PubMed Health⌕ Search

Biomedical subjects

Rainer Heintzmann

Publications and source records attributed to Rainer Heintzmann.

15 recordsLinked to original sources

The sampling limit in fluorescence microscopy.

Sampling in fluorescence microscopy is treated using the concept of the three-dimensional (3D) optical transfer function (OTF). The border of the OTF frequency surface defines the required minimum sampling. The shape of the OTF is derived from simple considerations and valid for far-field high numerical aperture, vector theory. Optimal regular sampling is achieved by a hexagonal grid in 2D, and corresponding hexagonal structures, body-centered cubic (bcc) and hexagonal close-packed (hcp) structures, in 3D. As compared to standard (rectilinear grid) sampling a reduction of 13.4% in 2D and 29.3% in 3D can be achieved with optimized sampling. This reduction in data size is also accompanied by an imaging speed improvement, a reduction of sample bleaching, and can lead to imaging with better signal to noise ratio.

Journal Article↗

Estimating missing information by maximum likelihood deconvolution.

The ability of iteratively constrained maximum likelihood (ML) deconvolution to reconstruct out-of-band information is discussed and exemplified by simulations. The frequency dependent relative energy regain, a novel way of quantifying the reconstruction ability, is introduced. The positivity constraint of ML deconvolution allows reconstructing information outside the spatial frequency bandwidth which is set by the optical system. This is demonstrated for noise-free and noisy data. It is also shown that this property depends on the type of object under investigation. An object is constructed where no significant out-of-band reconstruction is possible. It is concluded that in practical situations the amount of possible out-of-band reconstruction depends on the agreement between reality and the model describing "typical objects" incorporated into the algorithm by appropriate penalty functions.

Journal Article↗

High-resolution image reconstruction in fluorescence microscopy with patterned excitation.

We discuss data treatment strategies in structured illumination microscopy, using simulated and experimental data. In the setup, the illumination pattern is generated by projecting a movable pinhole mask into the sample, and a wide-field fluorescence microscope image is acquired for each pattern position. The structured illumination data obtained from a two-dimensional illumination pattern can be treated by projection strategies such as in video confocal microscopy (sum, maximum, maximum minus minimum, and superconfocal), by a scaled subtraction of the out-of-focus estimate, or by a modified version of the Fourier-space treatment, as is known for data from one-dimensional structured illumination. We investigate the influence of some data processing strategies on unwanted effects such as residual patterning and local deviations from linearity in the reconstructed intensity.

Algorithms↗

The SNARE motif is essential for the formation of syntaxin clusters in the plasma membrane.

In the plasma membrane, syntaxin 1 and syntaxin 4 clusters define sites at which secretory granules and caveolae fuse, respectively. It is widely believed that lipid phases are mandatory for cluster formation, as cluster integrity depends on cholesterol. Here we report that the native lipid environment is not sufficient for correct syntaxin 1 clustering and that additional cytoplasmic protein-protein interactions, primarily involving the SNARE motif, are required. Apparently no specific cofactors are needed because i), clusters form equally well in nonneuronal cells, and ii), as revealed by nanoscale subdiffraction resolution provided by STED microscopy, the number of clusters directly depends on the syntaxin 1 concentration. For syntaxin 4 clustering the N-terminal domain and the linker region are also dispensable. Moreover, clustering is specific because in both cluster types syntaxins mutually exclude one another at endogenous levels. We suggest that the SNARE motifs of syntaxin 1 and 4 mediate specific syntaxin clustering by homooligomerization, thereby spatially separating sites for different biological activities. Thus, syntaxin clustering represents a mechanism of membrane patterning that is based on protein-protein interactions.

Amino Acid Motifs↗

Breaking the resolution limit in light microscopy.

Fluorescent imaging microscopy has been an essential tool for biologists over many years, especially after the discovery of the green fluorescent protein and the possibility of tagging virtually every protein with it. In recent years dramatic enhancement of the level of detail at which a fluorescing structure of interest can be imaged have been achieved. We review classical and new developments in high-resolution microscopy, and describe how these methods have been used in biological research. Classical methods include widefield and confocal microscopy whereas novel approaches range from linear methods such as 4Pi, I(5) and structured illumination microscopy to non-linear schemes such as stimulated emission depletion and saturated structured illumination. Localization based approaches (e.g. PALM and STORM), near-field methods and total internal refraction microscopy are also discussed. As the terms 'resolution', 'sensitivity', 'sampling' and 'precision' are sometimes confused, we explain their clear distinction. Key concepts such as the point spread function and the Abbe limit, which are necessary for an in depth understanding of the presented methods, are described without requiring extensive mathematical training.

Animals↗

Polycomb group protein complexes exchange rapidly in living Drosophila.

Fluorescence recovery after photobleaching (FRAP) microscopy was used to determine the kinetic properties of Polycomb group (PcG) proteins in whole living Drosophila organisms (embryos) and tissues (wing imaginal discs and salivary glands). PcG genes are essential genes in higher eukaryotes responsible for the maintenance of the spatially distinct repression of developmentally important regulators such as the homeotic genes. Their absence, as well as overexpression, causes transformations in the axial organization of the body. Although protein complexes have been isolated in vitro, little is known about their stability or exact mechanism of repression in vivo. We determined the translational diffusion constants of PcG proteins, dissociation constants and residence times for complexes in vivo at different developmental stages. In polytene nuclei, the rate constants suggest heterogeneity of the complexes. Computer simulations with new models for spatially distributed protein complexes were performed in systems showing both diffusion and binding equilibria, and the results compared with our experimental data. We were able to determine forward and reverse rate constants for complex formation. Complexes exchanged within a period of 1-10 minutes, more than an order of magnitude faster than the cell cycle time, ruling out models of repression in which access of transcription activators to the chromatin is limited and demonstrating that long-term repression primarily reflects mass-action chemical equilibria.

Animals↗

New effects in polynucleotide release from cationic lipid carriers revealed by confocal imaging, fluorescence cross-correlation spectroscopy and single particle tracking.

We report on new insights into the mechanisms of short single and double stranded oligonucleotide release from cationic lipid complexes (lipoplexes), used in gene therapy. Specifically, we modeled endosomal membranes using giant unilamellar vesicles and investigated the roles of various individual cellular phospholipids in interaction with lipoplexes. Our approach uses a combination of confocal imaging, fluorescence cross-correlation spectroscopy and single particle tracking, revealing several new aspects of the release: (a) phosphatidylserine and phosphatidylethanolamine are equally active in disassembling lipoplexes, while phosphatidylcholine and sphingomyelin are inert; (b) in contrast to earlier findings, phosphatidylethanolamine alone, in the absence of anionic phosphatidylserine triggers extensive release; (c) a double-stranded DNA structure remains well preserved after release; (d) lipoplexes exhibited preferential binding to transient lipid domains, which appear at the onset of lipoplex attachment to originally uniform membranes and vanish after initiation of polynucleotide release. The latter effect is likely related to phosphatidyleserine redistribution in membranes due to lipoplex binding. Real time tracking of single DOTAP/DOPE and DOTAP/DOPC lipoplexes showed that both particles remained compact and associated with membranes up to 1-2 min before fusion, indicating that a more complex mechanism, different from suggested earlier rapid fusion, promotes more efficient transfection by DOTAP/DOPE complexes.

Lipid Metabolism↗

Fluorescence lifetime imaging in an optically sectioning programmable array microscope (PAM).

BACKGROUND: The programmable array microscopes (PAMs) are a family of instruments incorporating arbitrary control of the patterns of illumination and/or detection. The PAM can be used in sectioning and nonsectioning modes, thereby constituting a useful platform for fluorescence lifetime imaging. METHODS AND RESULTS: We used a PAM for acquisition of optically sectioned and widefield fluorescence lifetime images, in which contrast was increased predominantly by suppressing out-of-focus light contributions. We simulate, display, and discuss the effects of blurring and fluorophore heterogeneity on lifetime imaging in widefield and confocal configurations. CONCLUSION: Sectioning improves the quality of lifetime images of samples with multiple fluorophores or spatially varying Förster resonance energy transfer.

Animals↗

A role for eIF4E and eIF4E-transporter in targeting mRNPs to mammalian processing bodies.

mRNP remodeling events required for the transition of an mRNA from active translation to degradation are currently poorly understood. We identified protein factors potentially involved in this transition, which are present in mammalian P bodies, cytoplasmic foci enriched in 5' --> 3' mRNA degrading enzymes. We demonstrate that human P bodies contain the cap-binding protein eIF4E and the related factor eIF4E-transporter (eIF4E-T), suggesting novel roles for these proteins in targeting mRNAs for 5' --> 3' degradation. Furthermore, fluorescence resonance energy transfer (FRET) studies indicate that eIF4E interacts with eIF4E-T and the putative DEAD box helicase rck/p54 in the P bodies in vivo. RNAi-mediated knockdowns revealed that a subset of P body factors, including eIF4E-T, LSm1, rck/p54, and Ccr4 are required for the accumulation of each other and eIF4E in P bodies. In addition, treatment of HeLa cells with cycloheximide, which inhibits translation, revealed that mRNA is also required for accumulation of mRNA degradation factors in P bodies. In contrast, knockdown of the decapping enzyme Dcp2, which initiates the actual 5' --> 3' mRNA degradation did not abolish P body formation, indicating it first functions after mRNPs have been targeted to these cytoplasmic foci. These data support a model in which mRNPs undergo several successive steps of remodeling and/or 3' trimming until their composition or structural organization promotes their accumulation in P bodies.

Biological Transport↗

RNAi knockdown of hPrp31 leads to an accumulation of U4/U6 di-snRNPs in Cajal bodies.

Cajal bodies (CBs) are subnuclear organelles of animal and plant cells. A role of CBs in the assembly and maturation of small nuclear ribonucleoproteins (snRNP) has been proposed but is poorly understood. Here we have addressed the question where U4/U6.U5 tri-snRNP assembly occurs in the nucleus. The U4/U6.U5 tri-snRNP is a central unit of the spliceosome and must be re-formed from its components after each round of splicing. By combining RNAi and biochemical methods, we demonstrate that, after knockdown of the U4/U6-specific hPrp31 (61 K) or the U5-specific hPrp6 (102 K) protein in HeLa cells, tri-snRNP formation is inhibited and stable U5 mono-snRNPs and U4/U6 di-snRNPs containing U4/U6 proteins and the U4/U6 recycling factor p110 accumulate. Thus, hPrp31 and hPrp6 form an essential connection between the U4/U6 and U5 snRNPs in vivo. Using fluorescence microscopy, we show that, in the absence of either hPrp31 or hPrp6, U4/U6 di-snRNPs as well as p110 accumulate in Cajal bodies. In contrast, U5 snRNPs largely remain in nucleoplasmic speckles. Our data support the idea that CBs may play a role in tri-snRNP recycling.

Carrier Proteins↗

Quantum dot ligands provide new insights into erbB/HER receptor-mediated signal transduction.

The erbB/HER family of transmembrane receptor tyrosine kinases (RTKs) mediate cellular responses to epidermal growth factor (EGF) and related ligands. We have imaged the early stages of RTK-dependent signaling in living cells using: (i) stable expression of erbB1/2/3 fused with visible fluorescent proteins (VFPs), (ii) fluorescent quantum dots (QDs) bearing epidermal growth factor (EGF-QD) and (iii) continuous confocal laser scanning microscopy and flow cytometry. Here we demonstrate that EGF-QDs are highly specific and potent in the binding and activation of the EGF receptor (erbB1), being rapidly internalized into endosomes that exhibit active trafficking and extensive fusion. EGF-QDs bound to erbB1 expressed on filopodia revealed a previously unreported mechanism of retrograde transport to the cell body. When erbB2-monomeric yellow fluorescent protein (mYFP) or erbB3-monomeric Citrine (mCitrine) were coexpressed with erbB1, the rates and extent of endocytosis of EGF-QD and the RTK-VFP demonstrated that erbB2 but not erbB3 heterodimerizes with erbB1 after EGF stimulation, thereby modulating EGF-induced signaling. QD-ligands will find widespread use in basic research and biotechnological developments.

Animals↗

Saturated patterned excitation microscopy with two-dimensional excitation patterns.

The techniques of patterned excitation microscopy (PEM, also referred to in the literature as structured illumination, harmonic excitation light microscopy, or laterally modulated excitation microscopy), has recently been extended to the non-linear regime, permitting a further increase in resolution breaking the Abbe diffraction limit (saturated PEM, saturated patterned excitation microscopy (SPEM)). Fluorescence saturation was suggested as the non-linear effect employed to achieve this aim. Here a two-dimensional extension of the linear and the non-linear patterned excitation technique is introduced and simulations of the expected resolution improvement are presented. The simulations account for photon statistics, a sub-optimal degree of modulation and a high amount of background fluorescence in the sample. The resulting point-spread-functions achieve a full width at half maximum of 215 nm (widefield), 118 nm (linear PEM), and 57 nm (saturated PEM, 9x9 orders). For higher resolution, an increased number of detected photons and of raw data images are required. A potential method for substantially decreasing the required number of raw images in PEM and SPEM is discussed.

Fluorescence↗

Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes.

Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in signal-to-noise ratio. The latter can be increased further with the technique of weighted averaging in Fourier-space. A comparison of 2D and 3D experimental data analysed with subtractive imaging, the equivalent Fourier-space processing of the confocal data only, and Fourier-space weighted averaging is presented.

3T3 Cells↗

High-resolution colocalization of single dye molecules by fluorescence lifetime imaging microscopy.

Conventional fluorescence microscopy can be used to determine the positions of objects in space when those objects are separated by distances greater than several hundred nanometers, as restricted by the diffraction limit of light. Fluorescence microscopy/spectroscopy based on fluorescence resonance energy-transfer techniques can be used to measure separation distances below approximately 10 nm. To fill the gap between these fundamental limits, we have developed an alternative technique for high-resolution colocalization of fluorescent dyes. The technique is based on fluorescence lifetime imaging. Under favorable conditions, the method can be used to distinguish, and to measure the distance between, two dye molecules that are less than 30 nm apart. To demonstrate the method, lifetime images of a mixture of Cy5 and JF9 (rhodamine derivative) molecules statistically adsorbed on a glass surface were acquired and analyzed. Since these two molecular species differ in fluorescence lifetime (for Cy5, tau(f) = 2.0 ns, and for JF9, tau(f) = 4.0 ns), it is possible to assign the contribution of fluorescence of the two dye types to each image pixel using a pattern recognition technique. Since both dye types can be excited using the same laser wavelength, the measurement is free of chromatic aberrations. The results presented demonstrate the first high-precision distance measurements between single conventional fluorescent dyes based solely on fluorescence lifetime.

Journal Article↗

Saturated patterned excitation microscopy--a concept for optical resolution improvement.

The resolution of optical microscopy is limited by the numerical aperture and the wavelength of light. Many strategies for improving resolution such as 4Pi and I5M have focused on an increase of the numerical aperture. Other approaches have based resolution improvement in fluorescence microscopy on the establishment of a nonlinear relationship between local excitation light intensity in the sample and in the emitted light. However, despite their innovative character, current techniques such as stimulated emission depletion (STED) and ground-state depletion (GSD) microscopy require complex optical configurations and instrumentation to narrow the point-spread function. We develop the theory of nonlinear patterned excitation microscopy for achieving a substantial improvement in resolution by deliberate saturation of the fluorophore excited state. The postacquisition manipulation of the acquired data is computationally more complex than in STED or GSD, but the experimental requirements are simple. Simulations comparing saturated patterned excitation microscopy with linear patterned excitation microscopy (also referred to in the literature as structured illumination or harmonic excitation light microscopy) and ordinary widefield microscopy are presented and discussed. The effects of photon noise are included in the simulations.

Computer Simulation↗