PubMed Health⌕ Search

Biomedical subjects

R W Mankin

Publications and source records attributed to R W Mankin.

12 recordsLinked to original sources

Geophone detection of subterranean termite and ant activity.

A geophone system was used to monitor activity of subterranean termites and ants in a desert environment with low vibration noise. Examples of geophone signals were recorded from a colony of Rhytidoponera taurus (Forel), a colony of Camponotus denticulatus Kirby, and a termite colony (undetermined Drepanotermes sp.) under attack by ants from a nearby C. denticulatus colony. The geophone recordings were compared with signals recorded from accelerometers in a citrus grove containing Solenopsis invicta Buren workers. Because of their small size, all of these insects produce relatively weak sounds. Several different types of insect-generated sounds were identified in the geophone recordings, including high-frequency ticks produced by R. taurus and C. denticulatus, and patterned bursts of head bangs produced by Drepanotermes. The S. invicta produced bursts of ticks with three different stridulation frequencies, possibly produced by three different-sized workers. Overall, both systems performed well in enabling identification of high-frequency or patterned pulses. The geophone was more sensitive than the accelerometer to low-frequency signals, but low-frequency insect sound pulses are more difficult to distinguish from background noises than high-frequency pulses. The low cost of multiple-geophone systems may facilitate development of future applications for wide-area subterranean insect monitoring in quiet environments.

Acoustics↗

Microwave radar detection of stored-product insects.

A microwave radar system that senses motion was tested for capability to detect hidden insects of different sizes and activity levels in stored products. In initial studies, movements of individual adults or groups of Lasioderma serricorne (F.), Oryzaephilus surinamensis (L.), Attagenus unicolor (Brahm), and Tribolium castaneum (Herbst) were easily detected over distances up to 30 cm in air. Boxes of corn meal mix and flour mix were artificially infested with 5-100 insects to estimate the reliability of detection. The likelihood that a box was infested was rated by the radar system on a quantitative scale. The ratings were significantly correlated with the numbers of infesting insects. The radar system has potential applications in management programs where rapid, nondestructive targeting of incipient insect infestations would be of benefit to the producers and consumers of packaged foods.

Animals↗

Broadcasts of wing-fanning vibrations recorded from calling male Ceratitis capitata (Diptera: Tephritidae) increase captures of females in traps.

Female Mediterranean fruit flies, Ceratitis capitata (Wiedemann), from the sterile-male rearing facility in El Pino, Guatemala, were exposed to broadcasts of wing-fanning vibrations recorded from males engaged in calling behavior to investigate the feasibility of developing a female-selective acoustic trap. The recorded signals had frequent amplitude fluctuations and peak frequencies approximately 350 Hz, typical of signals observed in previous studies of Mediterranean fruit fly acoustic behavior. Females did not exhibit long-distance phonotaxis, but remained near a speaker significantly longer when the sounds were broadcast at 103-107 dB than when the speaker was silent. In addition, significantly higher percentages of females were captured by yellow adhesive traps next to a broadcasting speaker than by traps next to a silent mimic. Additional bioassays were conducted with synthetic, 350-Hz tones produced by a thermoacoustic tube as well as with silent mimics of the different sound sources to examine the relative responsiveness of female Mediterranean fruit flies to traps with different acoustic and visual features. The visual attributes of the different sound source assemblies significantly affected capture rates. The range over which the broadcast significantly increased the percentage of female captures was <0.5 m, which may limit the utility of these acoustic cues in large-scale trapping programs. However, the findings of this study do justify further testing of whether optimized short-range acoustic signals could be used to augment longer range pheromonal and visual cues to improve the efficacy of female-selective traps.

Acoustics↗

Acoustic detection of termite infestations in urban trees.

A portable, low-frequency acoustic system was used to detect termite infestations in urban trees. The likelihood of infestation was rated independently by a computer program and an experienced listener that distinguished insect sounds from background noises. Because soil is a good insulator, termite sounds could be detected easily underneath infested trees, despite the presence of high urban background noise. Termite sounds could be detected also in trunks, but background noise often made it difficult to identify termite signals unambiguously. High likelihoods of termite infestation were predicted at four live oak (Quercus virginiana Mill, Fagacae), two loblolly pine (Pinus taeda L., Pinacae), and two baldcypress (Taxodium distichum Rich. Pinacae) trees that wood-baited traps had identified as infested with Coptotermes formosanus Shiraki. Infestations also were predicted at two pine trees with confirmed recoveries of Reticulitermes flavipes (Kollar). Low likelihoods of infestation were predicted in four oak trees where no termites were found. Additional tests were conducted in anechoic environments to determine the range of acoustic detectability and the feasibility of acoustically estimating termite population levels. There was a significant regression between the activity rate and the number of termites present in a wood trap block, with a minimum detectable number of approximately 50 workers per liter of wood. The success of these field tests suggests that currently available acoustic systems have considerable potential to detect and monitor hidden infestations of termites in urban trees and around building perimeters in addition to their present uses to detect and monitor termite infestations in buildings.

Acoustics↗

Acoustic surveying of subterranean insect populations in citrus groves.

Subterranean insect pests cause considerable economic damage but their concealment makes detection difficult. A portable acoustic system was developed and tested for its potential to rate the likelihood that trees in citrus groves were infested with Diaprepes abbreviatus (L.) larvae. The likelihood was rated independently by a computer program and an experienced listener that distinguished insect sounds from background noises. Diaprepes abbreviatus, Phyllophaga spp., or other pest insects were excavated from all 11 sites rated at high likelihood of infestation but were absent from 20 of 25 low-rated sites. There was a significant regression between the activity rate and the number of pest organisms present at recording sites although the correlation was weaker than between activity rate and likelihood of infestation. Although the system is at an early stage of development, the success of these field tests suggests that it has considerable potential as a tool to detect and monitor hidden infestations of insects in soil.

Animals↗

Mapping of soil insect infestations sampled by excavation and acoustic methods.

Geostatistical analysis was used to map traditionally and acoustically sampled populations of soil invertebrates at two different times in a hayfield at Grove Hill, AL, and once in an Auburn, AL, hayfield. The distributions of nearly all the soil invertebrates and their sounds were nonrandom in all three mapping studies. The maps constructed by excavation and acoustic sampling methods were compared by correlating the estimated (kriged) soil invertebrate counts with the estimated (kriged) counts of sounds per minute (pulse rate). Acoustic and traditional estimates were positively correlated in the Auburn study. Kriged estimates for green June beetle grub counts overlapped significantly with kriged estimates of sound pulse rate (R2 = 0.47). Overlap with sound pulse rates increased slightly when other soil organisms were counted along with green June beetle grubs: estimates of sound pulse rates were significantly correlated with counts of all white grubs (R2 = 0.50), all white grubs with earthworms (R2 = 0.52), all white grubs with earthworms and earwigs (R2 = 0.59), and total invertebrates (R2 = 0.59). The correlation between acoustic and traditional estimates was not significant at Grove Hill in either year, possibly because of a lack of experience in signal analysis or because the soil invertebrates may not have generated enough sounds to be detected above the background noise levels. These results suggest that acoustic technology is a promising tool for detecting insect pests in soil, but that further study and additional analysis are needed to improve interpretation of acoustic data obtained in the field.

Acoustics↗

Eavesdropping on insects hidden in soil and interior structures of plants.

Accelerometer, electret microphone, and piezoelectric disk acoustic systems were evaluated for their potential to detect hidden insect infestations in soil and interior structures of plants. Coleopteran grubs (the scarabaeids Phyllophaga spp. and Cyclocephala spp.) and the curculionids Diaprepes abbreviatus (L.) and Otiorhynchus sulcatus (F.) weighing 50-300 mg were detected easily in the laboratory and in the field except under extremely windy or noisy conditions. Cephus cinctus Norton (Hymenoptera: Cephidae) larvae weighing 1-12 mg could be detected in small pots of wheat in the laboratory by taking moderate precautions to eliminate background noise. Insect sounds could be distinguished from background noises by differences in frequency and temporal patterns, but insects of similarly sized species could not be distinguished easily from each other. Insect activity was highly variable among individuals and species, although D. abbreviatus grubs tended to be more active than those of O. sulcatus. Tests were done to compare acoustically predicted infestations with the contents of soil samples taken at recording sites. Under laboratory or ideal field conditions, active insects within approximately 30 cm were identified with nearly 100% reliability. In field tests under adverse conditions, the reliability decreased to approximately 75%. These results indicate that acoustic systems with vibration sensors have considerable potential as activity monitors in the laboratory and as field tools for rapid, nondestructive scouting and mapping of soil insect populations.

Acoustics↗

Monitoring insect pests in retail stores by trapping and spatial analysis.

Stored-product insects are a perennial problem in retail stores, where they damage and contaminate susceptible merchandise such as food products and animal feed. Historically, pest management in these stores has relied heavily on chemical insecticides, but environmental and health issues have dictated use of safer methods, and these require better monitoring. A monitoring procedure that employs an array of moth and beetle traps combined with spatial (contour) analysis of trap catch was tested in three department stores and two pet stores. The rate of capture increased with the level of infestation but was essentially constant over 4- to 5-d trapping periods. Contour analysis effectively located foci of infestation and reflected population changes produced by applications of the insect growth regulator (S)-hydroprene. The most abundant insects were Plodia interpunctella (Hiibner), Lasioderma serricorne (F.), Oryzaephilus mercator (Fauvel), Tribolium castaneum (Herbst), and Cryptolestes pusillus (Schönherr). The results indicate that contour analysis of trap counts provides a useful monitoring tool for management of storage pests in retail stores. It identifies trouble spots and permits selection, timing, and precision targeting of control measures to achieve maximum pest suppression with minimum pesticide risk. It permits managers and pest control operators to visualize pest problems over an entire store, to monitor changes over time, and to evaluate the effectiveness of control intervention. The contour maps themselves, along with records of control applications and stock rotation, provide permanent documentation of pest problems and the effectiveness of pest management procedures.

Animals↗

Thermal treatments to increase acoustic detectability of Sitophilus oryzae (Coleoptera: Curculionidae) in stored grain.

Hidden infestations of stored-product insect larvae are detected most rapidly by acoustic techniques when the larvae are highly active. Larval activity is periodic, however, and it tends to decrease after the larvae are disturbed or cooled. Because of the practical need for rapid inspection of grain at commercial elevators, several heat treatments were tested as potential methods of increasing larval activity and improving the speed and reliability of acoustic detection under adverse conditions. Samples of grain infested with 4th instars of Sitophilus oryzae (L.) were exposed to different radiant and convective heat treatments after they had been conditioned at 11 degrees C, 17 degrees C, or room temperature for 12-24 h. Relative activity levels were evaluated over periods of 0-12 h based on the mean levels in a 15-min interval, 2 h after the beginning of a trial. In comparisons among treatments with precooled larvae, relative activity levels 5-10 min after brief heat pulses were 2-30 times higher than activity levels in precooled controls exposed only to ambient temperatures (25 degrees C). After 15-25 min, the relative activity levels of these heated larvae remained 2-5 times higher than those of the ambient controls. Brief movement disturbances inhibited activity for approximately 20 min at any temperature. These results suggest that, in general, larval detectability is enhanced if cool grain samples are warmed and all samples are left undisturbed for 15-20 min before inspection.

Animals↗

Acoustical detection of Aedes taeniorhynchus swarms and emergence exoduses in remote salt marshes.

Swarms and emergency exoduses of Aedes taeniorhynchus mosquitoes produce sounds detectable from 10 to 50 m in a quiet environment. Background noise levels as low as 21 dB (decibels referenced to 20 microPa) are present at dusk between frequencies of 0.3 and 3.4 kHz. A mosquito swarm with a sound pressure level of 25-35 dB is detectable over tens of meters in the marsh, if not in the 40-60-dB background noise of a typical urban environment. Individually caged Ae. taeniorhynchus also are detectable, but only with 2-5-cm distances where the sound pressure level rises to 22-25 dB. These differences between signal and noise levels indicate that it is technologically feasible to construct an acoustical device for remote surveillance of large swarms or emergence exoduses of Ae. taeniorhynchus. This device could also detect nearby individuals attracted to a bait. Such a device can distinguish males from females by their wingbeat frequencies (700-800 Hz vs. 400-500 Hz).

Aedes↗

A microcomputer-controlled response measurement and analysis system for insect olfactory receptor neurons.

A microcomputer system has been built to stimulate, record, and analyze responses from peripheral insect olfactory receptor neurons. Software has been developed to sort action potentials (spikes) in extracellular records obtained from multi-innervated antennal sensilla, and perform frequency, interspike interval, distributional, and regression analyses on responses in groups of records. The olfactory stimuli can be presented in different patterns, and plots or histograms of analyses, spike records, and individual spikes can be displayed in different formats and hard-copied during a recording session. This report describes the main features of the system and discusses the methods used for sorting spikes, performing analyses, and managing records and analyses in a database. Examples are given of renewal density analyses for 4 classes of peripheral receptor neuron in records from 2 types of olfactory sensillum on the antenna of the cabbage looper moth, Trichoplusia ni (Hübner).

Action Potentials↗

A phenomenological model of the perceived intensity of single odorants.

The response of a model olfactory system to a single odorant is quantified by interconnecting three separate stimulus-response relationships. Together, these relationships encompass the deposition of odorant molecules onto an olfactory organ, their movement to the dendrite of the olfactory receptor neuron, their subsequent induction of action potentials, and the processing of induced and spontaneous action potentials by the central nervous system, resulting in perception and a behavioral response. Phenomena discussed within the context of the model include the behavioral threshold, central summation of responses from a number of olfactory neurons, and the effect of organ shape on olfactory detection. The intent of the model is to provide a quantitative conceptual framework for designing and interpreting experiments relating sensory input to perception and behavior. Its utility is particularly evident for insect olfaction since it enables insect sex pheromone behavioral thresholds to be estimated from the literature when bioassays or electrophysiological studies are not possible. It also derives a physiologically meaningful method for comparing behavioral thresholds among different animals, and permits comparisons of different kinds of behavioral responses in the same species. Vertebrate olfaction is treated briefly in a discussion of the effect of sniffing on the threshold of detection.

Action Potentials↗