PubMed Health⌕ Search

Biomedical subjects

Ralf Heilker

Publications and source records attributed to Ralf Heilker.

12 recordsLinked to original sources

Novel fluorescent proteins for high-content screening.

The development of fast microscopic imaging devices has enabled the application of automated fluorescence microscopy to pharmaceutical high-throughput drug-discovery assays, referred to as high-content screening (HCS). Initially, green fluorescent protein and its derivatives from Aequorea Victoria, and later anthozoan fluorescent proteins (FPs) have become potent tools as live-cell markers in HCS assays. We illustrate the broad applicability of classic and novel FPs to drug-discovery assays, giving example applications of the use of FPs in multiplexed imaging as fluorescent timers, photosensitizers and pulse-chase labels, and for robotically integrated compound testing.

Animals↗

G protein-coupled receptor internalization assays in the high-content screening format.

High-content screening (HCS), a combination of fluorescence microscopic imaging and automated image analysis, has become a frequently applied tool to study test compound effects in cellular disease-modeling systems. This chapter describes the measurement of G protein-coupled receptor (GPCR) internalization in the HCS format using a high-throughput, confocal cellular imaging device. GPCRs are the most successful group of therapeutic targets on the pharmaceutical market. Accordingly, the search for compounds that interfere with GPCR function in a specific and selective way is a major focus of the pharmaceutical industry today. This chapter describes methods for the ligand-induced internalization of GPCRs labeled previously with either a fluorophore-conjugated ligand or an antibody directed against an N-terminal tag of the GPCR. Both labeling techniques produce robust assay formats. Complementary to other functional GPCR drug discovery assays, internalization assays enable a pharmacological analysis of test compounds. We conclude that GPCR internalization assays represent a valuable medium/high-throughput screening format to determine the cellular activity of GPCR ligands.

Animals↗

Comparison of G-protein coupled receptor desensitization-related beta-arrestin redistribution using confocal and non-confocal imaging.

High Content Screening (HCS), a combination of fluorescence microscopic imaging and automated image analysis, has become a frequently applied tool to study test compound effects in cellular disease-modelling systems. In this work, we compared a confocal and a non-confocal cellular HCS system, the IN Cell Analyzers(1) 3,000 and 1,000, respectively. As a cellular model system we used the Transfluor technology in the 384-well microtiter plate (MTP) format. The Transfluor HCS assay for G-protein coupled receptor (GPCR) activation is based on the recruitment of a green fluorescent protein-labelled arrestin (ArrGFP) from the cytosol to the plasma membrane. We investigated two GPCRs, the wild-type (wt) beta2 adrenergic receptor (beta2AR) and the beta2AR-enhanced (E), a C-terminally mutated receptor with a higher affinity to arrestin. Upon agonist stimulation, the beta2AR-wt induced the redistribution of ArrGFP to coated pits, the beta2AR-E maintained the interaction with ArrGFP down to the formation of endocytic vesicles. Our findings reveal that the assay is feasible on both instruments, with sufficiently robust Z' statistics. Improved Z' statistics, though, are achieved with the confocal system, particularly in case of weak signals. Moreover, throughput is dramatically higher for the IN Cell Analyzer 3,000. We conclude that, depending on the needs for throughput and assay biology, either instrument may fulfil a successful role in the drug discovery process. Confocal optics, however, provide a better basis for the detection of smaller subcellular structures with lower fluorescence intensity.

Adrenergic beta-2 Receptor Agonists↗

Automated high content screening for phosphoinositide 3 kinase inhibition using an AKT 1 redistribution assay.

High Content Screening (HCS), a combination of fluorescence microscopic imaging and automated image analysis, has become a frequently applied tool to study test compound effects in cellular disease-modelling systems. In this work, we established a medium to high throughput HCS assay in the 384-well format to measure cellular type I phosphoinositide 3 kinase (PI3K) activity. Type I PI3K is involved in several intracellular pathways such as cell survival, growth and differentiation as well as immunological responses. As a cellular model system we used Chinese Hamster Ovary (CHO) cells that had been stably transfected with human insulin receptor (hIR) and an AKT1-enhanced green fluorescent protein (EGFP) fusion construct. Upon stimulation of the hIR with insulin-like growth factor-1 (IGF-1), PI3K was activated to phosphorylate phosphatidylinositol (PtdIns)-4,5-bisphosphate at the 3-position, resulting in the recruitment of AKT1-EGFP to the plasma membrane. The AKT1-EGFP redistribution assay was robust and displayed little day-to-day variability, the quantification of the fluorescence intensity associated with plasma membrane spots delivered good Z' statistics. A novel format of compound dose-response testing was employed using serial dilutions of test compounds across consecutive microtiter plates (MTPs). The dose response testing of a PI3K inhibitor series provided reproducible IC50 values. The profiling of the redistribution assay with isoform-selective inhibitors indicates that PI3Kalpha is the main isoform activated in the CHO host cells after IGF-1 stimulation. Toxic compound side effects could be determined using automated image analysis. We conclude that the AKT1-EGFP redistribution assay represents a solid medium/high throughput screening (MTS/HTS) format to determine the cellular activity of PI3K inhibitors under conditions of growth factor stimulation.

Animals↗

High-throughput screening of interactions between G protein-coupled receptors and ligands using confocal optics microscopy.

Interactions of extracellular ligands with proteins in the cellular plasma membrane are the starting point for various intracellular signaling cascades. In the pharmaceutical industry, particular attention has been paid to G protein- coupled receptors (GPCRs), which are involved in various disease processes. In so-called high-throughput screening (HTS) campaigns, large medicinal chemistry compound libraries were searched for bioactive molecules that would either induce or inhibit the activity of a specific disease-relevant GPCR. In the respective drug discovery assays, the test compound typically competes with the physiological ligand for a binding site on the receptor. The transmembrane receptor is prepared in the form of membrane fragments or, as described here, in so-called virus-like particles (VLiPs). As hundreds of thousands of test compounds must be analyzed, there is a strict need for low volume binding assays to save the expensive bioreagents, and to reduce the consumption of the test compounds. In this chapter, we describe the application of confocal optics microscopy to measure GPCR ligand interactions in low microliter assay volumes.

Animals↗

Confocal fluorescence microscopy for high-throughput screening of G-protein coupled receptors.

In the pharmaceutical industry, G-protein coupled receptors (GPCRs) are the most successful group of therapeutic targets. Finding compounds that interfere with the ligand-GPCR interaction in a specific and selective way is a major focus of pharmaceutical research today. As compound libraries of large pharmaceutical companies have increased to hundreds of thousands of test compounds, there is a growing need for miniaturization of drug discovery assays to save bioreagents and to reduce the consumption of test compounds. Due to its high sensitivity combined with a femtoliter-sized measurement volume, confocal fluorescence microscopy enables designs for GPCR binding assays with tiny sample volumes. The GPCRs are prepared in the form of plasma membrane fragments from GPCR-overexpressing cells or may be integrated into virus-like particles (VLiPs). One technique to extract binding data from confocal fluorescence experiments is the so-called fluorescence intensity distribution analysis (FIDA). In this review article, we describe the applicability of FIDA to GPCR-focussed high-throughput screening (HTS) and compare FIDA to two other GPCR-adaptable drug discovery techniques for ligand binding studies, the scintillation proximity assay (SPA) and macroscopic fluorescence polarization (FP) measurements. FIDA measures the absolute concentrations of both GPCR-bound and unbound ligand, thereby providing an internal control to the drug screening data. FIDA is amenable to work with relatively low amounts of GPCRs so that the assay may be carried out with biomembranes of a low GPCR density. Moreover, the fluorescence intensity readout of the FIDA technique may be combined with other confocal fluorescence readouts such as fluorescence anisotropy or lifetime. The combination of a low sample volume with an information-rich measurement means that confocal fluorescence spectroscopy can bring substantial benefits as a bioassay platform to pharmaceutical GPCR-directed research.

Animals↗

Endothelin receptor in virus-like particles: ligand binding observed by fluorescence fluctuation spectroscopy.

The functional analysis of transmembrane receptor proteins is frequently hampered by the difficulty to produce sufficiently homogeneous receptor preparations that preserve the physiological biomembrane integration of the receptor protein. To improve the receptor protein density in the lipid bilayer and to maintain the physiological lipid-protein environment, a novel method has been established that enables the selective integration of transmembrane receptors into a virus-like particle (VLiP). Here we have studied the binding of tetramethylrhodamine-labeled endothelin-1 (TMR-ET-1) to VLiP-integrated endothelin A receptor (ET(A)R) by fluorescence fluctuation spectroscopy. The concentration of TMR-ET-1 was determined by fluorescence correlation spectroscopy (FCS). These measurements also confirmed that the free ligand is monomeric in solution in our experiments. Fluorescence intensity distribution analysis (FIDA) was used to quantify the fraction of ligands bound to ET(A)Rs in the VLiPs. For the interaction between ET-1 and VLiP-integrated ET(A)Rs, K(D) values of 0.5 nM and 0.3 nM were determined from ligand and receptor titration experiments, respectively. For comparison, a FIDA analysis was also carried out with ET(A)Rs in membrane fragments derived from an ET(A)R-overexpressing mammalian cell line, which yielded a similar K(D) of 0.2 nM. In addition, we examined the binding competition of a set of reference compounds to VLiP-ET(A)Rs in the presence of ET-1 and obtained K(i) values similar to those reported in the literature. Our results demonstrate that integration into VLiPs does not change the binding properties of the ET(A)Rs. FIDA analysis of VLiP-integrated receptors shows great promise for highly miniaturized and fast compound testing in the pharmaceutical industry.

Cell Line↗

Peptide protein binding assay using ImageFlashPlates or Imaging Beads.

Imaging devices used for the measurement of radioligand-receptor binding assays are typically based on charge-coupled device (CCD) cameras, which are more sensitive for red-shifted scintillation. In the past, red-shifted scintillants had only been integrated into microspheres, referred to as scintillation proximity assay (SPA) Imaging Beads. More recently, ImageFlashPlates have been developed that emit light at 615 nm when exposed to beta-radiation. In this article, we report the establishment of peptide-protein binding assays using either streptavidin-coated ImageFlashPlates or Imaging Beads in a low volume 384-well format. In these assays, we employed a biotinylated peptide X and a [33P]-phosphorylated protein Y as the binding partner. The FlashPlates required a washing step, the bead-filled microtiter plates (MTPs) needed a centrifugation step for optimal performance in the scintillation measurements. Both the peptide X-loaded FlashPlates and the beads displayed saturable binding of [33P]-phosphorylated protein Y with a similar scintillation efficiency. A KD value of about 30 nmol/l was measured using the bead-based assay. Due to the washing step in the FlashPlate experiment, approximately two-thirds of the [33P]-phosphorylated protein Y were withdrawn from equilibrium binding. This resulted in correspondingly lower scintillation signals for the FlashPlate experiment. For this reason, the FlashPlate produced a Z' value of 0.64 that was lower than the Z' value of 0.87 for the beads. Using a reference inhibitor in a competition assay produced similar IC50 values for the bead-based assay as for the FlashPlate. Depending on the local automation environment either the centrifugation step for the beads or the washing step for the FlashPlates may be considered more or less of a challenge. Low volume 384-well high-throughput screening (HTS) applicable assay formats are achievable using either the ImageFlashPlates or the Imaging Beads.

Biotin↗

Time-resolved fluorescence measurements using microlens array and area imaging devices.

Time-resolved fluorescence (TRF) assay formats are frequently used technologies in high-throughput screening. In this article, we have characterised the novel Plate::Vision(2) 96-microlens array reader (Carl Zeiss Jena GmbH, Germany) and compared it to the novel LEADseeker Generation IV multimodality imaging system (LEADseeker Gen IV; Amersham Biosciences UK Ltd., UK) for applications in the TRF mode. In europium measurements using the TRF mode, the Plate::Vision displayed a limit of detection for europium of approximately 3 pM, which was comparable to two established TRF readers, the Discovery and the Victor V (both PerkinElmer Life Sciences Inc., USA). The LEADseeker's limit of detection only extended down to europium concentrations of approximately 10 pM in these experiments. For TRF resonance energy transfer (TR-FRET) experiments, a europium-biotin (Eu-biotin) conjugate was titrated with a streptavidin-allophycocyanin (SA-APC) conjugate. The Plate::Vision produced Z' values larger than 0.5 for the acceptor fluorophor emission with concentrations of Eu-biotin as low as 3 nM combined with 175 pM SA-APC. To achieve Z' values of at least 0.5 with the LEADseeker, concentrations of 10 nM Eu-biotin combined with SA-APC of at least 0.8 nM were required. In a drug screening application using TR-FRET, the energy transfer from a europium-labelled protein X (Eu-protein X) to a complex of biotinylated peptide Y with SA-APC was measured. Using the Plate::Vision, a Z' factor larger than 0.5 for the acceptor fluorophor emission was only obtained for a Eu-protein X concentration of at least 10 nM in combination with biotinylated peptide Y/SA-APC at saturating concentrations. Both the Plate::Vision and the LEADseeker show good quality results for applications in the TRF mode and enable an increased throughput based on their shortened measurement time in comparison to classic photomultiplier tube-based readers.

Biological Assay↗

Confocal optics microscopy for biochemical and cellular high-throughput screening.

In recent years, both academia and pharmaceutical industry have produced significant advances in confocal detection and spectroscopy by laser-induced fluorescence. Confocal fluorescence studies provide information on identity, size, diffusion coefficient and concentration of the fluorescently labeled entity. This enables the establishment of sophisticated biochemical drug screening assays using the multitude of fluorescence parameters that can be observed (e.g. molecular brightness, fluorescence lifetime, anisotropy, resonance energy transfer). In cellular screening assays, confocality introduces spatial resolution in the vertical direction and reduces background fluorescence from outside the focal plane. Confocal HTS systems focusing on femtoliter-sized observation volumes allow for assay volumes far beyond current limits.

Microscopy, Confocal↗

Automated high throughput screening for serine kinase inhibitors using a LEADseeker scintillation proximity assay in the 1536-well format.

High-throughput screening in the 1536-well format has been largely restricted to solution-based and cell-based screens. In this article, we show the feasibility of a completely automated, robust scintillation proximity assay in the 1536-well format that is suitable to identify inhibitors for a serine/threonine kinase from a compound library. The introduction of [(33)P]phosphate into a biotinylated peptide substrate mirrors the activity of the kinase. The peptide is immobilized on streptavidin-coated LEADseeker imaging beads and [(33)P]phosphate incorporation is detected with the LEADseeker imaging system of Amersham Pharmacia Biotech. To improve the liquid handling procedures for imaging bead suspensions in the low microliter range, we developed a novel trough with an integrated stirring function. A comparison of the 1536-well assay to a 384-well assay revealed a comparable assay quality with Z' factors of about 0.7 for the 384-well format and 0.6 for the 1536-well format. In an automated screen of a random compound collection, 94.4% of the inhibitory compounds could be identified with both assay formats. Dose-response curves were performed for a selection of identified kinase inhibitors and revealed similar IC(50) values for both assay formats.

Automation↗

Photoconvertible fluorescent protein EosFP: biophysical properties and cell biology applications.

EosFP is a fluorescent protein from the coral Lobophyllia hemprichii that changes its fluorescence emission from green to red upon irradiation with near-UV light. Here we present the spectroscopic properties of wild-type EosFP and a variety of monomeric and dimeric mutants and provide a structural interpretation of its oligomerization and photoconversion, which is based on X-ray structure analysis of the green and red species that we reported recently. Because functional expression of the monomeric EosFP variant is limited to temperatures of 30 degrees C, we have developed a tandem dimer. This construct, in which two EosFP subunits are connected by a flexible 12 amino acid linker, expresses well after fusion with the androgen and endothelin A receptors at 37 degrees C. A variety of applications in cellular imaging, developmental biology and automated high-content screening applications are presented, which demonstrate that EosFP is a powerful tool for in vivo monitoring of cellular processes.

Amino Acids↗