Monitoring the formation of thermal lesions with heat-induced echo-strain imaging: a feasibility study.

We investigated the feasibility of using echo-strain images to visualize the extent of high-intensity ultrasound (US)-induced thermal lesions during their formation. Echo-strain, defined as the relative deformation of the backscattered ultrasonic signal, is due to tissue expansion and to changes in the speed of sound during heating. First, a theoretical framework was developed to predict the influence of these effects on the echo signal. Then, a simulation tool was developed to create simulated echo-strain images in thermal lesions. Finally, experimental echo-strain images were acquired in 10 porcine liver samples in vitro for various exposure durations and ultrasonic intensities (resulting in lesions that extended 3 to 8 mm deep from the surface). For this purpose, radiofrequency (RF) frames were acquired at 8 frames per s while heating. For each consecutive pair of RF frames, an echo-strain image was calculated using standard elastographic processing. The echo-strain images were cumulated and displayed. The experimental echo-strain images were compared with gross pathology. The (isoechoic) lesions were visible both in simulated and in experimental cumulated echo-strain images as apparent expansion areas (tensile echo-strain), whereas surrounding tissues exhibited apparent compression. The tensile echo-strain area underestimated the lesion in simulations, but was representative of the lesion in experiments. High correspondence was found between the lesion depth measured from experimental cumulative echo-strain images (y) and from gross pathology (x) (Pearson's correlation = 0.90, linear regression y = x-0.1 mm, residual error = 0 +/- 0.9 mm). We hypothesized that significant tissue expansion made the thermal lesions highly visible in the experimental echo-strain images. In two cases, the ultrasonic intensity was too low to induce a lesion, and the corresponding experimental echo-strain images showed no visible lesion. We conclude that cumulative echo-strain images have the potential to monitor the formation of high-intensity US-induced thermal lesions.

Algorithms↗

Visualisation of HIFU lesions using elastography of the human prostate in vivo: preliminary results.

An imaging system was developed for prostate elastography in vivo using a transrectal ultrasound (US) probe to guide high-intensity focused US (HIFU) therapy of prostate cancer. Uniform compression was applied using a balloon, while a sector image was acquired. Strain was calculated from the gradient of the displacements obtained from the ultrasonic signal using the cross-correlation technique. Elastograms were acquired on a total of 31 patients undergoing HIFU therapy for localised prostate cancer. For two patients, only part of the prostate was treated and posttherapy magnetic resonance imaging (MRI) confirmed the size and position of the HIFU lesions seen in the elastograms as low strain areas, with a strain contrast ratio between 1.6 and 3.2. The whole prostate was treated for the next 29 patients. After treatment, the whole prostate appeared to be stiff in the elastograms and a 40% to 60% (mean 50%) decrease in average strain was observed when compared to strains measured before HIFU application. Tumours identified by biopsies and sonograms could occasionally be seen in the preoperative elastograms. Decorrelation effects occurred mainly because of low sonographic signal-to-noise ratio (SNR) and of out-of-plane motion induced by respiration.

Adenocarcinoma↗

Ultrasonic elastography using sector scan imaging and a radial compression.

Elastography is an imaging technique based on strain estimation in soft tissues under quasi-static compression. The stress is usually created by a compression plate, and the target is imaged by an ultrasonic linear array. This configuration is used for breast elastography, and has been investigated both theoretically and experimentally. Phenomena such as strain decay with tissue depth and strain concentrations have been reported. However in some in vivo situations, like prostate or blood vessels imaging, this set-up cannot be used. We propose a device to acquire in vivo elastograms of the prostate. The compression is applied by inflating a balloon that covers a transrectal sector probe. The 1D algorithm used to calculate the radial strain fails if the center of the imaging probe does not correspond to the center of the compressor. Therefore, experimental elastograms are calculated with a 2D algorithm that accounts for tangential displacements of the tissue. In this article, in order to gain a better understanding of the image formation process, the use of ultrasonic sector scans to image the radial compression of a target is investigated. Elastograms of homogeneous phantoms are presented, and compared with simulated images. Both show a strain decay with tissue depth. Then experimental and simulated elastograms of a phantom that contains a hard inclusion are presented, showing that strain concentrations occur as well. A method to compensate for strain decay and therefore to increase the contrast of the strain elastograms is proposed. It is expected that such information will help to interpret and possibly improve the elastograms obtained via radial compression.

Algorithms↗