PubMed Health⌕ Search

Biomedical subjects

Ramandeep Brar

Publications and source records attributed to Ramandeep Brar.

4 recordsLinked to original sources

Alterations in ion channel physiology in diabetic cardiomyopathy.

Diabetes mellitus is one of the most common chronic illnesses worldwide. This article focuses on a subgroup of diabetic patients with a specific cardiac complication of this disease--diabetic cardiomyopathy. This article initially gives some general background on diabetic cardiomyopathy and ion channels. Next the focus is on how diabetic cardiomyopathy alters calcium homeostasis in cardiac myocytes and highlights the specific alterations in ion channel function that are characteristic of this type of cardiomyopathy. Finally, the importance of the renin-angiotensin system in diabetic cardiomyopathy is reviewed.

Animals↗

Left ventricular lead stabilization utilizing a coronary stent.

Cardiac resynchronization therapy has been recently demonstrated to have a mortality and morbidity benefit in heart failure (HF) patients with cardiac dyssynchrony. Currently, the most widely used method of left ventricular (LV) lead placement involves transvenous placement of leads via the coronary sinus (CS) and into a tributary branch. Lead dislodgement is a common cause for reoperation, and continues to be a common problem despite advances in equipment and operator techniques. We describe a case where a coronary stent was placed in a lateral branch of the CS to stabilize the lead against the vessel wall.

Aged↗

Continuous recording of pulmonary artery diastolic pressure and cardiac output using a novel ultrasound transducer.

BACKGROUND: The feasibility of hands-free transthoracic continuous determination of pulmonary artery (PA) diastolic pressure (PAD) and cardiac output (CO) by Doppler ultrasound has not been previously demonstrated. We developed a 2.5-MHz spherical transducer mounted in an external housing to permit steering in 360 degrees (Contison). The external housing was attached to the chest wall using an adhesive patch. METHODS AND RESULTS: Fifty patients in the coronary care department who had PA catheters had Doppler ultrasound studies. The 2.5-MHz spherical transducer was placed at the left sternal border to permit imaging of the pulmonic valve and was attached to a commercial ultrasound machine. The PA was imaged and its diameter measured. The pulmonary flow velocity signal was recorded and the time velocity integral obtained. The CO was calculated as: CO = time velocity integral of the PA systolic flow velocity signal x pi diameter(2) divided by 4 x heart rate. The pulmonary regurgitation signal was then recorded and the end-diastolic velocity of the regurgitant signal was measured. Right atrial pressure was assessed from the jugular venous pressure or from the size and pulsatility of the inferior vena cava. The PADP was calculated as: PADP = 4 end-diastolic velocity of the regurgitant signal(2) + right atrial pressure. The CO, PADP, and pulmonary wedge pressure were recorded from the PA catheter immediately after the ultrasound studies. Serial data were obtained every half hour or 1 hour up to a maximum of 5 hours. Adequate Doppler signals were obtained in 43 patients. RESULTS: There was a good correlation between the PADP by Doppler versus PA catheter (r = 0.90, standard error of the estimate = 3.3 mm Hg); PADP by Doppler versus PA wedge pressure (r = 0.88, standard error of the estimate = 3.7 mm Hg); and CO by Doppler versus PA catheter (r = 0.92, standard error of the estimate = 0.7 L/min). CONCLUSION: The 2.5-MHz spherical transducer permitted accurate assessment of CO and PAD. This transducer could be of potential value in monitoring patients in the intensive care setting.

Adult↗