Foreign body retrieval with the braiding maneuver.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R Uflacker.
Explore the source record for details and available documents.
PURPOSE: To report the preliminary results in a trial comparing the Amplatz mechanical thrombectomy (MT) device with surgical thrombectomy (ST) to declot occluded dialysis access grafts. PATIENTS AND METHODS: Thirty-seven patients were randomly assigned by computer to either ST (n = 18) or MT (n = 19). Diagnostic fistulograms were obtained at the end of the procedure, and Doppler ultrasound was performed at 1-month follow-up. Plasma free hemoglobin levels were measured before, immediately after, and 24 hours after the procedure in the MT group. Success was defined as initial success with restoration of flow through the graft, primary patency at 30 days, and secondary patency at 30 days. RESULTS: Technical success with MT was 89%. Primary patency in the MT series was 47% and secondary 30-day patency was 68%. Technical success with ST was 83%. Primary patency in the ST series was 77% and secondary patency at 30 days was 77%. Angioplasty (n = 18) and stent placement (n = 6) were performed in the MT cases. Angioplasty was impossible in one patient. Immediately after MT, plasma free hemoglobin levels above normal were noted in 63% of the cases, but these levels were within normal levels after 24 hours in 88% of the cases. CONCLUSION: Initial success of MT in patients with occluded dialysis access grafts is comparable to that of ST. No statistically significant differences in primary or secondary patencies were seen.
PURPOSE: To determine the feasibility of using the Amplatz thrombectomy device (ATD) to treat massive pulmonary embolism (PE). PATIENTS AND METHODS: Five patients (four men, one woman; mean age, 45.2 years) with massive PE underwent mechanical thrombectomy with the ATD, which creates a vortex that pulverizes and recirculates the clots within the pulmonary circulation. The patients were followed up for 7-18 months after thrombectomy. RESULTS: Marked improvement in pulmonary perfusion was observed in three patients at angiography and ventilation-perfusion scanning. No changes could be assessed in one patient who died shortly after the procedure. One patient developed hemoptysis during the procedure, most likely because of a reperfusion syndrome. A reduction in pulmonary artery pressure was observed in only one patient; the remaining patients had increased pressure. The four surviving patients were discharged within 8 days. CONCLUSION: Mechanical thrombectomy with the ATD provides rapid debulking of thrombus in some patients with massive PE and has the potential to improve treatment and outcomes of the most sick patients.
Explore the source record for details and available documents.
PURPOSE: To perform a feasibility study of the Amplatz Thrombectomy Device (ATD) in a variety of vascular territories with acute or subacute thrombosis. MATERIALS AND METHODS: Thirteen patients (mean age, 44.6 years) with multiple risk factors who had acute/subacute thrombosis of the inferior vena cava (IVC) and iliac veins (n = 3), superior vena cava (SVC) and/or subclavian veins (n = 3), lower extremity polytetrafluoroethylene (PTFE) graft (n = 2), iliac artery (n = 2), portal vein and transjugular intrahepatic portosystemic shunt (TIPS) (n = 2), and an IVC to pulmonary artery Fontan conduit (n = 1), were treated by means of mechanical thrombectomy with use of the ATD. Thrombolysis failed to recanalize the vessels when used before thrombectomy for 12-34 hours in three patients, and was contraindicated in three other patients. Thrombolysis was used as a complement to the ATD procedure in five patients. RESULTS: Technical success was achieved in 11 patients, and procedure success was achieved in 10 patients. Failure was observed in the remaining three patients. One patient with a PTFE graft was successfully declotted but thrombosis occurred 2 weeks later, requiring surgery. The other patient with a PTFE graft did not improve and needed surgery to declot and treat the distal anastomosis and distal circulation. The two patients with an occluded iliac artery underwent successful declotting but rethrombosis occurred in one shortly after the procedure requiring thrombolytic therapy. One patient with TIPS thrombosis improved and another patient with a thrombosed portal vein did not improve after thrombectomy. CONCLUSION: The ATD is useful for recanalization of acute/subacute clotted native vessels and grafts. The application of the device is broad, and although declotting can be achieved in most cases, long-term success may be limited by anatomical and technical problems of the grafts and multifactorial clinical problems of severely sick patients, as was the case in the series. The use of additional thrombolytic therapy may be necessary in a number of patients.
PURPOSE: To evaluate the treatment of abdominal aortic aneurysm (AAA) with use of the endoluminal Talent stent-graft (TSG). PATIENTS AND METHODS: In 10 men, AAA treatment was attempted with use of the TSG. All patients presented significant surgical risk, with chronic obstructive pulmonary disease and coronary arteriopathy. The mean age was 65.5 years (range, 57-82 years). The mean proximal neck diameter was 25.8 mm (range, 21.6-34 mm). Five of the TSGs were straight tubes and five were bifurcated systems. The main body of the TSG is made of a polyester graft material mounted on a self-expandable nitinol frame. The bifurcated system uses polytetrafluoroethylene (PTFE) material for the legs and extensions mounted on a self-expandable nitinol frame. The bifurcated grafts used a 22 to 27-F introducer and the extensions, a 18-F introducer through a surgical cutdown technique. RESULTS: The TSG system was successfully implanted in nine patients and failed in one because of dislodgment after deployment, which required conversion to surgery. Four leaks occurred initially. One was sealed off with balloon dilation at the end of the procedure, one leak was treated with an additional extension, another leak disappeared spontaneously in 30 days, and the other leak required embolization 4 weeks after discharge. Seven patients were discharged on the third day after the procedure, and two patients were discharged at 1 and 2 weeks, respectively. Blood transfusion was necessary in three patients because of hematoma at the incision site in two patients, which required surgical revision for hemostasis, and because of transoperative bleeding in one patient. Follow-up time ranged from 2 to 15 months. The only death occurred 5 days postoperatively as a consequence of ischemic colitis and multisystem organ failure in the only patient who required surgery. CONCLUSION: Treatment of AAA with the TSG system is effective for aneurysm exclusion. This device seems to provide a good alternative to surgery in patients who are otherwise considered to be at high risk for complications after direct surgical repair, but it is not without risk of complications.
Absolute ethanol was used to ablate tumors, inflammatory lesions, and end-stage nephrosclerotic kidneys in 38 patients. Thirty patients had various types of renal tumors, and 3 had chronic end-stage renal failure with malignant hypertension. One patient had a fibrosarcoma of the right leg and one had a metastasis in the humerus from a renal carcinoma. A large adrenal carcinoma was treated with absolute ethanol in a patient who had liver metastases that were ablated one year after the first procedure. An additional patient had metastatic liver disease from a non-functioning adrenal carcinoma. The remaining patient had an extensive hypervascular inflammatory lesion (tuberculosis and aspergilloma) of the right upper pulmonary lobe. In addition to ethanol, coils were introduced in one patient and Gelfoam in another. The amount of ethanol used ranged from 5 to 50 ml. Twenty-two patients suffered from considerable transient pain during ethanol injection, but sedation was necessary in only 3 of them. Skin necrosis appeared in 2 patients requiring plastic reconstruction in one of them. Two patients died within 5 days of the procedure unrelated to the ablation. Two patients presented upper gastrointestinal bleeding within 2 days of the ethanol injection and one of these died in acute renal failure. One patient suffered from left colonic infarction after left renal tumor ablation, but survived for several months. Absolute ethanol was a useful and efficient sclerosing agent causing extensive tumor destruction and marked reduction of the vascularity in tumor and inflammatory lesions, but caused an 18 per cent complication rate.
In the authors' experience, 0.24% of the patients submitted to liver imaging (ultrasound or computerized tomography) have hemangiomas. These are shown as solid nodular lesions, mostly found by chance. Sometimes they do not appear as typical solid vascular lesions. The authors' experience and the literature are discussed. A clear and concise approach to this benign neoplasm is suggested.
Treatment of lower gastrointestinal bleeding was attempted in 13 patients by selective embolization of branches of the mesenteric arteries with Gelfoam. Bleeding was adequately controlled in 11 patients with active bleeding during the examination. One patient improved after embolization but bleeding recurred within 24 hours and in another patient the catheterization was unsuccessful. Five patients with diverticular hemorrhage were embolized in the right colic artery four times, and once in the middle colic artery. Three patients had embolization of the ileocolic artery because of hemorrhage from cecal angiodysplasia, post appendectomy, and leukemia infiltration. Three patients had the superior hemorrhoidal artery embolized because of bleeding from unspecific proctitis, infiltration of the rectum from a carcinoma of the bladder, and transendoscopic polypectomy. One patient was septic and bled from jejunal ulcers. Ischemic changes with infarction of the large bowel developed in two patients and were treated by partial semi-elective colectomy, three and four days after embolization. Four other patients developed pain and fever after embolization. Transcatheter embolization of branches of mesenteric arteries is an effective way to control acute lower gastrointestinal bleeding, but still has a significant rate of complications that must be seriously weighed against the advantages of operation.