductions in postoperative ventilation, transfusion requirements, and length of hospital stay. Such trends were all independent of transperitoneal versus retroperitoneal approach.(ABSTRACT TRUNCATED AT 250 WORDS)
Labetalol, a combined alpha 1- and nonselective beta-adrenergic blocking drug, was compared to lidocaine or saline to minimize the hypertensive and tachycardic response to intubation in a controlled randomized double-blind study in patients undergoing surgical procedures under general anesthesia. Forty adult patients were divided into four groups of 10 each: placebo (saline), lidocaine 100 mg, labetalol 5 mg, or labetalol 10 mg. The double-blind preparation was administered as an IV bolus just prior to induction and 2 min before the stimulus of laryngoscopy and intubation. Heart rate and blood pressure were measured at 1-min intervals for 2 min prior to induction of anesthesia and through 6 min following induction of anesthesia. Labetalol 10 mg prevented a rise in heart rate after intubation compared to patients who received placebo, lidocaine 100 mg, or labetalol 5 mg. The hypertensive response to intubation was similar in all four groups. Labetalol 10 mg IV just prior to induction of anesthesia is a safe and cost-effective means of preventing tachycardia but not hypertension in response to laryngoscopy and intubation.
Massive elevation of intra-abdominal pressure (IAP) causes cardiovascular, respiratory, and renal dysfunction. We managed eight patients with high IAP (mean 51 +/- 7 cm H2O), six of whom had hemodynamic measurements; a clinical syndrome, characterized by hemodynamic, respiratory, and renal dysfunction, then became apparent. We report a) a baseline cardiopulmonary profile and response to an acute vascular volume challenge in six patients and b) surgical decompression of the abdomen in four patients. The clinical impression of hypovolemia was confused by small to normal left ventricular end-diastolic volume (64 +/- 14 ml) and normal ejection fraction (55 +/- 6%) despite very high right and left atrial filling pressures. Complete ventilatory support was necessary to maintain oxygenation and ventilation; oliguria (urine output less than 10 ml/h) was present. Pericardial effusion was absent. After fluid challenge (10 ml/kg of colloid or crystalloid infused iv over 10 min), filling pressures, cardiac output, and stroke volume all increased significantly (p less than .025) while heart rate decreased. Surgical decompression of the abdomen improved oxygenation, ventilation, cardiac output, atrial filling pressures, and urine output within 15 min. The cardiovascular effects of massively elevated IAP compounded by the requisite supportive care may require surgical relief.
Zero stability tests were performed on contrasting, commercially available, blood pressure-transducer systems. One system was based on a brand of disposable transducer. The others employed one brand of reusable transducer with and without samples of two different brands of compatible disposable domes. Drift was measured at atmospheric pressure over 3-hr periods. Drifts with the disposable transducers and with the bare reusable transducers were small, ranging from -2 to +2 mm Hg over 3 hr. However, the drifts of the reusable transducers with domes were significantly greater, ranging from -11 mm to +5 mm Hg. The disposable transducers did not drift significantly after the first half hour, although the reusable transducers with domes continued to drift. In addition, one brand of disposable dome produced inaccurate calibrations with the reusable transducer. The methodology of drift measurement and analysis should be practical and useful in other settings and with other brands of transducers. In general, the results indicate that periodic zeroing is still a clinically important procedure, and it is a worthwhile effort prior to treatment decisions based on pressure readings.
To determine whether the oxygen cost of force development in the canine left ventricle is constant throughout systole, we inserted fluid-filled Latex balloons into eight isolated canine left ventricles perfused via support dogs. Balloon volumes were varied by a hydraulic servoactuator designed to withdraw preset volumes rapidly (0.5 ml/msec) beginning at a specified ejection pressure. Oxygen consumption was related to force-time integrals for 9-12 different ejections patterns formed by ejecting three or four different volumes from the same end-diastolic volume, each ejection beginning at three different pressures, isovolumic beats with four or five different end-diastolic volumes, including those used for the ejections. The force-time integral vs. oxygen consumption data are nonlinear for ejections that began at low pressures, with oxygen consumption exceeding that predicted from regression lines fitted to the isovolumic data. This difference appeared to peak at relatively low force-time integrals and then curve back to converge with the isovolumic line. This pattern was not evident for ejections that began late in systole. Although these results suggest that the energy required for force development is greater than expected early in systole, they also are consistent with the hypothesis that oxygen consumption is a function only of instantaneous ventricular volume.
To determine if patients who have undergone uneventful vascular surgery (VS), nonvascular intracranial surgery (ICS), or anterior cervical laminectomies (ACL) have enough serious postoperative problems to justify routine overnight observation in an intensive care unit (ICU), we recorded every problem and associated therapy administered to 263 such patients within 36 h of ICU admission. The severity of each treated problem was graded from 1 (safe to delay treatment for at least 2 h) to 4 (life-threatening, immediate treatment required). Defining patient benefit from the ICU as treatment for one grade 4 problem or more than one grade 3 problem, 44% of VS patients (N = 177), 14% of ICS patients (N = 73), and none of the ACL patients (N = 13) benefited. We conclude that these percentages justify an overnight ICU stay for all VS patients, especially as the occurrence of serious problems was unpredictable and most serious problems were still being treated 4 h postoperatively. Furthermore, routine ICU admission of all patients in the groups studied would reduce patient costs if only 13 of the 88 patients who benefited were prevented from becoming critically ill.
Explore the source record for details and available documents.
Estimates of ventilation-perfusion ratio (VA/Q) distributions from foreign gas infusions have utilized a discrete lung model that constrains all alveoli to have 1 of 50 specified VA/Q. In contrast, distribution estimates based on a continuous model allow alveoli to have any VA/Q and can be derived directly from foreign gas data or by transforming distributions derived using the discrete model. We have compared analytically and empirically the properties of distributions based on these two models. Unlike the discrete model, the shape of distributions obtained from the continuous model are insensitive to changes in the VA/Q used in their calculation. Perfusion distributions found from the discrete model using VA/Q values evenly spaced on a logarithmic scale resemble ventilation distributions derived from the continuous model. In contrast, by use of VA/Q evenly spaced on a linear scale, perfusion distributions derived from either model have a similar shape. We concluded that physiological inferences derived from distribution shapes may vary according to the model employed. However, those based upon cumulative perfusion or distribution moments are invariant.
Explore the source record for details and available documents.
A clinical study was conducted to determine if the systolic spike often observed in an invasive blood pressure display originates in the measurement system. The clinical system consisted of a catheter, stopcocks, 4 ft of tubing, an amplifier (containing a 12-Hz low-pass filter), and a continuous flush device. A second transducer was connected directly to the patient's catheter, in parallel with the clinical system. Its output was conditioned by an amplifier modified to exclude the low-pass filter. Simultaneous measurements were taken from both transducers, recorded, and later analyzed. A comparison of the traces in the time domain, as well as an analysis of the signals in the frequency domain, suggests that the systolic spike did not originate in the pressure tubing or in the amplifier system.