Time-resolved 3D contrast-enhanced MRA with GRAPPA on a 1.5-T system for imaging of craniocervical vascular disease: initial experience.

INTRODUCTION: For three-dimensional (3D) imaging with magnetic resonance angiography (MRA) of the cerebral and cervical circulation, both a high temporal and a high spatial resolution with isovolumetric datasets are of interest. In an initial evaluation, we analyzed the potential of contrast-enhanced (CE) time-resolved 3D-MRA as an adjunct for neurovascular MR imaging. METHODS: In ten patients with various cerebrovascular disorders and vascularized tumors in the cervical circulation, high-speed MR acquisition using parallel imaging with the GeneRalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) algorithm on a 1.5-T system with a temporal resolution of 1.5 s per dataset and a nearly isovolumetric spatial resolution was applied. The results were assessed and compared with those from conventional MRA and digital subtraction angiography (DSA). RESULTS: CE time-resolved 3D-MRA enabled the visualization and characterization of high-flow arteriovenous shunts in cases of vascular malformations or hypervascularized tumors. In steno-occlusive disease, the method provided valuable additional information about altered vessel perfusion compared to standard MRA techniques such as time-of-flight (TOF) MRA. The use of a nearly isovolumetric voxel size allowed a free-form interrogation of 3D datasets. Its comparatively low spatial resolution was found to be the major limitation. CONCLUSION: In this preliminary analysis, CE time-resolved 3D-MRA was revealed to be a promising complementary MRA sequence that enabled the visualization of contrast flow dynamics in various types of neurovascular disorders and vascularized cervical tumors.

Adult↗

A polymer-based MR-compatible guidewire: a study to explore new prospects for interventional peripheral magnetic resonance angiography (ipMRA).

PURPOSE: To introduce a newly developed polymer-based and magnetic resonance (MR)-compatible guidewire and to explore its capabilities with respect to interventional peripheral magnetic resonance angiography (ipMRA) in a flow phantom. MATERIALS AND METHODS: The guidewire is based on a polyetheretherketone (PEEK) polymer core, and small iron particles are embedded in its coating. A passive device tracking technique was designed utilizing a susceptibility artifact induced by the wire in images acquired with a balanced steady-state free precession (b-SSFP) sequence using small flip angles. The position of the guidewire tip was determined from image intensity maxima and overlayed onto a roadmap in near real-time. Guidewire tracking and balloon angioplasty of an artificial stenosis were attempted in two configurations of a flow phantom. RESULTS: Successful passive guidewire tracking was performed for all phantom configurations. Robustness and accuracy of the tracking technique were sufficient for phantom studies. A balloon catheter was placed into the stenosis using the guidewire under complete MR guidance, and subsequent balloon angioplasty yielded improved flow conditions. CONCLUSION: The new guidewire is well-suited for clinical application due to an absence of the risk of core fracture and its atraumatic flexible tip. It opens novel prospects for the realization of ipMRA in humans that need to be explored in further studies.

Angiography, Digital Subtraction↗

Combo acquisitions: balancing scan time reduction and image quality.

Recently a new technique for the combined acquisition of multicontrast images, termed "combo acquisition," was introduced. In combo acquisitions, the three concepts of 1) variable acquisition parameters, 2) k-space data sharing, and 3) multicontrast imaging are systematically integrated to reduce MRI scan time and improve data utilization in a clinical setting. In this study, two-contrast and three-contrast spin-echo (SE) and turbo spin-echo (TSE) combo acquisition protocols that were designed and optimized in simulation experiments were implemented on a 1.5 T clinical scanner. Phantom and human brain data from volunteers and patients were acquired. Scan time reductions of 25-52% were achieved compared to standard acquisitions, largely confirming the simulation results. We evaluated the resulting images by quantitatively analyzing the preservation of contrast and the signal-to-noise ratio (SNR). In addition, data sets for 10 clinical cases obtained with TSE combo and corresponding standard acquisitions were graded by two experienced neuroradiologists in terms of the level of artifacts and image quality for comparison. Only minor image degradation with the combo scans was observed, indicating an inherent trade-off between scan time reduction and image quality. The specific aspects of combo acquisitions with respect to motion, flow, and k-space data weighting are discussed.

Algorithms↗

Combined MR data acquisition of multicontrast images using variable acquisition parameters and K-space data sharing.

A new technique to reduce clinical magnetic resonance imaging (MRI) scan time by varying acquisition parameters and sharing k-space data between images, is proposed. To improve data utilization, acquisition of multiple images of different contrast is combined into a single scan, with variable acquisition parameters including repetition time (TR), echo time (TE), and echo train length (ETL). This approach is thus referred to as a "combo acquisition." As a proof of concept, simulations of MRI experiments using spin echo (SE) and fast SE (FSE) sequences were performed based on Bloch equations. Predicted scan time reductions of 25%-50% were achieved for 2-contrast and 3-contrast combo acquisitions. Artifacts caused by nonuniform k-space data weighting were suppressed through semi-empirical optimization of parameter variation schemes and the phase encoding order. Optimization was assessed by minimizing three quantitative criteria: energy of the "residue point spread function (PSF)," energy of "residue profiles" across sharp tissue boundaries, and energy of "residue images." In addition, results were further evaluated by quantitatively analyzing the preservation of contrast, the PSF, and the signal-to-noise ratio. Finally, conspicuity of lesions was investigated for combo acquisitions in comparison with standard scans. Implications and challenges for the practical use of combo acquisitions are discussed.

Algorithms↗