Right-sided vagus nerve stimulation inhibits induced spinal cord seizures.

We have previously shown that left-sided vagus nerve stimulation results in cessation of induced spinal cord seizures. To test our hypothesis that right-sided vagus nerve stimulation will also abort seizure activity, we have initiated seizures in the spinal cord and then performed right-sided vagus nerve stimulation in an animal model. Four pigs were anesthetized and placed in the lateral position and a small laminectomy performed in the lumbar region. Topical penicillin, a known epileptogenic drug to the cerebral cortex and spinal cord, was next applied to the dorsal surface of the exposed cord. With the exception of the control animal, once seizure activity was discernible via motor convulsion or increased electrical activity, the right vagus nerve previously isolated in the neck was stimulated. Following multiple stimulations of the vagus nerve and with seizure activity confirmed, the cord was transected in the midthoracic region and vagus nerve stimulation performed. Right-sided vagus nerve stimulation resulted in cessation of spinal cord seizure activity in all animals. Transection of the spinal cord superior to the site of seizure induction resulted in the ineffectiveness of vagus nerve stimulation in causing cessation of seizure activity in all study animals. As with left-sided vagus nerve stimulation, right-sided vagus nerve stimulation results in cessation of induced spinal cord seizures. Additionally, the effects of right-sided vagus nerve stimulation on induced spinal cord seizures involve descending spinal pathways. These data may aid in the development of alternative mechanisms for electrical stimulation for patients with medically intractable seizures and add to our knowledge regarding the mechanism for seizure cessation following peripheral nerve stimulation.

Animals↗

Chronic myocardial infarction is a substrate for bradycardia-induced spontaneous tachyarrhythmias and sudden death in conscious animals.

INTRODUCTION: Patients with bradycardia can have severe tachyarrhythmias but it is unclear whether bradycardia alone can induce arrhythmias or whether an additional substrate is necessary. While several animal models of ventricular tachycardia (VT) exist, no model has been reported to mimic the clinical condition of spontaneous VT and sudden cardiac death (SCD) in the presence of bradycardia and chronic myocardial infarction (MI) in large animals without manipulation of the autonomic nervous system. We tested the hypothesis that MI and bradycardia cause more spontaneous sustained VT than does bradycardia alone. METHODS AND RESULTS: Sheep (42-56 kg) underwent atrioventricular (AV) node catheter ablation alone (n = 5) or AV node ablation and 150 minutes of angioplasty balloon occlusion of the left anterior descending coronary artery (n = 9). An implantable cardioverter defibrillator delivered rescue shocks and demand pacing at 90 beats per minute for the first week and at 40 beats per minute thereafter. Electrograms were continuously radiotelemetered and recorded for 6 weeks. Acute post-MI VT disappeared by day 4. The sudden bradycardia on day 8 triggered numerous premature ventricular contractions (PVCs) and episodes of sustained VT lasting >30 seconds during the next 5 weeks. There were 43 episodes of sustained VT and no spontaneous ventricular fibrillation (VF) with bradycardia alone. However, in the presence of both MI and bradycardia there were 970 episodes of VT/VF (P < 0.05) and three deaths at days 13, 15, and 34. The average 24-hour count of PVCs was similar at day 7 between the two groups but by days 11 and 40, the PVC counts were 35 times and 4 times greater, respectively, in the presence of bradycardia and chronic MI compared to bradycardia alone. No significant difference in the incidence of PVCs was detected because of large individual variation between the two groups (P = 0.21). A high PVC count did not appear to predict SCD. CONCLUSION: The combination of MI and bradycardia secondary to AV node ablation in sheep produces a higher incidence of VT than bradycardia alone, suggesting that this preparation can serve as a model for the study of VT and sudden cardiac death.

Animals↗

Measuring surface potential components necessary for transmembrane current computation using microfabricated arrays.

This study was designed to test the feasibility of using microfabricated electrodes to record surface potentials with sufficiently fine spatial resolution to measure the potential gradients necessary for improved computation of transmembrane current density. To assess that feasibility, we recorded unipolar electrograms from perfused rabbit right ventricular free wall epicardium (n = 6) using electrode arrays that included 25-microm sensors fabricated onto a flexible substrate with 75-microm interelectrode spacing. Electrode spacing was therefore on the size scale of an individual myocyte. Signal conditioning adjacent to the sensors to control lead noise was achieved by routing traces from the electrodes to the back side of the substrate where buffer amplifiers were located. For comparison, recordings were also made using arrays built from chloridized silver wire electrodes of either 50-microm (fine wire) or 250-microm (coarse wire) diameters. Electrode separations were necessarily wider than with microfabricated arrays. Comparable signal-to-noise ratios (SNRs) of 21.2 +/- 2.2, 32.5 +/- 4.1, and 22.9 +/- 0.7 for electrograms recorded using microfabricated sensors (n = 78), fine wires (n = 78), and coarse wires (n = 78), respectively, were found. High SNRs were maintained in bipolar electrograms assembled using spatial combinations of the unipolar electrograms necessary for the potential gradient measurements and in second-difference electrograms assembled using spatial combinations of the bipolar electrograms necessary for surface Laplacian (SL) measurements. Simulations incorporating a bidomain representation of tissue structure and a two-dimensional network of guinea pig myocytes prescribed following the Luo and Rudy dynamic membrane equations were completed using 12.5-microm spatial resolution to assess contributions of electrode spacing to the potential gradient and SL measurements. In those simulations, increases in electrode separation from 12.5 to 75.0, 237.5, and 875.0 microm, which were separations comparable to the finest available with our microfabricated, fine wire, and coarse wire arrays, led to 10%, 42%, and 81% reductions in maximum potential gradients and 33%, 76%, and 96% reductions in peak-to-peak SLs. Maintenance of comparable SNRs for source electrograms was therefore important because microfabrication provides a highly attractive methods to achieve spatial resolutions necessary for improved computation of transmembrane current density.

Algorithms↗

New technologies of internal defibrillation.

This paper reviews recent research seeking to provide more efficient device oriented treatments for atrial and ventricular fibrillation to improve implantable cardioverter defibrillator (ICD) therapy. Investigators have proposed and tested many innovative technologies that may be included in future ICDs. Amongst the most promising technologies are combined cardiac resynchronization therapy and defibrillation, defibrillation coils in the coronary venous system, critical timing of defibrillation shocks, and pacing during ventricular fibrillation and tachycardia. Atrial defibrillation with ICDs is an area of considerable interest, but is not likely to gain widespread application unless acceptable methods of lowering pain associated with defibrillation shocks are implemented.

Atrial Fibrillation↗

Quantification of activation patterns during ventricular fibrillation in open-chest porcine left ventricle and septum.

BACKGROUND: A single stationary mother rotor has been hypothesized to be responsible for maintenance of ventricular fibrillation (VF) in the guinea pig. Previous studies have pointed to the ventricular septum as a possible location for a mother rotor in the pig heart. OBJECTIVES: The purpose of this study was to test the hypothesis that a mother rotor is located in the septum. METHODS: In seven open-chest pigs, we mapped the first 20 seconds of electrically induced VF simultaneously from the posterior left ventricle (LV) and right side of the septum with two electrical arrays. Each array contained 504 electrodes (21 x 24) spaced 2 mm apart in the LV and 1.5 mm apart in the septum. RESULTS: The percentage of VF wavefronts that formed reentrant circuits was significantly lower in the septum (1% +/- 1% [mean +/- SD]) than in the LV (2% +/- 1%). The peak frequency during VF also was significantly smaller in the septum (8.6 Hz +/- 3.0 Hz) than in the LV (10.4 Hz +/- 3.4 Hz). The mean direction of spread of activation of VF wavefronts was away from the region where the posterior LV free wall intersects the posterior septum in both the LV and septum. CONCLUSIONS: The lower incidence of reentry and lower peak frequency in the mapped region of the septum than in the LV indicate that a mother rotor is not present in swine on the RV side of the septum. The mean directions of the VF activation sequences in the LV and septum suggest that if a mother rotor is present during the first 20 seconds of VF, it exists where the posterior LV free wall joins the septum, the region where the posterior papillary muscle inserts.

Animals↗

Decrease in fluoroscopic cardiac silhouette excursion precedes hemodynamic compromise in intraprocedural tamponade.

BACKGROUND: Acute pericardial tamponade is a life-threatening complication of invasive cardiovascular procedures. Survival depends on early recognition and treatment. A diagnostic test to detect pericardial fluid accumulation before a significant fall in blood pressure and without contamination of the sterile field would be valuable. OBJECTIVE: We tested the hypothesis that fluoroscopic excursion of the cardiac silhouette decreases early in the course of acute pericardial tamponade and precedes hemodynamic compromise. METHODS: The pericardial space of seven pigs was accessed by a sub-xiphoid puncture. Tamponade was produced by intrapericardial saline infusion at 20-25 mL/minute until the pericardial pressure equalized with right ventricular end diastolic pressure or the systolic blood pressure reached 40 mmHg. Supine fluoroscopic images were obtained every 2 minutes in the left anterior oblique view with simultaneous echocardiography. The fluoroscopic heart silhouette was digitized, and the maximum excursion during the cardiac cycle was quantified by custom software. The qualitative excursion of the fluoroscopic heart silhouette on randomly selected video images was also graded by two independent observers who were blinded to the time course of the experiment and the hemodynamics. RESULTS: During progressive pericardial fluid accumulation, the cardiac silhouette excursion quantified by the custom software (p < 0.001) and by video rating (p < 0.0001) was significantly reduced within 2 minutes. A statistically significant fall in blood pressure compared with baseline did not occur until 6 minutes (89 +/- 21 vs. 121 +/- 15 mmHg, p < 0.001). The interobserver agreement was very close, with a kappa statistic of 0.78. The reduction in cardiac silhouette excursion was apparent as soon as the effusion was detected by echocardiography. CONCLUSION: Cardiac silhouette excursion becomes reduced early in the course of acute pericardial fluid accumulation. This fluoroscopic observation can be used to detect impending pericardial tamponade before hemodynamic collapse.

Acute Disease↗

Regional variation in capture of fibrillating swine left ventricle during electrical stimulation.

INTRODUCTION: While it has been shown that electrical stimulation can capture a region of myocardium during ventricular fibrillation (VF), the ideal location to stimulate to maximize capture of the fibrillating in vivo left ventricle (LV) is not known. We previously demonstrated a mean directionality to the propagation of VF wavefronts in swine from posterior to anterior LV. We hypothesized that this directionality of VF wavefronts would affect capture of the LV epicardium while stimulating during VF. METHODS AND RESULTS: In seven open-chest swine, during different VF episodes, electrical stimulation was performed singly or simultaneously from two lines of 26 epicardial electrodes, one on the posterior LV adjacent to the posterior descending coronary artery and another on the anterior LV adjacent to the left anterior descending coronary artery. Mapping was performed between the line of stimulating electrodes with 768 recording electrodes 2-mm apart. The incidence and extent of epicardium captured by stimulation through the lines of stimulating electrodes were determined in the mapped region. Capture occurred during 67% of 78 VF episodes. Capture from the posterior LV line was achieved in 88% of the episodes and from the anterior LV line in 44% of the episodes (P = 0.001). The maximum amount of myocardium captured was also much greater for stimulating from the posterior as compared to the anterior LV line (232 +/- 168 mm(2) vs 64 +/- 124 mm(2), P = 0.003). A significant part of the variability in capture was related to the direction of the mean VF wavefront velocity vector in each animal (r = 0.84, P < 0.05). CONCLUSION: Electrical stimulation from the posterior LV resulted in a greater incidence and extent of LV capture than stimulation from the anterior LV. A significant component of the variability in capture is related to the mean direction of VF wavefronts.

Animals↗

Design and initial evaluation of an implantable sonomicrometer and CW Doppler flowmeter for simultaneous recordings with a multichannel telemetry system.

We have developed a sonomicrometer and continuous wavelength (CW) Doppler flowmeter for a multichannel telemetry system. These developments will enable us to measure ventricular dimension and coronary artery blood velocity, which are valuable parameters to characterize sudden cardiac death (SCD) in ambulatory animal models of ventricular arrhythmias. The design goals for the sensors were accuracy, low power consumption, small size and compatibility with each other. The circuits were designed successfully and tested simultaneously in vivo. The CW Doppler flowmeter draws 9 mA and the sonomicrometer draws 28 mA on a 5-V supply. The ability to measure heart dimension and blood velocity will add significantly to our understanding of the sequence of events leading up to spontaneous sudden cardiac death.

Animals↗

Mechanisms for the maintenance of ventricular fibrillation: the nonuniform dispersion of refractoriness, restitution properties, or anatomic heterogeneities?

INTRODUCTION: The relative importance of nonuniform dispersion of refractoriness, steep restitution slopes, and anatomic heterogeneities in causing conduction block during ventricular fibrillation (VF) remains unknown. METHODS AND RESULTS: In six open-chest pigs, ventricular refractoriness and restitution curves were estimated from activation recovery intervals (ARIs) calculated from 504 (21 x 24) unipolar electrode recordings 2 mm apart in a plaque sutured to the left ventricular (LV) free wall. A steady-state restitution protocol was performed twice at each of two pacing sites: the LV base and near the left anterior descending artery. VF was electrically induced four times and the incidence of conduction block at each electrode during the first 20 seconds was determined by an automated algorithm. The gradient of the ARI was calculated at each electrode to estimate the spatial dispersion of refractoriness. An exponential curve was fit to the restitution plots of ARIs versus the corresponding diastolic intervals (DIs) for all pacing cycle lengths at each electrode. The locations of epicardial blood vessels were noted after the study. Spatial patterns of conduction block were significantly correlated between the four VF episodes in the same animal (r = 0.66 +/- 0.07, P < 0.05). At the shortest pacing cycle length, the spatial distribution of ARIs, ARI gradients, and restitution slopes was not random but formed clusters of similar values. However, none of these variables was significantly correlated with the incidence of conduction block, even though ARI gradients >2 msec/mm were present between many clusters and approximately 90% of restitution slopes were >1. Instead, conduction block frequently appeared to cluster along epicardial vessels. CONCLUSION: Neither the dispersion of refractoriness nor action potential duration restitution determined during rapid pacing by itself is the major determinant of the location of conduction block during early VF in normal pigs. It may be that these factors interact synergistically with each other as well as with other factors, including anatomic heterogeneities such as those caused by blood vessels, which may be particularly important for the formation of conduction block and maintenance of VF.

Animals↗

Evidence that activation following failed defibrillation is not caused by triggered activity.

BACKGROUND: Earliest postshock activation following failed defibrillation shocks slightly lower than the defibrillation threshold (DFT) in large animals appears to arise from a focus. We tested the hypothesis that these foci are caused by early or delayed afterdepolarizations (EADs or DADs) by performing epicardial electrical mapping and giving the EAD inhibitor pinacidil or the DAD inhibitor flunarizine to see if the foci were extinguished or altered in timing or location. METHODS AND RESULTS: A sock containing 504 electrodes was placed over the entire ventricular epicardium of 12 open-chested pigs. After the DFT was determined and additional shocks given, pinacidil was administered to 6 pigs and flunarizine to 6 pigs. Then, the DFT was again determined and additional shocks were given. Pinacidil significantly shortened the effective refractory period (ERP) (162 +/- 16 vs 130 +/- 28 msec) and action potential duration (APD(90)) (179 +/- 6 vs 149 +/- 19 msec) and significantly increased the peak frequency of the power spectrum of a left ventricle (LV) electrode during ventricular fibrillation (VF) (9.3 +/- 0.6 vs 10.5 +/- 1.0 Hz), while flunarizine did not significantly alter the ERP (162 +/- 8 vs 167 +/- 18 msec) or APD(90) (187 +/- 12 vs 191 +/- 20) but significantly reduced the peak frequency (9.2 +/- 0.5 vs 7.5 +/- 1.0 Hz). These findings suggest the drugs had their expected electrophysiological effects. However, the DFT was not significantly changed by either drug. Following the same strength shock 10% below the predrug DFT, earliest postshock activation arose in a focal epicardial pattern from the anterior-apical LV both before and after the drugs. The time from the shock until the appearance of this activation was not significantly different before and after either drug. CONCLUSION: The lack of change in DFT as well as the lack of change in the incidence, location, and timing of the postshock focus with sub-DFT strength shocks before and after pinacidil and flunarizine provide evidence that these foci are not caused by triggered activity.

Analysis of Variance↗

Our search for the porcine mother rotor.

A single stationary mother rotor, located in the fastest activating region and giving rise to activation fronts that propagate throughout the remainder of the myocardium, has been hypothesized to be responsible for the maintenance of ventricular fibrillation (VF). Others have reported a mother rotor in guinea pigs and rabbits. We wanted to see if a mother rotor exists in a larger heart, that is, pigs. Epicardial mapping studies have demonstrated that VF wavefronts in pigs tend to propagate from the posterior basal LV to the anterior LV and on to the anterior RV, raising the possibility of a mother rotor in the posterior LV. However, no sustained reentry consistent with a mother rotor was found on the posterior LV epicardium, even though an intramural mapping study showed that the fastest activating transmural layer was near the epicardium. Many wavefronts in the posterior LV entered the mapped region from the posterior boundary of the mapping array, adjacent to the posterior descending coronary artery, raising the possibility that a mother rotor is located in the right ventricle or septum. Since a previous study has shown that the RV activates more slowly than the LV during VF, the more likely site for a mother rotor was the septum. However, we then performed a study in which we recorded from the right side of the septum and found that reentry was uncommon there also and that the activation rate was slower than the posterobasal LV. Many of the VF wavefronts in the septum passed from the posterior septum toward the anterior septum. This fact coupled with the fact that many wavefronts passed from the posterior LV free wall toward the anterior LV free wall point to the region where the posterior free wall intersects with the septum, the region where the posterior papillary muscle is located, as the possible site of a mother rotor. Indeed, a recent abstract by others reports that, after propranolol, a stable reentrant circuit is present on the endocardium at the insertion of the posterior papillary muscle into the LV free wall in pigs.

Animals↗

Vagus nerve stimulation for induced spinal cord seizures: insights into seizure cessation.

OBJECT: Vagus nerve stimulation is known to decrease the frequency, duration, and intensity of some types of intracranial seizures in both humans and animals. Although many theories abound concerning the mechanism for this action, the true cause remains speculative. To potentially elucidate a pathway in which vagus nerve stimulation aborts seizure activity, seizures were initiated not in the cerebral cortex but in the spinal cord and then vagus nerve stimulation was performed. METHODS: Ten pigs were anesthetized and placed in the lateral position, and a small laminectomy was performed in the lumbar region. Topical penicillin, a known epileptogenic drug to the cerebral cortex and spinal cord, was applied to the dorsal surface of the exposed cord. With the exception of two animals that were used as controls, once seizure activity was discernible via motor convulsion or increased electrical activity the left vagus nerve, which had been previously isolated in the neck, was stimulated. Following multiple stimulations of the vagus nerve and with seizure activity confirmed, the cord was transected in the midthoracic region and vagus nerve stimulation was performed. Vagus nerve stimulation resulted in cessation of spinal cord seizure activity in all (87.5%) but one experimented animal. Transection of the spinal cord superior to the site of seizure induction resulted in the ineffectiveness of vagus nerve stimulation to cause cessation of seizure activity in all study animals. CONCLUSIONS: The effects of vagus nerve stimulation on induced spinal cord seizures involve descending spinal pathways. The authors believe that this experiment is the first to demonstrate that spinal cord neuronal hyperactivity can be suppressed by stimulation of a cranial nerve. These data may aid in the development of alternative mechanisms for electrical stimulation in patients with medically intractable seizures. Further studies are now necessary to isolate which specific tracts, nuclei, and neurotransmitters are involved in this process.

Animals↗

High-resolution optical mapping of intramural virtual electrodes in porcine left ventricular wall.

OBJECTIVE: It is believed that shock-induced intramural virtual electrodes (IVE) play a critical role in defibrillation. IVE were recently demonstrated in the porcine left ventricle (LV), but their origin remains unknown. Macroscopic optical mapping showed that strong shocks induce IVE of only one polarity, which contradicts theoretical predictions. It is hypothesized that IVE have a microscopic origin and that microscopic positive and negative IVE are spatially averaged during macroscopic optical mapping. This hypothesis was examined by mapping V(m) responses at the transmural LV surface with increased optical resolution. METHODS: Rectangular shocks (strength=2-48 V/cm; duration=10 ms) were applied across isolated coronary-perfused porcine LV preparations (n=7) during the action potential plateau and diastole. Shock-induced V(m) responses were measured at low resolution (LR; 1.2 mm/diode) and high resolution (HR; 0.11 mm/diode). RESULTS: During plateau shocks with strength > or =20 V/cm, LR recordings demonstrated only negative DeltaV(m) extending to the cathodal preparation edge. In contrast, HR recordings from this area as well as from intramural locations revealed both positive and negative DeltaV(m) at all shock strengths. During diastolic shocks, only positive polarizations were observed at LR, but both positive and negative polarizations were detected at HR. In areas of negative polarization, large activation delays were found at HR, whereas LR recordings at these locations demonstrated fast activation. CONCLUSIONS: High- and low-resolution optical mapping produced radically different patterns of shock-induced polarization and activation. The occurrence of positive and negative polarizations during plateau and diastolic shocks at high but not low resolution provides evidence for microscopic nature of IVE in LV wall.