PubMed Health⌕ Search

Biomedical subjects

Raymond F Smith

Publications and source records attributed to Raymond F Smith.

3 recordsLinked to original sources

Ultrahigh strength in nanocrystalline materials under shock loading.

Molecular dynamics simulations of nanocrystalline copper under shock loading show an unexpected ultrahigh strength behind the shock front, with values up to twice those at low pressure. Partial and perfect dislocations, twinning, and debris from dislocation interactions are found behind the shock front. Results are interpreted in terms of the pressure dependence of both deformation mechanisms active at these grain sizes, namely dislocation-based plasticity and grain boundary sliding. These simulations, together with new shock experiments on nanocrystalline nickel, raise the possibility of achieving ultrahard materials during and after shock loading.

Journal Article↗

Picosecond-resolution soft-x-ray laser plasma interferometry.

We describe a soft-x-ray laser interferometry technique that allows two-dimensional diagnosis of plasma electron density with picosecond time resolution. It consists of the combination of a robust high-throughput amplitude-division interferometer and a 14.7-nm transient-inversion soft-x-ray laser that produces approximately 5-ps pulses. Because of its picosecond resolution and short-wavelength scalability, this technique has the potential for extending the high inherent precision of soft-x-ray laser interferometry to the study of very dense plasmas of significant fundamental and practical interest, such as those investigated for inertial confinement fusion. Results of its use in the diagnostics of dense large-scale laser-created plasmas are presented.

Journal Article↗

Longitudinal coherence measurements of a transient collisional x-ray laser.

We present what is to our knowledge the first longitudinal coherence measurement of a transient inversion collisional x-ray laser. We investigated the picosecond output of a Ni-like Pd x-ray laser at 14.68 nm generated by the COMET laser facility at the Lawrence Livermore National Laboratory. Interference fringes were generated with a Michelson interferometer setup in which a thin multilayer membrane was used as a beam splitter. We determined the longitudinal coherence for the 4d1S0 --> 4p1P1 lasing transition to be approximately 400 microm (1/e half-width) by changing the length of one interferometer arm and measuring the resultant variation in fringe visibility. The inferred gain-narrowed linewidth of approximately 0.29 pm is a factor of 4 less than previously measured in quasi-steady-state x-ray laser schemes.

Journal Article↗