PubMed Health⌕ Search

Biomedical subjects

Raymond J Carlson

Publications and source records attributed to Raymond J Carlson.

3 recordsLinked to original sources

Evaluating ventricular function with B-type natriuretic peptide in obstetric patients.

OBJECTIVE: To determine if a rapid serum assay for B-type natriuretic peptide (BNP) provides information regarding ventricular function in obstetric patients with acute dyspnea. STUDY DESIGN: A review of 17 charts for 15 patients was undertaken. Seven patients had preeclampsia, 3 had preterm labor treated with aggressive tocolysis, and 5 had underlying cardiac and/or pulmonary disease. Each presented with signs and symptoms consistent with acute dyspnea. Serum BNP levels were obtained and other standard diagnostic procedures performed. Each patient was treated based on the findings of the standard diagnostic procedures. RESULTS: For the 7 patients with preeclampsia, elevated serum BNP levels correlated with acute ventricular overload that responded to volume management and diuresis. Two patients had marked elevation of serum BNP levels and were found to have significant left ventricular dysfunction that was not apparent by standard clinical evaluation. For preterm labor patients on tocolysis and patients with underlying cardiac or pulmonary disease, serum BNP levels were elevated for 5 of 6 patients with evidence of acute volume overload. CONCLUSION: Serum BNP levels provided useful information for the clinical evaluation and management of obstetric patients with acute dyspnea. In 2 patients, more serious cardiac dysfunction was detected with BNP than with clinical evaluation alone.

Acute Disease↗

Clinical utility of aortic pulses and pressures calculated from applanated radial-artery pulses.

Brachial artery cuff blood pressures are but approximations of central aortic pressures. The actual pressures against which the left ventricle must pump would be useful clinical information if obtained noninvasively. Our aim was to determine the clinical utility of aortic pulses and pressures calculated from noninvasively obtained radial-artery pulses. Radial-arterial pulses were recorded by applanation and calibrated with arm/cuff oscillometric pressures. Aortic pulses and pressures were calculated from the radial pulses by Fourier analysis and transfer functions. These calculated aortic pulses were compared with directly recorded aortic pulses by a transducer-tip catheter in a series of 50 patients undergoing cardiac catheterization. The correlation coefficient (r) of the measured versus the calculated aortic systolic blood pressure was +0.89, but the scatter was large (standard deviation of the differences=+/-11.3 mm Hg). The pulse pressure correlations were less good (r=+0.79) and also had a large scatter (+/-13.6 mm Hg). The average calculated pulse pressure was 11.5 mm Hg lower than the measured value because the cuff diastolic blood pressures, used to calibrate the radial pulses, were systematically higher than those in the aorta (8.9 mm Hg). Multivariable analysis incorporating height, age, heart rate, and ejection fraction as additional, independent variables eliminated mean differences between the new "predicted" and measured pressures, significantly improved correlation coefficients, and reduced the scatter. However, the improvements were small. The inaccuracy of the oscillometric cuff method for measuring arm blood pressure appears to be the limiting factor in the prediction of clinically useful, noninvasive aortic pressures.

Adult↗