PubMed Health⌕ Search

Biomedical subjects

R Wyss

Publications and source records attributed to R Wyss.

At least 19 recordsLinked to original sources

Alignment delays in the N = Z nuclei (72)Kr, (76)Sr, and (80)Zr.

The ground state rotational bands of the N = Z nuclei (72)Kr, (76)Sr, and (80)Zr have been extended into the angular momentum region where rotation alignment of particles is normally expected. By measuring the moments of inertia of these bands we have observed a consistent increase in the rotational frequency required to start pair breaking, when compared to neighboring nuclei. (72)Kr shows the most marked effect. It has been widely suggested that these "delayed alignments" arise from np-pairing correlations. However, alignment frequencies are very sensitive to shape degrees of freedom and normal pairing, so the new experimental observations are still open to interpretation.

Journal Article↗

Microscopic structure of fundamental excitations in N = Z nuclei.

An extended mean-field model is presented that describes states of different isospin in odd-odd and even-even nuclei. Excitation energies of the T = 1 states in even-even as well as T = 0 and T = 1 states in odd-odd N = Z nuclei are calculated. It is shown that the structure of these states can be determined in a consistent manner when both isoscalar and isovector pairing collectivity as well as isospin projection (treated here within the isocranking approximation) are taken into account. In particular, in odd-odd N = Z nuclei, the interplay between quasiparticle excitations (relevant for the case of T = 0 states) and isorotations (relevant for the case of T = 1 states) explains the near degeneracy of these states.

Journal Article↗

Rotations in isospace: a doorway to the understanding of neutron-proton superfluidity in N = Z nuclei.

The T = 2 excitations in even-even N = Z nuclei are calculated within the isospin cranked mean-field approach. The response of pairing correlations to rotation in isospace is investigated. Whereas the isovector pairing rather modestly modifies the single-particle moment of inertia in isospace, the isoscalar pairing strongly reduces its value. This reduction of the isomoments of inertia with respect to its rigid body value is a strong indicator of collective isoscalar pairing correlations. These results are further generalized yielding beautiful analogies between the role of isovector pairing for the case of spatial rotations and the role of isoscalar pairing for the case of isorotations.

Journal Article↗

Determination of retinol and retinyl esters in human plasma by high-performance liquid chromatography with automated column switching and ultraviolet detection.

A HPLC method with automated column switching and UV detection is described for the simultaneous determination of retinol and major retinyl esters (retinyl palmitate, retinyl stearate, retinyl oleate and retinyl linoleate) in human plasma. Plasma (0.2 ml) was deproteinized by adding ethanol (1.5 ml) containing the internal standard retinyl propionate. Following centrifugation the supernatant was directly injected onto the pre-column packed with LiChrospher 100 RP-18 using 1.2% ammonium acetate-acetic acid-ethanol (80:1:20, v/v) as mobile phase. The elution strength of the ethanol containing sample solution was reduced by on-line supply of 1% ammonium acetate-acetic acid-ethanol (100:2:4, v/v). The retained retinol and retinyl esters were then transferred to the analytical column (Superspher 100 RP-18, endcapped) in the backflush mode and chromatographed under isocratic conditions using acetonitrile-methanol-ethanol-2-propanol (1:1:1:1, v/v) as mobile phase. Compounds of interest were detected at 325 nm. The method was linear in the range 2.5-2000 ng/ml with a limit of quantification for retinol and retinyl esters of 2.5 ng/ml. Mean recoveries from plasma were 93.4-96.5% for retinol (range 100-1000 ng/ml) and 92.7-96.0% for retinyl palmitate (range 5-1000 ng/ml). Inter-assay precision was < or =5.1% and < or =6.3% for retinol and retinyl palmitate, respectively. The method was successfully applied to more than 2000 human plasma samples from clinical studies. Endogenous levels of retinol and retinyl esters determined in female volunteers were in good accordance with published data.

Automation↗

[Malaria--chemoprophylaxis 2001].

An estimated 20,000 to 30,000 cases of imported malaria are annually diagnosed in industrialised countries. Some 700 of them concern Swiss travellers and foreign guests. Exposure prophylaxis and chemoprophylaxis for high risk destinations lower the risk of malarial disease. The latter is defined as regular intake of antimalarial drugs in subtherapeutic dosage in order to suppress the development of clinical disease. Drugs are usually taken from one week before travel until four weeks after return from an endemic area. Mefloquine, doxycycline, chloroquine plus proguanil, and presumably soon also atovaquone plus proguanil are available in Switzerland for chemoprophylaxis.

Africa↗

[Air travel--a disease risk? ].

Civil air traffic moves in an altitude that is dangerous for human beings without technical aids. Low temperature and humidity, reduced air pressure combined with oxygen pressure, seasonal depending high concentration of ozone and cosmic radiation may also be risk factors. Further risks on long haul flights may be jet lag, risk of economy class syndrome and contact with permethrin, because of disinsection before take-off out of tropical regions. The aim of an airline is to offer good cabin air quality, comfort and security for all passengers, may they be healthy, old, disabled or sick. Medical incidences on board arise and passengers expect modern equipment such as doctor's kit and defibrillators.

Aerospace Medicine↗

A triplet of differently shaped spin-zero states in the atomic nucleus 186Pb

Understanding the fundamental excitations of many-fermion systems is of significant current interest. In atomic nuclei with even numbers of neutrons and protons, the low-lying excitation spectrum is generally formed by nucleon pair breaking and nuclear vibrations or rotations. However, for certain numbers of protons and neutrons, a subtle rearrangement of only a few nucleons among the orbitals at the Fermi surface can result in a different elementary mode: a macroscopic shape change. The first experimental evidence for this phenomenon came from the observation of shape coexistence in 16O (ref. 4). Other unexpected examples came with the discovery of fission isomers and super-deformed nuclei. Here we find experimentally that the lowest three states in the energy spectrum of the neutron deficient nucleus 186Pb are spherical, oblate and prolate. The states are populated by the alpha-decay of a parent nucleus; to identify them, we combine knowledge of the particular features of this decay with sensitive measurement techniques (a highly efficient velocity filters with strong background reduction, and an extremely selective recoil-alpha-electron coincidence tagging methods). The existence of this apparently unique shape triplet is permitted only by the specific conditions that are met around this particular nucleus.

Journal Article↗

Determination of the N-methyl-D-aspartate receptor NR2B subunit blocker Ro 63-1908 in rat, cynomolgus monkey and human plasma by high-performance liquid chromatography with column switching and fluorescence detection.

A HPLC method with automated column switching was developed and validated for the determination of Ro 63-1908 in rat and cynomolgus monkey plasma. Human plasma was used for calibration and was also included in the validation process. Ro 63-1908 belongs to a class of neuroprotective N-methyl-D-aspartate (NMDA) receptor blockers which were in development for the treatment of stroke and traumatic brain injury. The method involves deproteinisation of plasma samples with ethanol and direct injection of the supernatant (1.4 ml) into the HPLC column-switching system. To prevent a breakthrough of the analyte and the internal standard on the precolumn (Purospher RP-18, 75x4 mm) due to the high ethanol content, the injection solution was diluted, on-line, using an additional pump and a T-piece. 1% ammonium acetate-ethanol (100:2, v/v) was used as mobile phase for injection, as well as for on-line dilution, resulting in pre-concentration of the analyte and the internal standard on the precolumn. As Purospher RP-18 is a non-endcapped stationary phase with a special selectivity for amines, the analyte and the internal standard could then be selectively eluted with 30% acetonitrile (without any buffer in the mobile phase) and transferred to the analytical column [consisting of two coupled columns (125+250x4 mm) packed with Superspher 60 RP-select B], where they were separated by gradient elution and detected by fluorescence detection. Compared to the use of a 125 mm long precolumn and dilution of the supernatant with ammonium acetate prior to injection, the 75 mm precolumn and the on-line dilution procedure allowed about one third shorter run times (21 min) and, therefore, a higher sample throughput. The limit of quantification was 1 ng/ml using 0.4 ml plasma. The method was applied to more than 670 plasma samples from pharmacokinetic and toxicokinetic studies and is also suitable for other matrices and NMDA receptor blockers.

Animals↗

[The occurrence of Toxoplasma gondii and Neospora caninum as regards meat hygiene].

Toxoplasma gondii and Neospora caninum are phenotypically and phylogenetically closely related cyst-forming coccidia, both of which may cause abortion in livestock animals. T. gondii exhibits also zoonotic potential by causing diaplacental infections in the human fetus and harmful infections in immunosuppressed individuals. Humans get infected either by consuming inappropriately prepared cyst-containing meat or by ingesting oocysts originating from cat feces. Therefore, in order to assess infection risk we need to have knowledge on the prevalence of the parasite in consumable meat and thus slaughtered animals. So far, no data indicate any zoonotic potential for N. caninum. Due to its high economic impact in the bovine production in Switzerland, we included this parasite in the present study as well. The prevalence of both parasite species were investigated by PCR in muscle and brain samples of slaughtered bovines, sheep, pigs and horses. Comparatively, a serum sample from each animal was simultaneously tested serologically by a Toxoplasma-P30-ELISA and a Neospora-SA-ELISA. The prevalences determined by the T. gondii-PCR were the followings: adult cows 3%, young bulls 2%, young cows prior to gravidity 6%, calves 1%, sheep 6%, horses and pigs each 0%. For N. caninum, the PCR-prevalence was 2% for adult cows and 0% for all other animal groups. Conversely, the seroprevalences were much higher for both parasite species and all animal groups, with the exception of the fattening pigs. However, as T. gondii was principally detectable in bovine (cows and calves) as well as in sheep meat, the consumption of this meat harbours a potential infection risk for humans. In contrast, the lack of any parasite detectability in fattening pig and horse meat allows to consider this infection source as neglectable when compared to bovine and ovine meat.

Animals↗

[Molecular and immunodiagnostic studies of bovine neosporosis in Switzerland].

Cyst-forming coccidia may cause significant losses in livestock, primarily due to abortion, loss of young animals and neuromuscular diseases. Rather recently, Neospora caninum has been recognized as one of the major protozoal abortion-inducing parasites in cattle. The present study addressed the performance of different diagnostic tools (in vitro-cultivation; histology; immunohistochemistry; serology; PCR) suitable for the direct or indirect detection of N. caninum. By PCR, Neospora-DNA was detected in 24 brains (29%) from 83 bovine abortion, many of these brains were simultaneously characterized by histopathological findings typical for a protozoal, cerebral parasitosis. The diagnostic methods were furthermore assessed using samples of different tissues and body fluids from three experimentally Neospora-infected pregnant cows and their foetuses. The diaplacental passage of N. caninum to the foetus was successful in two of the three cases. In these two cases, PCR was positive for different foetal organs and, additionally, for the abomasal and amniotic fluid. The successfully infected cows developed anti-Neospora serum antibodies between 10 and 17 days post infection, foetuses remained serologically negative in all cases. The results obtained in the present study demonstrated the usefulness of PCR, complemented by serology, for the specific diagnosis of bovine neosporosis. Such tests may prove suitable to perform epidemiological investigations. Taken together, our data indicated that prenatal neosporosis may be an important cause of infectious bovine abortion in Switzerland.

Abortion, Veterinary↗

Determination of several N-methyl-D-aspartate receptor blockers in plasma and brain by a selective high-performance liquid chromatographic method with column switching.

A general procedure is presented for the determination of several N-methyl-D-aspartate (NMDA) receptor open-channel and subtype-selective blockers, which have been evaluated and developed as neuroprotective drugs for the treatment of brain stroke and trauma. The method involves deproteination of plasma with ethanol, or homogenization of brain samples in ethanol, dilution of the supernatant with ammonium acetate and direct injection into an HPLC column-switching system. Although the investigated NMDA receptor blockers are all tertiary amines, they have quite different structures. However, they are all concentrated on the first column (Purospher RP-18, 125 x 4 mm), whereas polar interfering compounds are washed out with 1% ammonium acetate-acetic acid-acetonitrile (100:1:5, v/v/v). Due to the special selectivity of the Purospher RP-18 material, the analytes and the internal standard are then selectively eluted with 25% acetonitrile (without any buffer in the mobile phase) and transferred to the analytical column (Superspher 60 RP-select B, 250 x 4 mm), where they are separated by gradient elution and detected by UV or fluorescence detection. The low degree of interference allowed the development of sensitive methods with quantification limits of 5 ng/ml for animal plasma (0.4 ml used), 0.5 ng/ml for human plasma (1 ml used) and 50 ng/g for brain tissue (200 mg used).

Animals↗

Molecular and immunodiagnostic investigations on bovine neosporosis in Switzerland.

Neospora caninum has gained considerable attention through its role in the aetiology of bovine abortion. Due to its close phylogenetic relationship with Toxoplasma gondii, respective unequivocal differential diagnosis deserves special consideration. In order to evaluate the diagnostic performance of molecular and immunodiagnostic techniques and to provide insights into the epidemiological significance of bovine neosporosis in Switzerland, we conducted a study on 83 cases of bovine abortion: of these, 24 (29%) foetal brains were positive by Neospora-PCR, six of these foetuses were simultaneously seropositive in Neospora-IFAT and/or somatic antigen-ELISA. Conversely, four (5%) foetal brains were considered positive by Toxoplasma-PCR, two of which were also seropositive in the Toxoplasma-P30-ELISA and/or direct agglutination test. The seroprevalence in 1689 cattle sera obtained from 113 diary farms was 11.5% (95% confidence interval: 9.2-13.8) by Neospora-somatic antigen-ELISA were and 10.7% (95% confidence interval: 8.3-12.6) by Toxoplasma-P30-ELISA. From the same samples, 1.1%, less than statistically expected, were positive in both ELISA. Within selected groups of cow-calf farms, the seroprevalence determined using the Neospora-somatic antigen-ELISA was 14% (95% confidence interval 5.0-23.0) for dams and 15% (95% confidence interval: 3.0-28.0) for offspring calves. Seroprevalences determined by Toxoplasma-P30-ELISA were 8% (95% confidence interval: 4.0-12.0) for dams and 3% (95% confidence interval: 0.3-6.0) for calves. None of the sera gave a positive reaction in both ELISA. Our data indicated that prenatal neosporosis appears as an important cause of bovine abortion in Switzerland.

Abortion, Veterinary↗

Determination of 13-cis-3-hydroxyretinoic acid, all-trans-3-hydroxyretinoic acid and their 4-oxo metabolites in human and animal plasma by high-performance liquid chromatography with automated column switching and UV detection.

A high-performance liquid chromatographic method with automated column switching was developed for the simultaneous determination of 13-cis-3-hydroxyretinoic acid, all-trans-3-hydroxyretinoic acid and their metabolites 13-cis-3-hydroxy-4-oxo-retinoic acid and all-trans-3-hydroxy-4-oxo-retinoic acid in plasma samples from man, rat, dog, rabbit and mouse. The method consists of deproteination of plasma (0.4 ml) with ethanol (1.5 ml), containing the internal standard Ro 12-7310. After centrifugation, 1.4 ml of the supernatant was directly injected onto the precolumn (PC) (4 x 4 mm) packed with LiChrospher 100 RP-18 (5 microm). Ammonium acetate (0.02%)-acetic acid-ethanol (100:3:4, v/v/v) was used as mobile phase M1A during injection, as well as to decrease the elution strength of the injection solution by on-line addition using a T-piece (M1B). After valve switching, the retained components were transferred to the analytical column (AC), separated by gradient elution and detected at 360 nm. Two coupled Purospher 100 RP-18 endcapped columns (both 250 x 4 mm) were used for the separation, together with a mobile phase consisting of acetonitrile-water-10% ammonium acetate-acetic acid, (A), 540:450:2:30 (v/v/v/v), (B), 600:350:2:30 (v/v/v/v), and (C), 950:40:2:30 (v/v/v/v). The method was linear in the range 1-500 ng ml(-1), at least, with a quantification limit of 1 ng ml(-1). The mean recoveries from human plasma were 100-107% and the mean inter-assay precision was 2.0-4.7% (range 1-500 ng ml(-1)). Similar results were obtained for animal plasma. The analytes were stable in the plasma of all investigated species stored at -20 degrees C for 3 months, at least. The method was successfully applied to clinical and toxicokinetic studies.

Animals↗

Determination of endogenous levels of 13-cis-retinoic acid (isotretinoin), all-trans-retinoic acid (tretinoin) and their 4-oxo metabolites in human and animal plasma by high-performance liquid chromatography with automated column switching and ultraviolet detection.

A highly sensitive HPLC method with automated column switching was developed for the simultaneous determination of endogenous levels of 13-cis-retinoic acid (isotretinoin), all-trans-retinoic acid (tretinoin) and their 4-oxo metabolites in plasma samples from man, Cynomolgus monkey, rabbit, rat and mouse. Plasma (0.4 ml) was deproteinated by adding ethanol (1.5 ml) containing the internal standard acitretin. After centrifugation, 1.4 ml of the supernatant were directly injected onto the precolumn packed with LiChrospher 100 RP-18 (5 microm). 1.25% ammonium acetate and acetic acid-ethanol (8:2, v/v) was used as mobile phase during injection and 1% ammonium acetate and 2% acetic acid-ethanol (102:4, v/v) was added, on-line, to decrease the elution strength of the injection solution. After backflush purging of the precolumn, the retained components were transferred to the analytical column in the backflush mode, separated by gradient elution and detected at 360 nm. Two coupled Superspher 100 RP-18 endcapped columns (both 250x4 mm) were used for the separation, together with a mobile phase consisting of acetonitrile-water-10% ammonium acetate-acetic acid: (A) 600:300:60:10 (v/v/v/v), (B) 950:20:5:20 (v/v/v/v), and (C) 990:5:0:5 (v/v/v/v). The method was linear in the range 0.3-100 ng/ml, at least, with a quantification limit of 0.3 ng/ml. The mean recoveries from human plasma were 93.2%-94.4% and the mean inter-assay precision was 2.8%-3.2% (range 0.3-100 ng/ml). Similar results were obtained for animal plasma. The analytes were found to be stable in the plasma of all investigated species stored at -20 degrees C for 4.3 months and at -80 degrees C for 9 months, at least. At this temperature, human plasma samples were even stable for 2 years. The method was successfully applied to more than 6000 human and 1000 animal plasma samples from clinical and toxicokinetic studies. Endogenous levels determined in control patients and pregnant women were similar to published data from volunteers.

Adolescent↗

Negligible systemic absorption of topical isotretinoin cream: implications for teratogenicity.

The objective of the study was to assess the extent of systemic exposure of retinoic acid metabolites after excessive application of 0.1% isotretinoin cream in patients with photodamaged skin. This was a single-center, open-label, noncomparative, multiple-dose study of isotretinoin cream. Eighteen female patients with photodamaged skin received a 10 g topical application of isotretinoin cream once daily to a surface area of approximately 2,300 cm2 for 42 days. The patients were not allowed to have high vitamin A-containing foods, vitamin A supplements, or concomitant medications during the entire study period. Plasma levels of four retinoic acids (isotretinoin, tretinoin, 4-oxo-isotretinoin, and 4-oxo-tretinoin) were evaluated after 42 days of isotretinoin application and compared with baseline (pretreatment) levels. The mean area under the curve (AUC) in plasma increased by 48% (+/-SE 9.2) and 77% (+/-13) from the 24-hour pretreatment baseline level for isotretinoin and 4-oxo-isotretinoin, respectively, after treatment with excessive amounts of isotretinoin cream, suggesting systemic absorption of isotretinoin cream. This increase in systemic exposure of retinoic acids was less than that reported earlier after the U.S. recommended daily allowance of 5,000 i.u. of vitamin A supplementation (isotretinoin 141 +/- 19% and 4-oxo-isotretinoin 171 +/- 27%). The minimal systemic availability of isotretinoin cream compared with the U.S. recommended daily allowance for vitamin A supplements provides reasonable evidence for lack of its potential teratogenic risk.

Administration, Cutaneous↗

Determination of the arotinoid mofarotene in human, rat and dog plasma by high-performance liquid chromatography with automated column switching and ultraviolet detection.

A sensitive and specific high-performance liquid chromatographic method was developed and validated for the determination of the third-generation retinoid (arotinoid) mofarotene (Ro 40-8757) in human, rat and dog plasma, using direct injection of deproteinated plasma samples, automated column switching (on-line solid-phase extraction) and ultraviolet detection. Plasma (0.5 ml) was deproteinated by adding ethanol (1 ml) containing the internal standard Ro 42-8659 (200 ng/ml). After centrifugation, 0.9 ml of the supernatant were directly injected onto a precolumn packed with C18 Corasil 37-50 microns. Polar plasma components were washed out from the precolumn using 1% ammonium acetate-acetic acid-acetonitrile (900:9:100, v/v/v). After valve switching, the pre-concentrated compounds were transferred to the analytical column (C18) in the backflush mode, separated by gradient elution and detected at 300 nm. The retention times (total run times) were approximately 15 and 20 min for the internal standard and mofarotene, respectively. The method was linear in the range 10-1000 ng/ml with a limit of quantification of 10 ng/ml. The mean recoveries were 80.4%, 81.7% and 77.8% (range 10-1000 ng/ml) and the inter-assay precision was 2.7% (range 20-1000 ng/ml), 1.5% and 2.0% (both range 100-1000 ng/ml) for human, rat and dog plasma, respectively. Mofarotene was found to be stable in human, rat and dog plasma stored at -20 degrees C for 3 months and 22 degrees C for 24 h. The method was successfully applied to clinical, pharmacokinetic and toxicokinetic studies.

Animals↗