PubMed Health⌕ Search

Biomedical subjects

R van Noort

Publications and source records attributed to R van Noort.

At least 19 recordsLinked to original sources

Scale of protection and the various types of sports mouthguard.

OBJECTIVES: To present a grading system of the protection offered by various types of mouthguard, together with an indication of associated risks, in order to make athletes aware of the consequences of improper or no mouth protection. METHODS: A review of the literature on mouthguards, mouthguard materials, and novel laminates for mouthguards was carried out as it was apparent that information on mouthguards was lacking. Studies on stock (or unfitted) mouthguards, mouth formed (boil and bite) mouthguards, and custom mouthguards are reviewed. RESULTS: A scale of protection offered by various mouthguards and novel laminates has been produced, where 0 indicates no mouthguard and 10 indicates a custom made mouthguard offering excellent protection. CONCLUSIONS: From work carried out on laminates and the manufacturing processes of mouthguards, it became apparent that information was lacking to enable athletes make informed decisions about the best oral protection for their chosen sport.

Athletic Injuries↗

The national survey of adverse reactions to dental materials in the UK: a preliminary study by the UK Adverse Reactions Reporting Project.

OBJECTIVE: Dental treatment involves the use of a wide range of materials. Many of the dental materials or their components pose a potential risk to the patient and member of the dental team. Pre-market biocompatibility testing cannot guarantee absolute safety, making monitoring of materials likely to cause an adverse reaction essential. The prevalence of adverse reactions to dental materials amongst dental patients and staff has not been systematically monitored in the UK. This project aims to develop a systematic approach to the evaluation and monitoring of the extent and severity of adverse reactions to dental materials in the UK. METHOD: Through the distribution of reporting forms to dental surgeries and laboratories in the UK, the ARRP has received 1,075 complete reports relating to adverse reactions seen or experienced by dental staff and patients. RESULTS: The main findings were that different materials cause adverse reactions to different groups of people. The largest proportion of patient related adverse reactions were reported to be due to metals (n = 175). These were mainly amalgam associated oral lichenoid reactions (n = 124). Dental technicians reported acrylic resin as the causal factor of hand dermatitis in 61% (44 out of a total 72) of cases reported. Finally, dental surgery staff reported gloves as causing hand dermatitis in 75% of cases (398 out of a total 531). CONCLUSIONS: Different dental materials affect different person groups depending on their exposure to the material. Dental staff are most at risk from an adverse reaction to latex gloves, whereas most reported reactions for patients were due to metals. For dental technicians the biggest danger of an adverse reaction was from acrylic resins. There is a need to continue to raise the awareness among dental professionals of the existence of the Adverse Reactions Reporting Project so as to overcome problems of under-reporting.

Acrylic Resins↗

Adverse reactions to protective gloves used in the dental profession: experience of the UK Adverse Reaction Reporting Project.

The Adverse Reaction Reporting Project (ARRP) was set up to measure the extent and severity of adverse reactions to dental materials in the UK. Further analysis into the use of protective gloves has been carried out to establish the degree to which gloves are having a deleterious effect on the dental profession. In addition the survey aimed to establish the techniques used to manage adverse reactions and their effectiveness. In a 23-month period, 369 reports were received concerning adverse reactions to protective gloves used in dental practices. Reporters were contacted for further information, and a 92% response rate was achieved. The 330 reports analysed showed dentists to be the largest group to report adverse reactions, whilst dental technicians reported the fewest. The referral rate for staff and patients was similar with a third of adverse reactions being referred (n=110) to a specialist for diagnosis. A confirmed diagnosis was received in 65% of referred cases (n=72), but the symptoms reported suggested a larger degree of Type I reactions occurring than diagnosed. The use of non-powdered gloves appeared to be favoured over powdered gloves in 42% of glove changes, and nitrile gloves were used as an alternative to latex in 39% of changes. In conclusion, the results from this survey showed that wearing gloves in dental practices in the UK caused a range of adverse reactions. In 79% (n=330) of cases reported and analysed, these reactions were readily resolved or improved by self-medication, prescribed medication and/or changing to a different type of protective glove.

Dental Staff↗

The effect of investment material and ceramming regime on the surface roughness of two castable glass-ceramic materials.

OBJECTIVE: To assess the surface roughness (R(a)) of two castable glass-ceramic materials, cast using four different investment materials and employing different ceramming regimes. METHODS: Forty discs, each 12 mm diameter and 2 mm thick were produced from two castable glass-ceramic materials, one a glass ionomer derivative based on 1.5SiO(2)-1Al(2)O(3)-0.53P(2)O(5)-1CaO-0.67CaF(2) (LG112), the other a fluorcanasite material based on 0.60SiO(2)-0.05K(2)O-0.10Na(2)O-0.15CaO-0.10CaF(2) (SG3). The discs were made using four dental investments, two gypsum-bonded (Whip-Mix Cristobalite (WMC), Degussa California (DC)) and two phosphate-bonded (Fujivest Super (FS), Techceram Glass (TG)). A Ni-Cr metal/ceramic alloy (Wiron 99) was also used as a control. Each investment was used to produce 10 discs for each glass-ceramic material, five left in the as-cast, glass state, the other five cerammed. Ceramming was carried out either within the investment mold or after de-vesting from the investment mold. The discs had their surface roughness values measured using a stylus, surface contact measuring instrument. RESULTS: For the Ni-Cr alloy the phosphate-bonded investments produced discs significantly smoother than those produced by the two gypsum-bonded investments (p<0.05). The FS investment produced the smoothest discs (p<0.05), but there was no significant difference between the discs produced by the two gypsum-bonded investments (p>0.05). For the SG3 material no significant differences were seen between the as-cast glass and cerammed discs (p>0.05), with the WMC investment producing the smoothest discs (p<0.05), and the TG investment the roughest (p<0.05). The LG112 material showed a significant difference between glass and cerammed discs for the gypsum-bonded investments (p<0.05) but not when using phosphate-bonded investments (p>0.05). With LG112 the WMC investment produced smoother discs than the DC and TG investments (p<0.05). The DC investment produced rougher discs than the two phosphate-bonded investments (p<0.05). SIGNIFICANCE: The selection of investment material can have a significant effect on the as-cast surface finish of castable glass-ceramic materials. A gypsum-bonded investment material gave smoother surface finishes compared to phosphate-bonded investments. The ceramming process significantly increases surface roughness.

Analysis of Variance↗

In vivo bone tissue response to a canasite glass-ceramic.

The aim of this study was to determine the biocompatibility and osteoconductive potential of a high-strength canasite glass ceramic. Glass-ceramic rods were produced using the lost-wax casting technique and implanted in the mid-shafts rabbit femurs. Implants were harvested at 4, 13 and 22 weeks and prepared for light and electron microscopy. Hydroxyapatite was used as a control material. Hydroxyapatite implants were surrounded by new mineralised bone tissue after 4 weeks of implantation. The amount of bone surrounding the implant increased slightly at 13 weeks. In contrast, canasite glass and glass ceramic implants were almost entirely surrounded by soft tissue during all the time periods. Close contact between bone and canasite glass-ceramic implant without the intervening fibrous tissue was observed in only a few regions. The canasite formulation evaluated was not osteoconductive and appeared to degrade in the biological environment. It was therefore concluded that the canasite formulation used was unsuitable for use as implant. Further work is required to improve the biocompatibility of these materials with bone tissue. It is possible that this could be achieved by reducing the solubility of the glass and glass ceramic.

Animals↗

XPS analysis of the surface of leucite-reinforced feldspathic ceramics.

OBJECTIVE: The bond of a silane-coupling agent to a ceramic surface is expected to be influenced by the composition and chemical state of the ceramic surface. The purpose of this study was to determine the variation in the composition and the chemical states of the surfaces of a range of leucite-reinforced feldspathic (LRF) ceramics using X-ray photoelectron spectroscopy (XPS). METHODS: Five LRF ceramic discs (IPS Empress,Optec HSP,VMK 68, Mirage, and a modified Mirage) were produced and polished to a 1 microm finish. A further nine discs of the modified Mirage were produced. The discs were stored for 48h in a vacuum oven at 110 degrees C to remove absorbed water. The surfaces of these discs were analysed by XPS. Survey scans at 30 degrees take-off angle were taken and surface composition (in at%) was calculated from the narrow scans for Si 2p, O 1s, Al 2p, Mg 2s, K 2p, Na 1s, Ca 2p and N 1s. RESULTS: Atomic concentration of elements (after exclusion of C) for the five LRF ceramics were in the range: O, 45.0-51.6%; Si, 26.7-35.6%; Al, 6.3-9.7%; Mg, 4.9-8.8%; K, 0.5-2.2%; N, 0.9-2.9% and less than 1% of Na and Ca. The shapes of the O 1s and Si 2p narrow scan core lines of the five LRF ceramics were virtually identical. SIGNIFICANCE: All five LRF ceramics were found to have a silica-rich surface layer due to a reduction in K and Na relative to the bulk composition. Both the composition and chemical states of the surfaces for the five LRF ceramics were very similar.

Aluminum Silicates↗

Effect of furnace type and ceramming heat treatment conditions on the biaxial flexural strength of a canasite glass-ceramic.

OBJECTIVE: To assess the effect of different heat treatment conditions when using two different furnace types on the biaxial flexural strength (BFS) of a fluorcanasite castable glass-ceramic. METHODS: Two furnace types, one a programmable furnace (PF), the other a dental laboratory burnout furnace (DLF), were used with various ceramming times to determine their effect on the BFS of a fluorcanasite castable glass-ceramic. The glass-ceramic material was cast to produce discs of 12 mm diameter and 2 mm thickness using the lost wax casting process (n = 80). After casting, both furnace types were used to ceram the discs. Half the discs were not de-vested from the casting ring before ceramming but cerammed in situ (DLF) and half were de-vested before ceramming (PF). All the discs were given a nucleation heat treatment at 520 degrees C for 1 h and then cerammed at 860 degrees C using four heat soak times (0.5, 1, 2 and 3 h). The DLF furnace had a rate of climb of 13 degrees C/min and the PF furnace had a rate of climb of 5 degrees C/min to 520 degrees C and 3 degrees C/min to 860 degrees C. After ceramming the discs were de-vested and the BFS determined using a Lloyd 2000R tester. RESULTS: The maximum BFS values seen for both furnace types were almost identical (280 MPa), but were achieved at different heat soak times (1 h DLF, and 2 h PF). The only significant differences in BFS values for the two furnaces were between the 0.5 and 2 h heat soak times (p < or = 0.05). Individual differences were seen between results obtained from each furnace type/heat soak times evaluated (p < or = 0.05). SIGNIFICANCE: Already available dental laboratory burnout furnaces can be used to ceram fluorcanasite glass-ceramic castings to the same BFS values as more expensive and slower specialist programmable furnaces.

Analysis of Variance↗

Dental materials: 1997 literature review.

This review of the published literature on dental materials for the year 1997 has been compiled by the Dental Materials Panel of UK. It continues a series of annual reviews started in 1973. Emphasis has been placed upon publications, which report upon the materials science or clinical performance of the materials. The review has been divided by accepted materials classifications (fissure sealants, glass polyalkenoate cements, dentine bonding, dental amalgam, endodontic materials, casting alloys, ceramometallic restorations and resin-bonded bridges, ceramics, denture base resins and soft lining materials, impression materials, dental implant materials, orthodontic materials, biomechanics and image processing, resin composites, and casting investment materials and waxes). Three hundred and thirty three articles have been reviewed.

Dental Materials↗

Bonding procedures for intraoral repair of exposed metal with resin composite.

PURPOSE: To determine if tin plating can be recommended for intraoral repair of ceramic veneered cast restorations where metal of unknown composition is exposed by loss of ceramic. This study investigated the effectiveness of surface treatments incorporating tin plating and unfilled resin to enhance the tensile bond strength of a resin composite restorative to three different metal ceramic casting alloys. MATERIALS AND METHODS: Gold-platinum, palladium-tin and nickel-chromium alloys were used to fabricate 120 rods of each alloy, 4 x 15 mm. The end of each rod was ground perpendicular on 600-grit SiC paper and grit blasted with 50-micron alumina. Rods from each alloy were divided into four groups of 30 to receive one of the following treatments before bonding pairs end to end with a visible light-polymerized resin composite (Herculite XRV): 1) direct bonding with the resin composite; 2) tin plating (Micro-Tin) and bonding; 3) application of unfilled resin (Chameleon) and bonding; 4) tin plated, application of unfilled resin and bonding. The bonded samples were stored in distilled water, incubated at 37 degrees C for 24 hours and tested for tensile bond strength at a crosshead speed of 1 mm/min in a Lloyd 1000R machine. The mode of failure was examined using a stereo zoom microscope. RESULTS: A statistically significant increase in tensile bond strength was demonstrated between the control (group 1) and both the gold and palladium alloy treated with tin plating and unfilled resin (group 4). Tin plating, or tin plating with the application of unfilled resin had no statistically significant effect on the tensile bond strength of resin composite to the nickel-chromium alloy. CONCLUSION: The results demonstrate that tin plating, in conjunction with the application of a low-viscosity unfilled resin, optimizes the tensile bond of a resin composite to the three alloys used in the study. This procedure can be recommended for intraoral repair of exposed metal when the type of alloy belongs to one of the investigated alloy groups.

Analysis of Variance↗

Do dentin bond strength tests serve a useful purpose?

PURPOSE: The publication of dentin bond strength data is prolific in the dental literature and will remain so as more and more new dentin bonding agents are marketed. It is the purpose of this presentation to assess the usefulness of this information. METHODS: The limitations of dentin bond strength tests are examined in the context of current knowledge about the methods used. RESULTS: The evidence provided shows that dentin bond strength measurement techniques provide data that is not able to act as a consistent predictor of clinical performance. Fundamental flaws in the most popular methods adopted have been identified and alternative approaches need to be explored. Unfortunately, we do not as yet have in place methodologies that allow us to establish a reliable link between laboratory bond strength data and clinical performance. CONCLUSION: For the present, clinically based evidence remains the only reliable means for the selection of dentin bonding agents.

Adhesiveness↗

Dental materials: 1996 literature review.

This critical review of the published literature on dental materials for the year 1996 has been compiled by the Dental Materials Panel of the UK. It continues the series of annual reviews started in 1973 and published in the Journal of Dentistry. Emphasis has been placed upon publications which report upon the materials science or clinical performance of the materials. The review has been divided by accepted materials classifications (fissure sealants, glass polyalkenoate cements, dentine bonding, dental amalgam, endodontic materials, casting alloys, resin-bonded bridges and ceramo-metallic restorations, ceramics, denture base resins and soft lining materials, impression materials, implants materials, orthodontic materials, biomechanics and image processing, resin composites and casting investment materials and waxes). Three hundred and thirteen articles have been reviewed.

Dental Alloys↗

Dental materials: 1996 literature review. Part 2.

This critical review of the published literature on dental materials for the year 1996 has been compiled by the Dental Materials Panel of the UK. It continues the series of annual reviews started in 1973 and published in the Journal of Dentistry. Emphasis has been placed upon publications which report upon the materials science or clinical performance of the materials. The review has been divided by accepted materials classifications (fissure sealants, glass polyalkenoate cements, dentine bonding, dental amalgam, endodontic materials, casting alloys, resin-bonded bridges and ceramo-metallic restorations, ceramics, denture base resins and soft lining materials, impression materials, implants materials, orthodontic materials, biomechanics and image processing, resin composites and casting investment materials and waxes). Three hundred and thirteen articles have been reviewed.

Ceramics↗

The effect of casting conditions on the biaxial flexural strength of glass-ceramic materials.

OBJECTIVE: To assess the effect of mould and glass casting temperatures on the biaxial flexural strength (BFS) of two different types of castable glass-ceramic, using existing laboratory equipment and techniques. METHODS: Two castable glass-ceramic materials were evaluated. One glass (LG3) is based on SiO2-Al2O3-P2O5-CaO-CaF2, and is similar in composition to glasses used in the manufacture of glass-ionomer cements. The other glass (SG3) is based on SiO2-K2O-Na2O-CaO-CaF2, and is a canasite-based material. Both materials were used to produce discs of 12 mm diameter and 2 mm thickness using the same lost-wax casting process as used for metal castings. Mould temperatures of between 500 degrees C and 1000 degrees C and glass casting temperatures of between 1100 degrees C and 1450 degrees C were evaluated. The cast discs were cerammed and the biaxial flexural strength determined with a Lloyd 2000 R tester. RESULTS: A significant difference was found for the BFS in the range of mould temperatures evaluated, with the optimum investment mould temperature being 590 degrees C for LG3 and 610 degrees C for SG3 (p = 0.0002 and p = 0.019, respectively). No significant differences were seen between any of the glass casting temperatures evaluated. SIGNIFICANCE: The mould temperature for castable glass-ceramic materials produced using the lost-wax casting process can have a significant effect on BFS. The optimum mould temperature may differ slightly depending on the type of material being used. The glass casting temperature of these materials does not appear to have a significant effect on BFS.

Analysis of Variance↗

Surface chemistry of a high-copper dental amalgam.

In amalgam, mercury is intended to take the form of stable intermetallic compounds. Any mercury leakage must therefore come from free mercury not involved in such compounds. Thus, a knowledge of the exact surface chemistry of dental amalgam is necessary if this phenomenon is to be understood. From XPS and EDS analyses, a model of the surface chemistry of amalgam is proposed which fully characterizes all the phases that are present. The data show the surface to have a composition different from that of the bulk, being comprised of a hydrocarbon deposit and adsorbed water covering the intermetallic phase gamma2 (Sn(6-8)Hg), tin (iv) oxide, and mercury in a free state. After amalgamation, the amount of mercury at the surface decreases with time and eventually attains a constant concentration, where it is all involved in the gamma2 phase, leaving no free mercury. A model is proposed for the surface of amalgam and the changes in this model with time.

Copper↗

Ceramic surface preparations for resin bonding.

PURPOSE: To evaluate the effects of hydrofluoric acid (HF) and acidulated phosphate fluoride (APF) primers on differently prepared leucite-containing feldspar ceramic surfaces. MATERIALS AND METHODS: Discs of a leucite-containing feldspar ceramic were prepared following the manufacturer's instructions. Surfaces were either polished, grit blasted or prepared with a diamond bur and then subjected to a range of etching procedures using HF or APF. The surface topography was examined using scanning electron microscopy (SEM). Back-scattered imaging, EDS and X-ray diffraction (XRD) were used for microstructural and compositional analysis. RESULTS: The etching process with HF consisted of a preferential attack of the leucite phase relative to the glass but also removed all features of the previous surface preparation. In contrast, APF etching resulted in the formation of surface deposits, superimposed on the surface roughness created by the prior surface preparations. It was not possible to identify the deposits after APF etching using XRD.

Acid Etching, Dental↗

[4 unusual cases of malignant lymphoma in the dog and cat].

Malignant Lymphoma is a common tumour disease in dogs and cats. In the dog lymphoma's are predominantly multicentric, while in the cat lymphoma's are mainly found in the mediastinum and intestinal tract. This article describes four cases of lymphoma found in unusual locations. Chemotherapy is briefly discussed.

Animals↗

[Percutaneous placement of an esophagostomy tube in cats: first experience with a new technique].

A new technique for percutaneous placement of tube esophagostomy for enteral feeding in cats is described. The technique is characterized by its symplicity and rapid placement of the feeding tube. Its use is demonstrated in 8 cats in which nutritional support with enteral feeding was indicated. Placement of the tube was performed without complications. The feeding tube was tolerated well. Complications after placement were restricted to occasional vomiting after feeding (n = 2) and minor inflammation of the esophagostomy incission. Tubes could be removed after 7 to 16 (median 14) days. Two cats died as a result of the primary disease. This technique is a useful aid in the application of enteral feeding because of its simplicity and minimal complications.

Animals↗