Comparison of diameter and perimeter methods for tumor volume calculation.

PURPOSE: Lesion volume is often used as an end point in clinical trials of oncology therapy. We sought to compare the common method of using orthogonal diameters to estimate lesion volume (the diameter method) with a computer-assisted planimetric technique (the perimeter method). METHODS: Radiologists reviewed 825 magnetic resonance imaging studies from 219 patients with glioblastoma multiforme. Each study had lesion volume independently estimated via the diameter and perimeter methods. Cystic areas were subtracted out or excluded from the outlined lesion. Inter- and intrareader variability was measured by using multiple readings on 48 cases. Where serial studies were available in noncystic cases, a mock response analysis was used. RESULTS: The perimeter method had a reduced interreader and intrareader variability compared with the diameter method (using SD of differences): intrareader, 1.76 mL v 7.38 mL (P < .001); interreader, 2.51 mL v 9.07 mL (P < .001) for perimeter and diameter results, respectively. Of the 121 noncystic cases, 23 had serial data. In six (26.1%) of those 23, a classification difference occurred when the perimeter method was used versus the diameter method. CONCLUSION: Variability of measurements was reduced with the computer-assisted perimeter method compared with the diameter method, which suggests that changes in volume can be detected more accurately with the perimeter method. The differences between these techniques seem large enough to have an impact on grading the response to therapy.

Brain↗

A signal estimation approach to functional MRI.

In the last half decade, fast methods of magnetic resonance imaging have led to the possibility, for the first time, of non-invasive dynamic brain imaging. This has led to an explosion of work in the Neurosciences. From a signal processing viewpoint the problems are those of nonlinear spatio-temporal system identification. In this paper, we develop new methods of identification using novel spatial regularization. We also develop a new model comparison technique and use that to compare our method with existing techniques on some experimental data.

Brain↗

Cocaine decreases cortical cerebral blood flow but does not obscure regional activation in functional magnetic resonance imaging in human subjects.

The authors used functional magnetic resonance imaging (fMRI) to determine whether acute intravenous (i.v.) cocaine use would change global cerebral blood flow (CBF) or visual stimulation-induced functional activation. They used flow-sensitive alternating inversion recovery (FAIR) scan sequences to measure CBF and blood oxygen level-dependent (BOLD) sensitive T2* scan sequences during visual stimulation to measure neuronal activation before and after cocaine and saline infusions. Cocaine (0.6 mg/kg i.v. over 30 seconds) increased heart rate and mean blood pressure and decreased end tidal carbon dioxide (CO2). All measures returned to baseline by 2 hours, the interinfusion interval, and were unchanged by saline. Flow-sensitive alternating inversion recovery imaging demonstrated that cortical gray matter CBF was unchanged after saline infusion (-2.4 +/- 6.5%) but decreased (-14.1 +/- 8.5%) after cocaine infusion (n = 8, P < 0.01). No decreases were detected in white matter, nor were changes found comparing BOLD signal intensity in cortical gray matter immediately before cocaine infusion with that measured 10 minutes after infusion. Visual stimulation resulted in comparable BOLD signal increases in visual cortex in all conditions (before and after cocaine and saline infusion). Despite a small (14%) but significant decrease in global cortical gray matter CBF after acute cocaine infusion, specific regional increases in BOLD imaging, mediated by neurons, can be measured reliably.

Adult↗

[Economic expansion and the health crisis in Paraguay].

In spite of the rapid economic development experienced by Paraguay during recent years, the country's health conditions remain among the poorest in Latin America. This article strives to explain, by presenting a model of Paraguay's economic and health care systems, why health care and economic growth have not advanced at the same rate. By examining various economic and health care indicators, hospital registries, family planning activities, and statistics on drinking-water and health care services distribution among central departments with established populations, as well as recently populated peripheral areas, the conclusion is reached that the country's poor health conditions might be the direct result of accelerated expansion of the agricultural frontier. In closing, recommendations are made for updating health statistics via new health survey, improved training for rural health care personnel, and closer coordination among the four public hospital systems in the cities.

Adolescent↗

Dynamic signal intensity changes in liver with superparamagnetic MR contrast agents.

The dynamic effects of three different superparamagnetic magnetic resonance (MR) contrast agents on liver signal were evaluated with an echo-planar imaging technique. The contrast agents were (a) USPIO (ultrasmall superparamagnetic iron oxide), which has a long blood half-life and was developed for MR imaging of lymph nodes and bone marrow; (b) AG (arabinogalactan)-USPIO, an asialoglycoprotein receptor--directed iron oxide with hepatocyte uptake; and (c) AMI-25, a conventional reticuloendothelial iron oxide agent. Dynamic liver signal intensity (SI) curves reflect different uptake mechanisms for the different agents. Receptor blocking experiments indicate that intracellular redistribution or clustering of the AG-USPIO (known to occur from electron microscopy studies) does not contribute to the decrease in liver SI. Monitoring liver SI over time with echo-planar imaging may provide a better understanding of the kinetics of the growing number of MR contrast agents and allow optimization of imaging protocols to exploit peak enhancement.