The effect of a carbon-fiber couch on the depth-dose curves and transmission properties for megavoltage photon beams.

PURPOSE: To investigate the attenuation of a carbon-fiber tabletop and a combiboard, alongside with the depth-dose profile in a solid-water phantom. MATERIAL AND METHODS: Depth-dose measurements were performed with a Roos chamber for 6- and 10-MV beams for a typical field size (15 cm x 15 cm, SSD [source-surface distance] 100 cm). A rigid-stem ionization chamber was used to measure transmission factors. RESULTS: Transmission factors varied between 93.6% and 97.3% for the 6-MV beam, and 95.1% and 97.7% for the 10-MV photon beam. The lowest transmission factors were observed for the oblique gantry angle of 150 degrees with the table-combiboard combination. The surface dose normalized to a depth of 5 cm increased from 59.4% (without table, 0 degrees gantry), to 108.6% (tabletop present, 180 degrees gantry), and further to 120% (table-combiboard combination) for 6-MV photon beam. For 10 MV, the increase was from 39.6% (without table), to 88.9% (with table), and to 105.6% (table-combiboard combination). For the 150 degrees angle (tablecombiboard combination), the dose increased from 59.4% to 120% (6 MV) and from 39% to 108.1% (10 MV). CONCLUSION: Transmission factors for tabletops and accessories directly interfering with the treatment beam should be measured and implemented into the treatment-planning process. The increased surface dose to the skin should be considered.

Beds↗

The dose-area product, a new parameter for the dosimetry of narrow photon beams.

In the dosimetry of narrow photon fields with side lengths of the order of 1 cm, the traditional parametrisation via the absolute dose on the beam axis and the relative lateral dose distribution has to deal with the difficulty to find sufficiently small detectors and to adjust them accurately on the narrow-beam axis. This can be avoided by reconsidering the parametrisation, using as normalization factor the surface integral of the dose in the plane perpendicular to the beam axis, abbreviated as the "dose-area product" (DAP). We investigated and confirmed the ability of a large-area parallel-plate ionisation chamber, with a sensitive volume shaped as a flat cylinder of 81.6 mm diameter and 2 mm thickness, to perform the integration over the full lateral dose profile of narrow photon beams with side lengths up to 5 cm. The lateral adjustment of this large-area detector relative to a narrow photon beam is not critical. The large-area ionisation chamber was calibrated in terms of the DAP by reference to a 0.3 cm3 ionisation chamber. A field-size dependent "modified output factor" was defined as the ratio of the DAP measured at 5 cm phantom depth for 100 cm SSD, and the monitor reading. A prominent phenomenon of narrow photon fields is the field-size and source-distance independence of the relative axial profile of the DAP as function of the thickness of a pre-absorber or of the depth in a phantom. For narrow-beam treatment planning in IMRT, the DAP is combined with the energy- and field size-dependent relative lateral dose distribution which is represented, for example, by a Gaussian convolution kernel. Another useful feature of the DAP is the possibility of its direct control during patient irradiation by means of an on-line monitor with spatial resolution, arranged in the accessory holder.

Calibration↗

Two-dimensional ionization chamber arrays for IMRT plan verification.

In this paper we describe a concept for dosimetric treatment plan verification using two-dimensional ionization chamber arrays. Two different versions of the 2D-ARRAY (PTW-Freiburg, Germany) will be presented, a matrix of 16 x 16 chambers (chamber cross section 8 mm x 8 mm; the distance between chamber centers, 16 mm) and a matrix of 27 x 27 chambers (chamber cross section 5 mm x 5 mm; the distance between chamber centers is 10 mm). The two-dimensional response function of a single chamber is experimentally determined by scanning it with a slit beam. For dosimetric plan verification, the expected two-dimensional distribution of the array signals is calculated via convolution of the planned dose distribution, obtained from the treatment planning system, with the two-dimensional response function of a single chamber. By comparing the measured two-dimensional distribution of the array signals with the expected one, a distribution of deviations is obtained that can be subjected to verification criteria, such as the gamma index criterion. As an example, this verification method is discussed for one sequence of an IMRT plan. The error detection capability is demonstrated in a case study. Both versions of two-dimensional ionization chamber arrays, together with the developed treatment plan verification strategy, have been found to provide a suitable and easy-to-handle quality assurance instrument for IMRT.

Computer-Aided Design↗

[Resolution and sensitivity of a two-dimensional ionisation chamber array (PTW type 10024)].

The two-dimensional verification of intensity-modulated radiation plans is one of the major requirements for the safe application of this technique. The present study examines the resolution and sensitivity of a two-dimensional ionisation-chamber array (PTW2D-Array, type 10024), which can be used for plan verification instead of films. According to the Shannon-Nyquist theorem, the resolution of the 2D-Array is sufficient for dose distributions with a minimal field size of 2 cm x 2 cm. The minimal field size can be reduced to 1 cm x 1 cm by shifting the array 5 mm in the direction of the MLC movement and by repeating the measurements. The high sensitivity against a monitor decalibration for a single field of a sequence is demonstrated on the basis of an individual case. The minimal threshold for MLC misalignment detected by a chamber of the array is less than 1 mm. Therefore, the resolution capabilities of the 2D-Array are sufficient for most intensity-modulated radiation therapy (IMRT)fields.

Humans↗

[Use of a two-dimensional ionization chamber array for quality assurance in medical linear accelerators].

Two-dimensional dosimetry measurements are an important tool of Quality Assurance in modern radiotherapy techniques, such as the Intensity Modulated Radiation Therapy (IMRT). Common procedures are usually based on the use of films or semiconductor arrays as dosimeters. This paper presents our experience with a two-dimensional ionization-chamber array. The methods presented here allow the daily use of the array for a constancy check of the accelerator. It is also shown that the position of the individual leafs of the multi-leaf collimator (MLC) can be verified to within +/- 1 mm of their calibration. A procedure for the measurements is described and discussed.

Calibration↗