PubMed Health⌕ Search

Biomedical subjects

Ram Chuttani

Publications and source records attributed to Ram Chuttani.

18 recordsLinked to original sources

Enteral stents.

Explore the source record for details and available documents.

Current Procedural Terminology↗

Endoluminal instrumentation is changing gastrointestinal surgery.

Advances in endoluminal instrumentation and technology are enabling endoscopists to perform increasingly sophisticated procedures. Indications for these procedures are likely to expand as outcomes studies show they are efficacious and cost-effective. This article highlights several recent advances in endoluminal suturing, dissecting, and ligating and discusses the impact of these advances on the practice of gastrointestinal surgery. Endoluminal suturing offers select patients with gastroesophageal reflux disease a safe and effective alternative to laparoscopic surgery. Devices designed for endoluminal hemostasis and endoscopic mucosal resection can be used effectively for a broader range of applications and are already being used to perform transluminal surgery in animal models; human trials are forthcoming. Gastrointestinal surgeons should support efforts to critically evaluate endoluminal techniques because they have an opportunity to improve care. Surgical residents planning careers in gastrointestinal surgery need to understand endoscopic techniques and consider their training opportunities.

Dissection↗

Analysis of cystic fibrosis gener product (CFTR) function in patients with pancreas divisum and recurrent acute pancreatitis.

BACKGROUND: The mechanism by which pancreas divisum may lead to recurrent episodes of acute pancreatitis in a subset of individuals is unknown. Abnormalities of the cystic fibrosis gene product (CFTR) have been implicated in the genesis of idiopathic chronic pancreatitis. The aim of this study was to determine if CFTR function is abnormal in patients with pancreas divisum and recurrent acute pancreatitis (PD/RAP). METHODS: A total of 69 healthy control subjects, 12 patients with PD/RAP, 16 obligate heterozygotes with a single CFTR mutation, and 95 patients with cystic fibrosis were enrolled. CFTR function was analyzed by nasal transepithelial potential difference testing in vivo. The outcomes of the PD/RAP patients following endoscopic and surgical treatments were concomitantly analyzed. FINDINGS: Direct measurement of CFTR function in nasal epithelium in response to isoproterenol demonstrated that the values for PD/RAP were intermediate between those observed for healthy controls and cystic fibrosis patients. The median value was 13 mV for PD/RAP subjects, which was statistically different from healthy controls (22 mV, p= 0.001) and cystic fibrosis pancreatic sufficient (-1 mV, p < 0.0001) and pancreatic insufficient (-3 mV, p < 0.0001) patients. INTERPRETATIONS: These results suggest a link between CFTR dysfunction and recurrent acute pancreatitis in patients with pancreas divisum and may explain why a subset of patients with pancreas divisum develops recurrent acute pancreatitis.

Acute Disease↗

A novel endoscopic full-thickness plicator for the treatment of GERD: A pilot study.

BACKGROUND: The novel full-thickness plication described in this study was designed to inhibit gastroesophageal reflux by placement of a transmural plication near the gastroesophageal junction under direct endoscopic visualization. The resulting serosa-to-serosa tissue union is thought to accentuate and restore the valvular mechanism of the gastroesophageal junction. The aim of this study was to assess the safety and feasibility of endoscopic full-thickness plication for the treatment of patients with GERD symptoms. METHODS: A pilot study was performed in patients with chronic heartburn and pathologic reflux requiring maintenance antisecretory therapy. A single full-thickness plication was placed in the gastric cardia within 1 to 2 cm of the gastroesophageal junction. The primary end points of the study were procedure safety and feasibility, as well as long-term durability of the full-thickness tissue fixation. Secondary end points included medication use and the GERD-Health Related Quality of Life questionnaire and Gastrointestinal Symptom Rating Scale. RESULTS: Full-thickness plication was performed successfully in 6 of 7 patients, with one procedure aborted because of difficulty in sedating the patient. Mean procedure time was 21 minutes. Mild epigastric pain was reported by two patients and difficulty with eructation by one patient; all symptoms resolved spontaneously within 7 days of the procedure. Endoscopy at 6 months revealed an intact plication in all patients. At 1 year after the procedure, patients reported sustained reduction in heartburn scores. One patient, who did not experience significant relief of symptoms, ultimately underwent successful laparoscopic Nissen fundoplication at 6 months after the procedure. At 1 year after the procedure, 3 of 5 patients were not taking anti-GERD medications. CONCLUSIONS: Endoscopic full-thickness plication is feasible, safe and, in this pilot study, appeared to reduce symptoms and medication use associated with GERD.

Adult↗

Multicenter randomized trial of the spiral Z-stent compared with the Wallstent for malignant biliary obstruction.

BACKGROUND: The industry standard since 1990 for self-expanding biliary metallic stents has been the Wallstent. In 1998 the Spiral Z-stent was released. This randomized trial compared the Z-stent with the Wallstent in the treatment of malignant biliary obstruction. METHODS: Patients with unresectable malignant biliary obstruction distal to the bile duct bifurcation were randomized to receive a 10-mm diameter Wallstent or a 10-mm diameter Z-stent. RESULTS: A total of 145 patients were randomized; 13 were excluded. Sixty-four patients who received a Z-stent and 68 who had a Wallstent are included in the analysis. Tumors responsible for bile duct obstruction were pancreatic cancer (108), cholangiocarcinoma (15), metastatic cancer (6), and papillary cancer (3). Metallic stents were successfully placed in all patients. Seven technical problems were encountered during placement of the Z-stent and 5 with the Wallstent. There were 21 occlusions requiring reintervention (8 Z-stent, 13 Wallstent; p = 0.30). Median time to reintervention was the following: Z-stent, 162 days; Wallstent, 150 days (p = 0.22). A total of 104 patients died of progressive disease or other cause; 7 patients remain alive with patent stents. The overall calculated median patency rates were: Z-stent, 152 days; Wallstent, 154 days (p = 0.90). CONCLUSIONS: The Spiral Z-stent is comparable with the Wallstent in terms of placement, occlusion rates, and overall patency. Occasional early occlusion of both stents suggests tumor characteristics instead of the size of the mesh openings in the stents as important factors.

Aged↗

Endoscopic full-thickness plication: the device, technique, pre-clinical and early clinical experience.

The endoscopic full-thickness plication device is designed to inhibit reflux with a single plication near the gastroesophageal junction. Full-thickness plication of the proximal stomach may improve the competency of the gastroesophageal barrier by restoring the valvular mechanism of the gastroesophageal junction. Other potential mechanisms include alteration of the angle of His, and reduction of the compliance of the gastric cardia and fundus. The procedure is easily and safely performed and, in the human pilot study, has been shown to reduce symptoms and medication use associated with gastroesophageal reflux disease.

Animals↗

A novel endoscopic full-thickness plicator for treatment of GERD: an animal model study.

BACKGROUND: This study was designed to demonstrate the efficacy and safety of a novel endoscopic full-thickness plication device for the treatment of GERD. METHODS: Gastric pressures and reflux from the gastroesophageal junction were measured in 20 excised pig stomachs before and after full-thickness plication within 1 cm of the gastroesophageal junction. Endoscopic full-thickness plication was performed on 11 live mini-swine that were subsequently observed for up to 12 weeks. OBSERVATIONS: Full-thickness plication significantly increased the mean intragastric pressure at which gastroesophageal reflux occurred. No complication, death, or sign of infection or tissue damage was noted by endoscopic observation or inspection of excised tissue at up to 12 weeks' follow-up. CONCLUSIONS: These studies in the ex vivo porcine model and live pigs suggest that full-thickness plication is effective and safe.

Animals↗

Intraductal US is a useful adjunct to ERCP for distinguishing malignant from benign biliary strictures.

BACKGROUND: Distinguishing malignant from benign biliary strictures remains a challenge. This prospective study assessed intraductal US as an adjunct to endoscopic retrograde cholangiography and tissue sampling for diagnosis of malignant and benign biliary strictures. METHODS: Sixty-two patients were enrolled who had biliary strictures suspected to be malignant but with negative tissue sampling by endoscopic retrograde cholangiography, or suspected biliary strictures based on clinical manifestations and/or cross-sectional imaging. Intraductal US was performed with an over-the-wire 2.4-mm diameter 20 MHz catheter US probe. The diagnostic accuracy of endoscopic retrograde cholangiography plus tissue sampling with and without intraductal US was compared with surgical findings or clinical outcome at a 12-month follow-up (benign/malignant) in nonsurgical cases. Tissue sampling results were reported as malignant, suspicious for malignancy, atypical, or normal. Analysis was by intention-to-treat. RESULTS: Two patients (3%) were excluded from analysis because the stricture could not be traversed with the intraductal US probe. Of the 60 remaining patients (37 men, mean age 64 years, range 27-89 years), 31 had malignant strictures (12 cholangiocarcinoma, 8 pancreatic, 5 metastatic, 3 gallbladder, 3 papilla), and 29 had benign strictures. Sphincterotomy was not required in any case to facilitate intraductal US. Fourteen patients (23%) underwent subsequent surgery including 11 with a preoperative diagnosis of resectable tumor. Endoscopic retrograde cholangiography/tissue sampling (atypia considered equivalent to benign) correctly identified 15 of 31 malignant strictures (p = 0.001) and all 29 benign strictures (p = 0.16) (accuracy 73%, sensitivity 48%, specificity 100%). The addition of intraductal US correctly identified 28 of 31 malignant strictures and 27 of 29 benign strictures (accuracy 92%, sensitivity 90%, specificity 93%). Of 11 patients with tumors who came to surgery, intraductal US correctly staged 4 (36%), understaged 5 (45%), missing metastatic lymph nodes in all cases and vascular invasion in 1 patient, and overstaged 2 (18%), with a false-positive diagnosis of metastatic lymph nodes in 1 and tumor mass in 1 patient who had no cancer at surgery. CONCLUSION: Technically easy, intraductal US is a valuable adjunct to endoscopic retrograde cholangiography/tissue sampling that increases the ability to distinguish malignant from benign strictures. Intraductal US is unsuitable for assessing lymph nodes associated with malignant strictures.

Adult↗