PubMed Health⌕ Search

Biomedical subjects

Raj Mutharasan

Publications and source records attributed to Raj Mutharasan.

15 recordsLinked to original sources

Detect of Escherichia coli O157:H7 in ground beef samples using piezoelectric excited millimeter-sized cantilever (PEMC) sensors.

Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors consisting of a piezoelectric and a borosilicate glass layer with a sensing area of 4 mm2 were fabricated. An antibody specific to Escherichia coli (anti-E. coli) O157:H7 was immobilized on PEMC sensors, and exposed to samples containing E. coli O157:H7 (EC) prepared in various matrices: (1) broth, broth plus raw ground beef, and broth plus sterile ground beef without inoculation of E. coli O157:H7 served as controls, (2) 100 mL of broth inoculated with 25 EC cells, (3) 100 mL of broth containing 25 g of raw ground beef and (4) 100 mL of broth with 25 g of sterile ground beef inoculated with 25 EC cells. The total resonant frequency change obtained for the broth plus EC samples were 16+/-2 Hz (n=2), 30 Hz (n=1), and 54+/-2 Hz (n=2) corresponding to 2, 4, and 6h growth at 37 degrees C, respectively. The response to the broth plus 25 g of sterile ground beef plus EC cells were 21+/-2 Hz (n=2), 37 Hz (n=1), and 70+/-2 Hz (n=2) corresponding to 2, 4, and 6 h, respectively. In all cases, the three different control samples yielded a frequency change of 0+/-2 Hz (n=6). The E. coli O157:H7 concentration in each broth and beef samples was determined by both plating and by pathogen modeling program. The results indicate that the PEMC sensor detects E. coli O157:H7 reliably at 50-100 cells/mL with a 3 mL sample.

Animals↗

Use of piezoelectric-excited millimeter-sized cantilever sensors to measure albumin interaction with self-assembled monolayers of alkanethiols having different functional headgroups.

In this paper, we describe a new modality of measuring human serum albumin (HSA) adsorption continuously on CH3-, COOH-, and OH-terminated self-assembled monolayers (SAMs) of C11-alkanethiols and the direct quantification of the adsorbed amount. A gold-coated piezoelectric-excited millimeter-sized cantilever (PEMC) sensor of 6-mm2 sensing area was fabricated, where resonant frequency decreases upon mass increase. The resonant frequency in air of the detection peak was 45.5 +/- 0.01 kHz. SAMs of C11-thiols (in absolute ethanol) with different end groups was prepared on the PEMC sensor and then exposed to buffer solution containing HSA at 10 microg/mL. The resonant frequency decreased exponentially and reached a steady-state value within 30 min. The decrease in resonant frequency indicates that the mass of the sensor increased due to HSA adsorption onto the SAM layer. The frequency change obtained for the HSA adsorption on CH3-, COOH-, and OH-terminated SAM were 520.8 +/- 8.6 (n = 3), 290.4 +/- 6.1 (n = 2), and 210.6 +/- 8.1 Hz (n = 3), respectively. These results confirm prior conclusions that albumin adsorption decreased in the order, CH(3) > COOH > OH. Observed binding rate constants were 0.163 +/- 0.003, 0.248 +/- 0.006, and 0.381 +/- 0.001 min(-1), for methyl, carboxylic, and hydroxyl end groups, respectively. The significance of the results reported here is that both the formation of self-assembled monolayers and adsorption of serum protein onto the formed layer can be measured continuously, and quantification of the adsorbed amount can be determined directly.

Adsorption↗

Detection of Bacillus anthracis spores and a model protein using PEMC sensors in a flow cell at 1 mL/min.

Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors of 4mm(2) sensing area were immobilized with antibody specific to Bacillus anthracis (anti-BA) spores or bovine serum albumin (anti-BSA). Detection of pathogen (Bacillus anthracis (BA) at 300 spores/mL) and BSA (1 mg/mL) were investigated under both stagnant and flow conditions. Two flow cell designs were evaluated by characterizing flow-induced resonant frequency shifts. One of the flow cells labeled SFC-2 (hold-up volume of 0.3 mL), showed small fluctuations (+/-20 Hz) around a common resonant frequency response of 217 Hz in the flow rate range of 1-17 mL/min. The total resonant frequency change obtained for the binding of 300 spores/mL in 1h was 90+/-5 Hz (n=2), and 162+/-10 Hz (n=2) under stagnant and flow conditions, respectively. Binding of antibodies, anti-BA and anti-BSA, were more rapid under flow than under stagnant conditions. The sensor was repeatedly exposed to BSA with an intermediate release step. The first and second responses to BSA were nearly identical. The total resonant frequency response to BSA was 388+/-10 (n=2) Hz under flow conditions. Kinetic analysis is carried out to quantify the effect of flow rate on antibody immobilization and the two types of detection experiments.

Animals↗

PEMC sensor's mass change sensitivity is 20 pg/Hz under liquid immersion.

To enhance the mass change sensitivity of the resonating piezoelectric-excited millimeter-sized cantilever (PEMC) sensors, we reduced its length and eliminated one layer of its composite structure. As a result the mass sensitivity of the second flexural mode increased by two orders of magnitude (from 10(-9) to 10(-11)g/Hz) and the resonant frequency increased by more than 5 kHz. We demonstrate the effects of modification by detecting a model pathogen Group A Streptococcus (GAS) at 700 cells/mL. The resonant frequency change of the second mode at concentrations of 700, 7 x 10(3), 7 x 10(5), 7 x 10(6), 7 x 10(7), and 7 x 10(9)cells/mL resulted in, respectively, 3.1+/-0.5, 11.6+/-1, 15.7+/-1, 25.7+/-0.15, 28.5+/-2, and 40.5+/-3 ng (n=3 for all) of pathogen attachment. A kinetic model for the binding is proposed and verified. The observed binding rate constant was found to be in the range of 0.051-0.166 min(-1). The significance of the results we report is that the modified PEMC sensors have high mass sensitivity that pathogens can be detected at very low concentration under liquid immersion conditions.

Air↗

Measuring bacterial growth by tapered fiber and changes in evanescent field.

Single mode continuous tapered fibers were fabricated with waist diameters of 6-8 microm and of 11 mm waist lengths. The tapered surface was coated with poly-l-lysine and Escherichia coli (E. coli) (JM 101) expressing green fluorescent protein was immobilized. Growth of this culture at 22 and 32 degrees C was monitored by 480 nm light transmission through the tapered fiber. Change in transmission is a measure of change in absorption of the evanescent field. The transmission decreased exponentially with cell growth on the tapered surface. Growth rate was determined and compared favorably with cells grown on the same medium in multiwell plates. Significance of the results is that a tapered fiber sensor can be used effectively for rapid assessment to determine the presence of bacteria by growth.

Biosensing Techniques↗

Effects of geometry on transmission and sensing potential of tapered fiber sensors.

Geometry of tapered fiber sensors critically affects the response of an evanescent field sensor to cell suspensions. Single-mode fibers (nominally at 1300 nm) were tapered to symmetric or asymmetric tapers with diameters in the range of 3-20 microm, and overall lengths of 1-7 mm. Their transmission characteristics in air, water and in the presence of Escherichia coli (JM101 strain) at concentrations of 100, 1000, 7000 and 7 million cells/mL were measured in the 400-800 nm range and gave rich spectral data that lead to the following conclusions. (1) No change in transmission was observed due to E. coli with tapers that showed no relative change in transmission in water compared to air. (2) Tapers that exhibited a significant difference in transmission in water compared to air gave weak response to the presence of the E. coli. Of these, tapers with low waist diameters (6 microm) showed sensitivity to E. coli at 7000 cells/mL and higher concentration. (3) Tapers that showed modest difference in water transmission compared to air, and those that had small waist diameters gave excellent response to E. coli at 100-7000 cells/mL. In addition, mathematical modeling showed that: (1) at low wavelength (470 nm) and small waist diameter (6 microm), transmission with water in the waist region is higher than in air. (2) Small changes in waist diameter (approximately 0.05 microm) can cause larger changes in transmission at 470 nm than at 550 nm at waist diameter of 6 microm. (3) For the same overall geometry, a 5.5 microm diameter taper showed larger refractive index sensitivity compared to a 6.25 microm taper at 470 nm.

Biosensing Techniques↗

Detection of pathogen Escherichia coli O157:H7 AT 70 cells/mL using antibody-immobilized biconical tapered fiber sensors.

Optical fibers (core diameter 8 microm, cladding diameter 125 microm) was tapered to a waist diameter in the range of 8-12 microm, and then a monoclonal antibody to the pathogen, Escherichia coli O157:H7 was covalently bonded to the surface of the tapered region. Using 470 nm light, the taper was exposed to various concentrations (7 x 10(7), 7 x 10(5), 7 x 10(3), and 70 cells/mL) of the pathogen, and the sensor showed changes in transmitted light as the antigen attached to the antibody on the taper surface. The response was equal and opposite when the pathogen was released from the surface using a low pH buffer. The magnitude of the change was inversely proportional to the concentration of the pathogen. The sensor showed good sensitivity at as low a concentration as 70 cells/mL. The antibody-immobilized taper sensor was also exposed to a mixture of the pathogen and a non-pathogenic variant (JM101) at 0%, 50% and 70% by concentration. The sensor showed good selectivity to the pathogenic antigen. A first order attachment kinetic model is proposed to quantify the rate of attachment of pathogen to the sensor surface. The kinetic rate constant (k) of E. coli O157:H7 to the fiber was found to vary in the range of (2.5-6.1) x 10(-9) min(-1) (cells/mL)(-1).

Antibodies, Bacterial↗

Monitoring of the self-assembled monolayer of 1-hexadecanethiol on a gold surface at nanomolar concentration using a piezo-excited millimeter-sized cantilever sensor.

In this paper, we describe a new method of measuring alkanethiol monolayer formation on a gold surface. A gold-coated millimeter-sized rectangular-shaped lead zirconate titanate (PZT) cantilever of dimensions 3.5 x 2 x 0.05 mm, previously shown to detect a picogram level of mass change, was used to measure the adsorption kinetics of 1-hexadecanethiol in ethanol over six orders of concentration range (1 nM to 10 mM) in real time. The flexural mode of cantilever vibration, 45.5 +/- 0.01 kHz, was monitored during the self-assembly. The total resonant frequency change obtained for the 1 nM, 10 nM, 100 nM, 1 microM, 4 mM, 8 mM, and 10 mM thiol concentrations were 116 +/- 2 (n = 2), 225 (n = 1), 270 +/- 10 (n = 2), 440 +/- 10 (n = 2), 900 +/- 10 (n = 2), 900 +/- 10 (n = 2), and 900 +/- 10 (n = 2) Hz, respectively. These results compare favorably to literature results in that the rate of the monolayer formation is concentration-dependent and the exponential change during adsorption follows the reversible first-order Langmuir kinetic model. The rate constants of adsorption and desorption were 0.061 M(-1) s(-1) and 3.61 x 10(-4) s(-1), respectively. The significance of the results is that millimeter-sized PZT cantilevers can be used in real-time for characterizing self-assembly of monolayer formation at nanomolar concentration levels. In addition, at 1 nM, the adsorption was found not to be diffusion limited.

Adsorption↗

Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors detect Bacillus anthracis at 300 spores/mL.

Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors consisting of a piezoelectric and a borosilicate glass layer with a sensing area of 2.48 mm2 were fabricated. Antibody specific to Bacillus anthracis (BA, Sterne strain 7702) spores was immobilized on PEMC sensors, and exposed to spores (300 to 3x10(6) spores/mL). The resonant frequency decreased at a rate proportional to the spore concentration and reached a steady state frequency change of 5+/-5 Hz (n=3), 92+/-7 Hz (n=3), 500+/-10 Hz (n=3), 1030+/-10 Hz (n=2), and 2696+/-6 Hz (n=2) corresponding to 0, 3x10(2), 3x10(3), 3x10(4), and 3x10(6) spores/mL, respectively. The reduction in resonant frequency is proportional to the change in cantilever mass, and thus the observed changes are due to the attachment of spores on the sensor surface. Selectivity of the antibody-functionalized sensor was determined with samples of BA (3x10(6)/mL) mixed with Bacillus thuringiensis (BT; 1.5x10(9)/mL) in various volume ratios that yielded BA:BT ratios of 1:0, 1:125, 1:250, 1:500 and 0:1. The corresponding resonance frequency decreases were, respectively, 2345, 1980, 1310, 704 and 10 Hz. Sample containing 100% BT spores (1.5x10(9)/mL and no BA) gave a steady state frequency decrease of 10 Hz, which is within noise level of the sensor, indicating excellent selectivity. The observed binding rate constant for the pure BA and BT-containing samples ranged from 0.105 to 0.043 min-1 in the spore concentration range 300 to 3x10(6)/mL. These results show that detection of B. anthracis spore at a very low concentration (300 spores/mL) and with high selectivity in presence of another Bacillus spore (BT) can be accomplished using piezoelectric-excited millimeter-sized cantilever sensors.

Bacillus anthracis↗

Protein response of insect cells to bioreactor environmental stresses.

Protein expression of Spodoptera frugiperda (Sf9) insect cells was characterized upon exposure to environmental stresses typically present in bioreactors including heat shock, oxygen deprivation, shear stress, change of pH, and salinity or ethanol shock. This study fills the void in knowledge as to how bioreactor hydrodynamics, anoxia, small changes in pH as well as salinity alterations due to pH control or exposure to ethanol used in asepsis treatments affect protein expression in Sf9 cells. Heat shock at 43 degrees C induced proteins at 83 kDa, 68-78 kDa and six small heat shock proteins (hsps) at 23-15.5 kDa. Anaerobic conditions in CO2 atmosphere reduced significantly the normal protein synthesis and induced a small subset of heat shock proteins at 70 kDa. Oxygen deprivation in nitrogen atmosphere transiently induces the 70 kDa proteins and had minor effects on the normal protein synthesis. Exposure to increased salinity or ethanol concentration failed to trigger the stress response, but may extensively inhibit the induction of normal proteins even though there was a negligible change in cell viability. Shear stress that had a major reducing effect on cell viability did not change the protein synthesis profile of Sf9 cells. Both long and short term exposures to small pH changes had negligible effects on protein synthesis.

Animals↗

Detection and quantification of proteins using self-excited PZT-glass millimeter-sized cantilever.

A composite self-excited PZT-glass cantilever (4mm in length and 2mm wide) was fabricated and used to measure the binding and unbinding of model proteins. A key feature of the cantilever is that its resonant frequency is dependent on its mass. The fabricated cantilever has mass change sensitivity in liquid of 7.2 x 10(-11)g/Hz. Resonant frequency change was measured as protein reacted or bound with the sensing glass cantilever surface. Protein concentrations, 0.1 and 1.0mg/mL, which resulted in nanogram mass change were successfully detected. The mass change sensitivity gave a total mass change of 54+/-0.45 ng for the binding of anti-rabbit IgG (biotin conjugated) to rabbit IgG immobilized cantilever and the subsequent binding of captavidin. The unbinding of anti-rabbit IgG and captavidin gave a total mass change of 54+/-1.70 ng. Fluorescence based assays showed the combined mass of both proteins in the released samples was 54+/-2.24 ng. The binding kinetics of the model proteins is modeled as first order. The initial binding rate constant of anti-rabbit IgG to rabbit IgG was 1.36+/-0.02(min(mg/mL))(-1). The initial binding rate constant of captavidin to biotinylated anti-rabbit IgG was (2.57 x 10(-1))+/-0.003(min(mg/mL))(-1). The significance of the results we report here is that millimeter-sized PZT-actuated glass cantilevers have the sensitivity to measure in real-time protein-protein binding, and the binding rate constant.

Electrochemistry↗

Escherichia coli O157:H7 detection limit of millimeter-sized PZT cantilever sensors is 700 cells/mL.

A composite self-excited millimeter-sized lead zirconate titanate (PZT) glass cantilever (2 mm x 1.8 mm; sensing area of 6 mm2) was fabricated for the detection of Escherichia coli (E. coli) O157:H7. The fundamental and second mode resonance in air was 10.95 +/- 0.05 kHz and 43.45 +/- 0.05 kHz, respectively. Affinity purified monoclonal antibody (anti-E. coli O157:H7) specific to the pathogen E. coli O157:H7 was immobilized at the cantilever glass tip, and then immersed in liquid containing the pathogen (70 to 7 x 10(7) cells/mL). The resonant frequency showed a reduction and reached a steady state shift of 0 +/- 5, 46 +/- 5, 260 +/- 5, and 1010 +/- 5 Hz corresponding to 0, 700, 7000, and 7 x 10(7) cells/mL. From the experiments conducted, the detection limit of the sensor was 700 cells/mL.

Algorithms↗

Detection of pathogen Escherichia coli O157:H7 using self-excited PZT-glass microcantilevers.

Composite self-excited PZT-glass cantilevers (5 and 3 mm in length, 1.8 and 2.0 mm wide) were fabricated and their resonance characteristics were determined in air and at 1 mm liquid immersion. In air, resonance occurred at 65.8 and 63.4 kHz for the two cantilevers used in this paper. Monoclonal antibody (MAb) specific to the pathogen Escherichia coli (E. coli) O157:H7 was immobilized at the cantilever glass tip, and then exposed to pathogen in the concentration range of 7x10(2) to 7x10(7)bacteria/mL. Resonance of the second mode decreased due to pathogen attachment in accordance with a proposed kinetic model. The specific attachment rate constant was found to be 3x10(-9) to 5x10(-9) min-1 (cell/mL)-1. Exposure to a mixed population containing both a pathogenic and non-pathogenic strain showed that the antibody-immobilized cantilever is highly selective, thus demonstrating its usefulness for detecting water-borne pathogens.

Antibodies↗

A rapid method for measuring intracellular pH using BCECF-AM.

A rapid intracellular pH (pH(i)) measurement method based on initial rate of increase of fluorescence ratio of 2',7'-bis(2-carboxyethyl)-5,6-carboxyfluorescein upon dye addition to a cell suspension in growth medium is reported. A dye transport model that describes dye concentration and fluorescence values in intracellular and extracellular spaces provides the mathematical basis for the approach. Experimental results of ammonium chloride challenge response of the two suspension cells, Spodoptera frugiperda and Chinese hamster ovary (CHO) cells, successfully compared with results obtained using traditional perfusion method. Since the cell suspension does not require any preparation, measurement of pH(i) can be completed in about 1 min minimizing any potential errors due to dye leakage.

Alkaline Phosphatase↗

Decolorization of the dye, Reactive Blue 19, using ozonation, ultrasound, and ultrasound-enhanced ozonation.

Reactive dyes constitute a significant portion of colorants used in industries ranging from the textile industry to the paper industry. In most cases, the effluent streams from textile plants are highly colored, and treatment methods for dye decolorization such as chemical oxidation need to be explored. The oxidation processes investigated in this study are those of ozonation, ultrasound, and ultrasound-enhanced ozonation. The oxidation of an anthraquinone dye was studied under conditions of varying ultrasonic power, dye concentration, ozone concentration, pH, and temperature. Laboratory experiments were performed using a semibatch reactor by ozonating dye samples with and without ultrasound. Under conditions of constant ultrasonic radiation and continuous gas application, decolorization rates have been enhanced by ultrasound. The apparent first-order rate constants increased between 35 and 204% for the ultrasonic power inputs between 40 W/L and 120 W/L compared with ozonation alone. The effects of ultrasonic power input on the gas-liquid mass-transfer coefficient were also investigated and the results indicate that an increase in ultrasonic power input increases the mass-transfer coefficient. The mass-transfer coefficient increased between 89 and 93% for ozone inlet concentrations between 5.4 and 9.4 mg/L at an ultrasonic power of 120 W/L compared with ozonation alone. The reactions of the dye with ultrasound-enhanced ozone occurred through the hydroxyl radical pathway.

Coloring Agents↗