Doxorubicin in experimental and clinical heart failure.

Doxorubicin-induced heart failure is a rare but serious illness due to the well-known treatment difficulties. Prevention strategies have not demonstrated the expected success and unfortunately, this specific type of heart failure does not respond to the usual medical therapy as other kinds of heart failure. Therefore, surgical procedures may be necessary in some patients. Cardiac transplantation is performed in most cases but it requires the cure of the neoplastic disease. This usually requires a recurrence-free interval of several years which is associated with a high attrition rate in these patients due to their cardiac disease. Therefore, other conservative and surgical treatment concepts were developed during the last years. This review presents the most common procedures and discusses their efficacy as well as their clinical applicability.

Animals↗

Quantification of aortic valve calcification using multislice spiral computed tomography: comparison with atomic absorption spectroscopy.

OBJECTIVES: Multislice spiral computed tomography (MSCT) allows the in vivo detection of valvular calcification. The aim of this study was to validate the quantification of aortic valve calcification (AVC) by MSCT with in vitro measurements by atomic absorption spectroscopy. METHODS: In 18 patients with severe aortic stenosis, 16 detector row MSCT (SOMATOM Sensation 16, Siemens, Forchheim, Germany with scan parameters as follows: 420 milliseconds tube rotation time, 12 x 0.75 mm collimation, tube voltage 120 KV) was performed before aortic valve replacement. Images were reconstructed at 60% of the RR interval with an effective slice thickness of 3 mm and a reconstruction increment of 2 mm. AVC was assessed using Agatston AVC score, mass AVC score, and volumetric AVC score. After valve replacement, the calcium content of the excised human stenotic aortic valves was determined in vitro using atomic absorption spectroscopy. RESULTS: The mean Agatston AVC score was 3,842 +/- 1,790, the mean volumetric AVC score was 3,061 +/- 1,406, and mass AVC score was 888 +/- 492 as quantified by MSCT. Atomic absorption spectroscopy showed a mean true calcification mass (Ca5(PO4)3OH) of 19 +/- 8 mass%. There was a significant correlation between in vivo AVC scores determined by MSCT and in vitro mean true calcification mass (r = 0.74, P = 0.0004 for mass AVC score, r = 0.79, P = 0.0001 for volumetric AVC score and r = 0.80, P = 0.0001 for Agatston AVC score) determined by atomic absorption spectroscopy. Linear regression analysis showed a significant association between the degree of hydroxyapatite (given in mass%) in the aortic valve and the degree of AVC (R = 0.74, F = 19.6, P = 0.0004 for mass AVC score, R = 0.80, F = 29.3, P = 0.0001 for Agatston AVC score and R = 0.79, F = 27.3, P = 0.0001 for volumetric AVC score) assessed by MSCT. CONCLUSION: MSCT allows accurate in vivo quantification of aortic valve calcifications.

Aged↗

In vivo experimental testing of a microaxial blood pump for right ventricular support.

The incidence of isolated right ventricular (RV) failure is rare in postcardiotomy patients, but high in patients undergoing implantation of a left ventricular assist device or cardiac transplantation. Therefore, we have developed a new microaxial flow device and report on our first in vivo animal trials. Six healthy adult female sheep weighing 80-90 kg underwent implantation of the microaxial blood pump for partial unloading of the right ventricle. This pump is a miniaturized rotary blood pump with a diameter of only 6.4 mm and a weight of 11 g. The inner volume of the pump is limited to 12 mL, and the inner artificial blood contacting surface is 65 cm(2). The pump consists of a rotor driven by an incorporated brushless direct current motor, the housing of the rotor, the inflow cage, the outflow cannula, and the driveline. At the maximum speed of 32,500 rotations/min, a flow of 6 L/min can be delivered. The inflow and outflow conduit were anastomosed to the right atrium and the main pulmonary artery, respectively. Hemodynamic and echocardiographic data as well as blood samples were measured over the whole test period of 7 days. The hearts and lungs as well as the pump were explanted for a thorough examination at the end of the trial. Systemic arterial blood pressures remained unchanged during the entire test period. RV cardiac output was diminished significantly as demonstrated by the echocardiographic studies. The number of platelets decreased perioperatively, but recovered within the test period. The free hemoglobin was not enhanced postoperatively indicating no significant hemolysis. Liver function was only slightly impaired due to operative reasons (increase in bilirubin on the first postoperative day but normalization within the test period). The pathologic examination revealed some clots at the inflow cage and fibrin depositions on the impeller as well as on the inner surface of the outflow graft without an impairment of pump function. Our results demonstrate that this newly developed microaxial blood pump is a promising device for RV support, but it cannot be driven without any anticoagulation.

Animals↗

Treatment of right heart failure with a new microaxial blood pump.

Isolated postcardiotomy right ventricular failure is rare but associated with a high mortality. Therefore, new developments reducing this mortality are necessary. We report our first successful clinical use of a new paracardiac right ventricular microaxial blood pump which was developed for postcardiotomy right heart failure.

Cardiac Surgical Procedures↗

Normothermic beating heart surgery with assistance of miniaturized bypass systems: the effects on intraoperative hemodynamics and inflammatory response.

The use of miniaturized cardiopulmonary bypass (CPB) circuits and avoidance of cardioplegic arrest are attempts to reduce the inflammatory response to cardiac surgery. We studied the effects of beating heart surgery (BHS) with assistance of simplified bypass systems (SBS) on global hemodynamics, myocardial function and the inflammatory response to CPB. We hypothesized that the use of SBS was associated with less hemodynamic instability after CPB resulting from attenuation of the inflammatory response when compared with surgery performed with a conventional CPB (cCPB) circuit. Forty-five patients undergoing coronary artery bypass grafting were prospectively studied. Fifteen patients were randomized to the use of a cCPB circuit, cold crystalloid cardioplegia, and moderate hypothermia. Two groups of 15 patients underwent BHS during normothermia with assistance of two different SBS consisting of only blood pump and oxygenator. Hemodynamic variables were assessed with transpulmonary thermodilution and transesophageal echocardiography. Plasma levels of proinflammatory and antiinflammatory mediators were measured perioperatively. After CPB, variables of global hemodynamics and systolic ventricular function did not differ among groups. Left ventricular diastolic function was impaired after CPB equally in all groups (P < 0.01 versus pre-CPB). At the end of surgery, there was more need for vasopressor (norepinephrine) support in both SBS groups than in the cCPB group (P < 0.01). After CPB, the release of interleukin (IL)-6 did not differ significantly among groups, whereas plasma levels of IL-10 were higher in the cCPB group (P < 0.01 versus SBS). The extent of myocardial necrosis (Troponin T) was comparable in all groups. We conclude that in our study, miniaturizing bypass systems and avoidance of cardioplegic arrest were not effective in improving hemodynamic performance and in attenuating the proinflammatory immune response after CPB.

Anesthesia↗

Lower serum calcium levels are associated with greater calcium hydroxyapatite deposition in native aortic valves of male patients with severe calcific aortic stenosis.

BACKGROUND AND AIM OF THE STUDY: The study aim was to evaluate the relationship between serum calcium levels and the degree of calcification found in stenotic aortic valves. METHODS: Using atomic absorption spectroscopy, the hydroxyapatite content of 228 excised human stenotic aortic valves was determined and expressed as a percentage of valve mass. Left heart catheterization preceded valve replacement. In addition, serum levels of calcium and creatinine were determined before native calcific aortic valve excision. RESULTS: Valves from male patients contained more hydroxyapatite than those of female patients (26 +/- 9 versus 22 +/- 9 mass%; p < 0.001). Patients presenting with lower serum calcium levels showed a slight trend towards higher levels of valve calcification (r = -0.15, p = 0.026), but this association appeared only within the subgroup of male patients. Male patients with lowest serum calcium levels displayed greatest valvular hydroxyapatite deposition (1st calcium tertiary: 29.5 +/- 8.9 mass% versus 2nd calcium tertiary 26.4 +/- 7.8 mass% versus 3rd calcium tertiary 21.4 +/- 8.9 mass%; n = 122; p = 0.001; r = -0.25; p = 0.006). This association was even more distinct in male patients with normal serum creatinine levels. Furthermore, serum calcium was inversely and significantly associated with serum C-reactive protein in male patients (r = - 0.34; p < 0.001). CONCLUSION: Serum calcium levels appear to be inversely related to valve calcification in patients with severe calcific aortic stenosis (AS). This finding indicates the importance of systemic calcium metabolism in calcific AS, independent of manifest disorders of calcium metabolism or renal function. Interestingly, this association was evident only in male patients, suggesting a gender-dependent pathogenesis.

Aged↗

Hemodynamics of high-performance bileaflet valves: comparison to simulated clinical Doppler measurements.

BACKGROUND AND AIM OF THE STUDY: The newly designed, so-called 'high performance' bileaflet heart valve prostheses are suggested to be especially beneficial in small sizes. Herein, valvular energy loss and transvalvular gradients were evaluated using an in-vitro pulsatile flow model for aortic prostheses (St. Jude Medical Regent and On-X, sizes 19-23 mm). Gradients were compared with simulated clinically derived Doppler gradients to determine the extent of pressure recovery. METHODS: Valves were analyzed using a pulsatile circulatory mock loop simulator at heart rates of 70 and 110 bpm, and at cardiac outputs of 2, 4, 5, and 7 l/min, respectively (FDA requirements). Measurements consisted of computed calculation of energy loss and determination of mean pressure gradient by pressure transducers. A Doppler probe was mounted into the device for simultaneous measurement of Doppler gradient according to the Bernoulli equation. RESULTS: The systolic energy loss of the SJM Regent valve averaged 5.0 +/- 4.6% (range: 0.2 to 14.9%) of the effective forward energy, while that for the On-X valve was 6.5% (range: 0.7-22.8%). Total energy loss was 9.9% (range: 4.8-22.1%) for the SJM Regent valve, and 12.7% (range: 6.5-27.7%) for the On-X valve. The average extent of pressure recovery was 64% for both valve types. CONCLUSION: All tested valves were characterized by excellent hemodynamic performance, with overall low systolic and total energy losses, but results were slightly favorable for the SJM Regent valve. Valve performance was concluded to be much better than expected by clinical routine Doppler measurements, which significantly overestimates transvalvular gradients; this effect was explained by pressure recovery. Nevertheless, Doppler gradient remains a valuable follow up technique for patients with heart valve prostheses.

Biomechanical Phenomena↗

Aortic valve endocarditis with Bartonella quintana - a rare entity.

Endocarditis caused by Bartonella species is difficult to diagnose and still remains a rare entity. Therefore, a young male patient undergoing aortic valve replacement for culture-negative endocarditis is reported in whom the diagnosis of a Bartonella quintana infection was made with a great delay postoperatively.

Adult↗

Comparison of left ventricular lead placement via the coronary venous approach versus lateral thoracotomy in patients receiving cardiac resynchronization therapy.

Cardiac resynchronization therapy (CRT) is a new therapeutic option in patients with heart failure and ventricular conduction delay. We compared the long-term performance of left ventricular (LV) pacing via the coronary venous (CV) approach and a limited lateral thoracotomy (LLT). Data from 81 patients (age 65 +/- 12 years; 52 men, New York Heart Association class 3.0 +/- 0.4, ejection fraction 24 +/- 6%) were retrospectively analyzed for 1 year after implantation of a CRT system. Twenty-five patients received LLT leads and 56 patients received CV leads. Postoperative hospitalization was shorter after CV lead implantation (8 +/- 4 vs 12 +/- 5 days, p <0.01). No significant differences in LV pacing and sensing performance between both approaches were observed after 12 months. Reinterventions were necessary in 7 patients after CV implantation compared with only 1 reintervention (4%) in the LLT group (p = NS). Postoperative chest radiographs revealed an anterior lead position in 11 of 25 patients (44%) in the LLT group versus 3 of 56 patients (5.4%) in the CV group (p = 0.00007). Echocardiographic data demonstrated a significant increase in LV ejection fraction in the CV group (from 26.1 +/- 5.2% to 35.3 +/- 14.3% at 12 months, p <0.001, n = 42) in contrast to the LLT group (from 24.5 +/- 6.2% to 28.5 +/- 7.5% at 12 months, p = NS, n = 16) at 12-month follow-up. Cardiopulmonary exercise testing in 35 patients showed significantly more improvement in peak oxygen consumption after 12 months in the CV group (15.5 +/- 3.1 vs 13.6 +/- 2.6 ml/min/kg at implant, n = 22) compared with the LLT group (12.7 +/- 1.5 vs 11.8 ml/min/kg at implant, n = 13, p = 0.004). At 1-year follow-up the mortality rate was 24% (6 of 25) after LLT lead implantation versus 12.5% (7 of 56) after CV implantation (p = NS). Our data show that the LLT approach for LV lead placement in CRT systems has the advantage of a lower incidence of reinterventions. Hospitalization was longer, increase in functional capacity smaller, and mortality at 1-year follow-up higher, which were potentially related to a more anterior lead position. Therefore, CV leads are preferable to LLT leads.

Aged↗

The amount of calcium-deficient hexagonal hydroxyapatite in aortic valves is influenced by gender and associated with genetic polymorphisms in patients with severe calcific aortic stenosis.

AIMS: The study evaluated the relationship between cardiovascular risk factors (CRF), gene polymorphism, calcification and fibrosis of stenotic aortic valves. METHODS AND RESULTS: The calcium content of 187 excised stenotic aortic valves was determined using atomic absorption spectroscopy. Hydroxyproline content was quantified. Left-heart catheterization was performed. CRF and genotypes of the interleukin 10, connective tissue growth factor (CTGF) and chemokine receptor 5 (CCR5) polymorphisms were assessed. Calcification consisted of Ca-deficient hexagonal hydroxyapatite, Ca(10 - x)(HPO4)x(PO4)(6 - x)(OH)(2 - x); with 0<or=x<or=1. Calcification (quintiles) was positively associated with the mean gradient across the aortic valve (44 +/- 14, 52 +/- 17, 54 +/- 16, 60 +/- 15, 68 +/- 19 mm Hg; p<0.001). Males (n=101) had a higher degree of calcification (26.1 +/- 8.9 vs 20.8 +/- 9.2 mass%; p<0.001), despite the same mean gradient across the aortic valve (56 +/- 17 vs 56 +/- 19 mm Hg; p=0.958). CRF were not, whereas interleukin 10 polymorphisms -1082, -819, and -592 were significantly associated with the degree of calcification. Furthermore, if certain allele carriers had additionally the rare CCR5 or CTGF allele the degree of calcification was higher. CONCLUSION: Calcification of stenotic aortic valves consists of Ca-deficient hexagonal hydroxyapatite. Gender and genetic polymorphisms have an impact on the degree of aortic valve calcification.

Aged↗

[Surgical therapy of end-stage heart failure].

Heart failure is still associated with a poor prognosis despite great advances in drug therapy, so that surgical procedures are necessary in patients with end-stage cardiac failure. Cardiac transplantation was the therapy of choice during the last decades, but due to its disadvantages and the increasing scarcity of donor organs other surgical procedures were developed. Multisite pacing improves quality of life, but a longterm survival benefit remains to be proved. Coronary artery bypass grafting and valve surgery demonstrated to improve quality of life and to increase long-term survival. Ventricular assist devices are effective in bridging up to 70% of patients to cardiac transplantation, but the number of complications must be reduced. Partial left ventriculectomy may be performed with results similar to those obtained of cardiac transplantation, but long-term results are not yet available. Dynamic cardiomyoplasty and Myosplint implantation were not successful, but it must be awaited, if passive cardiomyoplasty leads to better results. Xenotransplantation is under intense investigation, but cannot be used clinically until now due to the hurdles of rejection and transfer of infectious diseases. This work provides a summary of today's knowledge about surgical procedures for end-stage heart failure.

Adult↗

A new right ventricular assist device for right ventricular support.

Right ventricular support by mechanical devices for postcardiotomy right heart failure is still associated with a high mortality. We report on the first use of a new paracardiac microaxial blood pump for postcardiotomy right heart failure in two patients undergoing emergency coronary artery bypass grafting (the first patient for a myocardial infarction complicated by a left ventricular wall rupture, the second patient for a dissection of the right coronary artery after an interventional procedure).

Coronary Artery Bypass↗

Specific linear left atrial lesions in atrial fibrillation: intraoperative radiofrequency ablation using minimally invasive surgical techniques.

OBJECTIVES: A specific left atrial (LA) linear lesion concept for treatment of paroxysmal and permanent atrial fibrillation (AF) was tested using intraoperative ablation with minimally invasive surgical techniques. BACKGROUND: Curative treatment for patients with chronic AF is among the main challenges of interventional electrophysiology. METHODS: Seventy patients (mean age 53 +/- 10 years) with drug-refractory persistent (n = 28) or paroxysmal (n = 42) AF underwent intraoperative radiofrequency (RF) ablation using video-assisted minimally invasive techniques via a right anterolateral minithoracotomy. Contiguous lesion lines involving the mitral annulus and the orifices of the pulmonary veins were placed with RF energy application under direct vision to prevent anatomically defined LA re-entrant circuits. RESULTS: Mean follow-up was 18 +/- 7 months in patients with permanent AF and 18 +/- 5 months in patients with paroxysmal AF. Antiarrhythmic drug treatment was instituted in patients with postoperative atrial arrhythmias to allow "reverse electrical remodeling" and was discontinued after three months. Six months following ablation, 93% of the patients were in sinus rhythm in both groups, and after 12 months, 95% and 97%, respectively. As major complications, one esophagus perforation and one circumflex coronary artery stenosis were observed. CONCLUSIONS: A pure linear lesion line concept confined to the left atrium targeting specifically at elimination of anatomically defined LA "anchor" re-entrant circuits eliminated AF in >90% of the patients treated with intraoperative ablation using minimally invasive surgical techniques over a mean follow-up of 1.5 years.

Aged↗

Curative treatment of atrial fibrillation with intraoperative radiofrequency ablation: short-term and midterm results.

OBJECTIVE: This report describes the early and midterm results after intraoperative radiofrequency ablation of atrial fibrillation for patients with isolated chronic atrial fibrillation or atrial fibrillation in combination with additional valvular and nonvalvular cardiac diseases. METHODS: From August 1998 to March 2001, a total of 234 patients with chronic atrial fibrillation underwent isolated intraoperative radiofrequency ablation alone (n = 74, 31.6%) or in combination with other cardiac procedures, such as mitral valve reconstruction (n = 57, 24.4%), mitral valve replacement (n = 38, 16.2%), aortic valve replacement (n = 11, 5.1%), coronary artery bypass grafting (n = 8, 5.0%), or a combination of the last with other cardiac procedures (n = 46, 19.7%). In all cases anatomic reentrant circuits confined within the left atrium were eliminated by placing contiguous lesion lines involving the mitral anulus and the orifices of the pulmonary veins through the use of radiofrequency energy application (exposure time, 20 seconds). A median sternotomy was used in 101 cases (43.2%), and video assistance through a right lateral minithoracotomy was used in 133 cases (56.8%). RESULTS: A total of 188 patients (83.9%) were discharged in sinus rhythm, 17 patients (7.6%) had atrial fibrillation, and 19 patients (8.5%) had atypical flutter. Pacemakers were implanted in 23 patients (9.8%). There were 10 in-hospital deaths (4.2%), and 30-day mortality was 5 patients (2.1%). In 3 cases (1.3%) an atrioesophageal fistula developed, necessitating surgical repair. Six months' follow-up was complete for 122 (61.0%) of 200 patients, with 99 patients still in stable sinus rhythm (81.1%, 95% confidence interval 73.1%-89.9%). Twelve months' follow-up was complete for 80 (90.9%) of 88 patients, with 58 patients still in sinus rhythm (72.5%, 95% confidence interval 61.3%-83.2%). CONCLUSIONS: Intraoperative radiofrequency ablation is a curative procedure for chronic atrial fibrillation. It is technically less challenging than the maze procedure and can be applied through a minimally invasive approach. Protection of the esophagus seems mandatory to avoid the deleterious complication of a left atrioesophageal fistula, such as was observed in 3 cases.

Adult↗

Experimental testing of a new left ventricular assist device--the microdiagonal blood pump.

All existing ventricular assist devices are associated with a considerable number of serious complications. This article reports on the first animal tests with a newly developed microdiagonal blood pump (MDP). Six adult female sheep weighing 80 to 90 kg underwent implantation of the microdiagonal blood pump. The inflow and outflow conduits were anastomosed to the left atrium and the descending aorta. Pump flow was adjusted to 2-3 L/minute. Hemodynamic and echocardiographic data, as well as blood samples, were measured over the entire test period of 7 days. All internal organs and the pump were explanted for thorough examination at the end of the trial. Mean arterial (range 88.5 +/- 13.1-103.7 +/- 10.7 mm Hg) and mean pulmonary arterial (18.3 +/- 2.7-21.6 +/- 20.5 mm Hg) pressures, as well as the pulmonary capillary wedge pressure (14.2 +/- 3.0 - 16.6 +/- 4.0 mm Hg), remained stable during the whole test period. Cardiac output (4.9 +/- 0.7 --> 3.2 +/- 0.5 L/minute) decreased postoperatively caused by partial unloading of the heart. Left ventricular end diastolic (4.1 +/- 0.5 --> 3.6 +/- 0.3 cm) and end systolic (3.2 +/- 0.4 --> 2.8 +/- 0.5 cm) diameters, as well as the ejection fraction (57 +/- 9 --> 42 +/- 5%), decreased after MDP implantation and did not change during the test period. Mean number of platelets (428 +/- 54 --> 286 +/- 66 x 10(3)/microL) and hemoglobin (9.8 +/- 1.3 --> 6.3 +/- 0.8 g/dL) decreased perioperatively because of surgical reasons and increased continuously in the postoperative course (platelet count and hemoglobin on day 7:441 +/- 74 x 10(3)/microL and 7.2 +/- 1.1 g/dL, respectively). Free hemoglobin was not enhanced in the postoperative course (mean value during the test period: 18.8 mmoL/L). Histologic examination of the organs did not demonstrate any infarctions of internal organs other than typical operative sequelae such as chronic pericarditis and some degree of atelectasis of the left lungs. These results demonstrate that the microdiagonal pump may be a promising alternative to the currently used ventricular assist devices, if long-term trials support these results.

Animals↗