PubMed Health⌕ Search

Biomedical subjects

Ralph V Clayman

Publications and source records attributed to Ralph V Clayman.

128 records · Page 8Linked to original sources

Acucise endopyelotomy in a porcine model: procedure standardization and analysis of safety and immediate efficacy.

PURPOSE: The study here presented was done to test the technical reliability and immediate efficacy of the Acucise device using a standardized technique. MATERIALS AND METHODS: 56 Acucise procedures were performed in pigs by a single surgeon who used a standardized technique: insert 5F angiographic catheter bilaterally up to the midureter, perform retrograde pyelogram, Amplatz super-stiff guidewire is advanced up to the level of the renal pelvis, angiographic catheters are removed, Acucise catheter balloon is advanced to the ureteropelvic junction (UPJ) level, the super-stiff guide-wire is removed and the contrast medium in the renal pelvis is aspirated and replaced with distilled water, activate Acucise at 75 watts of pure cutting current, keep the balloon fully inflated for 10 minutes, perform retrograde ureteropyelogram to document extravasation, remove Acucise catheter and pass an ureteral stent and remove guide-wire. RESULTS: In no case did the Acucise device present malfunction. The electrocautery activation time was 2.2 seconds (ranging from 2 to 4 seconds). The extravasation of contrast medium, visible by fluoroscopy, occurred in 53 of the 56 cases (94.6%). In no case there was any evidence of intraoperative hemorrhage. CONCLUSIONS: This study revealed that performing Acucise endopyelotomy routinely in a standardized manner could largely preclude intraoperative device malfunction and eliminate complications while achieving a successful incision in the UPJ. With the guidelines that were used in this study, we believe that Acucise endopyelotomy can be completed successfully and safely in the majority of selected patients with UPJ obstruction.

Animals↗

Training and assessment of laparoscopic skills.

Laparoscopic surgery is gaining popularity among the surgical community. While its prevalence expands, the need for reliable training and assessment tools is becoming increasingly important. Laparoscopic skills are not an innate behavior, nor can they be easily mimicked, and can only be acquired through hands-on training. A consensus exists among physicians that establishment and evaluation of technical skill in surgical training programs are inadequate and in need of improvement. A validated, reliable bench model that could train and assess could be standardized and provide numerous benefits including determination of which medical students should consider a career in surgery, valuable feedback to residents, a tracking mechanism of resident performance, a possible certification and recertification tool, and to allow for interinstitutional comparison. To this end, several potentially successful bench models testing dexterity, hand-eye coordination, and depth perception have been developed. A few models have been proven to be both valid and reliable indicators of technical skill. Although the future remains uncertain, enough groundwork has been laid to begin incorporating technical skill training and assessment into surgical training programs.

Clinical Competence↗