PubMed Health⌕ Search

Biomedical subjects

Ralf Koos

Publications and source records attributed to Ralf Koos.

At least 19 recordsLinked to original sources

Prevalence and clinical importance of aortic valve calcification detected incidentally on CT scans: comparison with echocardiography.

PURPOSE: To evaluate retrospectively the prevalence and grade of aortic valve calcification incidentally detected on chest multi-detector row computed tomographic (CT) scans and to compare the grade of calcification with the severity of aortic valve disease as assessed with echocardiography. MATERIALS AND METHODS: Patient informed consent was waived by the institutional board on medical ethics that approved this study. The authors identified 402 patients (231 men and 171 women; mean age, 62.5 years +/- 12.1) of 1820 patients who underwent chest multi-detector row CT between July 2001 and August 2004 and also underwent echocardiography. Aortic valve calcification at multi-detector row CT was visually graded on a scale ranging from 0 to 4 (0 = no calcification, 4 = severe calcification). CT findings were correlated with hemodynamic data obtained at echocardiography. Patients without aortic stenosis were compared with patients with aortic stenosis. The Student t test, Spearman correlation coefficient, chi(2) analysis, and an unweighted kappa test were used to compare results. RESULTS: Aortic valve calcification was noted on multi-detector row CT scans in 72 of the 402 patients (18%). Twelve of 20 patients (60%) with grade 3 or grade 4 calcification on CT scans had aortic stenosis at echocardiography, compared with only nine of 382 patients (2.4%) with grade 0-2 calcification (P < .001). Significant correlations were observed between the grade of aortic valve calcification and the echocardiographically determined mean (r = 0.45, P = .03) and peak transvalvular gradient (r = 0.47, P = .03). There was substantial agreement between the grade of valve calcification at multi-detector row CT and the severity of aortic valve disease at echocardiography (kappa = 0.67). CONCLUSION: Aortic valve calcification was an incidental finding on 18% of multi-detector row CT scans. The grade of aortic valve calcification is correlated with the hemodynamic severity of aortic valve disease as determined with echocardiography.

Aortic Valve↗

The accuracy of 1- and 3-mm slices in coronary calcium scoring using multi-slice CT in vitro and in vivo.

The accuracy of coronary calcium scoring using 16-row MSCT comparing 1- and 3-mm slices was assessed. A thorax phantom with calcium cylinder inserts was scanned applying a non-enhanced retrospectively ECG-gated examination protocol: collimation 12 x 0.75 mm; 120 kV; 133 mAs(eff). Thirty-eight patients were examined using the same scan protocol. Image reconstruction was performed with an effective slice thickness of 3 and 1 mm. The volume score, calcium mass and Agatston score were determined. Image noise was measured in both studies. The volume score and calcium mass varied less than the Agatston score. The overall measured calcium mass compared to the actual calcium mass revealed a relative difference of +2.0% for 1-mm slices and -1.2% for 3-mm slices. Due to increased image noise in thinner slices in the patient study (26.1 HU), overall calcium scoring with a scoring threshold of 130 HU was not feasible. Interlesion comparison showed significantly higher scoring results for thinner slices (all P<0.001). A similar accuracy comparing calcium scoring results of 1- and 3-mm slices was shown in the phantom study; therefore, the potentially necessary increase of the patient's dose in order to achieve assessable 1-mm slices with an acceptable image-to-noise-ratio appears not to be justified.

Aged↗

Automated vs. manual assessment of left ventricular function in cardiac multidetector row computed tomography: comparison with magnetic resonance imaging.

We compared semiautomatic contour detection and manual contour tracing in cardiac multidetector row computed tomography (MDCT) with magnetic resonance imaging (MRI) for calculation of left-ventricular (LV) volumes. The study included 30 patients who underwent contrast-enhanced cardiac MDCT and cardiac cine-MRI. Were calculated 8 mm short-axis slices from MDCT data using three-dimensional multiphase image reconstruction. LV volumes including peak ejection rate and peak filling rate were calculated from manually and semiautomatically determined contours. Results were compared to those from cine-MRI with manually drawn contours as the standard of reference. We found good agreement for the LV volumes, with an ejection fraction of 47.1+/-9.4% for manually drawn contours, 47.9+/-9.9% for semiautomatically detected contours on MDCT, and 48.0+/-10.2% for MRI. Except for peak-filling rate analysis of variance revealed no difference between any of these techniques. Bland-Altman plots and Lin's concordance correlation coefficient showed best agreement between MRI and manual contour tracing in MDCT. Calculation of LV volumes using either semiautomatic or manual contour tracing in cardiac MDCT is therefore feasible when compared to MRI. Automated contour detection needs to be improved to equal manual contour tracing.

Algorithms↗

[Prevalence and pathogenesis of aortic valve calcifications].

BACKGROUND: Calcific aortic valve disease is present in more than 25% of patients > 65 years of age and is associated with a 50% increased risk of cardiovascular events. The clinical significance of aortic valve calcification detected incidentally by radiologic examinations, especially on CT scans of the chest, was unknown. Concerning the multifactorial pathogenesis of aortic valve calcification, recent data indicate that, besides other factors, also the regulators of calcification play a key role in the disease process. PURPOSE: This study aims to give an overview of the prevalence and clinical significance of incidentally detected aortic valve calcifications. Moreover, the role calcification inhibitors in the pathogenesis of aortic valve calcification is discussed.

Adult↗

Variability of aortic valve calcification measurement with multislice spiral computed tomography.

OBJECTIVES: We sought to assess the variability of aortic valve calcifications (AVCs) regarding the reconstruction window at different heart phases using multislice-spiral computed tomography. MATERIALS AND METHODS: A total of 46 patients (26 men; mean age. 65 years) underwent AVC scoring with multislice-spiral computed tomography (12 x 0.75 mm, 120 kV, 133 mAseff). Image reconstruction was performed every 10% of the RR-interval (0-90%). AVC was quantified using Agatston score, calcium volume, and calcium mass. Images were assessed for least motion artifacts. Coefficients of variation and Wilcoxon test were calculated. RESULTS: AVC scores are lowest at 60% and highest at 0% of the RR-interval (P < 0.001). Mean coefficients of variation were 36.2% (Agatston score), 38.7% (calcium volume), and 32.9% (calcium mass). At 60% (50-70%). minimal motion artifacts and the lowest variability of the scores were found. CONCLUSIONS: AVC scores show large variability depending on the point of image reconstruction. Diastolic image reconstruction at 60% of the RR-interval is recommended.

Adult↗

Quantification of aortic valve calcification using multislice spiral computed tomography: comparison with atomic absorption spectroscopy.

OBJECTIVES: Multislice spiral computed tomography (MSCT) allows the in vivo detection of valvular calcification. The aim of this study was to validate the quantification of aortic valve calcification (AVC) by MSCT with in vitro measurements by atomic absorption spectroscopy. METHODS: In 18 patients with severe aortic stenosis, 16 detector row MSCT (SOMATOM Sensation 16, Siemens, Forchheim, Germany with scan parameters as follows: 420 milliseconds tube rotation time, 12 x 0.75 mm collimation, tube voltage 120 KV) was performed before aortic valve replacement. Images were reconstructed at 60% of the RR interval with an effective slice thickness of 3 mm and a reconstruction increment of 2 mm. AVC was assessed using Agatston AVC score, mass AVC score, and volumetric AVC score. After valve replacement, the calcium content of the excised human stenotic aortic valves was determined in vitro using atomic absorption spectroscopy. RESULTS: The mean Agatston AVC score was 3,842 +/- 1,790, the mean volumetric AVC score was 3,061 +/- 1,406, and mass AVC score was 888 +/- 492 as quantified by MSCT. Atomic absorption spectroscopy showed a mean true calcification mass (Ca5(PO4)3OH) of 19 +/- 8 mass%. There was a significant correlation between in vivo AVC scores determined by MSCT and in vitro mean true calcification mass (r = 0.74, P = 0.0004 for mass AVC score, r = 0.79, P = 0.0001 for volumetric AVC score and r = 0.80, P = 0.0001 for Agatston AVC score) determined by atomic absorption spectroscopy. Linear regression analysis showed a significant association between the degree of hydroxyapatite (given in mass%) in the aortic valve and the degree of AVC (R = 0.74, F = 19.6, P = 0.0004 for mass AVC score, R = 0.80, F = 29.3, P = 0.0001 for Agatston AVC score and R = 0.79, F = 27.3, P = 0.0001 for volumetric AVC score) assessed by MSCT. CONCLUSION: MSCT allows accurate in vivo quantification of aortic valve calcifications.

Aged↗

Multicentre evaluation of a rule-based data filter for home monitoring of implanted cardioverter defibrillators.

We developed a rule-based data filter for the automatic interpretation of data transmitted from implantable cardioverter defibrillators (ICDs). The feasibility and user acceptability of the data filter were tested in a multicentre study. Fifteen European centres analysed 10 cases each. The cases represented ICD follow-up findings, e.g. new tachycardia, battery depletion or sensing defects. The mean follow-up period was 68 days (SD 35). A questionnaire was used to collect information regarding the functionality and general concept of automatic data interpretation. A score of five or above (range 1-9) was classified as acceptable. According to the questionnaires, there was a high degree of satisfaction with the general concept of automatic data interpretation (mean 6.7, SD 1.2) and with user guidance (mean 7.1, SD 0.8). Safety (mean 7.0, SD 1.4) and accuracy (mean 6.7, SD 1.4) of the evaluation of device-related and clinical problems were regarded as high. Support in daily routine was considered to be high (mean 7.3, SD 1.1) as the system was easy to understand (mean 7.5, SD 0.9). The results indicated a high user acceptance with easy system handling.

Attitude of Health Personnel↗

Lower serum calcium levels are associated with greater calcium hydroxyapatite deposition in native aortic valves of male patients with severe calcific aortic stenosis.

BACKGROUND AND AIM OF THE STUDY: The study aim was to evaluate the relationship between serum calcium levels and the degree of calcification found in stenotic aortic valves. METHODS: Using atomic absorption spectroscopy, the hydroxyapatite content of 228 excised human stenotic aortic valves was determined and expressed as a percentage of valve mass. Left heart catheterization preceded valve replacement. In addition, serum levels of calcium and creatinine were determined before native calcific aortic valve excision. RESULTS: Valves from male patients contained more hydroxyapatite than those of female patients (26 +/- 9 versus 22 +/- 9 mass%; p < 0.001). Patients presenting with lower serum calcium levels showed a slight trend towards higher levels of valve calcification (r = -0.15, p = 0.026), but this association appeared only within the subgroup of male patients. Male patients with lowest serum calcium levels displayed greatest valvular hydroxyapatite deposition (1st calcium tertiary: 29.5 +/- 8.9 mass% versus 2nd calcium tertiary 26.4 +/- 7.8 mass% versus 3rd calcium tertiary 21.4 +/- 8.9 mass%; n = 122; p = 0.001; r = -0.25; p = 0.006). This association was even more distinct in male patients with normal serum creatinine levels. Furthermore, serum calcium was inversely and significantly associated with serum C-reactive protein in male patients (r = - 0.34; p < 0.001). CONCLUSION: Serum calcium levels appear to be inversely related to valve calcification in patients with severe calcific aortic stenosis (AS). This finding indicates the importance of systemic calcium metabolism in calcific AS, independent of manifest disorders of calcium metabolism or renal function. Interestingly, this association was evident only in male patients, suggesting a gender-dependent pathogenesis.

Aged↗

Global left ventricular function in cardiac CT. Evaluation of an automated 3D region-growing segmentation algorithm.

The purpose was to evaluate a new semi-automated 3D region-growing segmentation algorithm for functional analysis of the left ventricle in multislice CT (MSCT) of the heart. Twenty patients underwent contrast-enhanced MSCT of the heart (collimation 16 x 0.75 mm; 120 kV; 550 mAseff). Multiphase image reconstructions with 1-mm axial slices and 8-mm short-axis slices were performed. Left ventricular volume measurements (end-diastolic volume, end-systolic volume, ejection fraction and stroke volume) from manually drawn endocardial contours in the short axis slices were compared to semi-automated region-growing segmentation of the left ventricle from the 1-mm axial slices. The post-processing-time for both methods was recorded. Applying the new region-growing algorithm in 13/20 patients (65%), proper segmentation of the left ventricle was feasible. In these patients, the signal-to-noise ratio was higher than in the remaining patients (3.2+/-1.0 vs. 2.6+/-0.6). Volume measurements of both segmentation algorithms showed an excellent correlation (all P<or=0.0001); the limits of agreement for the ejection fraction were 2.3+/-8.3 ml. In the patients with proper segmentation the mean post-processing time using the region-growing algorithm was diminished by 44.2%. On the basis of a good contrast-enhanced data set, a left ventricular volume analysis using the new semi-automated region-growing segmentation algorithm is technically feasible, accurate and more time-effective.

Aged↗

Multidetector-row computed tomography vs. angiography and intravascular ultrasound for the evaluation of the diameter of proximal coronary arteries.

BACKGROUND: Multidetector-row computed tomography has evolved as a promising method for noninvasive visualization of coronary arteries and detection of coronary artery calcification. We determined the accuracy of computed tomography for measurement of coronary artery lumen diameters in comparison to quantitative coronary angiography and intravascular ultrasound (IVUS). METHODS: Eighteen patients (4 female, age 62+/-8 years) with known or suspected coronary artery disease were investigated by computer tomography (4x1 mm collimation, rotation time: 500 ms, table feed: 1.5 mm/rotation). Coronary angiography and IVUS were performed in the left anterior descending, left circumflex and right coronary artery according to common standards. Lumen diameters were measured at the origin of the coronary artery and 10, 30 and 50 mm distally. Results of all three techniques were compared. RESULTS: Only measuring points evaluated by all measuring techniques were included. Thus, 50 diameters could be analyzed. The correlation R between computed tomography and angiography measures was 0.909 (p<0.05) at the origin of the artery, 0.907 (p<0.05) at 10, 0.841 (p<0.05) at 30 and 0.780 (p<0.05) at 50 mm distally. The correlation R between computed tomography and IVUS was 0.934 at the origin (p<0.05), 0.867 at 10 (p<0.05), 0.880 at 30 (p<0.05) and 0.727 at 50 mm (p<0.05). CONCLUSIONS: Multidetector-row computed tomography is a promising tool to measure the proximal coronary artery diameters with a good correlation to angiographic and IVUS measurements. Multidetector-row computed tomography might become more feasible with improvement of technology, e.g. with 16 row scanners.

Coronary Angiography↗

Relation of oral anticoagulation to cardiac valvular and coronary calcium assessed by multislice spiral computed tomography.

Vitamin K antagonists, known as oral anticoagulants, affect the synthesis and function of the matrix Gla protein, which is a potent inhibitor of tissue calcification. We performed multislice spiral computed tomography in 86 patients (53 men, mean age 71 +/- 8 years) with calcific aortic valve disease to quantitate the amount of calcification in the aortic valve and coronary arteries. Patients with long-term oral anticoagulation therapy (mean duration 88 +/- 113 months; n = 23) were compared with those without anticoagulation (n = 63). No differences were found in the demographic, clinical, or echocardiographic characteristics between the 2 study groups. Patients on oral anticoagulant therapy had increased coronary calcium (coronary Agatston score 1,561 +/- 1,141 vs 738 +/- 978, respectively; p = 0.024) and valvular calcium (valvular Agatston score 2,410 +/- 1,759 vs 1,070 +/- 1,085, respectively; p = 0.002) compared with patients without anticoagulation treatment. The results of our study have demonstrated that oral anticoagulation may be associated with increased valvular and coronary calcium in patients with aortic valve disease, presumably due to decreased activation of the matrix Gla protein.

Administration, Oral↗

Influence of a small field-of-view size on the detection of coronary artery calcifications with MSCT: in vitro and in vivo study.

The purpose of this study is to asses the impact of small field-of-view (FOV) sizes on the detection of coronary artery calcifications using multislice-spiral computed tomography (MSCT). First, a static chest phantom containing calcium inserts was scanned 10 times using a standardized scan protocol. Secondly, 50 patients (28 male, 63.6+/-10.6 years) underwent cardiac MSCT using the same protocol. Images were reconstructed with three different FOV sizes (180x180, 220x220, 380x380 mm(2)). Coronary calcium scoring and risk stratification were performed for each image series. In the phantom study, the Agatston score calculated with a FOV size of 180x180 mm(2) was 657.80+/-20.05. At a FOV of 220x220 mm(2) and 380x380 mm(2), the corresponding values were 657.04+/-21.36 and 655.04+/-20.74, respectively. The corresponding values in the patient study were 541.65+/-869.87, 541.91+/-872.57 and 536.61+/-867.81. No statistically significant differences in the calcium score were found comparing different FOV sizes. Significantly more lesions (p=0.00149) were detected in the patient study. Comparing the different FOV sizes of 180x180 mm(2) and 220x220 mm(2) (380x380 mm(2)), four (six) patients had to be assigned to different risk groups. The use of small FOV sizes resulted in an improved detection of coronary calcifications influencing the risk stratification for further cardiac events in MSCT coronary calcium scoring.

Adult↗

Preliminary experience in the assessment of aortic valve calcification by ECG-gated multislice spiral computed tomography.

BACKGROUND: The aim was to correlate the degree of valvular calcification in patients with aortic stenosis determined by retrospectively electrocardiogram (ECG)-gated multislice spiral computed tomography with stenosis severity assessed by cardiac catheterization. METHODS: Prospective study on 41 patients (18 men, mean age 71+/-8 years) with aortic stenosis, who underwent four detector row multislice spiral computed tomography and cardiac catheterization. Severity of aortic stenosis was classified by cardiac catheterization. Aortic valve area, peak to peak and mean transvalvular gradients were correlated with the degree of calcification determined by multislice spiral computed tomography. Aortic valve calcification was assessed using aortic Agatston score, aortic mass score and aortic volume score. RESULTS: All measured aortic valve calcification scores were significantly higher in patients with severe aortic stenosis (n=29) than in patients with moderate (n=7) or mild aortic stenosis (n=5, p<0.001). Aortic valve calcification scores correlated significantly with aortic valve area (r=-0.49, p=0.001 for aortic mass score) and with peak to peak (r=0.68, p<0.001) and mean (r=0.60, p<0.001) transvalvular gradients. CONCLUSIONS: Severity of aortic valve calcification assessed by cardiac multislice spiral computed tomography is inversely related to aortic valve area and positively correlated with transvalvular gradients. Based on this preliminary data larger studies should be performed with echocardiography as a reference standard in order to validate this new information and its utility in the clinical management of the patient.

Aged↗

Assessment of myocardial viability in reperfused acute myocardial infarction using 16-slice computed tomography in comparison to magnetic resonance imaging.

OBJECTIVES: The aim of this study was to examine if contrast-enhanced multislice spiral computed tomography (MSCT) is comparable to contrast-enhanced magnetic resonance imaging (MRI) for depiction of acute myocardial infarction (MI). BACKGROUND: Delayed-enhancement MRI of MI is well established, but there are no clinical reports about MSCT for this indication. Early perfusion deficit on MSCT has been reported to correlate with the presence of MI. METHODS: A total of 28 consecutive patients (23 men; 55.9 +/- 11.4 years) with reperfused MI underwent contrast-enhanced cardiac 16-slice MSCT. Images were acquired in the arterial phase and the late phase 15 min after administration of 120 ml contrast material. Within 5 days, patients underwent MRI after administration of 0.2 mmol Gd-dimeglumine/kg/bodyweight. All examinations were completed within two weeks after MI. The area of MI was compared between the different imaging techniques using Bland-Altman method and multivariate analysis. Agreement of the contrast enhancement patterns was evaluated with a weighted kappa test. RESULTS: Mean infarct size on MRI was 31.2 +/- 22.5% per slice compared with 33.3 +/- 23.8% per slice for late-enhancement MSCT and 24.5 +/- 18.3% per slice for early-perfusion-deficit MSCT. Bland-Altman data showed a good agreement between late-enhancement MRI and late-enhancement MSCT. Contrast enhancement patterns demonstrated an excellent agreement between late-enhancement MRI and late-enhancement MSCT (kappa = 0.878). The results were worse comparing MRI and early-phase MSCT (kappa = 0.635). CONCLUSIONS: Multislice spiral computed tomography allows for the assessment of acute MI. Late-enhancement MSCT appears to be as reliable as delayed contrast-enhanced MRI in assessing infarct size and myocardial viability in acute MI.

Adult↗

Sixteen-slice spiral CT versus MR imaging for the assessment of left ventricular function in acute myocardial infarction.

The aim of this study was to assess global left ventricular (LV) function and regional wall motion using retrospectively ECG-gated 16-slice computed tomography (CT) in comparison with magnetic resonance imaging (MRI). Twenty-one patients (18 male, 65.5+/-8.6 years) with acute myocardial infarction underwent multislice spiral CT (MSCT) and MRI. From manually drawn endo- and epicardial contours, LV volumes including myocardial mass, peak filling rate (PFR), peak ejection rate (PER), time to PER (TPER) and time from end-systole to PFR (TPFR) were calculated. Regional wall motion was assessed from cine loops using a 16-segment model of the left ventricle. LV function was analyzed using the Bland-Altman method, Pearson's correlation coefficient, multivariate analysis and post hoc t tests. Regional wall motion was evaluated with weighted kappa-statistics. Multivariate analysis revealed significant differences for global LV function as determined by MSCT and MRI. Post hoc t-tests showed significant differences for end-diastolic volume (EDV), PFR and TPER (P<0.05), while there was a good agreement for the LV volumes with an ejection fraction of 46.9+/-8.4% for MSCT and 46.9+/-8.9% for MRI. PER, PFR, TPER and TPFR presented a poor correlation and a wide range of scattering between MSCT and MRI. Regional wall motion scores showed a good agreement with kappa=0.791. Sixteen-slice spiral CT allows for reliable assessment of LV volumes, but is not yet suited for the evaluation of all functional parameters. Assessment of regional wall motion at rest is feasible.

Female↗

Coronary calcium scoring using 16-row multislice computed tomography: nonenhanced versus contrast-enhanced studies in vitro and in vivo.

OBJECTIVES: We sought to assess the agreement of coronary artery calcium score in nonenhanced and contrast-enhanced multislice-spiral computed tomography. MATERIALS AND METHODS: Vessel phantoms and 36 patients underwent nonenhanced and contrast-enhanced cardiac multislice-spiral computed tomography (Sensation 16; Siemens, Germany). Reconstruction-parameters: slice thickness 3 mm, increment 2 mm, kernels B35f and B30f. The Agatston score, calcium mass, and number of lesions were calculated. Images were scored using detection thresholds of 130 Hounsfield units (HU) and 350 HU. Based on the Agatston score, risk stratification was performed. RESULTS: In the phantom and patient study, altering the threshold from 130 to 350 HU led to a significant decrease in the mean Agatston score (phantom: 54.6%, patients: 66.7%) and calcium mass (33.0%, 47.0%) (B35f). Contrast-enhanced studies (threshold: 350 HU) showed an increase of the mean Agatston score (71.0%, 20.7%) and calcium mass (81.0%, 16.0%) when compared with nonenhanced scans (threshold: 350 HU). A total of 57% of all patients were assigned to different risk groups. CONCLUSIONS: Contrast material may simulate calcification; therefore, calculation of the coronary calcium score from contrast-enhanced images is not reliable.

Calcinosis↗

Effect of varying slice thickness on coronary calcium scoring with multislice computed tomography in vitro and in vivo.

OBJECTIVES: To compare coronary calcium scoring results (calcium volume, calcium mass, Agatston score, and number of lesions) of different slice thicknesses using a 16-slice CT (MSCT) scanner. MATERIALS AND METHODS: A nonmoving anthropomorphic thorax phantom with calcium cylinders of different sizes and densities was scanned 30 times with repositioning applying a standardized retrospectively ECG-gated MSCT (SOMATOM Sensation 16; Siemens, Forchheim, Germany) scan protocol: collimation 12 x 0.75 mm, tube voltage 120 kV, effective tube current time-product 133 mAs(eff). Fifty patients (29 male; age 57.2 +/- 8.4 years) underwent a nonenhanced scan applying the same scan protocol. Two image sets (effective slice thicknesses 3 mm and 1 mm) were reconstructed at 60% of the RR interval. Image noise was measured in both studies. Calcium volume, calcium mass and Agatston score were calculated using a commercially available software tool. RESULTS: Due to increased image noise in thinner slices, calcium scoring in all scans was performed applying a scoring threshold of 350 HU. In the phantom study, 1-mm slices showed significantly higher scoring results in respect to calcium volume (+8.2%), calcium mass (+12.5%), and Agatston score (+5.3%) (all P < 0.0001). In the patient study, 27 patients had coronary calcifications in 3-mm slices, and 31 patients had coronary calcifications in 1-mm slices. Thinner slices showed significantly higher scoring results in respect to volume (+47.1%), mass (+47.2%), and Agatston score (+29.7%) (all P < 0.0001). CONCLUSIONS: When comparing 3-mm and 1-mm slices in coronary calcium scoring in MSCT, thinner slices lead to significantly increased scoring results.

Aged↗

Imaging of the cardiac venous system: comparison of MDCT and conventional angiography.

OBJECTIVE: Diagnostic and therapeutic strategies in electrophysiology and interventional cardiology include the coronary venous system. The purpose of this study was to compare MDCT angiography with conventional coronary sinus angiography in terms of detailed anatomic display of the coronary veins. CONCLUSION: MDCT angiography is a reliable alternative to conventional coronary sinus angiography for detailed anatomic display of the coronary veins.

Coronary Angiography↗