PubMed Health⌕ Search

Biomedical subjects

Rabia Gürses-Ozden

Publications and source records attributed to Rabia Gürses-Ozden.

3 recordsLinked to original sources

Macular and retinal nerve fiber layer thickness measurement reproducibility using optical coherence tomography (OCT-3).

PURPOSE: To assess the reproducibility of retinal nerve fiber layer thickness and macular thickness measurements using OCT-3. METHODS: Randomly chosen eyes of healthy individuals were scanned following pupillary dilation by two trained operators (RGO, RV) using OCT-3 (software version A1.1, Carl Zeiss Meditec, Inc., Dublin, CA), three times on separate days within a one-month period. Fast and regular macula (128 A-scans), and fast and regular RNFL (256 A-scans) scanning protocols were performed. Intra- and interoperator measurement reproducibility was evaluated. RESULTS: Ten eyes of 10 subjects (6 females, 4 males) were enrolled. Mean age was 32 +/- 11.2 years (range, 21 to 52 years). Intraoperator reproducibility was high for both macular and RNFL thickness measurements. Mean coefficients of variation (CV) for mean total RNFL thickness measurements ranged from 6.9 +/- 6.4% to 8.0 +/- 3.5% for operators 1 and 2 in fast and regular RNFL protocols. Mean CV for mean macular thickness measurements ranged from 4.7 +/- 2.6% to 6.4 +/- 5.5% for operator 1 and 2 in fast and regular macula protocols. There was no difference in mean total RNFL and mean foveal thickness measurements performed on different days (P > 0.05 for all measurements in all protocols, for operators 1 and 2, ANOVA). Interoperator reproducibility was high for both macular and RNFL thickness measurements (P > 0.05 for all measurements in all protocols, paired t test). CONCLUSION: OCT-3 RNFL and macular thickness measurements are reproducible in normal eyes. These results should be validated in ocular hypertensive and glaucomatous eyes.

Adult↗

An improved technique of eye drop self-administration for patients with limited vision.

PURPOSE: To describe a new, highly accurate, tactile technique to increase accuracy in the self-administration of eye drops. DESIGN: Interventional case series. METHODS: Ten adult patients with loss of fixation (< or = 20/400) in one eye and ten adult patients with loss of fixation in both eyes instilled one drop of artificial tears in each eye using the technique normally employed at home. The time required to instill each drop, the number of drops squeezed from the bottle, and location of the drops' landing points on the face or eye were recorded. The patients were then instructed in a new technique for instillation, guided through the procedure once, and allowed to practice until comfortable with it. All measurements were then repeated. RESULTS: In patients with loss of fixation in one eye, an additional 3.2 +/- 4.1 seconds were required to instill a drop using the new technique (P <.0001, paired t test; range, -7-18 seconds). The mean number of drops dispensed decreased by 0.1 +/- 0.6 drops (P =.60, paired t test; range, -2-1 drop). The accuracy of drop placement increased from 80.0% to 82.5% (P =.32, paired t test). In subjects with loss of fixation in both eyes, using the new technique increased the time needed to instill a drop by 3.8 +/- 3.8 seconds (P <.0001, paired t test; range, -3-13 seconds). The average number of drops dispensed decreased by 0.1 +/- 0.6 drops (P =.25, paired t test; range, -2-1 drop). The accuracy of placement increased from 63.0% to 85.0% (P =.001, paired t test). CONCLUSIONS: This technique of drop instillation may be beneficial for patients with significant visual impairment in both eyes.

Adult↗

Acute conformational changes in the optic nerve head with rapid intraocular pressure elevation: implications for LASIK surgery.

BACKGROUND AND OBJECTIVE: To investigate the effects of acute intraocular pressure (IOP) elevation on optic disc morphology. PATIENTS AND METHODS: Ophthalmodynamometry was used to increase the IOP of normal, healthy eyes. Confocal scanning laser ophthalmoscopy of the optic nerve head using the Heidelberg Retinal Tomograph II (Heidelberg GmbH, Heidelberg, Germany) and IOP measurements were obtained before, during, and after IOP elevation. RESULTS: Sixteen eyes of 16 normal volunteers (mean age, 32.8 +/- 11.9 years) were enrolled. Rim area, rim volume, cup area, cup volume, cup-to-disc ratio, mean cup depth, maximum cup depth, mean retinal nerve fiber layer (RNFL) thickness, and RNFL cross-sectional area showed significant changes during IOP elevation (all P < .05, paired t test). All measured parameters returned to their original values after pressure resolution (all P > .2) except mean RNFL thickness (P = .03). CONCLUSION: Transient elevation of IOP results in measurable alterations in optic nerve head topography.

Adult↗