PubMed Health⌕ Search

Biomedical subjects

R Zeisler

Publications and source records attributed to R Zeisler.

21 records · Page 2Linked to original sources

Application of polyacrylamide gel electrophoresis/neutron activation analysis for protein quantification.

A combination of two methods, polyacrylamide gel electrophoresis (PAGE) and neutron activation analysis (NAA), has been applied to solutions containing phosphoproteins for the purpose of protein quantification. The proteins were separated by molecular weight using PAGE, and then the whole gel was activated by neutron bombardment. Densitometric measurements of the developed bands from 32P, taken from autoradiographs of the activated gels, resulted in quantification of the phosphorus, and then the related protein. This PAGE/NAA method was applied to several phosphoprotein-containing materials, including commercial milk products and reference materials, i.e., IAEA A-11, milk powder, and SRM 1845, Cholesterol in Egg Powder.

Caseins↗

Alaskan marine mammal tissue archival project.

A project to establish an archive of Alaskan marine mammal tissues was conceived in 1987 to be a part of the National Biomonitoring Specimen Bank (NBSB). Protocols and field collection of marine mammals, long-term storage, and analysis are summarized in this paper. Instrumental neutron activation analysis has been used for an initial evaluation of trace element content in samples of northern fur seal (Callorhinus ursinus) from the Pribilof Islands. The findings agree with previously observed trace element levels in northern fur seals. The archived specimens can be used in future studies when comparison of past and present pollution levels are needed.

Alaska↗

Instrumental neutron activation analysis of Standard Reference Material 1941, Organics in Marine Sediment. Element content and homogeneity.

The National Institute of Standards and Technology has developed a new Standard Reference Material 1941, "Organics in Marine Sediment." In addition to the organic constituents, over 30 elements have been determined by instrumental neutron activation analysis and prompt-gamma activation analysis. The homogeneity of the material was investigated and relative standard deviations of single-element concentrations in 250-mg samples were found to be 1% or less with regard to major inorganic constituents and rare earth elements. A slightly higher relative SD was found for elements that may stem from biological or anthropogenic input. The element concentrations determined in this work are discussed in comparison to concentrations in other similar reference materials. Concentrations for 31 elements will be included for information on the certificate.

Environmental Monitoring↗