High-resolution ultrasonic imaging using fast two-dimensional homomorphic filtering.

A new method for two-dimensional deconvolution of medical ultrasonic images is presented. The spatial resolution of the deconvolved images is much higher compared to the common images of the fundamental and second harmonic. The deconvolution also results in a more distinct speckle pattern. Unlike the most published deconvolution algorithms for ultrasonic images, the presented technique can be implemented using currently available hardware in real-time imaging, with a rate up to 50 frames per second. This makes it attractive for application in the current ultrasound scanners. The algorithm is based on two-dimensional homomorphic deconvolution with simplified assumptions about the point spread function. Broadband radio frequency image data are deconvolved instead of common fundamental harmonic data. Thus, information of both the first and second harmonics is used. The method was validated on image data recorded from a tissue-mimicking phantom and on clinical image data.

Algorithms↗

Superresolution of ultrasound images using the first and second harmonic signal.

This paper presents a new method of blind two-dimensional (2-D) homomorphic deconvolution and speckle reduction applied to medical ultrasound images. The deconvolution technique is based on an improved 2-D phase unwrapping scheme for pulse estimation. The input images are decomposed into minimum-phase and allpass components. The 2-D phase unwrapping is applied only to the allpass component. The 2-D phase of the minimum-phase component is derived by a Hilbert transform. The accuracy of 2-D phase unwrapping is also improved by processing small (16 x 16 pixels) overlapping subimages separately. This takes the spatial variance of the ultrasound pulse into account. The deconvolution algorithm is applied separately to the first and second harmonic images, producing much sharper images of approximately the same resolution and different speckle patterns. Speckle reduction is made by adding the envelope images of the deconvolved first and second harmonic images. Neither the spatial resolution nor the frame rate decreases, as the common compounding speckle reduction techniques do. The method is tested on sequences of clinical ultrasound images, resulting in high-resolution ultrasound images with reduced speckle noise.

Algorithms↗