PubMed Health⌕ Search

Biomedical subjects

Rabih Hammoud

Publications and source records attributed to Rabih Hammoud.

4 recordsLinked to original sources

A quality assurance program for the on-board imagers.

To develop a quality assurance (QA) program for the On-Board Imager (OBI) system and to summarize the results of these QA tests over extended periods from multiple institutions. Both the radiographic and cone-beam computed tomography (CBCT) mode of operation have been evaluated. The QA programs from four institutions have been combined to generate a series of tests for evaluating the performance of the On-Board Imager. The combined QA program consists of three parts: (1) safety and functionality, (2) geometry, and (3) image quality. Safety and functionality tests evaluate the functionality of safety features and the clinical operation of the entire system during the tube warm-up. Geometry QA verifies the geometric accuracy and stability of the OBI/CBCT hardware/software. Image quality QA monitors spatial resolution and contrast sensitivity of the radiographic images. Image quality QA for CBCT includes tests for Hounsfield Unit (HU) linearity, HU uniformity, spatial linearity, and scan slice geometry, in addition. All safety and functionality tests passed on a daily basis. The average accuracy of the OBI isocenter was better than 1.5 mm with a range of variation of less than 1 mm over 8 months. The average accuracy of arm positions in the mechanical geometry QA was better than 1 mm, with a range of variation of less than 1 mm over 8 months. Measurements of other geometry QA tests showed stable results within tolerance throughout the test periods. Radiographic contrast sensitivity ranged between 2.2% and 3.2% and spatial resolution ranged between 1.25 and 1.6 lp/mm. Over four months the CBCT images showed stable spatial linearity, scan slice geometry, contrast resolution (1%; <7 mm disk) and spatial resolution (>6 lp/cm). The HU linearity was within +/-40 HU for all measurements. By combining test methods from multiple institutions, we have developed a comprehensive, yet practical, set of QA tests for the OBI system. Use of the tests over extended periods show that the OBI system has reliable mechanical accuracy and stable image quality. Nevertheless, the tests have been useful in detecting performance deficits in the OBI system that needed recalibration. It is important that all tests are performed on a regular basis.

Equipment Failure Analysis↗

MRI tissue characterization of experimental cerebral ischemia in rat.

PURPOSE: To extend the ISODATA image segmentation method to characterize tissue damage in stroke, by generating an MRI score for each tissue that corresponds to its histological damage. MATERIALS AND METHODS: After preprocessing and segmentation (using ISODATA clustering), the proposed method scores tissue regions between 1 and 100. Score 1 is assigned to normal brain matter (white or gray matter), and score 100 to cerebrospinal fluid (CSF). Lesion zones are assigned a score based on their relative levels of similarities to normal brain matter and CSF. To evaluate the method, 15 rats were imaged by a 7T MRI system at one of three time points (acute, subacute, chronic) after MCA occlusion. Then they were killed and their brains were sliced and prepared for histological studies. MRI of two or three slices of each rat brain (using two DWI (b = 400, b = 800), one PDWI, one T2WI, and one T1WI) was performed, and an MRI score between 1 and 100 was determined for each region. Segmented regions were mapped onto the histology images and scored on a scale of 1-10 by an experienced pathologist. The MRI scores were validated by comparison with histology scores. To this end, correlation coefficients between the two scores (MRI and histology) were determined. RESULTS: Experimental results showed excellent correlations between MRI and histology scores at different time points. Depending on the reference tissue (gray matter or white matter) used in the standardization, the correlation coefficients ranged from 0.73 (P < 0.0001) to 0.78 (P < 0.0001) using the entire dataset, including acute, subacute, and chronic time points. This suggests that the proposed multiparametric approach accurately identified and characterized ischemic tissue in a rat model of cerebral ischemia at different stages of stroke evolution. CONCLUSION: The proposed approach scores tissue regions and characterizes them using unsupervised clustering and multiparametric image analysis techniques. The method can be used for a variety of applications in the field of computer-aided diagnosis and treatment, including evaluation of response to treatment. For example, volume changes for different zones of the lesion over time (e.g., tissue recovery) can be evaluated.

Animals↗

Dosimetric characteristics of Novalis shaped beam surgery unit.

The dosimetric characteristics of a new dedicated radiosurgical treatment unit are systematically measured in terms of its percent depth dose, beam profile, and relative scatter factor. High-resolution diode detector, mini-ion-chamber detector, and conventional Kodak XV films are used to measure dosimetric data for a range of field sizes from 6x6 mm to 100x100 mm. The effects of collimator size, micro-multileaf collimator shape, and detector type on the dosimetric data are investigated. Results indicate that, with careful design, accurate dosimetric data could be acquired using either a dedicated diode detector or a mini-ion-chamber detector, and film detector. Special attention is required when measuring dosimetric data for small field sizes such as 6x6 mm.

Equipment Failure Analysis↗

Multiparametric MRI ISODATA ischemic lesion analysis: correlation with the clinical neurological deficit and single-parameter MRI techniques.

BACKGROUND AND PURPOSE: The purpose of this study was to show that the computer segmentation algorithm Iterative Self-Organizing Data Analysis Technique (ISODATA), which integrates multiple MRI parameters (diffusion-weighted imaging [DWI], T2-weighted imaging [T2WI], and T1-weighted imaging [T1WI]) into a single composite image, is capable of defining the ischemic lesion in a time-independent manner equally as well as the MRI techniques considered the best for each phase after stroke onset (ie, perfusion weighted imaging [PWI] and DWI for the acute phase and T2WI for the outcome phase). METHODS: We measured MRI parameters of PWI, DWI, T2WI, and T1WI from patients at the acute phase (<30 hours) and DWI, T2WI, and T1WI at the outcome phase (3 months) of ischemic stroke. The clinical neurological deficit was graded with the National Institutes of Health Stroke Scale (NIHSS). We compared the ISODATA lesion size with the PWI, DWI, and T2WI lesion sizes measured within the same slice at each phase. The lesion sizes were also correlated with NIHSS score of each phase. RESULTS: We included 11 patients; 9 (82%) were women, and 7 (64%) were black. The mean+/-SD age was 65.5+/-9.3 years (range, 45 to 82 years). The median NIHSS score was 15 (minimum, 4; maximum, 24)at the acute phase and 3 (minimum, 0; maximum, 22) at the outcome phase. The median time interval from stroke symptom onset to the acute MRI study was 10 hours (range, 6 to 29 hours), and the mean time interval to the outcome study was 93+/-11 days (range, 72 to 106 days). In the acute phase, the ISODATA lesion size had high correlation with the PWI lesion size (r=0.95; 95% CI, 0.89 to 0.98; P<0.0001), DWI lesion size (r=0.83; 95% CI, 0.66 to 0.92; P<0.0001), and T2WI lesion size (r=0.67; 95% CI, 0.39 to 0.84; P=0.008) and moderate correlation with NIHSS score (r=0.59; 95% CI, 0.02 to 0.88; P=0.06). In the outcome phase, the ISODATA lesion size had high correlation with the T2WI lesion size (r=0.97; 95% CI, 0.94 to 0.99; P<0.0001) and NIHSS score (r=0.78; 95% CI, 0.34 to 0.94; P=0.004). CONCLUSIONS: The integrated ISODATA method can identify and characterize the ischemic lesion independently of time elapsed since stroke onset. The ISODATA lesion size highly correlates with the PWI and DWI lesion size in the acute phase and with the T2WI lesion size in the outcome phase of ischemic stroke, as well as with the clinical neurological status of the patient.

Aged↗