PubMed Health⌕ Search

Biomedical subjects

R Yankelevich

Publications and source records attributed to R Yankelevich.

3 recordsLinked to original sources

Cesium-137 source strength verification.

Over the years, the protocol for Cesium-137 source calibration has undergone a number of revisions based on updated data. The 3M Corporation issued product alerts and a revision of the calibration protocol in the early 1980s. We verified the activity of clinically used cesium tubes and found the difference with the activity stated by 3M in the range of 6-13%, which exceeds the recommended by 3M adjustment of 5% for all sources issued before 1979. Therefore, the verification and adjustment of activity should be recommended for each affected tube individually.

Cesium Radioisotopes↗

Comparison of the transit dose components and source kinematics of three high dose rate afterloading systems.

High dose rate (HDR) afterloading systems are using a high activity Ir-192 source that stops at programmed dwell positions to deliver a prescribed dose. The treatment planning systems are based on the dose calculation model that does not take into account the transit part of a dose resulting from a source while in motion. In this presentation the transit dose components as well as the source kinematics of three commercially available HDR systems were examined using a previously established technique1 based on film dosimetry. The studied systems were: Nucletron-Oldelft, Omnitron 2000 and Gamma Med 12i. The optical density profiles permitted the observation and evaluation of such source kinematics features as velocity, acceleration, deceleration and the source movement between programmed dwell positions. The comparison of the transit dose components for all three HDR systems showed that the largest transit dose can be expected for the Omnitron system with the slowest speed source and the smallest transit dose component is on the Nucletron-Oldelft system with the fastest moving source.

Brachytherapy↗

Scattered radiation from linear accelerator and cobalt-60 collimator jaws.

PURPOSE: Solid state diodes and/or thermoluminescent dosimeters (TLDs) are often used to measure scattered radiation doses to critical organs immediately adjacent to radiation field sites. The energy-dependent response of these commonly used in vivo dosimeters sometimes makes the interpretation of measured values uncertain. This study investigates scattered radiation arising from the collimator jaws of linear accelerators and the treatment head of a cobalt-60 teletherapy unit. METHODS AND MATERIALS: A thin window Markus-type parallel-plate ionization chamber placed in a polystyrene phantom was employed to document the magnitude, energy composition, and sources of scattered radiation at surfaces near radiation fields. Measurements were taken both with and without additional phantom material covering the ionization chamber, as well as with various distances between the ionization chamber and edges of the radiation fields tested. RESULTS: Data was collected, analyzed and compared for treatment units produced by different manufacturers. It was found that the magnitude of scattered radiation to surfaces immediately adjacent to radiation fields ranged from 1% to 15% of the maximum dose along the beam central axis. These values showed a strong dependence upon distance from the edge of the radiation field, beam energy, collimator setting (field size), and the presence of externally mounted accessories. Teletherapy unit differences due to manufacturing firm origins were found to only slightly affect scattered radiation magnitude, while the orientation of upper and lower collimator jaws had absolutely no effect. CONCLUSIONS: Percent depth dose curves of scattered radiation were obtained and analyzed. The shapes of these depth dose curves suggest the presence of complex energy spectra from secondary electrons and scattered x-rays. Because of the presence of these complex energy spectra in areas immediately adjacent to radiation fields, caution should be observed when interpreting patient doses near radiation fields, if dose values have been measured in vivo using thermoluminescent dosimeters (TLDs) or solid state diodes. Many of these on-patient dosimetry devices are strongly energy dependent and may demonstrate large over- or under-responses in areas dominated by scattered radiation. The results of this study, thus, suggest that ionization chambers are preferred for determination of scattered radiation doses in such regions.

Humans↗