PubMed Health⌕ Search

Biomedical subjects

Rafael Cela

Publications and source records attributed to Rafael Cela.

29 records · Page 2Linked to original sources

Application of solid-phase microextraction to the study of the photochemical behaviour of five priority pesticides: "on-fiber" and aqueous photodegradation.

Solid-phase microextraction (SPME) is applied to study the photochemical degradation of five priority pesticides: atrazine, alachlor, aldrin, dieldrin, endrin. Analyses were carried out by gas chromatography-mass spectrometry. The possibility of studying the photochemical degradation of the target compounds in solid-phase microextraction fibers, "photo-SPME", is evaluated employing different SPME coatings. The target analytes were extracted from aqueous solutions using different commercial coatings and then, the fibers were exposed to UV light. Results indicated that on-fiber photodegradation takes place in a considerably major extent using PDMS coating for an irradiation time of 30min. On-fiber photodegradation kinetics of each analyte were determined by UV irradiation of the PDMS for different times. A large number of photoproducts were generated and they were tentatively identified by means of their mass spectra and with the aid of literature. In this way, main photodegradation mechanisms could be postulated. Aqueous photodegradation studies followed by SPME were performed and compared with photo-SPME. All the photoproducts detected in the aqueous experiments were previously found in the photo-SPME experiments. This study shows the potential of photo-SPME to evaluate the photo-transformation of organic pollutants.

Gas Chromatography-Mass Spectrometry↗

Solid-phase microextraction-gas chromatography-mass spectrometry for the analysis of selective serotonin reuptake inhibitors in environmental water.

The continuous contamination of surface waters by pharmaceuticals is of most environmental concern. Selective serotonin reuptake inhibitors (SSRIs) are drugs currently prescribed for the treatment of depressions and other psychiatric disorders and then, they are among the pharmaceuticals that can occur in environmental waters. Solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry has been applied to the extraction of five SSRIs--venlafaxine, fluvoxamine, fluoxetine, citalopram and sertraline--from water samples. Some of the analytes were not efficiently extracted as underivatized compounds and so, an in situ acetylation step was introduced in the sample preparation procedure. Different parameters affecting extraction efficiency such as extraction mode, fiber coating and temperature were studied. A mixed-level fractional factorial design was also performed to simultaneously study the influence of other five experimental factors. Finally, a method based on direct SPME at 100 degrees C using polydimethylsiloxane-divinylbenzene fibers is proposed. The performance of the method was evaluated, showing good linearity and precision. The detection limits were in the sub-ng/mL level. Practical applicability was demonstrated through the analysis of real samples. Recoveries obtained for river water and wastewater samples were satisfactory in all cases. An important aspect of the proposed method is that no matrix effects were observed. Two of the target compounds, venlafaxine and citalopram, were detected and quantified in a sewage water sample.

Gas Chromatography-Mass Spectrometry↗

Development of a sensitive methodology for the analysis of chlorobenzenes in air by combination of solid-phase extraction and headspace solid-phase microextraction.

In this study, a combination of solid-phase extraction (SPE) and solid-phase microextraction (SPME) has been used to determine chlorobenzenes in air. Analytes were sampled by pumping a known volume of air through a porous polymer (Tenax TA). Then, the adsorbent was transferred into a glass vial and SPME was performed. The quantification was carried out using gas chromatography (GC)-electron-capture detection or GC-MS. Several SPME coatings (100 microm poly(dimethylsiloxane) (PDMS), 75 microm Carboxen (CAR)-PDMS, 65 microm PDMS-divinylbenzene (DVB), 65 microm PDMS-DVB and 85 microm polyacrylate (PA) were evaluated, obtaining the highest responses with Carbowax (CW)- PDMS for the most volatile chlorobenzenes, and with PDMS-DVB or CW-DVB fibers for the semivolatile compounds. To optimize some other factors that could affect the SPME step, a factorial design was used. Kinetic studies of the SPME process were also performed. Concerning the SPE step, breakthrough was studied, showing that 2.5 m3 of air could be processed without losses of the most volatile compounds. The performance of the method was evaluated. External calibration, which does not require the complete sampling process, demonstrated to be suitable, obtaining good linearity (R2 > 0.99) for all chlorobenzenes. Recovery studies were performed at two concentration levels (4 and 40 ng/m3), obtaining quantitative recoveries (>80%). Limits of detection at the sub ng/m3 were achieved for all the target compounds.

Air↗

Study of the photoinduced degradation of polycyclic musk compounds by solid-phase microextraction and gas chromatography/mass spectrometry.

Polycyclic musks are widely used synthetic fragrances that have been identified during the last few years in biota samples and environmental matrices. Nevertheless, there is a lack of information concerning the photodegradation behavior of these compounds. In this work, the photoinduced degradation of six polycyclic musk compounds (Cashmeran, Celestolide, Phantolide, Galaxolide, Traseolide and Tonalide) was studied using a solid-phase microextraction (SPME) fiber as support. Musk fragrances were extracted from aqueous solutions using SPME fibers that were subsequently exposed to ultraviolet (UV) irradiation for different times. To study the degradation kinetics and to tentatively identify the photoproducts generated, gas chromatography coupled to ion trap mass spectrometry was used. Aqueous photodegradation studies were also performed. The on-fiber photodegradation approach avoids the need for further extraction processes and makes the identification of photoproducts easier, due to their higher concentration on the fibers. All musk compounds were easily photodegraded, suggesting that UV irradiation could work as a decontamination tool for these musks.

Journal Article↗

Determination of musk compounds in sewage treatment plant sludge samples by solid-phase microextraction.

Headspace solid-phase microextraction, followed by GC-MS analysis is presented as a suitable technique for the determination of musk compounds in sewage treatment plant sludge. Five polycyclic musks (celestolide, phantolide, traseolide, galaxolide and tonalide) and four nitro musks (musk xylene, musk moskene, musk tibetene and musk ketone) were considered in the optimisation of the analytical method. The influence of extraction temperature, fibre coating, agitation, pH and salting out on the efficiency of the extraction along with the extraction kinetics were studied. An extraction temperature of 100 degrees C and sampling the headspace over the stirred sludge sample using polydimethylsiloxane -divinylbenzene as fibre coating lead to effective extraction. The method proposed is very simple and yields high sensitivity, good linearity and repeatability for all the analytes with limits of detection at the sub-ng/g level. The total analysis time, including extraction and GC analysis, was only 40 min, and no manipulation of the sample was required.

Fatty Acids, Monounsaturated↗

On-fiber photodegradation after solid-phase microextraction of p,p'-DDT and two of its major photoproducts, p,p'-DDE and p,p'-DDD.

The potential of performing photochemical studies in solid phase microextraction (SPME) fibers, "photo-SPME", to study the photodegradation of p,p'-DDT and two of its major degradation products, p,p'-DDE and p,p'-DDD, is shown. Analyses were carried out by gas chromatography mass spectroscopy detection. DDT was extracted from aqueous solutions using five different commercial coatings. The fibers were then exposed to UV light emitted by a low-pressure mercury lamp. After 30 min of irradiation, the degradation of DDT only occurred in polydimethylsiloxane fibers. The on-fiber degradation kinetics of p,p'-DDT was studied from 2 to 60 min. A large number of photoproducts were generated and their kinetic behavior was studied. In order to clarify the possible photoreaction pathways for DDT, individual water solutions containing p,p'-DDD or p.p'-DDE were prepared and photo-SPME was performed for each compound at different irradiation times. On the basis of the photoproducts identified, some photodegradation pathways are proposed. Finally, aqueous photodegradation studies followed by SPME were performed and compared to the photo-SPME. This work will show the enormous potential of photo-SPME to perform photodegradation studies.

DDT↗

Optimization of a derivatization-solid-phase microextraction method for the analysis of thirty phenolic pollutants in water samples.

Solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry has been applied to the extraction of 30 phenol derivatives from water samples. Analytes were in situ acetylated and headspace solid-phase microextraction was performed. Different parameters affecting extraction efficiency were studied. Optimization of temperature, type of microextraction fiber and volume of sample has been done by means of a mixed-level categorical experimental design, which allows to study main effects and second order interactions. Five different fiber coatings were employed in this study; also, extraction temperature was studied at three levels. Both factors, fiber coating and extraction temperature, were important to achieve high sensitivity. Moreover, these parameters showed a significant interaction, which indicates the different kinetic behavior of the SPME process when different coatings are used. It was found that 75 microm carboxen-polydimethylsiloxane and 100 microm polydimethylsiloxane, yield the highest responses. The first one is specially appropriated for phenol, methylphenols and low chlorinated chlorophenols and the second one for highly chlorinated phenols. The two methods proposed in this study shown good linearity and precision. Practical applicability was demonstrated through the analysis of a real sewage water sample, contaminated with phenols.

Gas Chromatography-Mass Spectrometry↗

Optimisation of a solid-phase microextraction method for synthetic musk compounds in water.

A solid-phase microextraction method (SPME) for determining trace levels of synthetic musk fragrances in residual waters has been developed. Six polycyclic musks (cashmeran, phantolide, celestolide, traseolide, galaxolide and tonalide), and a macrocyclic musk (ambrettolide) have been analysed. A detailed study of the different parameters affecting the extraction process is presented. The main important factors affecting the microextraction process have been studied and optimised by means of a categorical factorial design. Two extraction modes (direct SPME and headspace SPME) were tried at different extraction temperatures using four different fiber coatings [polydimethylsiloxane (PDMS), Carboxen (CAR)-PDMS, PDMS-divinylbenzene (DVB) and Carbowax (CW)-DVB]. An extraction temperature of 100 degrees C sampling the headspace over the sample using CAR-PDMS or PDMS-DVB as fiber coatings were found to be the experimental conditions that lead to a more effective extraction. The method proposed is very simple and yields high sensitivity, with detection limits in the low pg/ml, good linearity and repeatability for all the target compounds. The total analysis time, including extraction and GC analysis, was only 45 min. The optimised method performed well when it was applied to waste water from an urban treatment plant.

Fatty Acids, Monounsaturated↗

Field-amplified sample stacking and nonaqueous capillary electrophoresis determination of complex mixtures of polar aromatic sulfonates.

Nonaqueous CE and field-amplified sample stacking have been used in the determination of complex mixtures of polar aromatic sulfonates (AS; mainly benzene- and naphthalenesulfonates) of environmental concern. The analytical procedure consists of an on-column aqueous sample enrichment, followed by the nonaqueous electrophoretic determination of stacked aromatic sulfonates. Various organic solvents were used as separation medium, acetonitrile and N-methylformamide gave the best results. Optimum capillary electrophoresis separation is obtained with ammonium acetate (25 mM) dissolved in N-methylformamide-methanol (90:10) as background electrolyte. This combined method was applied to the analysis of surface water samples spiked with selected aromatic sulfonates derivatives.

Acetonitriles↗

Rapid determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin in water samples by using solid-phase microextraction followed by gas chromatography with tandem mass spectrometry.

A rapid and simple method of using solid-phase microextraction was developed for determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) in water samples. In this method, the target analyte is extracted from the sample into the polymeric coating of the fused-silica fiber. After exposure, the fiber is thermally desorbed in the heated injection port of the gas chromatograph, and a chromatographic analysis is performed by using low-resolution tandem mass spectrometry. Parameters that may affect the extension of the microextraction process, such as sampling mode, sample volume, temperature, agitation, and sampling time, were studied. Extraction efficiencies for 3 coating fibers were investigated: 100 microm poly(dimethylsiloxane) (PDMS), 65 microm PDMS-divinylbenzene, and 75 microm carboxen-PDMS. Linearity was evaluated (R = 0.999) for a 250-fold concentration range from the fg/mL to the pg/mL level. The 2,3,7,8-TCDD was detected at the fg/mL level when the headspace over the water sample was sampled for 60 min; the limit of detection obtained was better than that of Method 8280B of the U.S. Environmental Protection Agency. The proposed method performed well when applied to the analysis of tap water, lake water, and seawater samples.

Adsorption↗

Application of strategically designed sample composition to the rapid analytical screening of milk samples for polychlorinated biphenyls.

Strategically designed sample composition (SSC) is a new technique that decreases the number of analytical determinations needed in routine screening to as few as the number of original sample specimens while providing information that is specific to them. Although this new technique has been applied to environmental studies, this paper describes its first application to food safety studies. Contamination of milk samples with polychlorinated biphenyls (PCBs) was chosen as a case study to show the usefulness and potential of the SSC technique with a fast analytical procedure that involves saponification of the samples and solid-phase microextraction of the PCBs. A total of 20 sample specimens can be analyzed in 11 determinations with excellent predictions of the positive samples and the concentration levels of the contaminants. The robustness of the strategy was investigated and demonstrated.

Animals↗