PubMed Health⌕ Search

Biomedical subjects

Rachida Lebtahi

Publications and source records attributed to Rachida Lebtahi.

11 recordsLinked to original sources

Increased uptake of 111In-octreotide in idiopathic pulmonary fibrosis.

UNLABELLED: Idiopathic pulmonary fibrosis (IPF) is characterized by an uncontrolled accumulation and activation of lung fibroblasts. A modulation of fibroblast activation has been observed in various systems with octreotide, a synthetic somatostatin analog with strong affinity for the somatostatin receptor subtype 2 (sst2). One aim of our study was to evaluate the expression of somatostatin receptors in the lungs of patients with IPF. A second aim was to evaluate the relationship between 111In-octreotide uptake and the effect of pulmonary fibrosis as assessed by lung function tests and parameters and by radiologic findings. METHODS: We investigated 11 patients with IPF, 6 patients with pulmonary fibrosis associated with systemic sclerosis (SSc), and 19 patients with disease not of the lung (control patients). The expression of somatostatin receptors was evaluated in vivo using 111In-octreotide scintigraphy. We evaluated the relationship between 111In-octreotide uptake and the activity of pulmonary fibrosis as assessed by lung function tests, bronchoalveolar lavage (BAL) cellularity, and high-resolution CT (HRCT) of the chest. Planar images and thoracic SPECT (24 h) were performed after injection of 222 MBq of 111In-octreotide. Lung uptake was quantified using the lung-to-background ratio (L/B). In addition, the expression of sst2 was evaluated in vitro, in frozen lung-tissue samples using autoradiography, and in human cultures of lung fibroblasts using a ligand-binding assay. RESULTS: Compared with lung uptake in control patients (median L/B, 1.25; range, 1.14-1.49), lung uptake was increased in all 11 IPF patients (median L/B, 2.63; range, 1.59-3.13; P < 0.001) and in 4 of 6 SSc patients (median L/B, 1.68; range, 1.42-2.16). The L/B was lower in SSc patients than in IPF patients (P = 0.011). Increased uptake correlated with the alteration of lung function (carbon monoxide diffusing capacity [rho = -0.655; P = 0.038], diffusing capacity for carbon monoxide and alveolar volume ratio [rho = -0.627; P = 0.047], vital capacity [rho = -0.609; P = 0.054], and total lung capacity [rho = -0.598; P = 0.058]) and with the intensity of alveolitis (total BAL cellularity [rho = 0.756; P = 0.045], neutrophil counts [rho = 0.738; P = 0.05]), and HRCT fibrosis score (rho = 0.673; P = 0.007). Autoradiography suggested that vascular structures were a prominent binding site. Lung fibroblasts expressed somatostatin receptors in vitro as measured by binding assay. CONCLUSION: Our preliminary results identified an increased expression of sst2 in (mainly idiopathic) pulmonary fibrosis. Lung uptake correlates with the alteration of lung function and with the intensity of alveolitis.

Adult↗

Noninvasive evaluation of acute capillary permeability changes during high-volume ventilation in rats with and without hypercapnic acidosis.

OBJECTIVE: To evaluate whether hypercapnic acidosis attenuates acute alterations of pulmonary capillary permeability due to high lung stretch in rats using a simple, noninvasive, scintigraphic method. DESIGN: Prospective, randomized, controlled animal study. SETTING: University research laboratory. SUBJECTS: Male adult Wistar rats weighing 291 +/- 7.5 g. INTERVENTIONS: Three groups of rats were studied: controls ventilated with a low (6 mL/kg body weight) tidal volume and rats ventilated with a high (38 mL/kg body weight) tidal volume under normocapnic (Paco(2) = 35.2 +/- 1.65 mm Hg) or hypercapnic (Paco(2) = 102.5 +/- 5.63 mm Hg) conditions. MEASUREMENTS AND MAIN RESULTS: Pulmonary capillary permeability alterations were assessed by monitoring the rate of (111)In-transferrin accumulation in lung tissue. Respiratory system pressure-volume curves were registered and analyzed. High tidal volume ventilation increased In-transferrin plasma to lung flux in such a way that I(111)In-transferrin behaved like a marker of water. The rate of initial (first 30 mins of high tidal volume ventilation) lung transferrin accumulation measured by scintigraphy (standardized lung/heart ratio) was steady, correlated with the percent decrease in respiratory system compliance (a marker of edema progression), and did not differ between normocapnic and hypercapnic groups (18.9 +/- 3.97 vs. 14.2 +/- 2.89%/hr, not significant). However, lung In-tranferrin accumulation rate was highly scattered due to variable interindividual mechanical properties of the respiratory system. This rate was correlated with initial values of volume of the upper inflection point of the pressure-volume curve (r = -.53, p < .001) and end-inspiratory pressure (r = .54, p < .001). Mechanical properties were similar in normocapnic and hypercapnic rats. There was no difference between In-transferrin accumulation rates in these rats when a stringent selection was made based on end-inspiratory pressure (28-32 cm H(2)O) or body weight (330-360 g). CONCLUSIONS: Hypercapnic acidosis does not influence in vivo the acute increase in pulmonary capillary permeability due to high-volume ventilation.

Acidosis, Respiratory↗

The value of a completely automatic ECG gated blood pool SPECT processing method for the estimation of global systolic left ventricular function.

OBJECTIVES: Electrocardiographically gated blood pool SPECT (GBPS) is an interesting method for measuring left ventricular (LV) ejection fraction (LVEF) and volume. Recently, the availability of completely automatic GBPS processing software has been reported. We aimed to evaluate its reliability in measuring global LV systolic function. In addition, using the same population, we compared its reliability to that of three previously reported methods for processing GBPS. METHODS: We studied the performances of the new GBPS system for the evaluation of LVEFs and volumes in 29 patients. The LVEF provided by the planar equilibrium radionuclide angiography (planarLAO) and LV volumes provided by radiological LV contrast angiography (X-rays) were used as 'gold standards'. RESULTS: The new GBPS system failed in one patient. It shows good reproducibility for the measurement of both LVEF and volume. LVEF provided by this system is moderately correlated to planarLAO (r = 0.62; P < 0.001). The new GBPS constantly overestimates LVEF (P < 0.05). Results for LV volumes are moderately correlated to those obtained by X-ray investigation (r = 0.7; P < 0.001) but are significantly lower (P < 0.0001). There is a linear correlation between the average and the paired absolute difference for LV volumes (r = 0.52, P = 0.0001). CONCLUSIONS: The new, completely automatic, GBPS processing software is an interesting, moderately reliable method for measuring LVEF and volume. The performance of the method is lower than that previously reported for the same population for the other three GBPS processing methods.

Algorithms↗

Comparative value of ECG-gated blood pool SPET and ECG-gated myocardial perfusion SPET in the assessment of global systolic left ventricular function.

Both electrocardiographically (ECG) gated blood pool SPET (GBPS) and ECG-gated myocardial perfusion SPET (GSPET) are currently used for the measurement of global systolic left ventricular (LV) function. In this study, we aimed to compare the value of GSPET and GBPS for this purpose. The population included 65 patients who underwent rest thallium-201 GSPET imaging at 15 min after (201)Tl injection followed by planar (planar(RNA)) and GBPS equilibrium radionuclide angiography immediately after 4-h redistribution myocardial perfusion SPET imaging. Thirty-five patients also underwent LV conventional contrast angiography (X-rays). LV ejection fraction (EF) and LV volume [end-diastolic (EDV) and end-systolic (ESV) volumes] were calculated with GBPS and GSPET and compared with the gold standard methods (planar(RNA) LVEF and X-ray based calculation of LV volume). For both LVEF and LV volume, the inter-observer variability was lower with GBPS than with GSPET. GBPS LVEF was higher than planar(RNA) (P<0.01) and GSPET LVEF (P<0.01). Planar(RNA) LVEF showed a slightly better correlation with GBPS LVEF than with GSPET LVEF: r=0.87 and r=0.83 respectively. GSPET LV volume was lower than that obtained using X-rays and GBPS (P<0.01 for both). LV volume calculated using X-rays showed a slightly better correlation with GBPS LV volume than with GSPET LV volume: r=0.88 and r=0.83 respectively. On stepwise regression analysis, the accuracy of GSPET for the measurement of LVEF and LV volume was correlated with a number of factors, including planar(RNA) LVEF, signal to noise ratio, LV volume calculated using X-rays, summed rest score and acquisition scan distance (i.e. the radius of rotation). The accuracy of GBPS for the measurement of LVEF and LV volume was correlated only with the signal level, the signal to noise ratio and the acquisition scan distance. Both GSPET and GBPS provide reliable estimation of global systolic LV function. The better reliability of GBPS and in particular its lower sensitivity to different variables as compared with GSPET favours its use when precise assessment of global systolic LV function is clinically indicated.

Adult↗

Performance of OSEM and depth-dependent resolution recovery algorithms for the evaluation of global left ventricular function in 201Tl gated myocardial perfusion SPECT.

UNLABELLED: It is unknown whether the use of ordered-subsets expectation maximization (OSEM) and depth-dependent resolution recovery (RR) will increase the accuracy of (201)Tl electrocardiogram-gated SPECT (GSPECT) for the measurement of global left ventricular (LV) function. METHODS: Fifty-six patients having both rest (201)Tl GSPECT and planar equilibrium radionuclide angiography (planar(RNA)) on the same day were studied. Twenty-nine patients also had LV conventional contrast angiography (Rx). LV ejection fraction (LVEF), end-diastolic volume (EDV), and end-systolic volume (ESV) were calculated with the quantitative gated SPECT software (QGS) using 4 different processing methods: filtered backprojection (FBP), OSEM, RR + FBP, and RR + OSEM. LVEF calculated with planar(RNA) and LV EDV and ESV calculated with Rx were considered gold standards. LVEF and volumes provided with the GSPECT methods were compared with the gold standard methods. RESULTS: LVEF calculated with GSPECT methods (FBP, OSEM, RR + FBP, and RR + OSEM) were similar (not statistically significant) and correlated well with planar(RNA). On Bland-Altman analysis, the mean +/- SD of absolute difference in LVEF with GSPECT FBP, OSEM, RR + FBP, and RR + OSEM methods versus planar(RNA) were similar, with relatively large limits of agreement. LV volumes calculated with the 4 GSPECT methods were significantly lower but correlated well with Rx LV volumes. LV volumes calculated with FBP and OSEM were lower than those calculated with RR + FBP and RR + OSEM (P < 0.01). On Bland-Altman analysis, the mean +/- SD of absolute difference in LV volumes with FBP, OSEM, RR + FBP, and RR + OSEM versus Rx was, respectively, 56 +/- 45 mL (P < 0.01 vs. the other 3 methods), 57 +/- 45 mL (P < 0.01 vs. the other 3 methods), 43 +/- 48 mL, and 46 +/- 47 mL, with correspondingly large limits of agreement. The variance of random error did not differ between FBP, OSEM, RR + FBP, and RR + OSEM for either LVEF or volumes. CONCLUSION: OSEM and FBP presented similar accuracy for LVEF and volume measured with the QGS software. Their combination with depth-dependent RR provided similar LVEF but more accurate LV volumes.

Algorithms↗

Inability of 99mTc-ciprofloxacin scintigraphy to discriminate between septic and sterile osteoarticular diseases.

UNLABELLED: Ciprofloxacin labeled with (99m)Tc specifically binds to various bacteria. Thus, it potentially constitutes a specific marker allowing discrimination between septic arthritis/osteomyelitis and aseptic osteoarticular diseases. The aim of this prospective study was to evaluate such properties in patients with skeletal diseases. METHODS: We prospectively investigated 2 groups of patients: patients with suspected osteoarticular infections (G1, n = 16) and a control group of patients with a presentation of osteoarticular diseases and no sign suggestive of infection (G2, n = 11). All had clinical, biologic, and radiologic evaluations and had 1-, 4-, and 24-h images from (99m)Tc-ciprofloxacin scintigraphy (370 MBq) before planned biopsy or surgery. For 23 patients, the scintigraphic results were compared with histologic and bacteriologic analyses of biopsy tissue samples; for 4 patients, the scintigraphic results were compared with the findings from 23 +/- 5 mo of follow-up. RESULTS: In G1, (99m)Tc-ciprofloxacin findings were true-positive in all 11 infected sites, true-negative in 2 cases, and false-positive in 3. In G2, (99m)Tc-ciprofloxacin was true-negative in 4 cases and false-positive in 7. Neither the location of (99m)Tc-ciprofloxacin activity nor its intensity or kinetics between 1, 4, and 24 h allowed discrimination between infection and aseptic diseases (sterile loosened joint replacement, pseudoarthrosis, or arthrosis). Sensitivity, specificity, and accuracy were 100%, 37.5%, and 63%. CONCLUSION: (99m)Tc-Ciprofloxacin scintigraphy showed good sensitivity and a high negative predictive value for the detection of bone and joint infection, but it did not discriminate between infected and aseptic osteoarticular diseases in symptomatic patients referred for surgery.

Adult↗

Detection of neuroendocrine tumors: 99mTc-P829 scintigraphy compared with 111In-pentetreotide scintigraphy.

UNLABELLED: The aim of this study was to evaluate the diagnostic value of a new somatostatin analog, 99mTc-P829, compared with that of 111In-pentetreotide. METHODS: Forty-three patients (32 men, 11 women; age range, 24-78 y; mean age, 56 y) with biologically or histologically proven neuroendocrine tumors were prospectively included: 11 patients with Zollinger-Ellison syndrome, 16 patients with carcinoid tumors, and 16 patients with other types of functioning (n = 6) or nonfunctioning (n = 10) endocrine tumors. 111In-Pentetreotide planar images (head, chest, abdomen, and pelvis) were obtained 4 and 24 h after injection of 10 microg somatostatin analog labeled with 148 +/- 17 MBq 111In, and SPECT was performed 24 h after injection. Similar (99m)Tc-P829 planar images were obtained at 1, 4-6, and 24 h after injection of 50 microg peptide labeled with 991.6 +/- 187.59 MBq 99mTc. Abdominal SPECT was performed 4-6 h after injection. RESULTS: 111In-Pentetreotide detected 203 tumoral sites in 39 (91%) of 43 patients, whereas 99mTc-P829 detected 77 sites in 28 (65%) of 43 patients (P < 0.005). In the liver, 129 sites (in 24 patients) were detected by 111In-pentetreotide scintigraphy and 34 sites (in 10 patients) were detected by 99mTc-P829 scintigraphy. CONCLUSION: In patients with endocrine tumors, the detection rate of 99mTc-P829 scintigraphy was lower than that of 111In-pentetreotide scintigraphy, which appeared to be more sensitive, especially for liver metastases.

Carcinoid Tumor↗

Discordance between exercise SPECT lung Tl-201 uptake and left ventricular transient ischemic dilation in patients with CAD.

BACKGROUND: In patients with coronary artery disease (CAD), the characteristics of those with discordant exercise thallium 201 single photon emission computed tomography (SPECT) lung uptake (lung-to-heart [L/H] ratio) and left ventricular (LV) transient ischemic dilation (LVTID) are not well defined. METHODS AND RESULTS: The population included 310 patients having exercise Tl-201 SPECT and coronary angiography. The population was subclassified into 4 subgroups: increased L/H ratio only, increased LVTID only, both, and neither. The L/H ratio was weakly correlated to LVTID (r = 0.18). The L/H ratio was correlated to the summed difference score (r = 0.26), summed rest score (r = 0.31), summed stress score (r = 0.5), and rest and stress LV volume (r = 0.5 and r = 0.54, respectively). LVTID was only correlated to the summed difference score (r = 0.32) and stress LV volume (r = 0.17). Increased LVTID only was associated with more frequent ischemia and patients with it tended to be more extensively ischemic, as compared with patients with increased L/H ratio only, but had a similar angiographic extent of CAD. These results were independent of prior myocardial infarction variable. CONCLUSIONS: As compared with patients with increased L/H ratio alone, patients with increased LVTID alone are more frequently ischemic but have a similar angiographic extent of CAD. Increased L/H ratio was correlated to both rest and postexercise LV volume, whereas increased LVTID was correlated only to postexercise LV volume.

Aged↗

Automatic quantification of right ventricular function with gated blood pool SPECT.

BACKGROUND: Quantification of right ventricular (RV) function is clinically relevant for the risk stratification and follow-up of patients with a wide spectrum of disease. This can be achieved with electrocardiography-gated blood pool single photon emission computed tomography (GBPS). We aimed to evaluate the accuracy of the completely automatic QBS GBPS processing software as compared with equilibrium planar radionuclide angiography (RNA) and with a GBPS manual segmentation method (GBPS(35%)) for the measurement of global RV ejection fraction (EF), taking the first-pass RNA (FP-RNA) as the gold standard. In parallel, we compared the RVEF, RV end-diastolic volume (EDV), and RV end-systolic volume (ESV) provided by QBS and GBPS(35%). METHODS AND RESULTS: The population included 85 patients with chronic post-embolic pulmonary hypertension. Twenty-one patients were excluded because of unsuccessful FP-RNA. Intraobserver and interobserver RVEF, RVEDV, and RVESV reproducibilities encountered with planar RNA, QBS, and GBPS(35%) were similar and compared favorably with those calculated with FP-RNA for RVEF. Mean RVEF was different between all methods. RVEF calculated with FP-RNA was better correlated to QBS (r = 0.68) and GBPS(35%) (r = 0.70) than to planar RNA (r = 0.59). RVEDV and RVESV with QBS were lower than with GBPS(35%), by 29% +/- 14% and 36% +/- 13%, respectively. RVEDV and RVESV with QBS were highly correlated to corresponding GBPS(35%) values: r = 0.88 and r = 0.91, respectively. CONCLUSION: As opposed to FP-RNA, GBPS is highly successful for the quantification of RV function. Both QBS and GBPS(35%) provide RVEF values similarly well correlated to FP-RNA and performed better than planar RNA. RVEF, RVEDV, and RVESV provided by QBS and GBPS(35%) are highly correlated. All of these RV functional measurements require further validation versus a better gold standard before their accuracy can be established.

Algorithms↗

Identification of extensive coronary artery disease: incremental value of exercise Tl-201 SPECT to clinical and stress test variables.

BACKGROUND: The ability of the size of a total myocardial perfusion defect (MPD) to detect extensive coronary artery disease (CAD) is currently suboptimal with exercise thallium 201 single photon emission computed tomography (SPECT). To improve its performance, exercise electrocardiography and indirect scintigraphic markers of extensive CAD were proposed (increased right ventricular Tl-201 uptake, lung-to-heart [L/H] ratio, and left ventricular transient ischemic dilation ratio). We aimed to determine the additive value of these criteria for the detection of extensive CAD. METHODS AND RESULTS: The population included 338 patients who underwent exercise Tl-201 SPECT and coronary angiography. Patients were classified as having extensive CAD (left main, multivessel, or 1-vessel proximal left anterior descending CAD) or limited CAD (1-vessel disease other than proximal left anterior descending CAD or no CAD). First, Tl-201 SPECT provided higher diagnostic value than exercise electrocardiography. Second, age, percent target heart rate achieved, total MPD, and L/H ratio were independent predictors of extensive CAD. Third, visually estimated abnormal right ventricular Tl-201 uptake did not present additional information. Fourth, L/H ratio presented a higher diagnostic accuracy than left ventricular transient ischemic dilation ratio. CONCLUSIONS: With exercise Tl-201 SPECT, age, percent target heart rate achieved, total MPD, and L/H ratio were independent predictors of extensive CAD.

Aged↗