Annular-ring CMUT arrays for forward-looking IVUS: transducer characterization and imaging.

In this study, a 64-element, 1.15-mm diameter annular-ring capacitive micromachined ultrasonic transducer (CMUT) array was characterized and used for forward-looking intravascular ultrasound (IVUS) imaging tests. The array was manufactured using low-temperature processes suitable for CMOS electronics integration on a single chip. The measured radiation pattern of a 43 X 140-microm2 array element depicts a 40 degrees view angle for forward-looking imaging around a 15-MHz center frequency in agreement with theoretical models. Pulse-echo measurements show a -10-dB fractional bandwidth of 104% around 17 MHz for wire targets 2.5 mm away from the array in vegetable oil. For imaging and SNR measurements, RF A-scan data sets from various targets were collected using an interconnect scheme forming a 32-element array configuration. An experimental point spread function was obtained and compared with simulated and theoretical array responses, showing good agreement. Therefore, this study demonstrates that annular-ring CMUT arrays fabricated with CMOS-compatible processes are capable of forward-looking IVUS imaging, and the developed modeling tools can be used to design improved IVUS imaging arrays.

Equipment Design↗

CMUTS with dual-electrode structure for improved transmit and receive performance.

In this paper, we introduce capacitive micro-machined ultrasonic transducers (CMUTs) with electrically isolated multiple electrodes embedded in the same silicon nitride CMUT membrane. Some of the advantages of this structure are demonstrated using a dual-electrode CMUT with separate transmit and receive electrodes as an example. By locating the transmit electrodes near the edges of a rectangular CMUT membrane, the stable displacement range, hence the maximum pressure amplitude during transmit mode is increased without collapsing the membrane when operated within static collapse voltage range. In the receive mode, the center receive electrode is brought closer to the substrate by biasing the side electrodes, and a higher electromechanical transformer ratio is obtained at low direct current (DC) bias. Therefore, dual-electrode CMUT has an effectively larger gap as compared to conventional CMUT during transmit, and it has an effectively smaller gap during receive. Demonstrative experiments are performed on dual-electrode CMUTs with rectangular membranes with different side and center electrode sizes for transmit and receive measurements. By using the two 4-microm wide side electrodes and an 8-microm wide center electrode on a 20-microm wide membrane, a 6.8 dB increase in maximum output pressure is obtained with side electrode excitation as compared to conventional center electrode. Similarly, the receive performance improvement was demonstrated while reducing the DC bias requirements. Simple finite-element and equivalent circuit-based models were developed to successfully model the behavior of dual-electrode CMUTs. Simulations show that, with simple modifications, more than 10 dB overall sensitivity improvement is feasible with dual-electrode CMUTs with rectangular membranes.

Computer-Aided Design↗