PubMed Health⌕ Search

Biomedical subjects

Raleigh F Johnson

Publications and source records attributed to Raleigh F Johnson.

2 recordsLinked to original sources

Evaluation of the internal auditory canal with virtual endoscopy.

OBJECTIVE: Three-dimensional imaging can improve the understanding and comprehension of complex anatomy. Recent advances in software development allow the construction of a virtual endoscopic view of anatomic structures. This report applies virtual endoscopic capabilities to imaging of the internal auditory canal. STUDY DESIGN, SETTING, AND PATIENTS: We conducted a retrospective case review at a tertiary referral center of patients with abnormal internal auditory canal anatomy on computed tomography. INTERVENTIONS: Computed tomography images were obtained using conventional clinical algorithms involving multiple, 1-mm-thick slices through the temporal bone. Three-dimensional reconstructions were made using General Electric Advantage Windows Navigator software. The virtual endoscopic image-processing algorithm used selected image intensity threshold levels to visualize internal auditory canal anatomy from an endoscopic perspective. RESULTS: Eleven cases of abnormalities of the internal auditory canal were retrospectively identified. Clinical applications using the virtual endoscopic images are presented. The virtual endoscopic images supported prior clinical decision making in 6 of the 11 cases evaluated. CONCLUSION: This technique shows promise for the diagnosis, surgical planning, and teaching of temporal bone anatomy. Usefulness is dependent on acquisition parameters and clinical indications for examination.

Algorithms↗

3D CT imaging method for measuring temporal bone aeration.

OBJECTIVE: 3D volume reconstruction of CT images can be used to measure temporal bone aeration. This study evaluates the technique with respect to reproducibility and acquisition parameters. MATERIAL AND METHODS: Helical CT images acquired from patients with radiographically normal temporal bones using standard clinical protocols were retrospectively analyzed. 3D image reconstruction was performed to measure the volume of air within the temporal bone. The appropriate threshold values for air were determined from reconstruction of a phantom with a known air volume imaged using the same clinical protocols. The appropriate air threshold values were applied to the clinical material. RESULTS: Air volume was measured according to an acquisition algorithm. The average volume in the temporal bone CT group was 5.56 ml, compared to 5.19 ml in the head CT group (p = 0.59). The correlation coefficient between examiners was > 0.92. There was a wide range of aeration volumes among individual ears (0.76-18.84 ml); however, paired temporal bones differed by an average of just 1.11 ml. CONCLUSIONS: The method of volume measurement from 3D reconstruction reported here is widely available, easy to perform and produces consistent results among examiners. Application of the technique to archival CT data is possible using corrections for air segmentation thresholds according to acquisition parameters.

Adult↗