PubMed Health⌕ Search

Biomedical subjects

Raoul S Pereira

Publications and source records attributed to Raoul S Pereira.

2 recordsLinked to original sources

A comparison of images generated from diffusion-weighted and diffusion-tensor imaging data in hyper-acute stroke.

PURPOSE: To compare isotropic (combined diffusion-weighted image [CMB], apparent diffusion coefficient [ADC], TRACE, exponential ADC [eADC], and isotropically-weighted diffusion image [isoDWI]) and anisotropic (relative anisotropy [RA], fractional anisotropy [FA], and volume ratio [VR]) diffusion images collected with fast magnetic resonance (MR) diffusion-weighted (DWI) and diffusion-tensor (DTI) acquisition strategies (each less than one minute) in hyper-acute stroke. MATERIALS AND METHODS: Twenty-one patients suffering from ischemic stroke-imaged within six hours of symptom onset using both DWI and DTI-were analyzed. Regions of interest were placed in the ischemic lesion and in normal contralateral tissue and the percent difference in image intensity was calculated for all nine generated images. RESULTS: The average absolute percent changes for the isotropic strategies were all > 38%, with isoDWI found to have a difference of 50.7% +/- 7.9% (mean +/- standard error, P < 0.001). The ADC maps had the most significant difference (-42.4% +/- 2.0%, P < 0.001, coefficient of variation = 0.22). No anisotropic images had significant differences. CONCLUSION: Anisotropic maps do not consistently show changes in the first six hours of ischemic stroke; therefore, isotropic maps, such as those obtained using DWI, are more appropriate for detecting hyper-acute stroke. Anisotropic images, however, may be useful to differentiate hyper-acute stroke from acute and sub-acute stroke.

Aged↗

Effect of b value on contrast during diffusion-weighted magnetic resonance imaging assessment of acute ischemic stroke.

PURPOSE: To examine the effect of varying the diffusion encoding strength (b value) on the contrast (signal difference, Delta S) between damaged and normal tissue during diffusion-weighted magnetic resonance imaging (DWI) assessment of acute ischemic stroke. MATERIALS AND METHODS: Phantoms with diffusion values approximating those expected in acutely infarcted and normal tissue were constructed from a mixture of agar and formaldehyde and imaged at varying b values (0-3000 mm(-2) second). Ten patients were imaged with multiple b values (500-2500 mm(-2) second) within 12 hours of stroke onset. RESULTS: Theoretical calculations showed that for any combination of diffusion coefficients there existed an optimal b value that was higher than the standard setting of 1000 mm(-2) second, and this was confirmed by the phantom studies. In the patients, increasing b from 1000 to 1500 mm(-2) second increased Delta S (average, 22.4%; P = 0.001), but no consistent benefit was seen at b = 2000 mm(-2) second (P = 0.408). This compared favorably with the average optimal b value of 1662 mm(- 2) second calculated from the patients. CONCLUSION: These results suggest that increasing the b value from 1000 to 1500 mm(-2) second would increase contrast between infarcted and normal tissue in the setting of acute ischemic stroke.

Acute Disease↗