PubMed Health⌕ Search

Biomedical subjects

R Thorsen

Publications and source records attributed to R Thorsen.

8 recordsLinked to original sources

A pilot study of myoelectrically controlled FES of upper extremity.

Functional electrical stimulation (FES) of upper limbs can be used for the recovery of some hand functions on patients with CNS lesions. This study deals with the control of FES by means of myoelectrical activity detected from voluntarily activated paretic muscles. The specific aim of this paper is to evaluate the accuracy of myoelectrical control in terms of produced force and movement. For this purpose, a specific device called myoelectrical controlled functional electrical stimulator (MeCFES) has been developed and applied to six tetraplegic patients with a spinal cord lesion and one stroke hemiplegic patient. Residual myoelectric signals from the paretic wrist extensor (m. extensor carpi radialis, ECR) have been used to control stimulation of either the wrist extension (i.e., the same muscle) or thumb flexion. A tracking test based on a visual feedback of the produced force or movement compared to a reference target trajectory was used to quantify control accuracy. A comparison was made between the tracking performances of each subject with and without the MeCFES and the learning process for two of the subjects were observed during consecutive sessions. Results showed that the wrist extension was improved in three out of five C5 SCI patients and the thumb flexion was largely increased in one incomplete C3 SCI patient. The hemiplegic patient showed limited thumb control with the MeCFES but indicated the possibility of a carry over effect. It was found that a low residual natural force resulted in a less accurate movement but also with a large increase (up to ten times) of the muscle output. On the contrary, persons with a medium residual force obtained a smaller amplification of muscle force with a higher tracking accuracy.

Adult↗

EMG signals detection and processing for on-line control of functional electrical stimulation.

The surface EMG signal detected from voluntarily activated muscles can be used as a control signal for functional neuromuscular electrical stimulation. A proper positioning of the recording electrodes in relation to the stimulation electrodes, and a proper processing of the recorded signals is required to reduce the stimulus artefact and the non-voluntary contribution (M-wave). Six orientations and six locations of the recording electrodes were investigated in the present work. A comb filter (with and without a blanking windowing) was applied to remove the signal components synchronously correlated to the stimulus. An operative definition of the signal to noise ratio and an efficiency index were implemented. It resulted that when the recording electrodes were located within the two stimulation electrodes the best orientation was perpendicular to the longitudinal line. However the best absolute indexes were obtained when the recording electrodes were located externally of the stimulation electrodes, and in that case the best orientation was longitudinal. Concerning the filtering procedure, the use of a blanking window before the application of the comb filter, gave the best performance.

Artifacts↗

Functional control of the hand in tetraplegics based on residual synergistic EMG activity.

A microprocessor controlled device (MeCFES) was used for the investigation of the possibility of restoring hand function in C5 tetraplegics with paralysis of the hand. To date, 3 tetraplegics have been testing the system. The myoelectric signals from wrist extension were recorded and used as control signals for functional electrical stimulation (FES) of thumb adduction/flexion. The results have shown that the device can improve the hand function of tetraplegics. In this part of the work, a hand function test was designed and used to assess the results.

Electric Stimulation Therapy↗

An artefact suppressing fast-recovery myoelectric amplifier.

An amplifier for recording myoelectric signals using surface electrodes has been developed. The special features are suppression of stimulation artefacts and motion artefacts from electrodes. It is designed for recording of myoelectric signals from a muscle that is being stimulated with short impulses. The artifact suppression is achieved by using fast-recovery instrumentation amplifiers and having a nonlinear feedback loop for automatic compensation of changes in DC-offset.

Artifacts↗

Long-term anticoagulant therapy after myocardial infarction in women.

A multicentre trial from five medical departments in Oslo has been carried out to determine the value in women patients of one year's long-term anticoagulant therapy. Follow-up long-term laboratory control and anticoagulant dosage were performed at one centre (the Rikshospitalet). One hundred and fifty-nine patients were assigned randomly into two similar well-matched groups (control and treatment). Dosage was controlled by Thrombotest, aiming at 10-20% levels, and 50% of the tests were less than 14%. Compared with the control group, the treatment group showed a significant reduction in mortality and in reinfarction rate. No serious bleeding complications occurred. It is concluded that women benefit as much as men from long-term anticoagulant therapy.

Aged↗