PubMed Health⌕ Search

Biomedical subjects

R Vosshenrich

Publications and source records attributed to R Vosshenrich.

At least 19 recordsLinked to original sources

[Contrast agents in MRT. Substance, effects, pharmacology and validity].

The use of intravenous contrast agents in magnetic resonance imaging (MRI) has become well established clinical practice. Contrast agents provide additional information in many applications. Gadolinium chelates constitute the largest group of MR contrast agents and are considered to be safe. Different groups of contrast agents are established for clinical application: low concentrated gadolinium chelates, high concentrated gadolinium chelates, superparamagnetic iron oxide particles and hepatobiliary contrast agents. The review discusses the clinical applications and the safety issues involved with administration of intravenous contrast agents in MR imaging. Several approaches of intravascular or blood pool agents are also presented.

Anaphylaxis↗

Diagnosis and follow up of aortitis in the elderly.

OBJECTIVES: To evaluate the correlation of MRI and [(18)F]FDG-PET scans with the clinical course and inflammatory markers in patients with aortitis. METHODS: Eight patients with aortitis presenting with unspecific GCA-like symptoms were examined. Aortitis was diagnosed and followed up by [(18)F]FDG-PET and MRI. The aorta was divided into three vascular regions (ascending aorta, aortic arch, and descending aorta) to localise the aortic inflammation and compare both imaging techniques. RESULTS: were correlated with clinical and laboratory examinations. RESULTS: At diagnosis, 20/24 vascular regions from eight patients were positive by [(18)F]FDG-PET scan and 15/21 aortic regions by MRI. Patients were treated with corticosteroids and followed up for a mean (SD) of 13.3 (4.7) months. In [(18)F]FDG-PET, 11/20 (55%) initially pathological aortic regions returned to normal in the follow up examination, which correlated closely with the clinical and laboratory follow up examination. Conversely, in MRI, 14/15 initially affected vascular regions were unchanged. CONCLUSIONS: [(18)F]FDG-PET and MRI are both effective techniques for detecting early aortitis and have a high correlation with laboratory inflammatory measures. However, during the follow up examination, [(18)F]FDG-PET uptake decreased in line with the clinical symptoms and inflammatory serum markers, whereas MRI scans gave more static results.

Aged↗

Early diagnosis and follow-up of aortitis with [(18)F]FDG PET and MRI.

The aim of this prospective study was to compare fluorine-18 fluorodeoxyglucose ([(18)F]FDG) positron emission tomography (PET) with magnetic resonance imaging (MRI) in patients with early aortitis, at the time of initial diagnosis and during immunosuppressive therapy. The study population consisted of 15 patients (nine females and six males; median age 62 years, range 26-76 years) who presented with fever of unknown origin or an elevated erythrocyte sedimentation rate or elevated C-reactive protein and who showed pathological aortic [(18)F]FDG uptake. Fourteen of these patients had features of early giant cell arteritis (GCA), while one had features of early Takayasu arteritis. During follow-up, seven PET scans were performed in six patients with GCA 4-30 months (median 19 months) after starting immunosuppressive medication. The results of [(18)F]FDG imaging were compared with the results of MRI at initial evaluation and during follow-up and with the clinical findings. At baseline, abnormal [(18)F]FDG uptake was present in 59/104 (56%) of the vascular regions studied in 15 patients. Seven follow-up PET studies were performed in six patients. Of 30 regions with initial pathological uptake in these patients, 24 (80%) showed normalisation of uptake during follow-up. Normalisation of [(18)F]FDG uptake correlated with clinical improvement and with normalisation of the laboratory findings. All except one of the patients with positive aortic [(18)F]FDG uptake were investigated with MRI and MRA. Thirteen of these 14 patients showed inflammation in at least one vascular region. Of 76 vascular regions studied, 41 (53%) showed vasculitis on MRI. Of 76 vascular regions studied with both PET and MRI, 47 were concordantly positive or negative on both modalities, 11 were positive on MRI only and 18 were positive on PET only. MRI was performed during follow-up in six patients: of 17 regions with inflammatory changes, 15 regions remained unchanged and two showed improvement. Whole-body [(18)F]FDG PET is valuable in the primary diagnosis of early aortitis. The results of [(18)F]FDG PET and MRI in the diagnosis of aortitis in this study were comparable, but FDG imaging identified more vascular regions involved in the inflammatory process than did MRI. In a limited number of patients [(18)F]FDG PET was more reliable than MRI in monitoring disease activity during immunosuppressive therapy.

Adult↗

[Refixation of osteochondral fragments using absorbable implants. First results of a retrospective study].

An osteochondral lesion in a weight bearing joint causes therapeutic problems. Surgical therapy focuses on the restoration of the articular surface, unlimited motion of the joint and prevention of cartilaginous degeneration. A causal therapy to prevent posttraumatic osteoarthritis is the fixation of osteochondral fragments. Various absorbable implants for the purpose of refixation are available, but only a few have proved to be biocompatible. This retrospective study presents the preliminary results after refixation of osteochondral fragments of the ankle and knee joints. We used self-reinforced absorbable pins, nails and screws made of polylactide acid. The results for 15 patients with 17 fractures of 16 joints were evaluated. All patients were scored by the Tegner-activity-level, the McDermott-score and the DGKKT-score, and 13 of them were monitored by postoperative magnetic resonance imaging (MRI). The follow-up extended for an average of 14.3 months (range: 4-43 months). The clinical results for all patients were good (McDermott-score: Ø 89 points, DGKKT-score: Ø 78.8 points, Tegner: pre-op vs post-op=Ø 4.6 vs Ø 5.1) and the surgical therapy proved to be successful. The MRI showed the complete incorporation and vitality of the fragment as well as a congruence of the joint surface. The clinical course and the MRI gave little reference to an inflammatory reaction due to the implants that complicated the course of two patients. These results indicate that absorbable implants made of polylactide acid are biocompatible and effective in the fixation of osteochondral fragments.

Absorbable Implants↗

[Contrast-enhanced MR angiography of the arterial and portovenous system of the liver with varying concentrations of contrast medium].

PURPOSE: To evaluate the diagnostic value of a higher concentrated contrast medium (gadobutrol) for contrast-enhanced MRA of the hepatic arteries and portovenous system. MATERIALS AND METHODS: The examinations were performed on a 1.5-Tesla whole body imaging system (Magnetom Symphony Quantum, Siemens) with a 30-mTesla/m gradient field strength using a phased-array body coil. A 3D FLASH sequence (TR/TE/FA 3.88 ms/1.44 ms/25(3)) was used imaging the hepatic arteries and portovenous system after determination of the circulation time. The study included 50 patients, with 25 patients (group 1) injected with 0.2 mmol Gd-GTPA/kg body weight and 25 patients (group 2) injected with 0.1 mmol gadobutrol/kg body weight. The signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) were calculated for both groups. The image quality was graded by three radiologists on a 5-point scale. RESULTS: The highest SNR was measured in group 1, with no statistically significant differences of the SNR in the abdominal aortal, coeliac trunk and common hepatic artery. CNR was also similar in both groups. Likewise, portal, superior mesenteric and splenic veins showed no statistically significant differences. All cases were found to have a good image quality. CONCLUSION: For MRA of the hepatic arteries and the portal veins, the higher concentrated Gd-DTPA contrast medium gadobutrol can be used at half the dosage recommended for the standard Gd-DTPA contrast medium.

Adult↗

Value of F-18 FDG hybrid camera PET and MRI in early takayasu aortitis.

Takayasu aortitis (TA) is a chronic inflammatory and fibrotic vasculitis of large- and medium-sized arteries. Early stages of the disease show a panarteritis and inflammatory wall thickening of the aorta and its branches, whereas advanced (fibrotic) stages comprise stenosis, aneurismatic transformation and occlusion. Magnetic resonance imaging visualises early-stage disease with high accuracy and is considered to be the method of choice in the diagnosis of TA. The aim of this article is the detailed comparison of FDG-PET performed with a hybrid camera and MR imaging in five patients with early TA. Five patients (median age 60 years) were enrolled during an ongoing prospective study on [18F]2'-deoxy-2-fluoro-D-glucose (FDG) hybrid camera PET in patients with fever of unknown origin (FUO). These patients underwent MR imaging after establishing the diagnosis of TA. Abnormal FDG uptake in the wall of the aorta was noted in all patients. The bracheocephalic artery and the common carotid arteries were visualized in 3 cases. Increased uptake of the subclavian artery was found in 3 patients and in 4 patients pathological uptake was noted in the ilio-femoral vessels. Of 34 vascular regions studied, 26 (76%) showed elevated FDG uptake. On transversal MR images vessel wall thickening and contrast enhancement of the thoracic aorta was found in 4 patients (ascending aorta/aortic arch: n=2; descending aorta: n=3; abdominal aorta: n=1). Additionally, vessel wall pathologies of the subclavian and the common carotid arteries could be shown in 1 patient and in another patient in the ilio-femoral arteries. No abnormalities were found using contrast-enhanced MR angiography. Of 28 vascular regions studied, 9 (32%) showed vasculitis on MRI. The FDG-PET is a suitable whole-body screening method in the primary diagnosis of early TA, especially in those cases with early disease that present with uncharacteristic symptoms such as FUO. Both MRI and MRA remain indispensable in the exact determination of the pathomorphological changes and in the documentation of complications such as stenosis, aneurismatic transformation and occlusion.

Aged↗

Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography.

The goal of this prospective study was to compare a full-field digital mammography system (FFDM) to a conventional screen-film mammography system (SFM) for the detection and characterization of microcalcifications. Fifty-five patients with 57 isolated microcalcification clusters were examined using a FFDM system (Senographe 2000D, GE Medical Systems, Milwaukee, Wis.) and a SFM system (Senographe DMR, GE Medical Systems, Milwaukee, Wis.). A conventional screen-film mammogram and a digital contact mammogram were obtained of each cluster. The image quality and the number of calcification particles were evaluated, and a characterization (BI-RADS 1-5) of microcalcifications was given by four experienced readers. Histopathology revealed 16 benign lesions (sclerosing adenosis, dysplasia, hamartoma, radial scar) in 15 patients and 21 malignant tumors (in situ carcinoma, invasive carcinoma) in 20 patients. Twenty patients had benign changes verified by long-term follow-up. Image quality of FFDM was assessed as superior to SFM in more than 50% of the cases. The FFDM showed more calcifications in 41% of all cases. Sensitivity and specificity for FFDM vs SFM were 95.2 vs 91.9% and 41.4 vs 39.3%, respectively. Moreover, FFDM demonstrated a higher diagnostic accuracy (deviation: 0.86 BI-RADS steps) compared with FSM (deviation 0.93 BI-RADS steps). The FFDM system with a 100- micro m pixel size provides better image quality than SFM in patients with mammographic microcalcifications. The FFDM has a higher sensitivity and a higher reliability in characterizing microcalcifications.

Breast Neoplasms↗

Classification of hypervascularized lesions in CE MR imaging of the breast.

The purpose of this paper is to define and evaluate a classification category for contrast-enhanced (CE) MR imaging of the breast based on the BI-RADS mammographic categories of the American College of Radiology. Using five evaluation criteria for MR findings (initial signal increase, post-initial signal behavior, shape, border, and contrast material distribution within enhancing tumors) 522 patients (1031 breasts) were analyzed. Scores were given from 0 to 8 points and classified into five categories (group I: 0 points, negative; group II: 1-2 points, benign; group III: 3 points, probably benign; group IV: 4-5 points, suspicious abnormality; group V: 6-8 points, highly suspicious for malignancy) to 265 focal hypervascularized breast lesions in 244 breasts (patient group A). These findings were correlated with histology or follow-up. Additionally, this classification was correlated to the contrast medium uptake within the parenchyma of the remaining 787 breasts without any focal lesion (patient group B). Two hundred sixty-five hypervascularized lesions in 238 patients (244 breasts, patient group A) were classified into group I: 0%; group II: 27.3%; group III: 22.3%; group IV: 18.6%; and group V: 31.8%. Histology revealed 115 benign and 134 malignant tumors in these groups. Sixteen benign lesions were controlled by follow-up. Sensitivity for the detection of malignancy using the presented multifactorial MRM classification was 92%, and specificity was 92%. Excluding cases of ductal carcinoma in situ specificity increased to 95%. Seven hundred eighty-seven breasts without any focal hypervascularized lesion (patient group B) were classified into groups I or II. Follow-up ( n=771) or histology ( n=14) confirmed the diagnosis in 785 of these breasts. Histopathology revealed, however, malignant tumors in the remaining two cases. The classification of lesions based on a multifactorial analysis is very helpful in the interpretation of CE MRI of the breast. The evaluation of all diagnostic imaging modalities, however, is essential in determining the correct diagnosis and/or in deciding on the appropriate therapeutic procedure.

Breast↗

[Quality management in a radiology department].

PURPOSE: To increase the quality of internal and external interactions (patients, clinical colleagues, technicians, radiologists) in a department of radiology. METHOD: Accompanied by a well-experienced adviser workshops have been performed dealing with different topics like "contact to patients," "performance of the radiological report and interaction with the referring colleague" or "research and teaching." A catalogue of different actions was defined to reduce hindrances within the internal and external work-flow. RESULTS: A total number of 53 actions was defined and related to different persons who were responsible for the realisation of the measures within a time interval. Six months after starting the quality management 46 (86%) of the defined actions were realised successfully, and another 4 (8%) measures were still running. There was a moderate increase of satisfaction of the patients and clinical colleagues considering the waiting time. CONCLUSIONS: A quality management in a radiological department allows an optimisation of the internal and external interactions. However, the guidance of a well-experienced adviser is as essential as the continuous control of successful finished measures.

Education↗

Preoperative local MRI-staging of patients with a suspected pancreatic mass.

The aim of this study was to define the value of MRI of the pancreas for preoperative local staging of patients with a suspected pancreatic mass. Ninety-four patients (41 women, 53 men; age range 32-87 years) with a suspected pancreatic tumor underwent preoperative staging with MRI on a 1.5-T system. The MRI protocol included breath-hold MR cholangiopancreatography in turbo spin-echo technique, biphasic contrast-enhanced 3D MR angiography, and MRI of the upper abdomen with breath-hold T2-weighted half-Fourier acquired single-shot turbo spin-echo and T1-weighted fast-low-angle-shot (pre- and postcontrast) sequences. Data were collected prospectively and analyzed by two radiologists in agreement modality. Evaluation criteria were vascular involvement, resectability, and a characterization benign vs malignant. Results were compared to histopathology in 78 patients. Sixteen patients were followed-up. In 74 of 94 patients a solid tumor or an inflammation of the pancreas ( n=62) or the papilla ( n=12) was detected. In this group, MRI had a sensitivity of 98%, a specificity of 92%, and an accuracy of 96% in the characterization of malignant tumors. Regarding only the solid tumors, the positive predictive value of MRI was 87% with respect to resectability. Other pathologic findings included adenoma or inflammation of the duodenum ( n=5), carcinoma or benign stenosis of the choledochus duct ( n=7) and carcinoma of the gall bladder ( n=2). In 6 patients MRI did not depict any pathologic findings, and follow-up confirmed this interpretation. Magnetic resonance imaging allows a local preoperative staging in patients with suspected pancreatic tumor. Limitations, however, concern to the diagnostics of peritoneal and/or liver metastases.

Adult↗

Contrast-enhanced MR angiography of abdominal vessels: is there still a role for angiography?

The purpose of this review article is to describe recent advantages in contrast-enhanced (CE) three-dimensional (3D) magnetic resonance angiography (MRA) in comparison with other vascular imaging techniques, and to discuss their current clinical applications for the imaging of abdominal vessels. Principles and technical considerations are presented and clinical applications are reviewed for different vascular diseases. In ruptured aortic aneurysms and acute dissections CT is the method of first choice. Contrast-enhanced 3D MRA can be well used for therapeutic planning and follow-up in patients with stable disease. A comprehensive MR examination including CE 3D MRA, MR urography and MR nephrogram has the potential to replace the conventional studies for the evaluation of renal vascular disease. It is an accurate method for imaging the origins of coeliac and superior mesenteric arteries, although the image resolution is too low for reliable assessment of the inferior mesenteric artery. Contrast-enhanced 3D MRA has emerged as the method of choice for studying the portal venous system in liver transplant recipients, in patients with portal hypertension and in cases with abdominal tumours for preoperative evaluation. Additional non-invasive flow measurements are useful in monitoring portal hypertension. The abdominal veins can be well imaged using unenhanced MR techniques. Imaging may be facilitated with intravascular contrast media. Contrast-enhanced 3D MRA can replace intra-arterial DSA for diagnosis, therapy planning and follow-up in patients with abdominal vascular disease. Catheter-based arteriography will still be used for interventional procedures such as percutaneous transluminal angioplasty, stent placement and embolisation.

Abdomen↗

[MR-angiography in portal hypertension. State of the art].

When imaging the portal vascular system colour-coded sonography and CT angiography are used as an alternative to intraarterial DSA. Today fast CE 3D-MRA is the imaging modality of choice in the diagnostic of patients with portal hypertension. It enables a clear picture of the portalvenous vascular system and portalsytemic shunts. Statements regarding velocity and direction of blood flow can be made with additional use of TOF and PC techniques. CE-3D MRA can be used preoperatively before liver transplantation or shunt surgery. In the follow-up of interventional or surgical procedures exact statements concerning haemodynamically significant pathologies e.g. vascular thromboses, stenoses and occlusions can be made. Patient consent is symplify and the numbers of complications can be reduced as well as duration of surgery minimized applying this technique.

Collateral Circulation↗

[Intramural hematomas of the aorta].

Intramural hematomas (IMH) are regarded as a hemorrhage into the aortic wall. In general a traumatic form can de differentiated from a spontaneous non-traumatic. There is a predisposition of IMH with arterial hypertension and mesoectodermal dysplastic syndromes. The diagnosis is established with the clinical presentation in combination with the findings of different imaging modalities. Acute and subacute discomfort associated with a tendency of collaps are considered as typical presenting complaints. A semicircular or concentric thickening of the aortic wall with the absence of blood flow or a dissection membrane are typical findings in transesophageal echocardiography, computed tomography and magnetic resonance tomography. From a differential diagnostic point of view a distinction from atherosclerotic wall changes, intraluminal thrombi and inflammatory aortic diseases is essential. The IMH is considered as an early presentation of aortic dissection, put into and treated according to the Stanford classification. In the course of natural history an IMH can disappear, rupture or progress into a classic aortic dissection.

Aortic Dissection↗

[Experimental evaluation of vessel diameter from 0.3 to 8 mm in CE MR angiography].

PURPOSE: To evaluate the detection rate of vascular stenosis in contrast-enhanced 3D MR angiography using a flow phantom. MATERIAL AND METHODS: The examinations were performed on a 1.5 T whole body imaging system (Magnetom Symphony/Quantum) with 30 mT/m gradient field strength using a body-phased-array coil. Different 3D sequences (TR/TE/FA < 5 ms/< 2 ms/25 degrees ) with slice thicknesses ranging from 0.67 to 1.25 mm were applied. A gelantine-filled plastic cylinder with PVC tubes of 8 mm diameter was used as a vascular phantom. The tubes had concentric and excentric stenoses (50 - 90 %) of different lengths. For the detection of different vessel diameters another phantom with 0.3 - 8 mm silicon tubes was used. Both systems were flushed with a solution of Gd-DTPA (0.15 mmol/l) and saline at flow rates from 50 to 200 cm/s. The phantoms were positioned 0 degrees, 45 degrees, and 90 degrees towards the z-axis. RESULTS: The degree of stenosis was under- and overestimated in less than 10 %. The sequence with the highest spatial resolution provided the best results. Detection and evaluation of tubes >/= 2 mm proved to be reliable. CONCLUSION: Contrast-enhanced 3D MR angiography provides an almost exact evaluation of the degree of stenosis in the phantom study. Evaluation of vessel diameters < 2 mm is not possible.

Arterial Occlusive Diseases↗

3D MR angiography of the entire aorta: modified application of the body-phased array coil for a single-shot technique.

OBJECTIVE: Evaluation of different contrast-enhanced MR angiography imaging protocols for visualization of the entire aorta in breath-hold technique. METHODS AND PATIENTS: Three different CE (0.15 mmol/kg) MRA protocols were evaluated by phantom and patient studies: (1) two separate MRA with conventional application of the body-phased array coil; (2) a single-shot MRA with modified application of the body-phased array coil; (3) a single-shot MRA with the body coil. Duplex sonography, CTA and DSA were used as standard of reference. RESULTS: In all examinations the entire aorta could be visualized. The best SNR was acquired with protocol (1). The SNR of protocol (2) was reduced if the sagittal body diameter of the patient was greater than 20 cm and decreased significantly with diameters over 30 cm. By the use of protocol (3) the SNR was notably poor. The quality scored for the visualization of the entire aorta was 97.5% (protocol 1); 92.5% (protocol 2); and 80.0% (protocol 3). CONCLUSION: In most cases the modified application of the body-phased array coil allows the imaging of the entire aorta as a single-shot 3D CE MRA in diagnostic quality.

Adolescent↗

[Stent artifacts in 3D MR angiography: experimental studies].

PURPOSE: The purpose of this phantom study was to evaluate the visualization of vascular stents by using contrast-enhanced (CE) 3D MR angiography (MRA). METHODS: The measurements were performed on a Magnetom Vision operating at 1.5 T with 25 mT/m gradients by using a head coil; a 3D FISP sequence (TR/TE/FA 4.6 ms/1.8 ms/30 degrees) was used. A phantom was designed with a length of 20 cm and consisted of a plastic cylinder filled with hydrogel. Tubes were used to install 7 different stents (Strecker, Boston Scientific; Cragg, Mintec; Wall, Schneider; Memotherm, Angiomed; St-Come, Trigon-MTS; Sinus, Optimed; Palmaz, Johnson & Johnson) with different metal components. The tubes were perfused with a solution of water and Gd-DTPA. Four radiologists evaluated the image quality. The measurements of the endoluminal stent diameters were compared with the findings obtained by digital subtraction angiography. The signal intensities were measured before (inflow), within (stent) and after (outflow) the different stent types. RESULTS: The endoluminal diameter of the Cragg stent and the strecker graft were easily detectable. The signal loss within the lumen of the Wall stent was approx. 10% in relation to the inflow and outflow measurements. The result was an only slightly reduced image quality. The other grafts (St-Come, Sinus, Palmaz, Memotherm) showed significant signal losses ranging from 65% to 96%. A correct diagnosis was not possible within these graft lumina. CONCLUSION: Contrast-enhanced MR angiography can be used to evaluate vascular stents. A prerequisite is the application of particular commercially available grafts.

Angiography, Digital Subtraction↗

[The radial scar in contrast media-enhanced MR mammography].

INTRODUCTION: In patients with the mammographic findings of a radial scar, contrast enhanced (CE) MR mammography was evaluated in a retrospective study. MATERIAL AND METHODS: In 24 women with radial opacities and black star configurations, CE MR mammography was performed. Examinations were done on a 1.5 T system using bilateral superficial coil (2D technique, T1-weighted FLASH-sequence, TR 336 ms, TE 5 ms, FA 90 degrees). Findings in mammography and MR mammography were compared with the histological results. RESULTS: 15 radial scars (including 4 with additional ADH) and 9 carcinomas (6 in coexistence with a radial scar) presenting with a diameter of 3 mm to 13 mm were evaluated. There was no evidence of malignancy in MRI in 12 of 15 radial scars. In MR mammography 6 of the carcinomas fulfilled the criteria for malignant tumors. There were 3 borderline cases (scored 3 points) corresponding histologically to 1 radial scar, and to 2 carcinomas. Within the results found in MRI there were 2 false positives and 1 false negative. CONCLUSION: CE MR mammography is superior to other imaging modalities in the differentiation between radial scars and carcinomas. However, lesions suggestive of radial scars have to be removed surgically.

Adult↗