Chronic kidney disease in patients with chronic heart failure--impact on intracardiac conduction, diastolic function and prognosis.

BACKGROUND: In patients with chronic heart failure (CHF), chronic kidney disease (CKD) is associated with increased morbidity and mortality, but contributing mechanisms are not well defined. This study tested the impact of CKD on intracardiac conduction, diastolic function and prognosis in patients with underlying CHF. METHODS: We prospectively enrolled 269 patients with stable CHF, of whom 135 had CKD (estimated glomerular filtration rate (eGFR)<60 ml/min/1.73 m(2)). Echo measurements comprised left ventricular dimensions/volumes, ejection fraction, mitral E/A-ratio, deceleration time and tissue Doppler mitral annular velocities (S', E', A'). PQ and QRS intervals were derived from the 12-lead ECG. A cardiac event (cardiac death or urgent cardiac transplantation) was defined as combined study end point. RESULTS: Patients with CKD had longer PQ and QRS intervals, and were in a poorer NYHA functional class as compared to patients without CKD. In patients with CKD, the mitral annular E' velocity was lower, the mitral E/E'-ratio was higher and a restrictive mitral filling pattern was more frequent. By linear regression analysis, PQ and QRS intervals and the mitral E/E'-ratio were inversely related to the eGFR. During a follow-up of 507+/-375 days, 39 patients suffered a cardiac event. In CKD patients, outcome was markedly poorer as compared to those without CKD (event-free survival rate 51% vs. 87% in those without KD, p=0.001) CONCLUSIONS: In patients with CHF, CKD is associated with impaired intracardiac conduction and progressive diastolic dysfunction. Both mechanisms may contribute to increased morbidity and mortality of such patients.

Age Distribution↗

N-terminal pro-brain natriuretic peptide, kidney disease and outcome in patients with chronic heart failure.

BACKGROUND: In patients with chronic heart failure (CHF), N-terminal pro-brain natriuretic peptide (NT-proBNP) provides relevant prognostic information, but its usefulness in the presence of kidney disease has been questioned. METHODS: We prospectively enrolled 142 patients with stable CHF and a wide spectrum of renal function (estimated glomerular filtration rates [eGFRs] ranging from 17.1 to 100.3 ml/min/1.73 m2). Chronic kidney disease, defined as eGFR < 60 ml/min/1.73 m2, was present in 63 patients (44%). NT-proBNP measurements were carried out on a bench-top analyzer (Elecsys 2010). Cardiac death or urgent cardiac transplantation were considered as a combined study end-point. RESULTS: During a follow-up of 383 +/- 237 days, 19 patients underwent a cardiac event (cardiac death, n = 17; urgent cardiac transplantation, n = 2). By multivariate Cox analysis, including clinical and laboratory variables, NT-proBNP and serum hemoglobin were independent prognostic predictors. In patients with NT-proBNP > 1,129 pg/ml, outcome was significantly worse compared to patients with NT-proBNP < 1,129 pg/ml (event-free survival rate 67% vs 94% in those with NT-proBNP < 1,129 pg/ml, p = 0.001). By linear regression analysis, NT-proBNP levels were related to New York Heart Association (NYHA) functional class (R = 0.41, p < 0.001), and inversely related to eGFR (R = -0.29, p = 0.001) and to left ventricular ejection fraction (R = -0.43, p < 0.001). CONCLUSIONS: In CHF patients with and without kidney disease, NT-proBNP provides independent prognostic information. In such patients, NT-proBNP levels are not only reflective of a reduced clearance (i.e., a lower eGFR) but also of the severity of the underlying structural heart disease.

Adult↗

Near fatal arrhythmia induction by an implantable cardioverter defibrillator.

Sudden death among implantable cardioverter defibrillator (ICD) recipients is well known. The underlying mechanism remains unclear in most cases. One possible mechanism is an accidentally induced arrhythmia by the ICD itself. This report describes for the first time a case of a life-threatening ventricular arrhythmia induced by a specific algorithm for ventricular arrhythmia reconfirmation before shock delivery in a fourth-generation ICD.

Arrhythmias, Cardiac↗

Prognostic value of a restrictive mitral filling pattern in patients with systolic heart failure and an implantable cardioverter-defibrillator.

In patients with chronic heart failure and reduced systolic function, an implantable cardioverter-defibrillator (ICD) improves the prognosis, but morbidity and mortality remain high. We attempted to identify the prognostic impact of Doppler echocardiography and QRS duration in such patients. We prospectively enrolled 84 patients with chronic heart failure, an ICD, and impaired systolic function (mean ejection fraction 29 +/- 10%). Echocardiographic measurements included left ventricular dimensions/volumes, ejection fraction, mitral E/A ratio, deceleration time, and tissue Doppler analysis of mitral annular velocities (S', E', A'). A cardiac event (death from pump failure or appropriate ICD therapy, i.e., antitachycardia pacing/shock due to sustained ventricular tachycardia or ventricular fibrillation) was defined as the study end point. During a follow-up of 373 +/- 254 days, 22 patients (26%) had an event (death from pump failure, n = 7; patients who received an appropriate ICD therapy, n = 16). In patients with an event, the QRS duration was longer (169 +/- 41 vs 146 +/- 37 ms, p = 0.023), the mitral E/E' ratio was higher (16.0 +/- 6.5 vs 12.8 +/- 5.9, p = 0.044), and a restrictive filling pattern was more frequent (44% vs 9%, p = 0.017). Stepwise multivariate Cox regression analysis identified a restrictive filling pattern as the only independent predictor of an event (hazard ratio 3.65, 95% confidence interval 1.54 to 8.64, p = 0.003). For patients with a restrictive filling pattern, the outcome was markedly poorer than that for patients with a nonrestrictive pattern (event-free survival rate 38% vs 72%, p = 0.005). In conclusion, in patients with chronic heart failure, an ICD, and systolic dysfunction, a restrictive filling pattern is an independent predictor of adverse cardiac events.

Aged↗

Clinical assessment of a new real time 3D quantitative coronary angiography system: evaluation in stented vessel segments.

BACKGROUND: Foreshortening is a recognized problem that is present in angiography and results from views that are not perpendicular to coronary lesions. This limits visual coronary analysis as well as 2D quantitative coronary angiography systems (QCA). The CardiOp-B System is a 3D image acquisition and processing software system designed as an add-on to conventional X-ray angiography system. CardiOp-B's features include real time and off line analysis with comprehensive 3D reconstruction integrating all of the available information of two 2D vessel angiographies into one 3D image. It was the aim of the study to analyze the accuracy of this new 3D QCA system. METHODS: 3D QCA was performed in 50 patients (age 64 +/- 10.9; 84% male; LV-EF 63 +/- 16%) measuring 61 stents during high-pressure inflation (diameter: 2.25-4 mm; length: 8-32 mm). The obtained values (proximal and distal stent diameter, stent length) were correlated with the predefined size of the stents at the used inflation pressure. RESULTS: The linear correlation for the proximal stent diameter was Stent(prox)= 0.03 + 0.93 x real stent size (r(2) = 0.85). The linear correlation for the distal stent diameter was Stent(distal)= -0.03 + 0.89 x real stent size (r(2) = 0.81). The linear correlation for the stent length was Stent(length)= -0.61 + 1.02 x real stent length (r(2) = 0.98). CONCLUSIONS: The CardiOp-B System(R) is a new 3D QCA system with a high linear correlation between the real vessel size and the obtained vessel dimension. It provides real time or off line accurate and comprehensive diagnostic information to the interventional cardiologist without changing the basic coronary angiography procedure.

Angioplasty, Balloon, Coronary↗

Left bundle branch block in chronic heart failure-impact on diastolic function, filling pressures, and B-type natriuretic peptide levels.

BACKGROUND: For patients with chronic heart failure (CHF), left bundle branch block (LBBB) is associated with impaired systolic function and increased morbidity and mortality, but data on diastolic function are scarce. In this patient population, we attempted to define the impact of LBBB on diastolic function, filling pressures, and brain natriuretic peptide and its circulating N-terminal precursor (NT-proBNP) levels. METHODS: A total of 94 patients with stable CHF (48 with complete LBBB, 46 without intraventricular conduction delay and normal QRS duration) underwent conventional 2-dimensional/Doppler echocardiography and Doppler tissue analysis of mitral annular velocities. As a measure of left ventricular filling pressures, the ratio of peak early mitral flow velocity to peak early diastolic mitral annular velocity was derived. NT-proBNP measurements were carried out on a bench-top analyzer (Elecsys-2010, Roche Diagnostics, Mannheim, Germany). RESULTS: Patients with or without LBBB did not differ with respect to the cause of CHF or ejection fraction, but in LBBB deceleration time was shorter (163 +/- 66 vs 205 +/- 95 milliseconds, P = .021) and a restrictive mitral filling pattern was more frequent (35% vs 11%, P = .005). In such patients, the ratio of peak early mitral flow velocity to peak early diastolic mitral annular velocity was higher (14.5 +/- 6.2 vs 10.6 +/- 5.2, P < .001) and NT-proBNP was elevated (3553 +/- 3725 vs 850 +/- 896 pg/mL, P < .01) as compared with patients without LBBB. CONCLUSION: For patients with CHF and comparable systolic performance, LBBB is associated with more severe diastolic dysfunction, elevated filling pressures, and higher NT-proBNP levels. These findings may contribute to increased morbidity and mortality of such patients.

Blood Pressure↗

[Restrictions for ICD patients in daily life].

Patients with an implantable cardioverter defibrillator (ICD) may experience loss of consciousness. Electromagnetic interference (EMI) may trigger undesired or inhibit necessary therapy in patients with an ICD. Therefore, questions about personal or professional activities for ICD patients arise. Restricting driving or other personal activities has adverse effects on the patient's quality of life. The national Societies of Cardiology provide recommendations for ICD patients concerning driving of motor vehicles. Patients with an ICD that is implanted prophylactically do not have to refrain from driving after recovery from the implantation procedure. Patients with arrhythmias are classified into different groups depending on the risk of recurrence of tachycardias and symptoms. Commercial driving is not allowed for patients with an ICD in Germany except for those with a prophylactic indication without a history of arrhythmias. Those patients may drive small cars but no trucks or busses. Guidelines for medical fitness in commercial or military flying are regulated by the Joint Aviation Authorities (JAA) and ventricular tachycardias are a contraindication for both. Fortunately, loss of consciousness is not dangerous in most jobs. Strong sources of EMI can occur at special workplaces. Patients have to be advised and tested individually concerning their risk for EMI at their employment site before returning safely. Modern life exposes to an increasing amount of EMI. Intact household devices usually do not interfere with ICDs. Mobile phones may interfere with implanted devices. Interaction can be minimized by special precautions like maintaining a distance of minimum 10 cm between mobile phone and ICD. Electronic surveillance systems work differently and have the potential to interact with devices. Patients should be advised to pass those systems with avoiding longer exposure. The presence of an ICD is presently a contraindication for undergoing magnetic resonance imaging (MRI) because of a high risk of destruction of the system with even potential harm to the patient. High-frequency application for electrocautery devices or ablation is possible under certain precautions that have to be planned before. There is a high sensitivity of ICD systems to ionizing radiation with defect of the devices after a cumulative dose > 5 Gy.

Accidents, Traffic↗

Incidence of complications in patients with implantable cardioverter/defibrillator who receive additional transvenous pace/sense leads.

BACKGROUND: Implantation of an additional pace/sense (P/S) lead is commonly used in patients with implantable cardioverter/defibrillators (ICDs) to overcome P/S defects of integrated defibrillation leads (HV-P/S leads). No information is available about the clinical outcome and the incidence of complications in these patients. METHODS: Retrospective analysis was performed in 151 patients (125 male, age 54.9 +/- 13.6 years, LVEF 48.1 +/- 17.8%, CAD in 86 [57%], DCM in 24 [16%], ARVCM in 11 [7%]) who received an additional P/S lead between 1990 and 2002 (54 patients with abdominal and 97 patients with pectoral ICD system). Statistical analysis was done using Kaplan-Meier survival curves. RESULTS: The average follow-up (FU) after implantation of the additional P/S lead was 43 +/- 27 months. In total 117 patients [77.5%] remain implanted; 22 patients died due to cardiac-related reasons. After a FU of 23 +/- 23 months, 43 patients [28.5%] experienced lead-related problems after implantation of the additional P/S lead: oversensing in 23 [53.5%], insulation defect in 3 [7.0%], fracture in 1 [2.3%], system infection in 4 [9.3%], and defect of the HV-P/S lead in 6 [14.0%] patients. The event-free cumulative survival of the additional P/S lead after 1, 2, and 5 years was 87.0%, 79.8%, and 59.4%, respectively (for pectoral leads: 89.6%, 82.0%, and 60.0%, respectively). CONCLUSIONS: Implantation of an additional P/S lead in case of failure of an HV-P/S lead is safe. However, it is associated with a substantial rate of complications during FU. Therefore, extraction of damaged defibrillation leads instead of implantation of P/S leads should be favored.

Aged↗

Usefulness of tissue Doppler imaging for estimation of filling pressures in patients with primary or secondary pure mitral regurgitation.

Mitral annular velocities derived from tissue Doppler (S', E', A') and left ventricular (LV) end-diastolic pressures were obtained in 11 patients with significant primary mitral regurgitation (MR), 26 patients with significant MR secondary to ischemic or dilated cardiomyopathy, and in 29 asymptomatic controls. The mitral E/E' ratio was related significantly to LV end-diastolic pressure in patients with secondary, but not in patients with primary MR. In patients with secondary MR, a mitral E/E' ratio >15 predicted an elevated LV end-diastolic pressure with a sensitivity of 80% and a specificity of 100%. Thus, the mitral E/E' ratio is a reliable estimate of filling pressures only in subjects with significant secondary, but not with significant, primary MR.

Adult↗

Tissue Doppler imaging in patients with moderate to severe aortic valve stenosis: clinical usefulness and diagnostic accuracy.

BACKGROUND: Mitral annular velocities derived from tissue Doppler imaging (TDI) provide information about left ventricular (LV) long-axis function and allow for the assessment of LV filling pressures in selected subsets of patients. It was the aim of this study to assess the usefulness of TDI in patients with moderate to severe aortic valve stenosis (AS). METHODS: Twenty-three patients with moderate to severe AS (mean aortic valve area 0.8 +/- 0.4 cm2), in whom coronary artery disease had been ruled out, and 36 asymptomatic age-matched control subjects underwent assessment of ejection fraction, fractional shortening, and mitral inflow (E, A, E/A ratio). TDI velocities (S', E', A') were derived from the septal mitral annulus. In patients with AS, LV pressure before atrial contraction (LV pre-A pressure), LV end-diastolic pressure, and cardiac index were measured during cardiac catheterization. RESULTS: In patients with AS, systolic (S') and early diastolic mitral annular velocities (E') were significantly reduced in comparison to control subjects (systolic, 5.5 +/- 1.2 vs 8.3 +/- 1.3 cm/s; early diastolic, 5.6 +/- 1.6 vs 10.2 +/- 3.0 cm/s, P <.001 for both comparisons), but ejection fraction, fractional shortening, and cardiac index were normal. In patients with AS, LV pre-A pressures (14 +/- 4 mm Hg) and end-diastolic pressures were high (19 +/- 7 mm Hg). In such patients, the mitral E/E' ratio was significantly related to LV pre-A pressure (r = 0.75, P <.001) and to LV end-diastolic pressure (r = 0.78, P <.001). In patients with AS, an E/E' ratio > or =13 identified an LV end-diastolic pressure >15 mm Hg, with a sensitivity of 93% and a specificity of 88%. CONCLUSIONS: In patients with moderate to severe AS, TDI allows for a reliable, noninvasive estimation of filling pressures. In such patients, systolic long-axis function is impaired even in the presence of normal ejection fraction and cardiac index. Thus, TDI integrates information about systolic and diastolic performance and may be a useful addition in the echocardiographic workup and care of patients with AS.

Aged↗

Vasoactive peptides during long-term follow-up of patients after cardiac transplantation.

BACKGROUND: Vasoactive peptides are accepted indicators of the degree of heart failure and its progression or improvement following medical therapy. Normalization of cardiac hemodynamics by cardiac transplantation (HTx) may lead to normalization of atrial natriuretic peptide (ANP) and brain natriuretic peptide (BNP) plasma levels shortly after the procedure. METHODS: Long-term follow-up was done for 14 consecutive patients, 12 men and 2 women, 49 years of age (range 24 to 64 years). ANP and BNP were measured by radioimmunoassay (RIA) in central venous plasma samples (before breakfast, at steady state) at the following intervals after HTx: 7 to 30 (1), 31 to 60 (2), 61 to 90 (3), 120 to 180 (4) and 210 to 365 (5) days. RESULTS: During follow-up, ANP decreased significantly within 2 months after HTx and continued of this level, whereas BNP decreased continuously without reaching normal values. The mean ratio of ANP:BNP increased from 3.23 to 8.01 during follow-up. Whereas right atrial pressure (RAP), right ventricular pressure (RVP), right ventricular end-diastolic pressure (RVEDP) and pulmonary capillary wedge pressure (PCWP) did not change during follow-up, cardiac output (CO) improved slightly, but significantly from 5.21 liters/min to 5.9 liters/min (p = 0.035). CONCLUSIONS: Normalization of left ventricular function after orthotopic HTx does not induce an early diminution of ANP and BNP plasma levels to normal concentrations. Although elevated ANP concentrations showed only minimal changes within 1 year, BNP decreased significantly as early as 2 months after HTx, without reaching normal values during the year of follow-up. Also, the ratio of ANP and BNP increased significantly from 3.23 to 8.01. These results demonstrate the contribution of other factors beyond cardiac function that determine the levels of these peptides.

Atrial Natriuretic Factor↗

Doppler tissue analysis of mitral annular velocities: evidence for systolic abnormalities in patients with diastolic heart failure.

BACKGROUND: The presence of signs and symptoms of heart failure (HF), abnormal diastolic function and an ejection fraction > 45%, have been defined as diastolic HF (DHF). However, a cut-off value of 45% for ejection fraction seems arbitrary as mild systolic dysfunction may be overlooked. It was the goal of this study to assess the additive information derived from Doppler tissue imaging for patients with DHF. METHODS: As a measure of left ventricular (LV) long-axis function, systolic and diastolic velocities of the mitral annulus (peak, peak early, and peak late) derived from pulsed Doppler tissue imaging were assessed in 36 asymptomatic control subjects, 36 patients with DHF, and 35 patients with systolic HF (SHF). As a measure of overall LV performance, the Tei index (isovolumic contraction time and isovolumic relaxation time divided by ejection time) was assessed. RESULTS: In the DHF group, peak systolic annular velocity was reduced (7.1 +/- 1.2 cm/s) as compared with the control group (9.0 +/- 1.2 cm/s, P <.05), and was even lower in the SHF group (5.0 +/- 0.7 cm/s, P <.01 SHF group vs DHF/control groups). The Tei index was increased in the DHF group (0.53 +/- 0.14) in comparison with the control group (0.39 +/- 0.07, P <.05), and was highest in the SHF group (0.94 +/- 0.43, P <.01 SHF group vs control/DHF groups). Using peak systolic annular velocity < 7.95 cm/s as a cut-off value (derived from receiver operating characteristic curve analysis), patients with DHF were separated from control subjects with a sensitivity of 83% and a specificity of 83%. A Tei index > 0.43 separated patients with DHF and control subjects with a sensitivity of 79% and a specificity of 72%. CONCLUSION: Systolic long-axis LV function is also impaired in patients with DHF, resulting in feasible diagnosis of DHF by Doppler tissue imaging analysis of LV long-axis function and overall LV function with the Tei index.

Aged↗

ICD leads: design and chronic dysfunctions.

The treatment of ventricular tachyarrhythmias has changed over the last 10 years. Implantable cardioverter defibrillators (ICDs), once used only as a last resort therapy, have now become the treatment of choice. This change occurred before the first results of randomized studies on ICD therapy in patients with life-threatening ventricular tachyarrhythmias were published by the end of 1997. Technological advances of ICD therapy, in particular the development of transvenous leads, were to a large extent responsible for this change. Modern leads are characterized by their multilumen design that incorporates straight wires and coiled conductors into a single electrode body. Conductors and insulation are sheathed with additional insulation layers. The most frequently used insulating materials are silicone, polyurethane, and fluoropolymers. Lead failures are an important complication of ICD therapy. Fractured conductors, compression, creeping, or insulation defects from abrasion can cause such lead dysfunctions. Chronically implanted leads will inevitably have an increased risk of failure due to defects despite all technological advances. In the light of improving survival figures in patients with ventricular tachyarrhythmias and increasing numbers of ICD implantations, lead failures are becoming a clinical problem of ever increasing importance. Therefore, the question of which lead types necessitate extraction when a certain failure occurs and which leads can be left in place. Despite continuous improvements in lead extraction systems and growing experience in their use, the extraction of any pacemaker or ICD lead is associated with some risk of complications.

Defibrillators, Implantable↗

Mortality, morbidity, and complications in 3344 patients with implantable cardioverter defibrillators: results fron the German ICD Registry EURID.

ICDs are the therapy of choice in patients with life-threatening ventricular arrhythmias. Mortality, morbidity, and complication rates including appropriate and inappropriate therapies are unknown when ICDs are used in routine medical care and not in well-defined patients included in multicenter trials. Therefore, the data of 3,344 patients (61.1 +/- 12.1 years; 80.2% men; CAD 64.6%, dilated cardiomyopathy 18.9%; NYHA Class I-III: 19.1%, 54.3%, 20.1%, respectively; LVEF > 0.50: 0.234, LVEF 0.30-0.50: 0.472, LVEF < 0.30: 0.293, respectively) implanted in 62 German hospitals between January 1998 and October 2000 were prospectively collected and analyzed as a part of the European Registry of Implantable Defibrillators (EURID Germany). The 1-year survival rate was 93.5%. Patients in NYHA Class III and aLVEF < 0.30 had a lower survival rate than patients in NYHA Class I and a preserved LVEF (0.852 vs 0.975,P = 0.0001). Including the 1-year follow-up, 49.5% of patients had an intervention by the ICD, 39.8% had appropriate ICD therapies, 16.2% had inappropriate therapies. Overall, 1,691 hospital readmissions were recorded. The main causes for hospital readmissions were ventricular arrhythmias (61.3%) and congestive heart failure symptoms (12.9%). Thus, demographic data and mortality of patients treated with an ICD in conditions of standard medical care seems to be comparable and based on, or congruent with, the large secondary preventions trials. When ICDs are used in standard medical care, the 1-year survival rate is high, especially in patients with NYHA Class I and preserved LVEF. However, nearly half of all patients suffer from ICD intervention.

Defibrillators, Implantable↗