PubMed Health⌕ Search

Biomedical subjects

Raymond Ro

Publications and source records attributed to Raymond Ro.

2 recordsLinked to original sources

Comparison of in vitro and in vivo acoustic response of a novel 50:50 PLGA contrast agent.

A comparison between in vitro and in vivo experiments conducted to investigate the acoustic properties of a novel, 1.2 microm diameter poly(lactic-co-glycolic acid) (50:50) (PLGA) ultrasound contrast agent, the development of which was described previously by us, is presented. A pulse-echo setup was used to determine enhancement in vitro. Additional in vitro studies further characterized the hollow microcapsules, including resonance frequency from attenuation measurements (from 2.25 to 15 MHz) and temperature effects (25 degrees C vs. 37 degrees C). In vivo, four rabbits received intravenous injections of the agent (dose range: 0.005-0.13 ml/kg). Quantitative in vivo dose-responses were calculated off-line using spectral power analysis of audio Doppler signals acquired from a custom-made 10 MHz cuff transducer placed around the surgically exposed distal aorta. This frequency was chosen since the very shallow scanning depths encountered in rabbits, in particular for the cuff transducer placed directly around the vessel, necessitates the use of high frequency imaging devices with sufficient spatial resolution to enable meaningful measurements. For qualitative assessments, two rabbits were imaged pre- and post-contrast administration (dose: 0.1 ml/kg) in power Doppler mode. Significant acoustic enhancements (up to 24 dB) were reported both in vitro and in vivo. Moreover, the rabbits did not show any adverse side effects from multiple injections (>20) of the agent. Measured in vitro resonance frequency between 3.09 and 3.49 MHz was lower than predicted for a similar sized free bubble, potentially due to capsule wall structure. Minimal loss of signal (approximately 4 dB) was observed at 25 degrees C over 20 min of insonation at 5 MHz but at 37 degrees C the signal dropped close to base line within the first 5 min. This temperature sensitivity could be due to loss of capsule integrity (and hence loss of gas). Potential causes include increased hydrolysis or polymer softening and increased water uptake by the shell at temperatures closer to the glass transition temperature (T(g)).

Acoustics↗

In vivo perfusion estimation using subharmonic contrast microbubble signals.

OBJECTIVE: The purpose of this study was to quantify perfusion in vivo using contrast-enhanced subharmonic imaging (SHI). METHODS: A modified LOGIQ 9 scanner (GE Healthcare, Milwaukee, WI) operating in gray scale SHI mode was used to measure SHI time-intensity curves in vivo. Four dogs received intravenous contrast bolus injections (dose, 0.1 mL/kg), and renal SHI was performed. After 3 contrast agent injections, a microvascular staining technique based on stable (nonradioactive) isotope-labeled microspheres (BioPhysics Assay Laboratory Inc, Worcester, MA) was used to quantify the degree of perfusion in 8 sections of each kidney. Low perfusion states were induced by ligating surgically exposed segmental renal arteries followed by contrast agent injections and microvascular staining. Digital clips were transferred to a personal computer, and SHI time-intensity curves were acquired in each section using Image-Pro Plus software (Media Cybernetics, Silver Spring, MD). Subharmonic fractional blood volumes were calculated, and the perfusion was estimated from the initial slope of the fractional blood volume uptake averaged over 3 injections. Subharmonic perfusion data were compared with the gold standard (ie, the microspheres) using linear regression analysis. RESULTS: In vivo gray scale SHI clearly showed flow and, thus, perfusion in the kidneys with almost complete suppression of tissue signals. In total, 270 SHI time-intensity curves were acquired, which reduced to 94 perfusion estimates after averaging. Subharmonic perfusion estimates correlated significantly with microsphere results (r = 0.57; P < .0001). The best SHI perfusion estimates occurred for high perfusion states in the anterior of the kidneys (r = 0.73; P = .0001). The corresponding root mean square error was 2.4%. CONCLUSIONS: Subharmonic perfusion estimates have been obtained in vivo. The perfusion estimates were in reasonable to good agreement with a microvascular staining technique.

Albumins↗