Automatic intraaortic balloon pump timing using an intrabeat dicrotic notch prediction algorithm.

PURPOSE: The efficacy of intraaortic balloon counterpulsation (IABP) during arrhythmic episodes is questionable. A novel algorithm for intrabeat prediction of the dicrotic notch was used for real time IABP inflation timing control. DESCRIPTION: A windkessel model algorithm was used to calculate real-time aortic flow from aortic pressure. The dicrotic notch was predicted using a percentage of calculated peak flow. Automatic inflation timing was set at intrabeat predicted dicrotic notch and was combined with automatic IAB deflation. EVALUATION: Prophylactic IABP was applied in 27 patients with low ejection fraction (< 35%) undergoing cardiac surgery. Analysis of IABP at a 1:4 ratio revealed that IAB inflation occurred at a mean of 0.6 +/- 5 ms from the dicrotic notch. In all patients accurate automatic timing at a 1:1 assist ratio was performed. Seventeen patients had episodes of severe arrhythmia, the novel IABP inflation algorithm accurately assisted 318 of 320 arrhythmic beats at a 1:1 ratio. CONCLUSIONS: The novel real-time intrabeat IABP inflation timing algorithm performed accurately in all patients during both regular rhythms and severe arrhythmia, allowing fully automatic intrabeat IABP timing.

Aged↗

Performance of a real-time dicrotic notch detection and prediction algorithm in arrhythmic human aortic pressure signals.

A novel algorithm for real-time detection and prediction of the dicrotic notch from aortic pressure waves was evaluated in arrhythmic aortic pressure signals from heart failure patients. A simplified model of the arterial tree was used to calculate real-time aortic flow from aortic pressure. The dicrotic notch was detected at the first negative dip from the calculated flow, prediction of the notch was performed using a percentage of the decreasing flow. The performance of the real-time dicrotic notch detection algorithm (RTDND) was evaluated during severe arrhythmia from aortic pressure signals of 12 patients. The RTDND was able to detect the dicrotic notch in 98.1%. No false positive dicrotic notch identifications were observed. Prediction of the dicrotic notch was tested at 40%, 20%, and 0% of the decreasing calculated aortic flow. The mean time-delays to the notch were 68 +/- 14 ms, 55 +/- 12 ms, and 43 +/- 8 ms, respectively. Given these small variability, intra-beat prediction of the dicrotic notch may be used for real-time intra-aortic balloon counterpulsation inflation timing.

Aged↗