The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups--finite element simulations and experimental tests.

BACKGROUND: Contact pressure of UHMWPE acetabular cup has been shown to correlate with wear in total hip replacement (THR). The aim of the present study was to test the hypotheses that the cup geometry, abduction angle, thickness and clearance can modify the stresses in cemented polyethylene cups. METHODS: Acetabular cups with different geometries (Link: IP and Lubinus eccentric) were tested cyclically in a simulator at 45 degrees and 60 degrees abduction angles. Finite element (FE) meshes were generated and two additional designs were reconstructed to test the effects of the cup clearance and thickness. Contact pressures at cup-head and cup-cement interfaces were calculated as a function of loading force at 45 degrees, 60 degrees and 80 degrees abduction angles. RESULTS: At the cup-head interface, IP experienced lower contact pressures than the Lubinus eccentric at low loading forces. However, at higher loading forces, much higher contact pressures were produced on the surface of IP cup. An increase in the abduction angle increased contact pressure in the IP model, but this did not occur to any major extent with the Lubinus eccentric model. At the cup-cement interface, IP experienced lower contact pressures. Increased clearance between cup and head increased contact pressure both at cup-head and cup-cement interfaces, whereas a decreased thickness of polyethylene layer increased contact pressure only at the cup-cement interface. FE results were consistent with experimental tests and acetabular cup deformations. CONCLUSION: FE analyses showed that geometrical design, thickness and abduction angle of the acetabular cup, as well as the clearance between the cup and head do change significantly the mechanical stresses experienced by a cemented UHMWPE acetabular cup. These factors should be taken into account in future development of THR prostheses. FE technique is a useful tool with which to address these issues.

Acetabulum↗

Improvement of arthroscopic cartilage stiffness probe using amorphous diamond coating.

During arthroscopic evaluation of articular cartilage unstable contact and even slipping of the measurement instrument on the tissue surface may degrade the reproducibility of the measurement. The main aim of the present study was to achieve more stable contact by controlling the friction between articular cartilage surface and the arthroscopic cartilage stiffness probe (Artscan 200, Artscan Oy, Helsinki, Finland) using amorphous diamond (AD) coating. In order to obtain surfaces with different average roughnesses (R(a)), polished stainless steel disks were coated with AD by using the filtered pulsed arc-discharge (FPAD) method. Dynamic coefficient of friction (mu) between the articular cartilage (n = 8) and the coated plates along one non-coated plate was then determined. The friction between AD and cartilage could be controlled over a wide range (mu = 0.027-0.728, p < 0.05, Wilcoxon test) by altering the roughness. Possible deterioration of cartilage was investigated by measuring surface roughness after friction tests and comparing it with the roughness of the adjacent, untested samples (n = 8). Importantly, even testing with the roughest AD (R(a) = 1250 nm) did not damage articular surface. On the basis of the friction measurements, a proper AD coating was selected for the stiffness probe. The performance of coated and non-coated probe was compared by measuring bovine osteochondral samples (n = 22) with both instruments. The reproducibility of the stiffness measurements was significantly better with the AD-coated probe (CV% = 4.7) than with the uncoated probe (CV% = 8.2). To conclude, AD coating can be used to safely control dynamic friction with articular surface. Sufficient friction between articular surface and reference plate of the arthroscopic probe improves significantly reproducibility of the stiffness measurements.

Animals↗

Mechano-acoustic determination of Young's modulus of articular cartilage.

The compressive stiffness of an elastic material is traditionally characterized by its Young's modulus. Young's modulus of articular cartilage can be directly measured using unconfined compression geometry by assuming the cartilage to be homogeneous and isotropic. In isotropic materials, Young's modulus can also be determined acoustically by the measurement of sound speed and density of the material. In the present study, acoustic and mechanical techniques, feasible for in vivo measurements, were investigated to quantify the static and dynamic compressive stiffness of bovine articular cartilage in situ. Ultrasound reflection from the cartilage surface, as well as the dynamic modulus were determined with the recently developed ultrasound indentation instrument and compared with the reference mechanical and ultrasound speed measurements in unconfined compression (n=72). In addition, the applicability of manual creep measurements with the ultrasound indentation instrument was evaluated both experimentally and numerically. Our experimental results indicated that the sound speed could predict 47% and 53% of the variation in the Young's modulus and dynamic modulus of cartilage, respectively. The dynamic modulus, as determined manually with the ultrasound indentation instrument, showed significant linear correlations with the reference Young's modulus (r(2)=0.445, p<0.01, n=70) and dynamic modulus (r(2)=0.779, p<0.01, n=70) of the cartilage. Numerical analyses indicated that the creep measurements, conducted manually with the ultrasound indentation instrument, were sensitive to changes in Young's modulus and permeability of the tissue, and were significantly influenced by the tissue thickness. We conclude that acoustic parameters, i.e. ultrasound speed and reflection, are indicative to the intrinsic mechanical properties of the articular cartilage. Ultrasound indentation instrument, when further developed, provides an applicable tool for the in vivo detection of cartilage mechano-acoustic properties. These techniques could promote the diagnostics of osteoarthrosis.

Animals↗

Experimental and numerical validation for the novel configuration of an arthroscopic indentation instrument.

Softening of articular cartilage, mainly attributable to deterioration of superficial collagen network and depletion of proteoglycans, is a sign of incipient osteoarthrosis. Early diagnosis of osteoarthrosis is essential to prevent the further destruction of the tissue. During the past decade, a few arthroscopic instruments have been introduced for the measurement of cartilage stiffness; these can be used to provide a sensitive measure of cartilage status. Ease of use, accuracy and reproducibility of the measurements as well as a low risk of damaging cartilage are the main qualities needed in any clinically applicable instrument. In this study, we have modified a commercially available arthroscopic indentation instrument to better fulfil these requirements when measuring cartilage stiffness in joints with thin cartilage. Our novel configuration was validated by experimental testing as well as by finite element (FE) modelling. Experimental and numerical tests indicated that it would be better to use a smaller reference plate and a lower pressing force (3 N) than those used in the original instrument (7-10 N). The reproducibility (CV = 5.0%) of the in situ indentation measurements was improved over that of the original instrument (CV = 7.6%), and the effect of material thickness on the indentation response was smaller than that obtained with the original instrument. The novel configuration showed a significant linear correlation between the indenter force and the reference dynamic modulus of cartilage in uncontined compression, especially in soft tissue (r = 0.893, p < 0.001, n = 16). FE analyses with a transversely isotropic poroelastic model indicated that the instrument was suitable for detecting the degeneration of superficial cartilage. In summary, the instrument presented in this study allows easy and reproducible measurement of cartilage stiffness, also in thin cartilage, and therefore represents a technical improvement for the early diagnosis of osteoarthrosis during arthroscopy.

Animals↗

Fibril reinforced poroelastic model predicts specifically mechanical behavior of normal, proteoglycan depleted and collagen degraded articular cartilage.

Degradation of collagen network and proteoglycan (PG) macromolecules are signs of articular cartilage degeneration. These changes impair cartilage mechanical function. Effects of collagen degradation and PG depletion on the time-dependent mechanical behavior of cartilage are different. In this study, numerical analyses, which take the compression-tension nonlinearity of the tissue into account, were carried out using a fibril reinforced poroelastic finite element model. The study aimed at improving our understanding of the stress-relaxation behavior of normal and degenerated cartilage in unconfined compression. PG and collagen degradations were simulated by decreasing the Young's modulus of the drained porous (nonfibrillar) matrix and the fibril network, respectively. Numerical analyses were compared to results from experimental tests with chondroitinase ABC (PG depletion) or collagenase (collagen degradation) digested samples. Fibril reinforced poroelastic model predicted the experimental behavior of cartilage after chondroitinase ABC digestion by a major decrease of the drained porous matrix modulus (-64+/-28%) and a minor decrease of the fibril network modulus (-11+/-9%). After collagenase digestion, in contrast, the numerical analyses predicted the experimental behavior of cartilage by a major decrease of the fibril network modulus (-69+/-5%) and a decrease of the drained porous matrix modulus (-44+/-18%). The reduction of the drained porous matrix modulus after collagenase digestion was consistent with the microscopically observed secondary PG loss from the tissue. The present results indicate that the fibril reinforced poroelastic model is able to predict specifically characteristic alterations in the stress-relaxation behavior of cartilage after enzymatic modifications of the tissue. We conclude that the compression-tension nonlinearity of the tissue is needed to capture realistically the mechanical behavior of normal and degenerated articular cartilage.

Animals↗

Ultrasound indentation of bovine knee articular cartilage in situ.

We have earlier developed a handheld ultrasound indentation instrument for the diagnosis of articular cartilage degeneration. In ultrasound indentation, cartilage is compressed with the ultrasound transducer. Tissue thickness and deformation are calculated from the A-mode ultrasound signal and the stress applied is registered with the strain gauges. In this study, the applicability of the ultrasound indentation instrument to quantify site-dependent variation in the mechano-acoustic properties of bovine knee cartilage was investigated. Osteochondral blocks (n=6 per site) were prepared from the femoral medial condyle (FMC), the lateral facet of the patello-femoral groove (LPG) and the medial tibial plateau (MTP). Cartilage stiffness (dynamic modulus, E(dyn)), as obtained with the ultrasound indentation instrument in situ, correlated highly linearly (r=0.913, p<0.01) with the values obtained using the reference material-testing device in vitro. Reproducibility (standardized coefficient of variation) of the ultrasound indentation measurements was 5.2%, 1.7% and 3.1% for E(dyn), ultrasound reflection coefficient of articular surface (R) and thickness, respectively. E(dyn) and R were site dependent (p<0.05, Kruskall-Wallis H test). E(dyn) was significantly higher (p<0.05, Kruskall-Wallis Post Hoc test) in LPG (mean+/-SD: 10.1+/-3.1MPa) than in MTP (2.9+/-1.4MPa). In FMC, E(dyn) was 4.6+/-1.3MPa. R was significantly (p<0.05) lower at MTP (2.0+/-0.7%) than at other sites (FMC: 4.2+/-0.9%; LPG: 4.4+/-0.8%). Cartilage glycosaminoglycan concentration, as quantified with the digital densitometry, correlated positively with E(dyn) (r=0.678, p<0.01) and especially with the equilibrium Young's modulus (reference device, r=0.874, p<0.01) but it was not associated with R (r=0.294, p=0.24). We conclude that manual measurements are reproducible and the instrument may be used for detection of cartilage quality in situ. Especially, combined measurement of thickness, E(dyn) and R provides valuable diagnostic information on cartilage status.

Animals↗

Structure-function relationships in enzymatically modified articular cartilage.

The present study is aimed at revealing structure-function relationships of bovine patellar articular cartilage. Collagenase, chondroitinase ABC and elastase were used for controlled and selective enzymatic modifications of cartilage structure, composition and functional properties. The effects of the enzymatic degradations were quantitatively evaluated using quantitative polarized light microscopy, digital densitometry of safranin O-stained sections as well as with biochemical and biomechanical techniques. The parameters related to tissue composition and structure were correlated with the indentation stiffness of cartilage. In general, tissue alterations after enzymatic digestions were restricted to the superficial cartilage. All enzymatic degradations induced superficial proteoglycan (PG) depletion. Collagenase also induced detectable superficial collagen damage, though without causing cartilage fibrillation or tissue swelling. Quantitative microscopic techniques were more sensitive than biochemical methods in detecting these changes. The Young's modulus of cartilage decreased after enzymatic treatments indicating significant softening of the tissue. The PG concentration of the superficial zone proved to be the major determinant of the Young's modulus (r(2) = 0.767, n = 72, p < 0.001). Results of the present study indicate that specific enzymatic degradations of the tissue PGs and collagen can provide reproducible experimental models to clarify the structure-function relationships of cartilage. Effects of these models mimic the changes observed in early osteoarthrosis. Biomechanical testing and quantitative microscopic techniques proved to be powerful tools for detecting the superficial structural and compositional changes while the biochemical measurements on the whole uncalcified cartilage were less sensitive.

Animals↗