PubMed Health⌕ Search

Biomedical subjects

Raymond A Applegate

Publications and source records attributed to Raymond A Applegate.

At least 19 recordsLinked to original sources

Metrics of retinal image quality predict visual performance in eyes with 20/17 or better visual acuity.

PURPOSE: The purpose of this study is to determine the ability of single-value metrics of retinal image quality of the eye to predict visual performance as measured by high (HC) and low (LC) -contrast acuity at photopic (P) and mesopic (M) light levels in eyes with 20/17 and better visual acuity. METHODS: Forty-nine normal subjects in good health ranging in age from 21.8 to 62.6 with 20/17 or better monocular high-contrast logarithm of the minimum angle of resolution (logMAR) acuity served as subjects. Wavefront error through the 10th Zernike radial order over a 7-mm pupil was measured on each test eye using a custom-built Shack/Hartmann wavefront sensor. For each eye, 31 different single-value retinal image quality metrics were calculated. Visual acuity was measured using HC (95%) and LC (11%) logMAR at photopic (270 cd/m) and mesopic (0.75 cd/m) light levels. To determine the ability of each metric of retinal image quality to predict each type of logMAR acuity (P HC, P LC, M HC, and M LC), each acuity measure was regressed against each optical quality metric. RESULTS: The ability of the metrics of retinal image quality to predict logMAR acuity improved as luminance and/or contrast is lowered. The best retinal image quality metric (logPFSc) accounted for 2.6%, 15.1%, 27.6%, and 40.0% of the variance in P HC, P LC, M HC, and M LC logMAR acuity, respectively. CONCLUSIONS: In eyes with 20/17 and better P HC acuity, P HC logMAR acuity is insensitive to variations in retinal image quality compared with M LC logMAR acuity. Retinal image quality becomes increasingly predictive of logMAR acuity as contrast and/or luminance is decreased. Everyday life requires individuals to function over a large range of contrast and luminance levels. Clinically, the impact of retinal image quality as a function of luminance and contrast is readily measurable in a time-efficient manner with M LC logMAR acuity charts.

Adult↗

Impact of Zernike-fit error on simulated high- and low-contrast acuity in keratoconus: implications for using Zernike-based corrections.

This study examines the extent to which a Zernike-based optical correction can restore acuity in keratoconus as a function of disease severity and contrast level. Increasingly complete Zernike corrections in the presence of Zernike-fit error were simulated. Acuity for keratoconic eyes with <60 D maximum corneal power reached 20/13 with a fifth-order Zernike correction under high-contrast conditions and exhibited a loss of 0.1 logMAR (minimum angle of resolution) (from 20/32 to 20/40) for low-contrast conditions. Acuity for keratoconic eyes with >60 D maximum corneal power approached 20/13 with sixth-tenth-order corrections under high-contrast conditions but did not return to similar levels with a tenth-order correction for low-contrast conditions. The results suggest that fit error affects visual performance for more difficult tasks and that restoring high-contrast acuity (20/16 or better) using a fifth-order Zernike correction is not limited by Zernike=fit error for over 88% of keratoconus cases.

Computer Simulation↗

Extracting wavefront error from Shack-Hartmann images using spatial demodulation.

PURPOSE: To determine whether the spatial demodulation processing of Shack-Hartmann images is suitable for extracting wavefront gradients for ocular wavefront sensors. METHODS: We developed a custom software program to implement the spatial demodulation technique. To test the algorithm's performance, we generated simulated spot images and obtained an eye examination image. We generated a collection of simulated aberrated spot images corresponding to: astigmatic wavefront (-5.00 -2.00 x 17), highly aberrated defocus (+/-20.00 diopters [D]), high-resolution defocus (-0.01 D), and third-order aberrations (trefoil and coma). The eye examination image and its measured Zernike coefficients were obtained from a Shack-Hartmann ocular aberrations system. We evaluated the output from the algorithm in terms of comparing the results to the known Zernike coefficients (for the simulated images) or the previously measured Zernike coefficients (for the eye examination image). RESULTS: The spatial demodulation algorithm was able to correctly recover the aberrations to better than 1/100 (0.01) D for the simulated spot images. The processing of the eye examination image yielded results within approximately 1/4 (0.25) D to the values provided by the Shack-Hartmann system. CONCLUSIONS: From the set of simulated images and the eye examination image used to test the spatial demodulation technique, it appears that the method is suitable for application in ocular wavefront aberrations Shack-Hartmann systems. The method appears capable of accurately processing high levels of aberrations (+/-20.00 D) as well as providing high resolution as evidenced by finding the -0.01 D defocus. The method may be especially well suited for processing highly aberrated wavefronts.

Algorithms↗

Metrics of optical quality derived from wave aberrations predict visual performance.

Wavefront-guided refractive surgery and custom optical corrections have reduced the residual root mean squared (RMS) wavefront error in the eye to relatively low levels (typically on the order of 0.25 microm or less over a 6-mm pupil, a dioptric equivalent of 0.19 D). It has been shown that experimental variation of the distribution of 0.25 microm of wavefront error across the pupil can cause variation in visual acuity of two lines on a standard logMAR acuity chart. This result demonstrates the need for single-value metrics other than RMS wavefront error to quantify the effects of low levels of aberration on acuity. In this work, we present the correlation of 31 single-value metrics of optical quality to high-contrast visual acuity for 34 conditions where the RMS wavefront error was equal to 0.25 microm over a 6-mm pupil. The best metric, called the visual Strehl ratio, accounts for 81% of the variance in high-contrast logMAR acuity.

Humans↗

Accuracy and precision of objective refraction from wavefront aberrations.

We determined the accuracy and precision of 33 objective methods for predicting the results of conventional, sphero-cylindrical refraction from wavefront aberrations in a large population of 200 eyes. Accuracy for predicting defocus (as specified by the population mean error of prediction) varied from -0.50 D to +0.25 D across methods. Precision of these estimates (as specified by 95% limits of agreement) ranged from 0.5 to 1.0 D. All methods except one accurately predicted astigmatism to within +/-1/8D. Precision of astigmatism predictions was typically better than precision for predicting defocus and many methods were better than 0.5D. Paraxial curvature matching of the wavefront aberration map was the most accurate method for determining the spherical equivalent error whereas least-squares fitting of the wavefront was one of the least accurate methods. We argue that this result was obtained because curvature matching is a biased method that successfully predicts the biased endpoint stipulated by conventional refractions. Five methods emerged as reasonably accurate and among the most precise. Three of these were based on pupil plane metrics and two were based on image plane metrics. We argue that the accuracy of all methods might be improved by correcting for the systematic bias reported in this study. However, caution is advised because some tasks, including conventional refraction of defocus, require a biased metric whereas other tasks, such as refraction of astigmatism, are unbiased. We conclude that objective methods of refraction based on wavefront aberration maps can accurately predict the results of subjective refraction and may be more precise. If objective refractions are more precise than subjective refractions, then wavefront methods may become the new gold standard for specifying conventional and/or optimal corrections of refractive errors.

Diagnostic Techniques, Ophthalmological↗

A population study on changes in wave aberrations with accommodation.

Wave aberrations were measured with a Shack-Hartmann wavefront sensor (SHWS) in the right eye of a large young adult population when accommodative demands of 0, 3, and 6 D were presented to the tested eye through a Badal system. Three SHWS images were recorded at each accommodative demand and wave aberrations were computed over a 5-mm pupil (through 6th order Zernike polynomials). The accommodative response was calculated from the Zernike defocus over the central 3-mm diameter zone. Among all individual Zernike terms, spherical aberration showed the greatest change with accommodation. The change of spherical aberration was always negative, and was proportional to the change in accommodative response. Coma and astigmatism also changed with accommodation, but the direction of the change was variable. Despite the large inter-subject variability, the population average of the root mean square for all aberrations (excluding defocus) remained constant for accommodative levels up to 3.0 D. Even though aberrations change with accommodation, the magnitude of the aberration change remains less than the magnitude of the uncorrected aberrations, even at high accommodative levels. Therefore, a typical eye will benefit over the entire accommodative range (0-6 D) if aberrations are corrected for distance viewing.

Accommodation, Ocular↗

Interaction between aberrations to improve or reduce visual performance.

PURPOSE: To investigate how pairs of Zernike modes interact to increase or decrease visual acuity. SETTING: Visual Optics Institute, College of Optometry, University of Houston, Houston, Texas, USA. METHODS: Subjects read aberrated and unaberrated visual acuity charts 3 times. Each aberrated chart was produced by convolving an aberrated point-spread function with an unaberrated acuity chart. Point-spread functions were defined by 4 pairs of Zernike modes. For each pair, 9 combinations were used, ranging from all aberration being loaded into the first mode to all aberration being loaded into the second mode. The root mean square (RMS) wavefront error always totaled 0.25 microm (6.0 mm pupil), a level similar to the aberration induced by traditional flying small-spot laser refractive surgeries. RESULTS: For all conditions (except the unaberrated charts), visual acuity decreased. Acuity varied significantly depending on which modes were mixed and the relative contribution of each mode. Modes 2 radial orders apart and having the same sign and angular frequency tended to combine to increase visual acuity. Modes within the same radial order tended to combine to decrease acuity. CONCLUSIONS: For low levels of aberration, the RMS wavefront error is not a good predictor of visual acuity. Clinically, it is important to define how aberrations interact to optimize visual performance. New metrics of optical/neural performance that correlate better with clinical measures of visual performance need to be adopted or developed, as well as new clinically viable measures of visual performance that are sensitive to subtle changes in optical performance.

Adult↗

Comparison of monochromatic ocular aberrations measured with an objective cross-cylinder aberroscope and a Shack-Hartmann aberrometer.

Repeated measures of wavefront aberrations were taken along the line-of-sight of seven eyes using two instruments: an objective, cross-cylinder aberroscope (OA) and a Shack-Hartmann (SH) aberrometer. Both instruments were implemented on the same optical table to facilitate interleaved measurements on the same eyes under similar experimental conditions. Variability of repeated measures of individual coefficients tended to be much greater for OA data than for SH data. Although Zernike coefficients obtained from a single measurement were generally larger when measured with the OA than with the SH, the averages across five trials were often smaller for the OA. The Zernike coefficients obtained from the two instruments were not significantly correlated. Radial modulation-transfer functions and point-spread functions derived from the two sets of measurements were similar for some subjects, but not all. When average Zernike coefficients were used to determine optical quality, the OA indicated superior optics in some eyes, but the reverse trend was true if Zernike coefficients from individual trials were used. Possible reasons for discrepancies between the OA and SH measurements include difference in sampling density, quality of data images, alignment errors, and temporal fluctuations. Multivariate statistical analysis indicated that the SH aberrometer discriminated between subjects much better than did the objective aberroscope.

Diagnostic Techniques, Ophthalmological↗

Visual acuity as a function of Zernike mode and level of root mean square error.

BACKGROUND: The coefficients of normalized Zernike expansion are orthogonal and reflect the relative contribution of each mode to the total root mean square (RMS) wavefront error. The relationship between the level of RMS wavefront error within a mode and its effect on visual performance is unknown. PURPOSE: To determine for various levels of RMS wavefront error how each mode of the normalized Zernike expansion for the second, third, and fourth orders affect high- and low-contrast acuity. METHODS: Three healthy optimally corrected cyclopleged subjects read aberrated and unaberrated high- and low-contrast logarithm of the minimum angle of resolution acuity charts monocularly through a 3-mm artificial pupil. Acuity was defined by the total number of letters read correctly up to the fifth miss. Aberrated and unaberrated charts were generated using a program called CTView. Six levels of RMS wavefront error were used (0.00, 0.05, 0.10, 0.15, 0.20, and 0.25 microm). Each level of RMS error was loaded into each mode of the second, third, and fourth radial orders individually for a total of 72 charts. Data were normalized by subject, and the normalized data were averaged across subjects. RESULTS: Across modes and within each mode as the level of RMS wavefront error increased above 0.05 microm of RMS wavefront error, visual acuity decreased in a linear fashion. Slopes of the linear fits varied depending on the mode. Modes near the center of the Zernike pyramid had steeper slopes than those near the edge. CONCLUSIONS: Increasing the RMS error within any single mode of the normalized Zernike expansion decreases visual acuity in a linear fashion. The slope of the best fitting linear equation varies with Zernike mode. Slopes near the center of the Zernike pyramid are steeper than those near the edge. Although the normalized Zernike expansion parcels RMS error orthogonally, the resulting effects on visual performance as measured by visual acuity are not orthogonal. New metrics of the combined effects of the optical and the neural transfer functions that are predictive of visual performance need to be developed.

Adult↗

Are all aberrations equal?

PURPOSE: To determine for a fixed RMS error (25 microm, over a 6-mm pupil) how each mode of the normalized Zernike polynomial (second through the fourth radial order) affects high and low contrast logMAR visual acuity. METHODS: Three healthy volunteers served as subjects. CTView was used to generate optically aberrated logMAR charts. Accommodation was paralyzed and pupils dilated. The foveal achromatic axis of the eye was aligned to a 3-mm pupil and the eye was optimally refracted. Aberrated acuity charts were read until five letters were missed. Data were normalized for each subject to the acuity obtained by reading unaberrated charts and plotted as letters lost as a function of Zernike mode. RESULTS: Defocus (Z2(0)) decreased letter acuity more than astigmatism (Z2(2), Z2(-2)). Coma (Z3(1), Z3(-1)) decreased acuity more than trefoil (Z3(3), Z3(-3)). Spherical aberration (Z4(0)) and secondary astigmatism (Z2(2), Z4(-2)) decreased acuity much more than quadrafoil (Z4(4), Z4(-4)). CONCLUSIONS: 1. For an equal amount of RMS error not all coefficients of the Zernike polynomial induce equivalent losses in high and low contrast logMAR acuity. 2. Wavefront error concentrated near the center of the pyramid adversely affects visual acuity more than modes near the edge of the pyramid. 3. Large changes in chart appearance are not reflected in equally large decreases in visual performance (ie, subjects could correctly identify highly aberrated letters). 4. Interactions between modes complicate weighting each Zernike mode for visual impact.

Adult↗

Standards for reporting the optical aberrations of eyes.

In response to a perceived need in the vision community, an OSA taskforce was formed at the 1999 topical meeting on vision science and its applications (VSIA-99) and charged with developing consensus recommendations on definitions, conventions, and standards for reporting of optical aberrations of human eyes. Progress reports were presented at the 1999 OSA annual meeting and at VSIA-2000 by the chairs of three taskforce subcommittees on (1) reference axes, (2) describing functions, and (3) model eyes.

Corneal Topography↗

Influence of exposure time and pupil size on a Shack-Hartmann metric of forward scatter.

PURPOSE: To determine the influence of exposure time and pupil size on a Shack-Hartmann (S/H) derived metric of forward scatter (MAX_SD) using a physical model of nuclear cataract. METHODS: A physical model eye was developed and mounted to a S/H wavefront sensor. The eye model consisted of a lens, variable pupil, simulated cataract, and retina. Located behind the pupil, a cuvette contained one of five polystyrene microsphere solutions simulating five levels of nuclear cataract severity. Cataract severity was described using a S/H derived metric of forward scatter (MAX SD), which measures aspects of forward scatter contained in the S/H lenslet point spread functions (PSF). To determine the impact of exposure time and pupil size, measurements of MAX_SD were regressed against cataract severity for three different exposure times and three different pupil sizes. RESULTS: MAX_SD was well correlated to cataract severity. Exposure time had the largest influence, and pupil size had the smallest influence on the forward scatter metric. When pupil size and exposure time were allowed to vary and image saturation was allowed to occur, MAX SD explained 83% of the variance in cataract severity. Excluding images where saturation occurred, holding optimal exposure time constant, and varying pupil size, MAX_SD explained 97% of the variance in cataract severity. CONCLUSIONS: The ability of the forward scatter metric derived from S/H measurements to predict cataract severity for a longitudinal study is optimized by selecting a patient-specific exposure at the initial cataract assessment to avoid saturation and maximize the dynamic range of the system. This patient-specific exposure should be used in all future visits.

Cataract↗

The importance of the phase transfer function to visual function and visual quality metrics.

PURPOSE: To propose a vision quality metric that directly incorporates the phase transfer function. METHODS: The process of retinal image formation from the pupil to the retina is presented to identify possible domains for calculating vision quality metrics. These domains are pupil plane metrics using ocular aberrations, and retinal plane metrics using the point spread function or optical transfer function. The importance of the phase transfer function to visual performance is demonstrated and a method is proposed for directly including phase in a vision quality metric based on ocular wavefront error. RESULTS: A family of vision quality metrics is proposed, which directly incorporates the Stiles-Crawford effect, contrast sensitivity function, and the phase transfer function. CONCLUSION: The phase transfer function is an important aspect of the quality of an image, and it may be directly included in metrics intended to quantify vision quality.

Contrast Sensitivity↗

Measuring visual acuity--mesopic or photopic conditions, and high or low contrast letters?

PURPOSE: To develop single-valued wavefront aberration metrics that correlate strongly with visual performance. The purpose of this study is to explore whether photopic high contrast visual acuity (VA) is an appropriate visual performance reference and whether mesopic and/or low contrast testing provides any advantage. METHODS: Subjects from the Texas Investigation of Cataract Optics study (N = 148) ranged in age from 21.6 to 83.8 years and from clear lens to dense nuclear cataract. Visual acuity was measured under four conditions: photopic high (VA(PHC)) and low (VA(PLC)) contrast, mesopic high (VA(MHC)) and low (VA(MLC)) contrast (photopic = 280 cd/m(2), mesopic = 0.75 cd/m(2)). Variables were tested for compliance with normality (-2.00 < skew and kurtosis < 2.00) and transformed if required. Linear regression and Bland-Altman 95% limits of agreement (+/-1.96 SD) were used to examine relationships between VA variables and between VA and wavefront aberration metrics. RESULTS: The two photopic measures VA(PHC) (skew = 2.57, kurtosis = 12.2) and VA(PLC) (1.67, 5.41) were poorly distributed, but the two mesopic measures VA(MHC) (0.88, 1.67) and VA(MLC) (0.29, -0.18) were normally distributed. Strong correlations existed between the (transformed) VA variables (R: 0.53 to 0.84). However, limits of agreement ranged over 0.30 to 0.42 logMAR, whereas retest data suggested a range of 0.15. All four were offered in stepwise multiple linear regression for 30 wavefront metrics: 20 included VA(MLC) alone, two included VA(PLC), two included VA(MHC) and six included both VA(MLC) and VA(MHC); R(2) averaged 25%. CONCLUSION: Although strongly correlated, low contrast and/or mesopic VA testing provides different information. Wave aberration metrics correlates better with VA(MLC) making this the visual performance test of choice.

Adult↗