PubMed Health⌕ Search

Biomedical subjects

Ralph Müller

Publications and source records attributed to Ralph Müller.

52 records · Page 3Linked to original sources

Activation of T cells via tumor antigen specific chimeric receptors: the role of the intracellular signaling domain.

T cells engineered to express hybrid receptors with antibody defined specificity can successfully be targeted to tumor cells. In order to select intracellular domains of chimeric receptors capable of efficiently activate T cells in vitro and in vivo, we compared the function of receptors, which share the same extracellular antigen-binding part, joined to different intra-cellular signal transduction units. The antigen binding domain of the receptors was a single-chain fragment of a monoclonal antibody, which recognize a High Molecular Weight Melanoma-Associated Antigen with high affinity. The intracellular tails were derived from the T-cell receptor zeta chain (TCR-zeta), from the B-cell receptor Ig-alpha molecule and from a mutated Ig-alpha molecule able of stronger signal transduction. We compared the activity of the different chimeric receptors at a single-cell level by using a T-cell line that expressed an activation-dependent EGFP-reporter gene. Upon cross-linking with immobilized antibodies, all receptors were able to induce EGFP expression in the majority of the T cells. In contrast, EGFP expression was induced by contact to melanoma cells in vitro only in T cells that expressed the chimeric receptor that contained the TCR-zeta intracellular tail. In these T cells, the co-expression of chimeric receptors that contain a mutated Ig-alpha tail lowers the threshold of T-cell activation and facilitates tumor recognition in vitro and in vivo. Given their specificity and efficiency, T cells grafted with these type of receptors may represent potential candidates for cancer passive immunotherapy.

Animals↗

Budesonide foam vs. hydrocortisone acetate foam in the treatment of active ulcerative proctosigmoiditis.

INTRODUCTION: Rectal administration of corticosteroids is advocated in patients with proctosigmoiditis who have failed therapy with mesalamine enema. Foam offers patients better tolerability than an enema. In this study the efficacy and adverse effects of a new budesonide foam are compared with the presently available hydrocortisone foam. METHODS: Two hundred fifty-one patients with proctosigmoiditis were randomly assigned to receive either budesonide foam or hydrocortisone foam for eight weeks. RESULTS: Remission rates were comparable in the budesonide and hydrocortisone groups, 53 and 52 percent, respectively. The mean disease activity index for the two groups decreased to a similar extent, from 7.2 +/- 1.9 and 7 +/- 2 to 3.6 +/- 3.1 and 3.9 +/- 3.4 in the budesonide and hydrocortisone groups, respectively. In a subgroup of patients who had not responded to rectal administration of mesalamine, 23 of 44 (52 percent) patients who received budesonide responded favorably to the foam, as compared with 14 of 38 (37 percent) patients who received hydrocortisone (P = not significant). Low plasma cortisol occurred in 3 percent of the budesonide group and in none of the hydrocortisone patients. CONCLUSIONS: This trial demonstrates a similar efficacy and safety of the two foams in patients with proctosigmoiditis.

Administration, Rectal↗

Combining high-resolution micro-computed tomography with material composition to define the quality of bone tissue.

Atraumatic fractures of the skeleton in osteoporotic patients are directly related to a deterioration of bone strength. However, the failure of the bone tissue to withstand functional load bearing cannot be explained as a simple decrease in bone mineral density (quantity); strength is also significantly dependent upon bone quality. While a formal definition of bone quality is somewhat elusive, at the very least, it incorporates architectural, physical, and biologic factors that are critical to bone strength. Such factors include bone morphology (ie, trabecular connectivity, cross-sectional geometry, longitudinal curvature); the tissue's material properties (eg, stiffness, strength); its chemical composition and architecture (eg, ratio of calcium to other components of the organic and/or inorganic phase, collagen orientation, porosity, permeability); and the viability of the tissue (eg, responsivity of the bone cell population). Combining high-resolution structural indices of bone, as determined by micro-computed tomography; material properties determined by nanoindentation; and the chemical make-up of bone, as determined by infrared spectroscopy, helps to provide critical information toward a more comprehensive assessment of the interdependence of bone quality, quantity, and fracture risk.

Animals↗

Physiologic weight-bearing increases new vessel formation during distraction osteogenesis: a micro-tomographic imaging study.

During distraction osteogenesis, large volumes of new bone are formed through the slow distraction of fracture callus. The newly formed bone is closely linked to angiogenesis and positively influenced by physiologic loading. In this study, a rat model was used to explore the correlation between these two observations. Unilateral femoral lengthenings were performed in 18 male Sprague-Dawley rats (400-500 g, age<6 months). Half of the animals were allowed to bear weight freely (WB) while the remaining animals were made non-weight-bearing via a through-knee amputation (NWB). After a seven-day latency period, femurs were lengthened 7 mm over 21 days. Animals were sacrificed at 7, 21, 35, and 49 days (0, 4.7, 7, and 7 mm of distraction) at which time lower extremity vessels were perfused with a 60% (w/v) barium sulfate suspension. High-resolution three-dimensional images of the vascular architecture were generated using a fan-beam micro-tomography machine by digitally separating the contrast-filled vessels from surrounding tissue. For two subvolumes, VOI(1), which included vessels in the medullary canal, cortex, and periosteum, and VOI(2), which included only vessels in the canal and cortex, the total tissue volume (TV), the volume of vessels (VV), and vessel diameter (VD) were determined. For the larger subvolume (VOI(1)), VV and vessel density (VV/TV) increased as a function of time (p<0.001) in WB animals. In NWB animals, VV increased significantly with time (p=0.029), while VV/TV did not (p=0.36). Increases in VV and VV/TV were significantly greater in WB animals than in NWB animals (p<0.01 and 0.05, respectively). VD was similar in both groups and did not change with time. Our data suggest that weight bearing stimulates new vessel formation during distraction osteogenesis.

Animals↗

Bone formation on tissue-engineered cartilage constructs in vivo: effects of chondrocyte viability and mechanical loading.

Interactions between bone and cartilage formation are critical during growth and fracture healing and may influence the functional integration of osteochondral repair constructs. In this study, the ability of tissue-engineered cartilage constructs to support bone formation under controlled mechanical loading conditions was evaluated using a lapine hydraulic bone chamber model. Articular chondrocytes were seeded onto polymer disks, cultured for 4 weeks in vitro, and then transferred to empty bone chambers previously implanted into rabbit femoral metaphyses. The effects of chondrocyte viability within the implanted constructs and in vivo mechanical loading on bone formation were tested in separate experiments. After 4 weeks in vivo, biopsies from the chambers consisted of a complex composite of bone, cartilage, and fibrous tissue, with bone forming in direct apposition to the cartilage constructs. Microcomputed tomography imaging of the chamber biopsies revealed that the implantation of viable constructs nearly doubled the bone volume fraction of the chamber tissue from 0.9 to 1.6% as compared with the implantation of devitalized constructs in contralateral control chambers. The application of an intermittent cyclic mechanical load was found to increase the bone volume fraction of the chamber tissue from 0.4 to 3.6% as compared with no-load control biopsies. The results of these experiments demonstrate that tissue-engineered cartilage constructs implanted into a well-vascularized bone defect will support direct appositional bone formation and that bone formation is significantly influenced by the viability of chondrocytes within the constructs and the local mechanical environment in vivo.

Animals↗

Three-dimensional quantitation of periradicular bone destruction by micro-computed tomography.

We have previously shown that two-dimensional, high-resolution, micro-computed tomography is a rapid, reproducible, and noninvasive method for measuring periradicular bone resorption in mice, giving results virtually identical to histology. In this study, we determined whether a three-dimensional volumetric quantitation of bone resorption could be achieved and whether this correlates with two-dimensional measurements. Periradicular lesions were induced in the lower first molars of mice by pulp exposure and infection; unexposed teeth served as controls. Mandibles were harvested on day 21 and subjected to: (a) three-dimensional micro-computed tomography imaging; and (b) conventional histology. Using a three-dimensional model and a semiautomatic contouring algorithm, we determined three-dimensional void volume, void surface, void thickness, and the standard deviation of the thickness distribution. The results showed a significant correlation between lesion void volume and two-dimensional lesion area by histology (r2 = 0.73), as well as high correlations between void volume and void thickness (r2 = 0.86) and standard deviation of the void thickness (r2 = 0.87), but no relationship with void surface. These results show that three-dimensional analysis of micro-computed tomography images is highly correlated with two-dimensional cross-sectional measures of periradicular lesions. Nevertheless, micro-computed tomography allows assessment of additional microstructural features as well as sub-regional analysis of lesion development.

Algorithms↗

Adaptations of trabecular bone to low magnitude vibrations result in more uniform stress and strain under load.

Extremely low magnitude mechanical stimuli (<10 microstrain) induced at high frequencies are anabolic to trabecular bone. Here, we used finite element (FE) modeling to investigate the mechanical implications of a one year mechanical intervention. Adult female sheep stood with their hindlimbs either on a vibrating plate (30 Hz, 0.3 g) for 20 min/d, 5 d/wk or on an inactive plate. Microcomputed tomography data of 1 cm bone cubes extracted from the medial femoral condyles were transformed into FE meshes. Simulated compressive loads applied to the trabecular meshes in the three orthogonal directions indicated that the low level mechanical intervention significantly increased the apparent trabecular tissue stiffness of the femoral condyle in the longitudinal (+17%, p<0.02), anterior-posterior (+29%, p<0.01), and medial-lateral (+37%, p<0.01) direction, thus reducing apparent strain magnitudes for a given applied load. For a given apparent input strain (or stress), the resultant stresses and strains within trabeculae were more uniformly distributed in the off-axis loading directions in cubes of mechanically loaded sheep. These data suggest that trabecular bone responds to low level mechanical loads with intricate adaptations beyond a simple reduction in apparent strain magnitude, producing a structure that is stiffer and less prone to fracture for a given load.

Adaptation, Physiological↗

Trabecular bone response to mechanical and parathyroid hormone stimulation: the role of mechanical microenvironment.

UNLABELLED: Bone response under combined mechanical and PTH stimuli is important in osteoporosis. A rat tail animal model with computer modeling was used to examine bone response to loading and PTH. PTH enhances and sustains increased bone formation rate, which directly correlates to mechanical microenvironment, suggesting beneficial effects of combined PTH treatment and exercise in preventing osteoporosis. INTRODUCTION: Using an in vivo rat tail vertebra model combined with a specimen-specific, high-resolution microcomputed tomography (microCT)-based finite element analysis (FEA) technique, trabecular bone response to combined dynamic compressive loading and parathyroid hormone (PTH) stimulation was characterized. MATERIALS AND METHODS: Two hundred twenty-four male Sprague-Dawley rats were randomly divided into seven treatment groups: (1) Control, (2) vehicle + 0N, (3) PTH + 0N, (4) vehicle + 50N, (5) PTH + 50N, (6) vehicle + 100N, and (7) PTH + 100N, with three treatment durations (1, 2, or 4 weeks). Rat PTH(1-34) was administered daily in the PTH-stimulated groups approximately 3 h before daily mechanical stimulation with 0, 50, or 100N dynamic compressive loading. microCT-based FEA was performed for each loaded vertebra after death. Bone histomorphometry was performed on trabecular bone with double fluorochrome labeling to assess bone formation. RESULTS: Daily mechanical loading or PTH administration significantly increased bone formation rate (BFR) compared with control or V + 0N with significant increases in both mineral apposition rate (MAR) and labeled bone surface (LS/BS). PTH, when combined with mechanical loading, enhanced BFR mainly through a significant increase in MAR after the first week and through a significant increase in LS/BS after 2 and 4 weeks. Synergistic effects in BFR were present when PTH was combined with mechanical loading, especially after 2 and 4 weeks, where the increase in BFR was sustained. However, when either PTH or mechanical loading was the only stimulus, the bone formation response diminished to the level of Control animals after 4 weeks. Furthermore, significant correlations were observed between the bone formation indices and trabecular bone tissue mechanical microenvironments at 1 and 2 weeks, with PTH administration enhancing and sustaining these correlations into 4 weeks. CONCLUSIONS: The synergistic effects of combined PTH and mechanical stimulation on trabecular bone formation rate suggest a potential benefit for combined PTH administration and exercise in the treatment of osteoporosis.

Animals↗

Can novel clinical densitometric techniques replace or improve DXA in predicting bone strength in osteoporosis at the hip and other skeletal sites?

New peripheral techniques are now available for the diagnosis of osteoporosis, but their value in the clinical management of the disease remains controversial. This study tests the hypothesis that peripheral quantitative computed tomography (pQCT) at the distal radius and/or quantitative ultrasound (QUS) at the calcaneus can serve as replacement or improvement of current methodology (QCT and DXA) for predicting bone strength at the hip and other sites. In 126 human cadavers (age, 80.2 +/- 10.4 years), DXA of the femur, spine, and radius and pQCT of the radius were acquired with intact soft tissues. QCT (spine) and QUS (calcaneus) were performed ex situ in degassed specimens. Femoral failure loads were assessed in side impact and vertical loading. Failure loads of the thoracolumbar spine were determined at three levels in compression and those of the radius by simulating a fall. Site-specific DXA explained approximately 55% of the variability in femoral strength, whereas pQCT and QUS displayed a lower association (15-40%). QUS did not provide additional information on mechanical strength of the femur, spine, or radius. All techniques displayed similar capability in predicting a combined index of failure strength at these three sites, with only QUS exhibiting significantly lower associations than other methods. These experimental results suggest that clinical assessment of femoral fracture risk should preferably rely on femoral DXA, whereas DXA, QCT, and pQCT display similar capability of predicting a combined index of mechanical strength at the hip, spine, and radius.

Absorptiometry, Photon↗

Precision and accuracy of peripheral quantitative computed tomography (pQCT) in the mouse skeleton compared with histology and microcomputed tomography (microCT).

UNLABELLED: pQCT was evaluated for accuracy of phenotypic characterization of mouse bone in vivo. Bones (tibia, femur, spine) of 27 animals were measured ex vivo with pQCT, microCT, and histomorphometry and of 23 mice in vivo (pQCT). pQCT yielded satisfactory in vivo precision and accuracy in skeletal characterization. INTRODUCTION: Important aspects of modern skeletal research depend on the phenotypic characterization of genetically manipulated mice, with some approaches requiring in vivo measurement. Peripheral quantitative computed tomography (pQCT) is applicable in vivo and provides opportunities to determine a large variety of bone parameters. Here we test the ex vivo and in vivo reproducibility of pQCT, and its accuracy in comparison with histomorphometry and microcomputed tomography (microCT). MATERIALS AND METHODS: We examined the tibia, femur, and lumbar spine of 27 mice ex vivo with high-resolution pQCT, using two mouse models (wild-type and ob/ob) with known differences in bone density. Measurements were repeated three times at different days in nine animals. In a second experiment, 23 animals (10 wild-type and 13 bGH transgenic mice) were repeatedly measured in vivo at 12 and 13 weeks of age, respectively. RESULTS: Among metaphyseal sites, the ex vivo precision was highest at the distal femur (RMS CV < 1% for density and < 2% for area). The correlation between density (pQCT) and bone volume fraction (histomorphometry) was r2 = 0.79 (tibia, femur, and spine), and that with microCT was r2 = 0.94 (femur). At the diaphysis, the precision was highest at the femur (< 2% for total and cortical area), and the correlation with microCT was r2 > 0.77. The in vivo precision for bone density (distal femur) was 2.3-5.1%, and that for absolute and relative cortical area (tibia) was 3.1% and 2.2%. CONCLUSIONS: The results show that pQCT can yield satisfactory precision and accuracy in skeletal characterization of mouse bones, if properly applied. The potential advantage of pQCT is that it provides a large set of parameters on bone properties and that it can be used in vivo, extending the available methodological repertoire for genetic studies.

Animals↗

A comparison of the femoral head and neck trabecular architecture of Galago and Perodicticus using micro-computed tomography (microCT).

Innovations in micro-computed tomography (microCT) in the medical field have resulted in the development of techniques that allow the precise quantification of bone density and fabric related parameters of trabecular bone. For the purpose of this study, the technique was applied to a small sample of Perodicticus potto and Galago senegalensis femora to see if differences in loading environment elicit the predicted effects on trabecular structure. While the overall bone volume was approximately three times larger in the potto, there was no significant difference in the apparent volume density in the two taxa. When regional differences in the proximal femur were examined, the cancellous bone of the femoral head of Perodicticus potto and Galago senegalensis, while not differing in volume density, showed differences in trabecular orientation, with the potto having more randomly oriented trabeculae than the bushbaby. This was as hypothesized, given that the bushbaby submits its femora to more stereotypical loading environments than the potto. In the femoral neck, the cancellous bone was not only more randomly oriented, it was also denser in the potto compared with the bushbaby. This suggests that trabecular morphology may be extremely sensitive to certain differences in the loading environment and that this information, combined with information on cortical bone structure and external geometry, will result in a more complete understanding of how bone shape and composition correspond to loading and locomotor patterns. Ultimately, a synthesis of these different lines of evidence may have considerable applications in paleontological studies that attempt to reconstruct bone use from morphology.

Animals↗

Bone strength at clinically relevant sites displays substantial heterogeneity and is best predicted from site-specific bone densitometry.

In this study we test the hypotheses that mechanical bone strength in elderly individuals displays substantial heterogeneity among clinically relevant skeletal sites, that ex situ dual-energy X-ray absorptiometry (DXA) provides better estimates of bone strength than in situ DXA, but that a site-specific approach of bone densitometry is nevertheless superior for optimal prediction of bone failure under in situ conditions. DXA measurements were obtained of the lumbar spine, the left femur, the left radius, and the total body in 110 human cadavers (age, 80.6 +/- 10.5 years; 72 female, 38 male), including the skin and soft tissues. The bones were then excised, spinal and femoral DXA being repeated ex situ. Mechanical failure tests were performed on thoracic vertebra 10 and lumbar vertebra 3 (compressive loading of a functional unit), the left and right femur (side impact and vertical loading configuration), and the left and right distal radius (fall configuration, axial compression, and 3-point-bending). The failure loads displayed only very moderate correlation among sites (r = 0.39 to 0.63). Ex situ DXA displayed slightly higher correlations with failure loads compared with those of in situ DXA, but the differences were not significant and relatively small. Under in situ conditions, DXA predicted 50-60% of the variability in bone failure loads at identical (or closely adjacent) sites, but only around 20-35% at distant sites, advocating a site-specific approach of densitometry. These data suggest that mechanical competence in the elderly is governed by strong regional variation, and that its loss in osteoporosis may not represent a strictly systemic process.

Absorptiometry, Photon↗

Quantity and quality of trabecular bone in the femur are enhanced by a strongly anabolic, noninvasive mechanical intervention.

The skeleton's sensitivity to mechanical stimuli represents a critical determinant of bone mass and morphology. We have proposed that the extremely low level (< 10 microstrain), high frequency (20-50 Hz) mechanical strains, continually present during even subtle activities such as standing are as important to defining the skeleton as the larger strains typically associated with vigorous activity (>2000 microstrain). If these low-level strains are indeed anabolic, then this sensitivity could serve as the basis for a biomechanically based intervention for osteoporosis. To evaluate this hypothesis, the hindlimbs of adult female sheep were stimulated for 20 minutes/day using a noninvasive 0.3g vertical oscillation sufficient to induce approximately 5 microstrain on the cortex of the tibia. After 1 year of stimulation, the physical properties of 10-mm cubes of trabecular bone from the distal femoral condyle of experimental animals (n = 8) were compared with controls (n = 9), as evaluated using microcomputed tomography (microCT) scanning and materials testing. Bone mineral content (BMC) was 10.6% greater (p < 0.05), and the trabecular number (Tb.N) was 8.3% higher in the experimental animals (p < 0.01), and trabecular spacing decreased by 11.3% (p < 0.01), indicating that bone quantity was increased both by the creation of new trabeculae and the thickening of existing trabeculae. The trabecular bone pattern factor (TBPf) decreased 24.2% (p < 0.03), indicating trabecular morphology adapting from rod shape to plate shape. Significant increases in stiffness and strength were observed in the longitudinal direction (12.1% and 26.7%, respectively; both, p < 0.05), indicating that the adaptation occurred primarily in the plane of weightbearing. These results show that extremely low level mechanical stimuli improve both the quantity and the quality of trabecular bone. That these deformations are several orders of magnitude below those peak strains which arise during vigorous activity indicates that this biomechanically based signal may serve as an effective intervention for osteoporosis.

Animals↗

Mechanical and architectural bone adaptation in early stage experimental osteoarthritis.

The purpose of this study was to quantify mechanical and architectural changes to knee joint periarticular subchondral cancellous bone in early stage experimental osteoarthritis (OA). Unilateral anterior cruciate ligament transection (ACLX) was performed on 10 dogs that were assigned randomly to two groups: 3 weeks or 12 weeks post-ACLX. Cylindrical bone cores excised from the medial condyle of the distal femur after death were scanned using high-resolution microcomputed tomography (muCT) and subsequently failed under unconstrained uniaxial compression. The apparent-level elastic modulus was less in the ACLX femur compared with the contralateral control, and the decrease was significant (-45%; p < 0.05) by 12-weeks post-ACLX. A finite element (FE) analysis based on muCT data simulated the uniaxial compression tests on a specimen-by-specimen basis to determine tissue modulus. No change in tissue modulus was detected, and a single tissue modulus of 5100 MPa (95% CI, +/- 600 MPa) explained the apparent-level modulus changes observed in the disease-related bone adaptation. The three-dimensional (3D) connectivity was evaluated from the original muCT data to quantify architectural alterations in contrast to tissue alterations. Significantly increased connectivity (through plate perforations) occurred as early as 3 weeks post-ACLX and was as high as 127% by 12 weeks post-ACLX in the distal femur. These measured changes indicated that architectural adaptation predominated over tissue modulus changes affecting apparent-level elastic modulus in the early stage of experimental OA and suggests that to maintain normal cancellous bone after a traumatic injury, early intervention should focus on preventing the substantial architectural alterations.

Adaptation, Physiological↗

Endoscopic cellular microscopy for in vivo biomechanical assessment of tendon function.

This study explores a novel method to quantify in vivo soft tissue biomechanics from endoscopic confocal fluorescence microscope images of externally loaded biological tissues. A custom algorithm based on normalized cross-correlation is used to track fluorescently labeled cells within soft tissue structures as they deform. Cellular displacements are subsequently reduced to tissue strains by deriving the spatial gradient of the spline smoothed cellular displacement field. The relative performance of the tracking method is verified using a synthetic dataset with known underlying deformation. In biological application of the method, tissue strains are measured in the Achilles tendon of an anesthetized mouse. Over repeated trials, structural strain in the tendon (i.e., the relative change in distance between cells located at view field extremes) is 20.3+/-3.1%, thus establishing the reproducibility of the loading protocol. Analysis of local tendon tissue strains reveal primary engineering strains in the tissue to range from 5 to 55%, signifying a highly inhomogeneous strain state, with complex relative motions of neighboring tendon substructures. In summary, the current work establishes a baseline for a promising experimental method, and demonstrates its technical feasibility.

Animals↗