PubMed Health⌕ Search

Biomedical subjects

R W Smalling

Publications and source records attributed to R W Smalling.

At least 37 records · Page 2Linked to original sources

Pharmacological and clinical impact of the unique molecular structure of a new plasminogen activator.

Thrombolytic therapy has been recognized as a significant improvement in the management of acute myocardial infarction. Thrombolytic agents however have been limited by short half-lives that necessitate complex administration protocols and by the potential for bleeding complications. The native t-PA molecule has since been modified in an attempt to achieve improved lytic characteristics with less risk of bleeding. Reteplase is a third-generation recombinant mutant of tissue-type plasminogen activator (t-PA) that is expressed in Escherichia coli cells and consists of the kringle 2 and the protease domains of t-PA. Compared with t-PA, reteplase has a lower fibrin binding, which may translate to improved clot penetration. As well as a longer half-life and a more rapid initiation of thrombolysis. Preclinical pharmacology studies have indicated that reteplase has potent in vivo thrombolytic activity and leads to rapid reperfusion; these findings have been confirmed by promising results obtained in large-scale clinical trials. Other new agents developed by modifying the native t-PA molecule include the n-PA and the TNK mutants of t-PA. These novel, genetically modified thrombolytic agents all lyse clots better than the native t-PA; however, they differ with respect to their half-lives and fibrin-binding activity. Although all the third-generation thrombolytic agents have shown considerable potential in improving the efficacy of thrombolytic therapy, their risk of intracranial bleeding remains problematic and is still somewhat uncertain.

Amino Acid Sequence↗

Clinical trial results with a new plasminogen activator.

Thrombolysis has become an accepted form of therapy for acute myocardial infarction. As demonstrated in the Global Utilization of Streptokinase and t-PA for Occluded Arteries trial, early, complete and sustained patency of the infarct-related coronary artery is correlated with reduced mortality. However, current thrombolytic regimens are able to achieve such patency within 90 min in only 81% of cases. To improve the risk/benefit ratio of thrombolytic therapy, newer agents such as reteplase have been developed to establish more rapid, more complete and more stable coronary artery patency, thus reducing mortality. This report summarizes the pharmacological properties of reteplase. It also summarizes the findings from various animal and clinical studies in which reteplase was compared with alteplase and streptokinase and the findings from animal and clinical studies evaluating infusion, single-bolus, double-bolus, doses of reteplase.

Amino Acid Sequence↗

Molecular biology of plasminogen activators: what are the clinical implications of drug design?

The initial work on thrombolytic therapy for acute myocardial infarction (AMI) focused on intracoronary administration of streptokinase. Continuing research has given rise to the development of both second- and third-generation agents and consequent refinements in thrombolytic regimens. Intravenous recombinant tissue plasminogen activator (t-PA, or alteplase) proved superior to both intracoronary and intravenous streptokinase with regard to reperfusion efficacy and impact on survival. An accelerated dosage regimen was later devised to allow the administration of t-PA over a shorter period of time. Unfortunately, t-PA failed to lessen the risk of bleeding complications that had plagued the use of streptokinase. The wild-type t-PA molecule has since been modified in an attempt to achieve improved lytic characteristics with less bleeding risk. Among these third-generation agents is reteplase (r-PA); compared with alteplase, reteplase has a prolonged half-life and seems to offer more rapid thrombolysis. Promising results have been obtained in large, randomized trials of reteplase. Another new agent is the TNK mutant of t-PA, which also has a prolonged half-life and seems to produce more rapid and complete thrombolysis, as well as less risk of intracranial bleeding than with alteplase in animal models. Although large, randomized trials have not yet been conducted, encouraging results have emerged from preliminary dose-ranging trials with TNK. A third new agent, n-PA, has an even longer half-life and has shown improved lytic activity in animal models. A dose-ranging trial of n-PA is currently under way. Despite the fact that each of the third-generation drugs has shown considerable potential with regard to improving the efficacy of thrombolytic therapy, the risk of intracranial bleeding remains problematic and will need to be assessed in large, randomized trials.

Animals↗

Patency trials with reteplase (r-PA): what do they tell us?

Thrombolytic therapy has been shown to reduce mortality and morbidity after acute myocardial infarction. Therapeutic benefit seems to be directly correlated with completeness of reperfusion (Thrombolysis in Myocardial Infarction [TIMI] grade 3 flow) of the infarct-related coronary artery, as well as the timeliness of reperfusion. To determine which regimen of reteplase (r-PA), a deletion mutant of wild-type tissue plasminogen activator (t-PA), is most effective for clinical thrombolysis, several reteplase regimens were compared with the most successful standard regimens of recombinant t-PA (alteplase) in 2 large-scale, randomized studies. All patients received aspirin and intravenous heparin. In the Reteplase Angiographic Phase II International Dose Finding Trial (RAPID-1), results in 606 randomized patients showed that a 10 + 10 U double bolus of reteplase was more effective than a 15 U single bolus, a 10 + 5 double bolus, or conventional alteplase (100 mg over 3 hours). In the Reteplase versus Alteplase Patency Investigation During Acute Myocardial Infarction (RAPID-2) trial, results in 324 patients showed that significantly more patients achieved patency of the infarct-related artery (TIMI grade 2 or 3 flow) at 90 minutes with reteplase (10 + 10 U double bolus) than with accelerated alteplase (100 mg over 90 minutes): 83.4% versus 73.3%, respectively (p = 0.03). The incidence of complete patency (TIMI grade 3 flow) at 90 minutes was likewise greater with reteplase than with accelerated alteplase (59.9% vs 45.2%, respectively; p = 0.01). At 60 minutes, the incidence of TIMI grade 2 or 3 flow was also significantly higher with reteplase than with alteplase (81.8% vs 66.1%, respectively; p = 0.01), as was the incidence of TIMI grade 3 flow (51.2% vs 37.4%, respectively; p < 0.031). The 35-day mortality rate was 4.1% for reteplase and 8.4% for alteplase (p = not significant). Reteplase and alteplase did not differ significantly with regard to the occurrence of severe bleeding (12.4% vs 9.7%, respectively) or hemorrhagic stroke (1.2% vs 1.9%, respectively). The results of these trials show that reteplase, given as a 10 + 10 U double bolus, achieves significantly higher rates of early reperfusion of the infarct-related coronary artery and is associated with significantly fewer acute coronary interventions when compared with front-loaded alteplase. The benefits of reteplase are achieved without any apparent increased risk of complications.

Cerebral Hemorrhage↗

Randomized comparison of coronary thrombolysis achieved with double-bolus reteplase (recombinant plasminogen activator) and front-loaded, accelerated alteplase (recombinant tissue plasminogen activator) in patients with acute myocardial infarction. The RAPID II Investigators.

BACKGROUND: The therapeutic benefit of thrombolytic therapy has been shown to correlate directly with completeness (TIMI grade 3 flow) and speed of reperfusion of the infarct-related coronary artery. The purpose of the RAPID II study was to determine whether a double-bolus regimen of reteplase, a recently developed deletion mutant of wild-type tissue plasminogen activator, could improve 90-minute coronary artery patency rates achieved with the most successful standard regimen, an "accelerated" front-loaded infusion of alteplase. METHODS AND RESULTS: Three hundred twenty-four patients with acute myocardial infarction were randomized to receive (along with intravenous heparin and aspirin) either a 10 plus 10 megaunits double bolus of reteplase or front-loaded alteplase. The primary end point of "patency at 90 minutes, graded according to the TIMI classification" was centrally assessed in a blinded fashion. Infarctrelated coronary artery patency (TIMI grade 2 or 3) and complete patency (TIMI grade 3) at 90 minutes after the start of thrombolytic therapy were significantly higher in the reteplase-treated patients (TIMI grade 2 or 3: 83.4% versus 73.3% for front-loaded alteplase-treated patients, P = .03; TIMI grade 3: 59.9% versus 45.2%, P = .01). At 60 minutes, the incidence of both, patency and complete patency, was also significantly higher in reteplase-treated patients (reteplase versus alteplase, TIMI grade 2 or 3: 81.8% versus 66.1%, P = .01; TIMI grade 3: 51.2% versus 37.4%, P < .03). Reteplase-treated patients required fewer acute additional coronary interventions (13.6% versus 26.5%, P < .01), and 35-day mortality was 4.1% for reteplase and 8.4% for alteplase (P = NS). There were no significant differences between reteplase and alteplase in bleedings requiring a transfusion (12.4% versus 9.7%) or hemorrhagic stroke (1.2% versus 1.9%). CONCLUSIONS: Reteplase, when given as a double bolus of 10 plus 10 megaunits to patients with acute myocardial infarction, achieves significantly higher rates of early reperfusion of the infarct-related coronary artery and requires significantly fewer acute coronary interventions than front-loaded alteplase without an apparent increased risk of complications.

Adult↗

Coronary thrombi increase PTCA risk. Angioscopy as a clinical tool.

BACKGROUND: The presence of angiographically identified intracoronary thrombus has been variably associated with complications after coronary angioplasty. Angiography has been shown to be less sensitive than angioscopy for detecting subtle details of intracoronary morphology, such as intracoronary thrombi. The clinical importance of thrombi detectable by angioscopy but not by angiography is not known. METHODS AND RESULTS: Percutaneous coronary angioscopy was performed in 122 patients undergoing conventional coronary balloon angioplasty (PTCA) at six medical centers. Unstable angina was present in 95 patients (78%) and stable angina in 27 (22%). Therapy was not guided by angioscopic findings, and no patient received thrombolytic therapy as an adjunct to angioplasty. Coronary thrombi were identified in 74 target lesions (61%) by angioscopy versus only 24 (20%) by angiography. A major in-hospital complication (death, myocardial infarction, or emergency bypass surgery) occurred in 10 of 74 patients (14%) with angioscopic intracoronary thrombus, compared with only 1 of 48 patients (2%) without thrombi (P = .03). In-hospital recurrent ischemia (recurrent angina, repeat PTCA, or abrupt occlusion) occurred in 19 of 74 patients (26%) with angioscopic intracoronary thrombi versus only 5 of 48 (10%) without thrombi (P = .03). Relative risk analysis demonstrated that angioscopic thrombus was strongly associated with adverse outcomes (either a major complication or a recurrent ischemic event) after PTCA (relative risk, 3.11; 95% CI, 1.28 to 7.60; P = .01) and that angiographic thrombi were not associated with these complications (relative risk, 0.85; 95% CI, 0.36 to 2.00; P = .91). CONCLUSIONS: The presence of intracoronary thrombus associated with coronary stenoses is significantly underestimated by angiography. Angioscopic intracoronary thrombi, the majority of which were not detected by angiography, are associated with an increased incidence of adverse outcomes after coronary angioplasty.

Adult↗

Rotational atherectomy with a new device: initial clinical experience.

The Bard Atherectomy Catheter is a new rotational atherectomy device that consists of a flexible, hollow, thin-walled cutting catheter that, while rotated at 1,500 revolutions per minute, is advanced across the lesion over a special spiral guidewire system. We report the initial clinical experience with this device in 20 peripheral lesions in ten patients. The majority of patients were treated for limb salvage. All lesions were successfully intervened on by atherectomy followed by adjunctive balloon angioplasty. A reduction to less than 50% stenosis was achieved in 13 of the 20 lesions (65%) after atherectomy but in all 20 lesions (100%) after adjunctive angioplasty for all lesions and stenting for dissections in two. Baseline minimal lesion lumen diameter was 0.8 +/- 0.7 mm with a reference vessel diameter of 4.2 +/- 1.7 mm (75 +/- 21% stenosis). The lumen improved to 2.0 +/- 0.8 mm (45 +/- 19% stenosis) (P < 0.001) following atherectomy and to 3.9 +/- 1.9 mm (13 +/- 16% stenosis) (P < 0.001) after adjunctive angioplasty. The average weight of removed atheroma was 45 +/- 58 mg. All ten patients had initial improvement in symptoms. At 6 months follow-up there was persistent improvement in eight patients and two subjects had undergone amputations. Our early clinical experience with this low profile, flexible atherectomy device, that enables extraction of a large amount of atheroma, suggests that it will become a valuable addition to current atherectomy technologies in small- and medium-sized vessels. The value of this device in coronary vessels is under investigation.

Angioplasty, Balloon↗

Comparison of angioscopy, intravascular ultrasound imaging and quantitative coronary angiography in predicting clinical outcome after coronary intervention in high risk patients.

OBJECTIVES: The purpose of this study was to identify qualitative or quantitative variables present on angioscopy, intravascular ultrasound imaging or quantitative coronary arteriography that were associated with adverse clinical outcome after coronary intervention in high risk patients. BACKGROUND: Patients with acute coronary syndromes and complex lesion morphology on angiography are at increased risk for acute complications after coronary angioplasty. Newer devices that primarily remove atheroma have not improved outcome over that of balloon angioplasty. Intravascular imaging can accurately identify intraluminal and intramural histopathologic features not adequately visualized during coronary arteriography and may provide mechanistic insight into the pathogenesis of abrupt closure and restenosis. METHODS: Sixty high risk patients with unstable coronary syndromes and complex lesions on angiography underwent angioscopy (n = 40) and intravascular ultrasound imaging (n = 46) during interventional procedures. In 26 patients, both angioscopy and intravascular ultrasound were performed in the same lesion. All patients underwent off-line quantitative coronary arteriography. Coronary interventions included balloon (n = 21) and excimer laser (n = 4) angioplasty, directional (n = 19) and rotational (n = 6) atherectomy and stent implantation (n = 11). Patients were followed up for 1 year for objective evidence for recurrent ischemia. RESULTS: Patients whose clinical presentation included rest angina or acute myocardial infarction or who received thrombolytic therapy within 24 h of procedure were significantly more likely to experience recurrent ischemia after intervention. Plaque rupture or thrombus on preprocedure angioscopy or angioscopic thrombus after intervention were also significantly associated with adverse outcome. Qualitative or quantitative variables on angiography, intravascular ultrasound or off-line quantitative arteriography were not associated with recurrent ischemia on univariate analysis. Multivariate predictors of recurrent ischemia were plaque rupture on preprocedure angioscopy (p < 0.05, odds ratio [OR] 10.15) and angioscopic thrombus after intervention (p < 0.05, OR 7.26). CONCLUSIONS: Angioscopic plaque rupture and thrombus were independently associated with adverse outcome in patients with complex lesions after interventional procedures. These features were not identified by either angiography or intravascular ultrasound.

Angioplasty, Balloon, Coronary↗

Reduction of canine infarct size by bolus intravenous administration of liposomal prostaglandin E1: comparison with control, placebo liposomes, and continuous intravenous infusion of prostaglandin E1.

Prostaglandin E1 (PGE1) reduces experimental infarct size when administered by prolonged low-dose left atrial infusion during coronary occlusion. Liposomal delivery of PGE1 may enhance biologic activity and limit adverse hemodynamic effects. The purpose of this study was to test the hypothesis that intravenous bolus administration of liposomal PGE1 (TLC C-53, The Liposome Company, Princeton, N.J.) during coronary occlusion would result in myocardial salvage. We compared TLC C-53 (0.5 microgram/kg intravenous bolus at 10 and 100 min of occlusion of the left anterior descending coronary artery [LAD]), free PGE1 (0.1 microgram/kg/min infused 10 min after LAD occlusion until reperfusion), placebo liposomes, and control (n = 7 for each group) in an open-chest canine model of 2 hours of LAD occlusion and reperfusion. Infarct size as a percentage of risk area (mean +/- SD) in the control group (58.4% +/- 20.0%) was similar to that in animals given placebo liposomes (53.1% +/- 12.6%) but was significantly reduced in the groups given TLC C-53 (33.5% +/- 9.2%; p < 0.01) or free PGE1 (37.2% +/- 4.8%; p < 0.05) groups. Infarct salvage was significant (p < 0.05) for the TLC C-53-and PGE1-treated dogs compared with the control dogs, independent of collateral blood flow by analysis of covariance. Moreover, the ischemic-zone blood flow during reperfusion was significantly higher in the TLC C-53 group compared with the control group or the group receiving free PGE1. Neutrophil infiltration of ischemic myocardium was significantly inhibited by TLC C-53 as determined by myeloperoxidase assay. Unlike free PGE1, TLC C-53 did not cause significant tachycardia or hypotension during therapy. In conclusion, TLC C-53 administered intravenously during coronary occlusion significantly reduced infarct size, limited neutrophil infiltration, and improved myocardial blood flow during reperfusion without adverse hemodynamic consequences.

Alprostadil↗

Infarct salvage with liposomal prostaglandin E1 administered by intravenous bolus immediately before reperfusion in a canine infarction-reperfusion model.

BACKGROUND: Prostaglandin E1 (PGE1) inhibits leukocyte and platelet function and reduces infarct size during left atrial infusion. Intravenous liposomal PGE1 (TLC C-53) accelerates thrombolysis and prevents reocclusion in canine coronary thrombosis. We tested the hypothesis that intravenous TLC C-53 would attenuate reperfusion injury in a canine infarction-reperfusion model. METHODS AND RESULTS: Twenty-one open-chest dogs were randomized to receive a 10-minute intravenous infusion of either liposome diluent (placebo), free PGE1 (2 micrograms/kg), or TLC C-53 (2 micrograms/kg PGE1) after 2 hours of left anterior descending (LAD) occlusion just before reperfusion. Hemodynamic assessment, regional myocardial blood flow determination with radioactive microspheres, myocardial leukocyte infiltration by myeloperoxidase assay, and estimation of infarct size using triphenyl tetrazolium chloride staining were performed. Regional fractional shortening was measured with sonomicrometer crystals implanted in the midmyocardium. Infarct size as a percentage of the risk region was significantly reduced (P < .05) with TLC C-53 (37.9 +/- 17.4%) compared with PGE1 (56.7 +/- 13.9%) or placebo (58.0 +/- 9.9%) infusion. Infarct salvage with TLC C-53 was independent of collateral blood flow by ANCOVA. There was a dramatic reduction in myeloperoxidase activity in the infarct, risk, and border regions of dogs treated with TLC C-53 compared with placebo. Enzyme activity was also significantly reduced (P < .05) in the infarct zone with TLC C-53 (0.11 +/- 0.1 U/100 mg) treatment compared with PGE1 (0.38 +/- 0.3 U/100 mg). No significant differences in regional myocardial blood flow or myocardial function among treatment groups were identified, although there was a trend toward improved function in the TLC C-53 dogs. CONCLUSIONS: Bolus intravenous administration of TLC C-53 immediately before reperfusion results in reduced leukocyte infiltration and substantial infarct salvage. TLC C-53 mah be useful in limiting reperfusion injury during treatment of acute myocardial infarction.

Alprostadil↗

More rapid, complete, and stable coronary thrombolysis with bolus administration of reteplase compared with alteplase infusion in acute myocardial infarction. RAPID Investigators.

BACKGROUND: Early restoration and maintenance of normal (TIMI 3) blood flow during acute myocardial infarction is critical for optimal preservation of left ventricular function and survival. Recombinant plasminogen activator (r-PA, reteplase) is a nonglycosylated deletion mutant of wild-type tissue-type plasminogen activator (TPA) that has been shown to achieve more rapid and complete thrombolysis compared with other plasminogen activators in animal models. METHODS AND RESULTS: The RAPID Trial was designed to test the hypothesis that bolus administration of one or more dosage regimens of r-PA was superior to standard-dose alteplase (TPA) in achieving infarct-related artery patency 90 minutes after initiation of treatment. Six hundred six patients with acute myocardial infarction were randomized to one of four treatment arms: (1) TPA 100 mg i.v. over 3 hours, (2) r-PA as a 15-MU single bolus, (3) r-PA as a 10-MU bolus followed by 5 MU 30 minutes later, or (4) r-PA as a 10-MU bolus followed by 10 MU 30 minutes later. Coronary arteriography was performed at 30, 60, and 90 minutes after initiation of treatment and at hospital discharge. The 10 + 10-MU r-PA group achieved better 90-minute and 5- to 14-day TIMI 3 flow (63% [CI, 55% to 71%] versus 49% [41% to 57%], P = .019, and 88% [82% to 94%] versus 71% [63% to 79%], P < .001, respectively) than the TPA group. The TIMI 3 flow in the 10 + 10-MU r-PA group at 60 minutes was equivalent to that in the TPA group at 90 minutes (51 versus 49%). Global ejection fraction and regional wall motion in the 10 + 10-MU r-PA group were superior to those of the TPA group at hospital discharge (53 +/- 1.3% versus 49 +/- 1.3%, P = .034; -2.19 +/- 0.12 versus -2.61 +/- 0.13 SD per chord, P = .02, respectively). The 15-MU and 10 + 5-MU r-PA patency and left ventricular function results were similar to those of the TPA and inferior to those of the 10 + 10-MU r-PA group. Bleeding complications were similar between the groups. CONCLUSIONS: r-PA given as a double bolus of 10 + 10 MU achieves more rapid, complete, and sustained thrombolysis of the infarct-related artery than standard-dose TPA, without an apparent increased risk of complications. This was associated with improved global and regional left ventricular function at hospital discharge.

Coronary Angiography↗

Diffuse vasospasm following stenting of a free gastroepiploic artery graft: resolution with balloon angioplasty and intensive medical therapy.

Vasospasm following balloon angioplasty of gastroepiploic artery bypass grafts can be prevented or reversed with vasodilators. In our patient, stent deployment for ostial stenosis of a free gastroepiploic artery graft was accompanied by severe, diffuse spasm and a change in graft configuration that required both intensive medical therapy and balloon angioplasty for resolution.

Angioplasty, Balloon, Coronary↗

Successful treatment of chronic total peripheral occlusions that failed conventional techniques using the stiff backend of the Glidewire.

The vast majority of failures of transcatheter interventions in patients with peripheral vascular disease are due to inability to cross the lesion with a guidewire. Although the use of the Glidewire has clearly improved the success rate, failures with especially chronic total occlusions still occur. We describe a new technique using the very stiff backend of the Glidewire, which we have found very successful, when conventional techniques fall in crossing highly resistant lesions.

Aged↗

Coronary artery flow monitoring following coronary interventions.

Coronary guidewires with ultrasound transducer tips are commercially available and are appropriately sized for use in coronary interventions. These guidewires permit monitoring of coronary flow before, during and after the interventions. The measured flow signal contains valuable information regarding the quality and the stability of the final result. After completion of the procedure, monitoring the trend in average velocity over several minutes can reveal subtle alterations in flow that may presage abrupt closure. Abnormal or unstable flow patterns also may help predict lesions that might develop recurrences in the weeks and months after successful procedures.

Angioplasty, Balloon, Coronary↗

Coronary artery flow monitoring: the value of intravascular Doppler for detection of complications after interventions.

Ultrasound transducer-tipped guidewires can be used for coronary interventions, and they permit the monitoring of coronary flow before, during, and after the interventions. The flow signal contains valuable information regarding the quality and stability of the final result. Restoration of typical phasic flow patterns with diastolic predominance is one guide to final result. Monitoring the trend in average velocity over several minutes after completion of the procedure can detect subtle alterations in flow that may presage abrupt closure. These flow alterations might also help predict active plaques with heavy thrombus involvement that may undergo recurrence in the weeks and months after successful procedures.

Angioplasty, Balloon, Coronary↗

Transvalvular left ventricular assistance in acute myocardial infarction with cardiogenic shock and high risk angioplasty: experimental and clinical results with the Hemopump.

The Hemopump has been shown to be an effective left ventricular assist device. It is capable of supporting the circulation in patients with profound left ventricular dysfunction in the setting of cardiogenic shock. In experimental animals it seems possible that supporting the circulation immediately prior to reperfusion will produce a significant decrease in infarct size, which has important clinical ramifications, particularly in the setting of patients with large anterior myocardial infarction. The mechanism for this infarct salvage is unclear at the present time and requires further investigation, at a more basic level. The current tools available to the cardiologist include the intraaortic balloon pump and the cardiopulmonary support system (CPS), (PCs, BARD, Inc.). The Hemopump is available in Europe, but not in the United States at the present time. Clearly, the CPS system is the most powerful of the devices available, producing up to 61/m of flow. Unfortunately, there are a number of drawbacks with the CPS system, including its need for an oxygenator, which limits its useful period of support to approximately 8 hours. Additionally, support with the PCS system may be associated with adverse physiological events. The intraaortic balloon pump requires synchronization with the cardiac cycle, and hence, is not suitable for patients with significant tachyarrhythmias. Patients with overt cardiac arrest, similarly, cannot be supported with the intraaortic balloon pump. Nonetheless, the balloon pump has been associated with improved infarct salvage in an experimental animal model. On the other hand, the Hemopump, in its first version, required a surgical incision and placement of a graft onto the femoral artery.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary↗

Aggressive interventional treatment of acute myocardial infarction. Lessons from the animal laboratory applied to the catheterization suite.

Myocardial necrosis progresses with the duration of coronary occlusion in the early stages of acute myocardial infarction. Prompt recanalization of the infarct-related artery resulting in effective and sustained reperfusion of jeopardized myocardium is the goal of modern therapy. Clinical thrombolysis trials have demonstrated a significant survival advantage for treated patients, but only a modest recovery of global or regional systolic left ventricular function. Accelerated regimens of administering currently available thrombolytic agents are associated with early coronary patency rates approaching 85%, although effective coronary perfusion is restored in only slightly better than one half of patients treated. Primary angioplasty without antecedent thrombolytic therapy has resulted in high patency rates with superior coronary flow when performed in some experienced centers. Treatment of cardiogenic shock requires immediate mechanical or surgical intervention to reestablish coronary perfusion often following placement of a circulatory assistance device. Future trends toward very early initiation of thrombolytic therapy, improvements in adjunctive therapy and advances in the noninvasive detection of recanalization should permit selective use of aggressive interventional therapy for failed thrombolysis in a minority of patients with acute myocardial infarction.

Angioplasty, Balloon, Coronary↗