PubMed Health⌕ Search

Biomedical subjects

Raluca I Stefan

Publications and source records attributed to Raluca I Stefan.

3 recordsLinked to original sources

Sequential injection spectrophotometric determination of etilefrine hydrochloride.

A simple, fast, economical and automated sequential injection spectrophotometric method for the determination of etilefrine hydrochloride is developed. The method is based on the condensation reaction of etilefrine hydrochloride with 4-aminoantipyrine in the presence of alkaline potassium hexacyanoferrate and the absorbance of the colored product measured at 503 nm. Aspiration order, flow rate, reaction coil diameter, reaction coil length, concentration of 4-aminoantipyrine and potassium ferricyanide, as well as aspiration volume of reagents and sample has been optimized. Using these optimized parameters, a linear relationship between the relative peak height and concentration was obtained in the range 1-20 mg l(-1). The detection limit (as 3sigma value) was 0.1 mg l(-1) and precision was 2.7% and 1.5% at 1 and 2 mg l(-1), respectively. This method is superior over previously reported ones in terms of linear range, short analysis time, high sample throughput, excellent reagent economy and minimum waste generation.

Etilefrine↗

An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid.

An on-line potentiometric sequential injection titration process analyser for the determination of acetic acid is proposed. A solution of 0.1 mol L(-1) sodium chloride is used as carrier. Titration is achieved by aspirating acetic acid samples between two strong base-zone volumes into a holding coil and by channelling the stack of well-defined zones with flow reversal through a reaction coil to a potentiometric sensor where the peak widths were measured. A linear relationship between peak width and logarithm of the acid concentration was obtained in the range 1-9 g/100 mL. Vinegar samples were analysed without any sample pre-treatment. The method has a relative standard deviation of 0.4% with a sample frequency of 28 samples per hour. The results revealed good agreement between the proposed sequential injection and an automated batch titration method.

Acetic Acid↗

New horizons in sequential injection kinetic analysis.

The need to measure several quantities rapidly in the same sample has prompted the development of automated methods of analysis that in both the continuous and discontinuous modes offer the possibility of simultaneous determinations. The application of pH gradients and differential kinetic determinations dominate the simultaneous determination of two or more closely related species in mixtures without prior separation. Various options enable use of kinetic-based measurements for the simultaneous determination of different analytes in flow systems. Some possible general reactions are given and discussed. The scope of sequential injection kinetic analysis is illustrated with examples.

Journal Article↗