PubMed Health⌕ Search

Biomedical subjects

Ralf Krakor

Publications and source records attributed to Ralf Krakor.

3 recordsLinked to original sources

Intraoperative left atrial ablation (for atrial fibrillation) using a new argon cryocatheter: early clinical experience.

PURPOSE: Recently surgical treatment of atrial fibrillation has gained more popularity and presently is being performed in large numbers of patients. This report describes our early experience in treatment of patients with chronic or paroxysmal atrial fibrillation with a new tool for left atrial cryoablation. DESCRIPTION: From July 2002 through January 2003, 28 patients underwent left atrial cryoablation with the Surgifrost CryoCath. Patients underwent cryotherapy as an isolated procedure (n = 1), in combination with mitral valve surgery (n = 13), or with other surgical procedures (n = 14). In all patients contiguous lesion lines to the orifices of the pulmonary veins connected to the mitral annulus and the atriotomy were created. Surgery was performed through a conventional sternotomy in 8 patients (29%) and a right lateral minithoracotomy using video-assistance in 20 patients (71%). EVALUATION: Postoperatively sinus rhythm was restored in 27 patients (96%). At discharge 82% (23/28) of patients were in sinus rhythm and 18% (5/28) were in atrial fibrillation. Four patients (14%) required pacemaker implantation. There was no in-hospital mortality. At 6-months follow-up (19/28 patients) all were alive and 74% were in stable sinus rhythm, New York Heart Association functional class was 1.2 +/- 0.4. CONCLUSIONS: As indicated by our small and early patient cohort left atrial cryoablation with the Surgifrost argon cryocatheter is effective for the treatment of atrial fibrillation. This new device is technically easy to handle, it can be applied through a median sternotomy or lateral minithoracotomy. Long-term follow-up is necessary to evaluate further rhythm outcome.

Adult↗

Right heart support during off-pump coronary artery bypass surgery--a multi-center study.

BACKGROUND: Off-pump coronary artery bypass (OPCAB) surgery for posterior and inferior wall vessels requires heart displacement, which leads to hemodynamic instability. Based on results indicating that displacement primarily alters right heart function, this study evaluates the safety and efficacy of right heart support during OPCAB surgery to the posterior and inferior wall vessels. METHODS: In a multi-center, prospective study, 25 patients underwent multi-vessel OPCAB surgery. Right heart support was carried out using the Enabler circulatory support system (Hemodynamics Systems Ltd., Upper Yokneam, Israel). Hemodynamic measurements were recorded at baseline and during heart displacement with and without right heart support. RESULTS: No mortality was recorded. Mean graft number was 2.25 +/- 0.36. Inability to position the Enabler system occurred in five cases. Once the Enabler was properly positioned, there was no case of conversion to cardiopulmonary bypass (CPB) due to failure of the Enabler to provide adequate support. Cardiac index (CI) declined from 2.4 +/- 0.5 L/min x /m2 to 1.6 +/- 0.6 L/min x /m2 (p <0.05) during heart displacement and increased to 2.3 +/- 0.6 L/min x /m2 (p <0.05) following Enabler activation. Mean arterial blood pressure (MAP) dropped from 82 +/- 18.6 mmHg to 53.1 +/- 16.6 mmHg (p <0.001) during heart displacement and was restored to 69.8 +/- 19.4 mmHg (p <0.001) with Enabler support. CONCLUSIONS: Heart displacement caused a significant hemodynamic deterioration that was stabilized with right heart support. The Enabler system is safe and effective in facilitating multi-vessel OPCAB surgery. However, there are still serious technical problems during cannula insertion that cause an unacceptable failure rate of device utilization.

Aged↗