PubMed Health⌕ Search

Biomedical subjects

R Wirestam

Publications and source records attributed to R Wirestam.

26 records · Page 2Linked to original sources

The perfusion fraction in volunteers and in patients with ischaemic stroke.

The fractional volume of capillary blood, i.e. the perfusion fraction f, was measured with the aid of an echo-planar imaging protocol originally designed for the measurement of water diffusion. In healthy volunteers, reasonable f values were obtained. In patients with cerebral ischaemic stroke, a marked decrease in the f value was seen in the infarcted region as compared with corresponding values in the contralateral hemisphere. We suggest that perfusion-fraction measurements may add to the diagnostic value of water-mobility examinations in patients with ischaemic disease.

Adult↗

A computer simulation program for MR imaging: application to RF and static magnetic field imperfections.

A computer simulation program capable of demonstrating various artifacts, such as image distortion caused by metallic implants in MR imaging, is presented. The structure of the program allows for the implementation of various imaging situations as long as spins only experience weak interaction, i.e., the Bloch equations are obeyed. The raw data are obtained by repeatedly applying the Bloch equations to the magnetization vector of each point of the simulated object, throughout the pulse sequence. With only a limited number of spins in each voxel, the effects of intravoxel dephasing and rephasing require special attention, and algorithms for this have been implemented.

Algorithms↗

Deuterium MR spectroscopy at 4.7 T. Quantification of tumour and subcutaneous tissue blood flow in animal models.

Deuterium MR spectroscopy was used for the determination of tissue blood flow (TBF). The tracer D2O was injected into the tissue of interest, and tracer washout was followed using a 4.7 T spectroscopy/imaging unit. Normal subcutaneous tissue in rats was studied, as well as tissue influenced by vasoactive agents (papaverine and adrenaline). The vasoactive agents introduced changes of 40% in TBF, compared with normal tissue. Normal tissue measurements were repeated using various D2O injection volumes (5-400 microliters). The injection volume 5 microliters gave TBF 11.7 +/- 2.0 ml/100 g.min (mean +/- 1 SD). This value was 40% higher than corresponding values observed at larger injection volumes (200-400 microliters). This injection volume effect is probably partly due to a capillary dilution caused by tracer administration, and partly related to the non-physiological deuterium signal decrease observed in dead rats. Blood flow measurements in human colon tumours implanted in nude mice showed a rather poor reproducibility, not improved by the use of a multiple site injection technique.

Adipose Tissue↗

Use of an enhanced gradient system for diffusion MR imaging with motion-artifact reduction.

PURPOSE: A spin-echo diffusion-sensitized pulse sequence using high gradients (23 mT/m) is introduced. MATERIAL AND METHODS: In order to minimize motion artefacts, velocity-compensating gradients, ECG-triggering and post-processing with phase correction and raw data averaging using navigator echoes was performed. The in vitro ratio of diffusion coefficients for water and acetone was determined and the water self-diffusion coefficient at different temperatures was evaluated. The pulse sequence was tested in 7 healthy volunteers and in 2 tumour patients with astrocytomas of grades I-II and III-IV. Both single-slice and multi-slice techniques were used. RESULTS: The incorporation of phase correction clearly improved the quality of both diffusion-encoded images and the calculated diffusion maps. Mean values of the diffusion coefficients in vivo were for CSF 2.66 x 10(-9) m2/s and for white and grey matter 0.69 x 10(-9) m2/s and 0.87 x 10(-9) m2/s, respectively. CONCLUSION: Velocity-compensating gradients in combination with a high gradient strength were shown to be useful for in vivo diffusion MR imaging.

Adult↗

Pulsatile brain movement and associated hydrodynamics studied by magnetic resonance phase imaging. The Monro-Kellie doctrine revisited.

Brain tissue movements were studied in axial, sagittal and coronal planes in 15 healthy volunteers, using a gated spin echo MRI sequence. All movements had characteristics different from those of perfusion and diffusion. The highest velocities occurred during systole in the basal ganglia (maximum 1.0 mm/s) and brain stem (maximum 1.5 mm/s). The movements were directed caudally, medially and posteriorly in the basal ganglia, and caudally-anteriorly in the pons. Caudad and anterior motion increased towards the foramen magnum and towards the midline. The resultant movement occurred in a funnel-shaped fashion as if the brain were pulled by the spinal cord. This may be explained by venting of brain and cerebrospinal fluid (CSF) through the tentorial notch and foramen magnum. The intracranial volume is assumed to be always constant by the Monro-Kellie doctrine. The intracranial dynamics can be viewed as an interplay between the spatial requirements of four main components: arterial blood, capillary blood (brain volume), venous blood and CSF. These components could be characterized, and the expansion of the arteries and the brain differentiated, by applying the Monro-Kellie doctrine to every moment of the cardiac cycle. The arterial expansion causes a re-moulding of the brain that enables its piston-like action. The arterial expansion creates the prerequisites for the expansion of the brain by venting CSF to the spinal canal. The expansion of the brain is, in turn, responsible for compression of the ventricular system and hence for the intraventricular flow of CSF.

Adult↗

Theoretical and experimental evaluation of phase-dispersion effects caused by brain motion in diffusion and perfusion MR imaging.

We investigated intravoxel phase dispersion caused by pulsatile brain motion in diffusion spin-echo pulse sequences. Mathematical models were used to describe the spatial and temporal velocity distributions of human brain motion. The spatial distribution of brain-tissue velocity introduces a phase spread over one voxel, leading to signal loss. This signal loss was estimated theoretically, and effects on observed diffusion coefficient and perfused capillary fraction were assessed. When parameters from a diffusion pulse sequence without motion compensation were used, and ECG triggering with inappropriate delay times was assumed, the maximal signal loss caused by brain-motion-induced phase dispersion was predicted to be 21%. This corresponds to a 95% overestimation of the diffusion coefficient, and the perfusion-fraction error was small. Corresponding calculations for motion-compensated pulse sequences predicted a 1% to 1.5% signal loss due to undesired phase dispersion, whereas experimental results indicated a signal loss related to brain motion of 4%.

Adult↗

Regional cerebral blood flow distributions in normal volunteers: dynamic susceptibility contrast MRI compared with 99mTc-HMPAO SPECT.

PURPOSE: Relative regional cerebral blood flow (rCBF) at rest was measured in 44 volunteers using both dynamic susceptibility contrast (DSC) MRI and (99m)Tc-HMPAO SPECT on the same day. METHOD: In MRI, a Gd-DTPA-BMA contrast agent bolus (0.3 mmol/kg body wt) was monitored with a simultaneous dual FLASH pulse sequence (time resolution 1.5 s). MRI-based rCBF images were calculated by singular value decomposition-based deconvolution of the measured tissue concentration-time curve with an arterial input function from a small artery within the imaging slice. In the SPECT investigation, 900 MBq of (99m)Tc-HMPAO was injected intravenously. Relative rCBF in gray matter in the thalamus and in frontal white matter was determined. RESULTS: The ratio of relative rCBF in gray matter to relative rCBF in white matter was 2.21 +/- 0.57 using MRI and 2.24 +/- 0.54 using SPECT (mean +/- SD). CONCLUSION: Relative rCBF maps from DSC MRI and (99m)Tc-HMPAO SPECT showed good agreement, and the MRI-based rCBF ratio correlated with the corresponding SPECT-based ratio (r = 0.79, p < 0.0000006).

Adult↗