Gas chromatography-microchip atmospheric pressure chemical ionization-mass spectrometry.

An atmospheric pressure chemical ionization (APCI) microchip is presented for combining a gas chromatograph (GC) to a mass spectrometer (MS). The chip includes capillary insertion channel, stopper, vaporizer channel, nozzle and nebulizer gas inlet fabricated on the silicon wafer, and a platinum heater sputtered on a glass wafer. These two wafers are joined by anodic bonding creating a two-dimensional version of an APCI microchip. The sample from GC is directed via heated transfer line capillary to the vaporizer channel of the APCI chip. The etched nozzle forms narrow sample plume, which is ionized by an external corona discharge needle, and the ions are analyzed by a mass spectrometer. The GC-microchip APCI-MS combination provides an efficient method for qualitative and quantitative analysis. The spectra produced by microchip APCI show intensive protonated molecule and some fragmentation products as in classical chemical ionization for structure elucidation. In quantitative analysis the GC-microchip APCI-MS showed good linearity (r(2) = 0.9989) and repeatability (relative standard deviation 4.4%). The limits of detection with signal-to-noise ratio of three were between 0.5 and 2 micromol/L with MS mode using selected ion monitoring and 0.05 micromol/L with MS/MS using multiple reaction monitoring.

Anisoles↗

Capillary liquid chromatography-microchip atmospheric pressure chemical ionization-mass spectrometry.

A miniaturized nebulizer chip for capillary liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (capillary LC-microchip APCI-MS) is presented. The APCI chip consists of two wafers, a silicon wafer and a Pyrex glass wafer. The silicon wafer has a DRIE etched through-wafer nebulizer gas inlet, an edge capillary insertion channel, a stopper, a vaporizer channel and a nozzle. The platinum heater electrode and pads for electrical connection were patterned on to the Pyrex glass wafer. The two wafers were joined by anodic bonding, creating a microchip version of an APCI-source. The sample inlet capillary from an LC column is directly connected to the vaporizer channel of the APCI chip. The etched nozzle in the microchip forms a narrow sample plume, which is ionized by an external corona needle, and the formed ions are analyzed by a mass spectrometer. The nebulizer chip enables for the first time the use of low flow rate separation techniques with APCI-MS. The performance of capillary LC-microchip APCI-MS was tested with selected neurosteroids. The capillary LC-microchip APCI-MS provides quantitative repeatability and good linearity. The limits of detection (LOD) with a signal-to-noise ratio (S/N) of 3 in MS/MS mode for the selected neurosteroids were 20-1000 fmol (10-500 nmol l(-1)). LODs (S/N = 3) with commercial macro APCI with the same compounds using the same MS were about 10 times higher. Fast heat transfer allows the use of the optimized temperature for each compound during an LC run. The microchip APCI-source provides a convenient and easy method to combine capillary LC to any API-MS equipped with an APCI source. The advantages and potentials of the microchip APCI also make it a very attractive interface in microfluidic APCI-MS.

Atmospheric Pressure↗

Metabolite profile of sibutramine in human urine: a liquid chromatography-electrospray ionization mass spectrometric study.

We present a detailed experimental approach to detection and subsequent structural characterization of unknown metabolites of sibutramine, using liquid chromatography-mass spectrometric techniques. The full-, precursor ion, and constant neutral loss scan modes of a triple quadrupole mass spectrometer were used for screening sibutramine metabolites in human urine. The structural assessment of unknown metabolites was based on MSn ion trap mass spectrometric analysis and comparison of MSn spectra between the standards and compounds detected. Two phase-I (M1 and M2) and eight phase-II (M3-M6) metabolites of sibutramine were found in human urine. Metabolites M1 and M2, which were found as minor metabolites, originated from N-demethylation of sibutramine. Carbamoyl glucuronides formed from metabolites M1, M2, and their hydroxylated analogs were the main metabolites of sibutramine and were characterized by tandem mass spectrometric analysis and by the chemical modification of their structure. We demonstrate the usefulness of the chemical derivatization approach for estimation of the site of glucuronidation and propose the formation of hydroxylated regioisomers of metabolites M4 and M6.

Adult↗

Desorption electrospray ionization mass spectrometry for the analysis of pharmaceuticals and metabolites.

The performance of desorption electrospray ionization (DESI) in the analysis of a group of pharmaceuticals and their glucuronic acid conjugates is reported. The suitability of different sprayer solvents and different surfaces was examined. In the positive ion mode, water/methanol/trifluoroacetic acid performed best, whereas, in the negative ion mode, water/methanol/ammonium hydroxide was found to be the most suitable spray solvent. Of the surfaces investigated, polymethylmethacrylate (PMMA) was found to give the best performance in terms of sensitivity. Spray solution flow rate and the distance of the sprayer tip from the surface were also found to have significant effects on the signal intensity. Analytes with basic groups efficiently formed the corresponding protonated molecules in the positive ion mode, whereas acidic analytes, such as the glucuronic acid conjugates, formed intense signals due to the deprotonated molecules in the negative ion mode. Ionization of neutral compounds was less efficient and in many cases it was achieved through adduct formation with simple anions or cations.

Molecular Structure↗

Feasibility of different mass spectrometric techniques and programs for automated metabolite profiling of tramadol in human urine.

The purpose of the study was to determine the advantages of different mass spectrometric instruments and commercially available metabolite identification programs for metabolite profiling. Metabolism of tramadol hydrochloride and the excretion of it and its metabolites into human urine were used as a test case because the metabolism of tramadol is extensive and well known. Accurate mass measurements were carried out with a quadrupole time-of-flight mass spectrometer (Q-TOF) equipped with a LockSpray dual-electrospray ionization source. A triple quadrupole mass spectrometer (QqQ) was applied for full scan, product ion scan, precursor ion scan and neutral loss scan measurements and an ion trap instrument for full scan and product ion measurements. The performance of two metabolite identification programs was tested. The results showed that metabolite programs are time-saving tools but not yet capable of fully automated metabolite profiling. Detection of non-expected metabolites, especially at low concentrations in a complex matrix, is still almost impossible. With low-resolution instruments urine samples proved to be challenging even in a search for expected metabolites. Many false-positive hits were obtained with the automated searching and manual evaluation of the resulting data was required. False positives were avoided by using the higher mass accuracy Q-TOF. Automated programs were useful for constructing product ion methods, but the time-consuming interpretation of mass spectra was done manually. High-quality MS/MS spectra acquired on the QqQ instrument were used for confirmation of the tramadol metabolites. Although the ion trap instrument is of undisputable benefit in MS(n), the low mass cutoff of the ion trap made the identification of tramadol metabolites difficult. Some previously unreported metabolites of tramadol were found in the tramadol urine sample, and their identification was based solely on LC/MS and LC/MS/MS measurements.

Adult↗

Characterization of SU-8 for electrokinetic microfluidic applications.

The characterization of SU-8 microchannels for electrokinetic microfluidic applications is reported. The electroosmotic (EO) mobility in SU-8 microchannels was determined with respect to pH and ionic strength by the current monitoring method. Extensive electroosmotic flow (EOF), equal to that for glass microchannels, was observed at pH > or =4. The highest EO mobility was detected at pH > or =7 and was of the order of 5.8 x 10(-4) cm(2) V(-1) s(-1) in 10 mM phosphate buffer. At pH < or =3 the electroosmotic flow was shown to reverse towards the anode and to reach a magnitude of 1.8 x 10(-4) cm(2) V(-1) s(-1) in 10 mM phosphate buffer (pH 2). Also the zeta-potential on the SU-8 surface was determined, employing lithographically defined SU-8 microparticles for which a similar pH dependence was observed. SU-8 microchannels were shown to perform repeateably from day to day and no aging effects were observed in long-term use.

Journal Article↗

Rapid simultaneous determination of metabolic clearance of multiple compounds catalyzed in vitro by recombinant human UDP-glucuronosyltransferases.

The purpose of this study was to test the applicability of n-in-one (cocktail) incubations in the determination of intrinsic clearance (Cl(int)) as the slope of the linear portion of the Michaelis-Menten curve (velocity V vs. substrate concentration [S]) where substrate concentrations were low. A rapid, sensitive, and selective liquid chromatography tandem mass spectrometry (LC/MS/MS) method was developed for the analysis of samples produced by single-substrate and n-in-one (seven substrates: entacapone, 17beta-estriol, umbelliferone, 4-methylumbelliferone, tolcapone, hydroxyquinoline, and paracetamol) incubations conducted in 96-well plates with different recombinant UDP-glucuronosyltransferases (UGTs). The Cl(int) values obtained with n-in-one incubations were compared with those obtained in single-compound incubations and with V(max)/K(m) values determined by estimating the enzyme kinetic parameters V(max) and K(m) from the Michaelis-Menten curve. When substrate concentrations were well below their K(m) values, Cl(int) values determined as the slope of the linear part of the Michaelis-Menten fitting correlated well with the values determined as V(max)/K(m) ratios from the Michaelis-Menten curve. The correlation between Cl(int) values determined in single-substrate and n-in-one incubations was high as well. Together, the n-in-one incubations, the determination of Cl(int) values as the slope of the linear part of the Michaelis-Menten fitting, and LC/MS/MS as an analytical method proved to be effective approaches for increasing throughput in the first-phase screening of metabolic properties.

Catechols↗

Analysis of small molecules by ultra thin-layer chromatography-atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry.

The feasibility of ultra thin-layer chromatography atmospheric pressure matrix-assisted laser desorption ionization mass spectrometry (UTLC-AP-MALDI-MS) has been studied in the analysis of small molecules. Because of a thinner adsorbent layer, the monolithic UTLC plates provide 10-100 times better sensitivity in MALDI analysis than conventional high performance thin-layer chromatography (HPTLC) plates. The limits of detection down to a low picomole range are demonstrated by UTLC-AP-MALDI-MS. Other advantages of UTLC over HPTLC include faster separations and lower solvent consumption. The performances of AP-MALDI-MS and vacuum MALDI-MS have been compared in the analysis of small drug molecules directly from the UTLC plates. The desorption from the irregular surface of UTLC plates with an external AP-MALDI ion source combined with an ion trap instrument provides clearly less variation in measurements of m/z values when compared with a vacuum MALDI-time-of-flight (TOF) instrument. The performance of the UTLC-AP-MALDI-MS method has been applied successfully to the purity analysis of synthesis products produced by solid-phase parallel synthesis method.

Atmospheric Pressure↗

Fabrication of enclosed SU-8 tips for electrospray ionization-mass spectrometry.

We describe a novel electrospray tip design for MS which is fabricated completely out of SU-8 photoepoxy. A three-layer SU-8 fabrication process provides fully enclosed channels and tips. The tip shape and alignment of all SU-8 layers is done lithographically and is therefore very accurate. Fabrication process enables easy integration of additional fluidic functions on the same chip. Separation channels can be made with exactly the same process. Fluidic inlets are made in SU-8 during the fabrication process and no drilling or other postprocessing is needed. Channels have been fabricated and tested in the size range of 10 microm x 10 microm-50 microm x 200 microm. Mass spectrometric performance of the tips has been demonstrated with both pressure-driven flow and EOF. SU-8 microtips have been shown to produce stable electrospray with EOF in a timescale of tens of minutes. With pressure driven flow stable spray is maintained for hours. Taylor cone was shown to be small in volume and well defined even with the largest channel cross section. The spray was also shown to be well directed with our tip design.

Epoxy Resins↗

Analysis of acetylcholine and choline in microdialysis samples by liquid chromatography/tandem mass spectrometry.

A sensitive liquid chromatography/electrospray ionisation tandem mass spectrometric (LC/ESI-MS/MS) method was developed for the analysis of acetylcholine and choline in microdialysis samples. A Ringer's solution that contains high (150 mM) concentrations of inorganic salts was used to extract acetylcholine and choline from a rat or mouse brain. The separation of acetylcholine, choline, an internal standard acetyl-beta-methylcholine, endogenous compounds and inorganic cations was achieved with hydrophilic interaction chromatography using a diol column. The eluent consisted of 20 mM ammonium formate (pH 3.3) and acetonitrile (20:80) which is favourable for the ESI process. Limits of detection (signal-to-noise (S/N) ratio = 3) of 0.02 nM (0.2 fmol) for acetylcholine and 1 nM (10 fmol) for choline were observed using standards diluted in Ringer's solution. A good linearity was obtained from the limit of quantitation: 0.1 nM (S/N ratio = 10) to 50 nM (r = 0.999) for acetylcholine and within the concentration range of 100-3500 nM (r = 0.998) for choline. The between-day repeatability of the method was good; RSD was 3.1% at 1 nM level of acetylcholine and 3.5% at 1000 nM level of choline. The recoveries for addition of 1 or 2.5 nM acetylcholine and 0.2 or 1 microM choline in microdialysis balancing samples were between 93 and 101% indicating that no suppressing endogenous compounds were co-eluting with acetylcholine or choline. The developed method was applied to the analysis of microdialysis balancing samples collected from rat and mouse brains.

Acetylcholine↗

Atmospheric pressure photoionization-mass spectrometry with a microchip heated nebulizer.

A novel, microfabricated heated nebulizer chip for atmospheric pressure photoionization-mass spectrometry (APPI-MS) is presented. The chip consists of fluidic and gas inlets, a mixer, and a nozzle etched onto silicon wafer that is anodically bonded to a Pyrex glass wafer, on which an aluminum heater is sputtered. A krypton discharge lamp is used as the source for 10-eV photons to initiate the photoionization process. Dopant, delivered as part of the sample solution, is used to achieve efficient ionization. The use of the microfabricated heated nebulizer with APPI in the analysis of four analytes is demonstrated, and the spectra are compared to those obtained with a conventional APPI source. Ionization in positive and negative ion modes was successfully achieved and the spectra were mainly similar to those obtained with conventional APPI, indicating that the ionization in microfabricated and conventional APPI sources takes place by the same mechanisms. The flow rates with conventional APPI are approximately 100 muL/min, whereas the microchip heated nebulizer allows the use of flow rates 0.05-5 muL/min, thus being compatible with microfluidic separation systems or micro- and nano-LC. A stable signal was demonstrated throughout a 5-h measurement, which proved the excellent stability of the micro-APPI. The same heated nebulizer chip can be used for weeks.

Atmospheric Pressure↗

Development of an ion mobility spectrometer for use in an atmospheric pressure ionization ion mobility spectrometer/mass spectrometer instrument for fast screening analysis.

An ion mobility spectrometer that can easily be installed as an intermediate component between a commercial triple-quadrupole mass spectrometer and its original atmospheric pressure ionization (API) sources was developed. The curtain gas from the mass spectrometer is also used as the ion mobility spectrometer drift gas. The design of the ion mobility spectrometer allows reasonably fast installation (about 1 h), and thus the ion mobility spectrometer can be considered as an accessory of the mass spectrometer. The ion mobility spectrometer module can also be used as an independently operated device when equipped with a Faraday cup detector. The drift tube of the ion mobility spectrometer module consists of inlet, desolvation, drift, and extraction regions. The desolvation, drift and extraction regions are separated by ion gates. The inlet region has the shape of a stainless steel cup equipped with a small orifice. Ion mobility spectrometer drift gas is introduced through a curtain gas line from an original flange of the mass spectrometer. After passing through the drift tube, the drift gas serves as a curtain gas for the ion-sampling orifice of the ion mobility spectrometer before entering the ion source. Counterflow of the drift gas improves evaporation of the solvent from the electrosprayed sample. Drift gas is pumped away from the ion source through the original exhaust orifice of the ion source. Initial characterization of the ion mobility spectrometer device includes determination of resolving power values for a selected set of test compounds, separation of a simple mixture, and comparison of the sensitivity of the electrospray ionization ion mobility spectrometry/mass spectrometry (ESI-IMS/MS) mode with that of the ESI-MS mode. A resolving power of 80 was measured for 2,6-di-tert-butylpyridine in a 333 V/cm drift field at room temperature and with a 0.2 ms ion gate opening time. The resolving power was shown to be dependent on drift gas flow rate for all studied ion gate opening times. Resolving power improved as the drift gas flow increased, e.g. at a 0.5 ms gate opening time, a resolving power of 31 was obtained with a 0.65 L/min flow rate and 47 with a 1.3 L/min flow rate for tetrabutylammonium iodide. The measured limits of detection with ESI-MS and with ESI-IMS/MS modes were similar, demonstrating that signal losses in the IMS device are minimal when it is operated in a continuous flow mode. Based on these preliminary results, the IMS/MS instrument is anticipated to have potential for fast screening analysis that can be applied, for example, in environmental and drug analysis.

Journal Article↗

A new maximum likelihood approach with asymmetric residual distribution for multicomponent mass spectra analysis.

This paper proposes a new maximum likelihood approach for the deconvolution of identity and quantity of individual compounds based on the multicomponent mass spectra measured by mass spectrometry (MS). Mixture analysis of multicomponent mass spectra is, typically, based on a linear multicomponent mass spectrum model, where the compounds of the measured spectra to be solved are explicitly stated and assumed to be known. In many cases, however, the measured spectrum may contain unknown compounds that are not explicitly stated in the model and a commonly used least square (LS) solution fails. Moreover, a standard improvement over the LS method in these cases, namely the M-estimation (ME) approach, also suffers from this same problem. Our method overcomes the limitations of the LS and ME methods by modeling the effect of the unknown compound(s) to the residual of the linear model. The experimental results presented show that this new approach can separate more robustly the complex multicomponent mass spectra into their individual constituents compared to the LS and ME methods.

Air Pollutants↗

Environmental applications of membrane introduction mass spectrometry.

The purpose of this review is to highlight the versatility of membrane introduction mass spectrometry (MIMS) in environmental applications, summarize the measurements of environmental volatile organic compounds (VOCs) accomplished using MIMS, present developments in the detection of semi-volatile organic compounds (SVOCs) and forecast possible future directions of MIMS in environmental applications.

Air Pollutants↗

Computing positional isotopomer distributions from tandem mass spectrometric data.

The isotopomer distributions of metabolites are invaluable pieces of information in the computation of the flux distribution in a metabolic network. We describe the use of tandem mass spectrometry with the daughter ion scanning technique in the discovery of positional isotopomer distributions (PID). This technique increases the possibilities of mass spectrometry since given the same fragment ions, it uncovers more information than the full scanning mode. The mathematics of the new technique is slightly more complicated than the techniques needed by full scanning mode methods. Our experiments, however, show that in practice the inadequacy of the fragmentation of amino acids in the tandem mass spectrometer does not allow uncovering the PID exactly even if the daughter ion scanning is used. The computational techniques have been implemented in a MATLAB application called PIDC (Positional Isotopomer Distribution Calculator).

Alanine↗