PubMed Health⌕ Search

Biomedical subjects

Reinhard Hickel

Publications and source records attributed to Reinhard Hickel.

At least 19 recordsLinked to original sources

Effects of dental probing on occlusal surfaces--a scanning electron microscopy evaluation.

The aim of this clinical-morphological study was to investigate the effects of dental probing on occlusal surfaces by scanning electron microscopy (SEM). Twenty sound occlusal surfaces of third molars and 20 teeth with initial carious lesions of 17- to 26-year-old patients (n = 18) were involved. Ten molars of each group were probed with a sharp dental probe (No. 23) before extraction; the other molars served as negative controls. After extraction of the teeth, the crowns were separated and prepared for the SEM study. Probing-related surface defects, enlargements and break-offs of occlusal pits and fissures were observed on all occlusal surfaces with initial carious lesions and on 2 sound surfaces, respectively. No traumatic defects whatsoever were visible on unprobed occlusal surfaces. This investigation confirms findings of light-microscopic studies that using a sharp dental probe for occlusal caries detection causes enamel defects. Therefore, dental probing should be considered as an inappropriate procedure and should be replaced by a meticulous visual inspection. Critical views of tactile caries detection methods with a sharp dental probe as a diagnostic tool seem to be inevitable in undergraduate and postgraduate dental education programmes.

Adolescent↗

The influence of curing times and light curing methods on the polymerization shrinkage stress of a shrinkage-optimized composite with hybrid-type prepolymer fillers.

OBJECTIVES: The aim of the study was to determine the influence of different light curing units (LCU) and regimes on the polymerization shrinkage stress (PSS) and the mechanical properties of a nano-hybrid composite. MATERIAL AND METHODS: The polymerization shrinkage force (PSF) was measured continuously with compliance compensation for 300s after photo-initiating the composite, Tetric EvoCeram (Ivoclar Vivadent, Schaan, FL, Shade A3) in a Stress-Strain Analyser. Astralis 10, Bluephase and MiniL.E.D LCU with exposure times 10, 20 and 40s were used (C-factor=0.33, n=8 per group). Immediately after the PSF measurements, mechanical properties of the samples were measured at the top and the bottom using a Fischerscope H100C (Helmut Fischer GmbH, Sindelfingen, Germany). Statistical analyses were done using one-way ANOVA (p<0.05) and Tukey post hoc test. RESULTS: Significant differences in the PSS for 10, 20 and 40s polymerization using Astralis 10 were found. The MiniL.E.D recorded low stress values. Modulus of elasticity is high after curing the composite with Astralis 10 at 10, 20 and 40s and for Bluephase 40s. Low moduli of elasticity were recorded for the MiniL.E.D and for the Bluephase 20 and 10s. The hardness values (HV) followed the same pattern as the modulus of elasticity. The Ramping mode of the MiniL.E.D had prolonged gel point. CONCLUSIONS: High intensity LCU produce not just high HV but also high shrinkage, making it important to balance both the effects by choosing the appropriate curing time. Soft-start regimes have no paramount benefit in a LED regarding stresses in the clinical situation.

Analysis of Variance↗

Cytotoxicity of dental composite (co)monomers and the amalgam component Hg(2+) in human gingival fibroblasts.

Unpolymerized resin (co)monomers or mercury (Hg) can be released from restorative dental materials (e.g. composites and amalgam). They can diffuse into the tooth pulp or the gingiva. They can also reach the gingiva and organs by the circulating blood after the uptake from swallowed saliva. The cytotoxicity of dental composite components hydroxyethylmethacrylate (HEMA), triethyleneglycoldimethacrylate (TEGDMA), urethanedimethacrylate (UDMA), and bisglycidylmethacrylate (Bis-GMA) as well as the amalgam component Hg(2+) (as HgCl(2)) and methyl mercury chloride (MeHgCl) was investigated on human gingival fibroblasts (HGFs) at two time intervals. To test the cytotoxicity of substances, the bromodeoxyuridine (BrdU) assay and the lactate dehydrogenase (LDH) assay were used. The test substances were added in various concentrations and cells were incubated for 24 or 48 h. The EC(50) values were obtained as half-maximum-effect concentrations from fitted curves. Following EC(50) values were found [BrdU: mean (mmol/l); SEM in parentheses; n=12]: (24 h/48 h) HEMA 8.860 (0.440)/6.600(0.630), TEGDMA 1.810(0.130)/1.220(0.130), UDMA 0.120(0.010)/0.140(0.010), BisGMA 0.060(0.004)/0.040(0.002), HgCl(2) 0.015(0.001)/0.050(0.006), and MeHgCl 0.004(0.001)/0.005(0.001). Following EC(50) values were found [LDH: mean (mmol/l); SEM in parentheses; n=12]: (24 h/48 h) HEMA 9.490(0.300)/7.890(1.230), TEGDMA 2.300(0.470)/1.950(0.310), UDMA 0.200(0.007)/0.100(0.007), BisGMA 0.070(0.005)/0.100(0.002), and MeHgCl 0.014(0.006)/0.010(0.003). In both assays, the following range of increased toxicity was found for composite components (24 and 48 h): HEMA < TEGDMA < UDMA < BisGMA. In both assays, MeHgCl was the most toxic substance. In the BrdU assay, Hg(2+) was about fourfold less toxic than MeHgCl but Hg(2+) was about fourfold more toxic than BisGMA. In the BrdU test, a significantly (P<0.05) decreased toxicity was observed for Hg(2+) at 48 h, compared to the 24 h Hg(2+)-exposure. A time depending decreased toxicity was observed only for Hg(2+) which can then reach the toxic level of BisGMA.

Bromodeoxyuridine↗

Identification of 2,3-epoxymethacrylic acid as an intermediate in the metabolism of dental materials in human liver microsomes.

OBJECTIVES: In previous studies it could be demonstrated that methacrylic acid (MA) is an intermediate in the metabolism of unpolymerized dental comonomers, released from dental restorative materials. This study was performed to identify the possible dental material intermediate 2,3-epoxymethacrylic acid (2,3-EMA) from MA in human liver microsomes. Most epoxy compounds are regarded as highly toxic substances. METHODS: The formation and hydrolysis were studied in defined systems containing only MA and human liver microsomes at 37 degrees C. Hydrolysis was inhibited by cyclohexene oxide, a competitive inhibitor of epoxide hydrolase. The reaction product 2,3-EMA was analyzed by the headspace gas chromatography-mass spectrometry. After 5, 30, and 60 min samples were taken and analyzed. RESULTS: For the reaction of MA to 2,3-EMA the average conversion rate was about 5% within 1h. It was found that without cyclohexene oxide the rate constant of enzymatic hydrolysis at pH 7.4 was about 10 times higher than the rate constant of the formation from MA in combination with cyclohexene oxide (k=8.3 versus 0.83 micromol/l min), indicating an instability and thus a high reactivity of 2,3-EMA. The formation of the MA intermediate 2,3-EMA was not observed when heat-inactivated liver microsomes were used (controls). SIGNIFICANCE: It could be clearly demonstrated that 2,3-EMA is a product of dental material metabolisms in biological systems. Therefore, increased toxicity might occur on dental restorative materials which are able to release (co)monomers which can be metabolized to MA.

Culture Techniques↗

Investigation of shear-peel bond strength of orthodontic brackets on enamel after using Pro Seal.

AIM: The aim of this investigation was to ascertain whether the use of a fluoride-releasing, light-curing sealant (Pro Seal, Reliance Orthodontic Products, Itasca, IL, USA) results in differences in shear-peel bond strength when teeth are etched via the conventional acid-etching method and with self-etching primers (SEP), respectively. We also examined whether Pro Seal functions as a substitute for the bonding agents recommended by the manufacturers. MATERIAL AND METHODS: To carry out this study, we randomly allocated 300 extracted molars (ISO 11405) into twelve groups (n=25). The brackets used (Victory Series, Twin UBi 0T/0A .022, 3M Unitek, Seefeld, Germany) were bonded using the same layer thickness of adhesive. The teeth were then stored for 24 h in de-ionized water (37 degrees C) and subsequently thermocycled. The brackets were debonded using a universal testing machine with a crosshead speed of 0.5 mm/min. For statistical evaluation we used the one-way analysis of variance (ANOVA [alpha = 0.05]) and the post hoc Tukey test and Weibull analysis. RESULTS: We could establish that the use of Pro Seal does not have a negative influence on shear-peel bond strength. When the compomer Assure was used, Pro Seal even led to an increase in shear-peel bond strength, especially when it was applied using the bonding agent recommended by the manufacturer. The highest Weibull modulus (m) was found for the self-etching primer IDEAL 1 without using Pro Seal (m=6.5) and the lowest for First Step SEP when using Pro Seal (m=2.2). There were also clear differences in characteristic shear-peel bond strength (sigma(0)) within some of the groups investigated. CONCLUSIONS: Although the statistical evaluation showed no significant negative influence on the shear-peel bond strength either when Pro Seal was used in addition, or when that fluoride-releasing, light-curing sealant was substituted for the bonding agent recommended by the manufacturer, the Weibull analysis showed that the use of Pro Seal in combination with SEP resulted in bond strength values that were less reliably reproducible.

Orthodontic Brackets↗

Effect of ozone on oral cells compared with established antimicrobials.

Ozone has been proposed as an alternative antiseptic agent in dentistry based on reports of its antimicrobial effects in both gaseous and aqueous forms. This study investigated whether gaseous ozone (4 x 10(6) microg m(-3)) and aqueous ozone (1.25-20 microg ml(-1)) exert any cytotoxic effects on human oral epithelial (BHY) cells and gingival fibroblast (HGF-1) cells compared with established antiseptics [chlorhexidine digluconate (CHX) 2%, 0.2%; sodium hypochlorite (NaOCl) 5.25%, 2.25%; hydrogen peroxide (H(2)O(2)) 3%], over a time of 1 min, and compared with the antibiotic, metronidazole, over 24 h. Cell counts, metabolic activity, Sp-1 binding, actin levels, and apoptosis were evaluated. Ozone gas was found to have toxic effects on both cell types. Essentially no cytotoxic signs were observed for aqueous ozone. CHX (2%, 0.2%) was highly toxic to BHY cells, and slightly (2%) and non-toxic (0.2%) to HGF-1 cells. NaOCl and H(2)O(2) resulted in markedly reduced cell viability (BHY, HGF-1), whereas metronidazole displayed mild toxicity only to BHY cells. Taken together, aqueous ozone revealed the highest level of biocompatibility of the tested antiseptics.

Analysis of Variance↗

Establishing quantitative light-induced fluorescence cut-offs for the detection of occlusal dentine lesions.

The aims of this in vitro study were, first, to define suitable cut-off values for the detection of occlusal dentine lesions by means of quantitative light-induced fluorescence (QLF), and, second, to compare the validity of light microscopy (LM) and microradiography (MR) as reference standards. Fifty-four third molar occlusal fissures with sound sites or non-cavitated lesions were examined. Standard QLF equipment was used to capture, display, store, and analyze fluorescence images. Each tooth was cut into sections in the bucco-lingual direction using a microtome saw, and the caries levels were subsequently assessed with the two reference methods. The histological examination with LM indicated that 46% of the specimens had carious lesions progressing into the dentine compared with 41% measured using MR (D3-4 level). Using optimal cut-off levels for the detection of dentine lesions, the sensitivity and specificity values were > 80%. The area under the receiver operating characteristic curve was slightly higher for MR (0.91-0.93) than for LM (0.88-0.89). The results of this study give a good idea of suitable cut-off points for the detection of occlusal dentine lesions using QLF. Owing to the small number of specimens in this study, further studies should be carried out before establishing definite cut-offs.

Area Under Curve↗

Silorane-based dental composite: behavior and abilities.

The purpose of this study was to examine the characteristics of an innovative composite material for dental restorations based on silorane--a monomer with a new chemical composition, and thereby compare the examined characteristics against those of well-known methacrylate-based composites. Degree of conversion at 2-mm and 6-mm depths as well as hardness, modulus of elasticity, and creep resistance through the middle of 6-mm high samples were measured. It was observed that up to 20 minutes after curing, curing time--and not irradiance--played the determinant role for a high degree of cure. No differences were registered between the two categories of material in terms of hardness. However, modulus of elasticity of the silorane-based material was slightly lower and the creep resistance higher than a methacrylate composite (Tetric EvoCeram). In conclusion, siloranes exhibited good mechanical properties comparable to those of clinically successful methacrylate-based composite materials.

Acrylic Resins↗

Cell death effects of resin-based dental material compounds and mercurials in human gingival fibroblasts.

In order to test the hypothesis that released dental restorative materials can reach toxic levels in human oral tissues, the cytotoxicities of the resin-based dental (co)monomers hydroxyethylmethacrylate (HEMA), triethyleneglycoldimethacrylate (TEGDMA), urethanedimethacrylate (UDMA), and bisglycidylmethacrylate (BisGMA) compared with methyl mercury chloride (MeHgCl) and the amalgam component mercuric chloride (HgCl2) were investigated on human gingival fibroblasts (HGF) using two different test systems: (1) the modified XTT-test and (2) the modified H 33342 staining assay. The HGF were exposed to various concentrations of the test-substances in all test systems for 24 h. All tested (co)monomers and mercury compounds significantly (P<0.05) decreased the formazan formation in the XTT-test. EC50 values in the XTT assay were obtained as half-maximum-effect concentrations from fitted curves. Following EC50 values were found (mean [mmol/l]; s.e.m. in parentheses; n=12; * significantly different to HEMA): HEMA 11.530 (0.600); TEGDMA* 3.460 (0.200); UDMA* 0.106 (0.005); BisGMA* 0.087 (0.001); HgCl2* 0.013 (0.001); MeHgCl* 0.005 (0.001). Following relative toxicities were found: HEMA 1; TEGDMA 3; UDMA 109; BisGMA 133; HgCl2 887; MeHgCl 2306. A significant (P<0.05) increase of the toxicity of (co)monomers and mercurials was found in the XTT-test in the following order: HEMA < TEGDMA < UDMA < BisGMA < HgCl2 < MeHgCl. TEGDMA and MeHgCl induced mainly apoptotic cell death. HEMA, UDMA, BisGMA, and HgCl2 induced mainly necrotic cell death. The results of this study indicate that resin composite components have a lower toxicity than mercury from amalgam in HGF. HEMA, BisGMA, UDMA, and HgCl2 induced mainly necrosis, but it is rather unlikely that eluted substances (solely) can reach concentrations, which might induce necrotic cell death in the human physiological situation, indicating that other (additional) factors may be involved in the induction of tissue (pulp) inflammation effects after dental restauration.

Apoptosis↗

Evaluation of micro-tensile bond strengths of composite materials in comparison to their polymerization shrinkage.

OBJECTIVE: The present study determined the influence of polymerization shrinkage of eight commercially available hybrid, micro-filled and nano composites (Z100 and Filtek Supreme, 3M-ESPE; Charisma and Durafill, Heraeus Kulzer; Tetric and InTen-S, Ivoclar Vivadent; Enamel plus HFO, GDF; Palfique Estelite Low Flow, Tokuyama) placed in large class 1 cavities on the bond strength to dentin. METHODS: Polymerization shrinkage was recorded for 300 s at room temperature with a Stress-Strain-Analyzer (C(FACTOR)=0.3). The maximum contraction stresses after 300 s, the time until gelation (t(0.5 N)) and the coefficient of near linear fit of contraction force/time (gradient) were analysed. For the evaluation of the micro-tensile-bond-strength (micro-TBS), hourglass shape samples obtained from a total of 32 no carious extracted human third and second molars, randomly divided into 8 groups, were used. Micro tensile bond strengths were determined by computing the ratio of maximum load by the adhesion area of the hourglass shape. In order to analyze the quality of the polymerization within fillings, hardness profiles of a surface cut thought the middle of the restored tooth and along the tooth axis were made. Further, the modulus of elasticity, determined in a three-point-bending test, as well as the variation of the modulus of elasticity and of the hardness within a filling were considered. The statistical analyses were conducted by ANOVA (alpha=0.05) and post-hoc Tukey's test. RESULTS: A significant correlation between polymerization shrinkage and micro-TBS was found (Pearson; -0.44). The correlation between modulus of elasticity in bending test and shrinkage stress (Pearson; 0.77), coefficient of near linear fit m (Pearson; 0.72), time until gelation (Pearson; -0.52) and micro-tensile-bond-strength (Pearson; -0.45) was also significant. A high polymerization tension and modulus of elasticity negatively affected the adhesion of the composite to the tooth hard substance. Further, the number of samples lost during the slice cutting and the hourglass shape preparation was found to correlate highly significantly with the shrinkage stress (Pearson; 0.97), coefficient of near linear fit m (Pearson; 0.94) and modulus of elasticity (Pearson; 0.82). All materials showed sufficient polymerization within the filling in comparison to the filling surface, the hardness at the bottom of the filling was greater than 80% of the maximum hardness value. The modulus of elasticity was not considerably reduced within the filling. SIGNIFICANCE: High contraction stress and modulus of elasticity, fast development of contraction force and an early start of stress build-up of materials placed in restrictive cavities cause tension in the material with a possible subsequent distortion of the bond to the tooth structure. A low modulus of elasticity is not necessarily associated with high bond strength. However, it causes a more uniform stress distribution at the restorative composite-tooth interface. This is also evident in a reduced sample loss during the different stages of sample preparation.

Analysis of Variance↗

Shrinkage behavior of a resin-based composite irradiated with modern curing units.

OBJECTIVE: The present study determined the influence of different light curing regimes (four light-emitting diode (LED) units (Freelight 1 and 2, 3M-ESPE; e-light, GC; Bluephase (prototype), Ivoclar Vivadent), two quartz-tungsten-halogen (QTH) lights (Astralis 10, Ivoclar Vivadent; Swiss Master Light, EMS) and one plasma-light curing unit (Easy Cure, DMDS)) on the curing behavior of a resin-based composite material (InTen-S, Ivoclar Vivadent). METHODS: Polymerization shrinkage was induced by light curing the tested material with 14 different regimes of the curing units mentioned above. The contraction stress was recorded for 300 s at room temperature with a Stress-Strain-Analyzer (c(FACTOR)=0.3). The maximum contraction stresses after 300 s, the time until gelation (t(0.5N)), and the coefficient of near linear fit of contraction force/time (gradient) were analyzed. The statistical analysis was conducted using ANOVA (alpha=0.05) and Tukey's post hoc test. RESULTS: The five tested regimes of the LED unit e-light revealed the lowest statistically significantly maximum contraction stress followed by the low intensity LED unit Freelight 1 and the plasma curing unit Easy Cure. The high intensity LED unit Freelight 2 exhibited a significantly higher contraction stress compared to Freelight 1. No significant differences between the standard and exponential modes within these curing units were found. No significant differences were found between the LED unit Freelight 2 and the pulse program of the halogen light curing unit Astralis 10. The highest polymerization stresses were observed for the high energy curing units, either QTH (Swiss Master Light and Astralis 10) or LED (Bluephase). SIGNIFICANCE: Fast contraction force development, high contraction stress and an early start of stress build-up cause tension in the material with possible subsequent distortion of the bond to the tooth structure. The lowest polymerization stress was observed for the low energy LED lamps, while the plasma unit and the high energy QTH and LED curing units produced two to three times higher stress.

Analysis of Variance↗

Biogeneric tooth: a new mathematical representation for tooth morphology in lower first molars.

A mathematical representation of tooth morphology may help to improve and automate restorative computer-aided design processes, virtual dental education, and parametric morphology. However, to date, no quantitative formulation has been identified for the description of dental features. The aim of this study was to establish and to validate a mathematical process for describing the morphology of first lower molars. Stone replicas of 170 caries-free first lower molars from young patients were measured three-dimensionally with a resolution of about 100,000 points. First, the average tooth was computed, which captures the common features of the molar's surface quantitatively. For this, the crucial step was to establish a dense point-to-point correspondence between all teeth. The algorithm did not involve any prior knowledge about teeth. In a second step, principal component analysis was carried out. Repeated for 3 different reference teeth, the procedure yielded average teeth that were nearly independent of the reference (less than +/- 40 microm). Additionally, the results indicate that only a few principal components determine a high percentage of the three-dimensional shape variability of first lower molars (e.g. the first five principal components describe 52% of the total variance, the first 10 principal components 72% and the first 20 principal components 83%). With the novel approach presented in this paper, surfaces of teeth can be described efficiently in terms of only a few parameters. This mathematical representation is called the 'biogeneric tooth'.

Algorithms↗

Curing behavior of a nanocomposite as a function of polymerization procedure.

The purpose of this study was to analyze the curing behavior of a nanocomposite by assessing in real time the degree of cure at depths of 2 mm and 6 mm. The variation of hardness with depth, shrinkage stress, and curing time until gelation with 16 curing regimes was further investigated using one halogen and three LED curing units. In the present study, it was shown that the soft-start polymerization concept is still valid, even with high-power LED curing units. A soft cure polymerization resulted in reduced shrinkage stress while simultaneously keeping the degree of cure and mechanical properties constant. For all tested curing unit types, a short polymerization duration (10 seconds) was insufficient to cure the nanocomposite in deeper layers--since the variation of hardness with depth showed a discontinuity between the layers, thus accounting for a decreased hardness of up to 30%.

Analysis of Variance↗

Longevity of occlusally-stressed restorations in posterior primary teeth.

PURPOSE: To compile a survey of the longevity and reasons for failure of stainless steel crowns, amalgam, glass-ionomer, composite and compomer restorations in stress-bearing cavities of primary molars. METHODS: This work reviewed the dental literature of 1971 up to July 2003 for longitudinal, controlled clinical studies and retrospective cross-sectional studies. Only studies investigating the clinical performance of restorations in primary teeth with an observation period of at least 2 years were included. Annual failure rates of stainless steel crowns, amalgam, glass-ionomer, composite and compomer restorations were determined and failure reasons were discussed. RESULTS: Annual failure rates in stress-bearing cavities of primary molars were determined to be: 0-14% for stainless steel crowns, 0-35.3% for amalgam restorations, 0-25.8% for glass-ionomer restorations, 2-29.1% for atraumatic restorative treatments, 0-15% for composite restorations, and 0-11 for compomer restorations. Main reasons for failure were secondary caries, marginal deficiencies, fracture, and wear.

Compomers↗

Effect of ozone on non-cavitated fissure carious lesions in permanent molars. A controlled prospective clinical study.

PURPOSE: To investigate, with a randomized controlled clinical study, the effect of ozone on non-cavitated initial occlusal fissure caries compared with untreated contra-lateral control lesions (split mouth) considering the patient's current caries risk. METHODS: Forty-one patients with 57 pairs of lesions were enrolled in the study (mean age 7.7 +/- 2.2 years; upper jaw n=29, lower jaw n=28). Gaseous ozone (HealOzone) was applied once for 40 seconds to the randomly assigned test molar of each pair without the use of remineralizing solutions. Lesion progression or reversal was monitored by the laser fluorescence system DIAGNOdent for up to 3 months and the deterioration or improvement compared between the ozone-treated lesions and the untreated control lesions (in pairs). This was done for the whole study population and a subgroup of patients with high current caries risk (lesion pairs n=26). RESULTS: After 3 months, explorative data analysis revealed that the ozone-treated lesions showed significantly more caries reversal or reduced caries progression than the untreated control lesions within the group of patients at high current caries risk (Wilcoxon-Test, P= 0.035). There was no statistical significance examining the whole study population. From the data it can be concluded that ozone application significantly improved non-cavitated initial fissure caries in patients at high caries risk over a 3-month period.

Adolescent↗

Restoration materials for primary molars-results from a European survey.

OBJECTIVE: The aim of this study was to obtain an overview of the materials and restorative techniques taught for Class I and Class II restorations in primary molars of different European departments for paediatric dentistry and to compare the results to those for North America. METHODS: The forms were sent to the chairmen of the departments of paediatric dentistry or-when included into the department for operative dentistry-to the director of 200 universities in 32 European Countries. The questions concerned the preferred materials and techniques, as well as the indications or contraindications for the use of the different tooth coloured materials. RESULTS: Forty-three percent of the universities from western European countries (excluding Germany) responded to the survey. A 97% answer rate was obtained from German Schools. Of the other European regions, the response rate varied remarkably (24-54%). Also, opinions on materials used and methods applied were different from country to country. Only in a few regions (Eastern Europe), amalgam remains the filling material of first choice for Class I and II cavities in primary molars, whereas in others, the use has been restricted and tooth coloured materials, especially compomers or resin-modified glass ionomer cements, are being preferred. CONCLUSIONS: Great diversity in teaching was observed not only among the European countries, but also within the countries themselves which makes it difficult to compare the results of our study to the ones obtained from the US.

Compomers↗

Ablation of temporomandibular joint structures of a pig with a fibre-guided 308 nm excimer laser light--an in vitro investigation.

PURPOSE: The present in vitro investigation was carried out to assess the efficacy of treatment with 308 nm excimer laser radiation applied to the structures of the temporomandibular joint of a pig. Laser parameters suitable to ensure adequate clinical efficiency with only minor thermal damage to the surrounding tissues were to be determined. MATERIAL AND METHODS: Tissue structures of the temporomandibular joint (cortical and cancellous bone, cartilage, disc and muscle) were extracted from freshly killed pigs and served as specimens. The specimens were embedded in polymethylmethacrylate. The laser light was applied after horizontal sectioning and measurement of thickness. The number of impulses that were necessary to perforate the specimen was counted and the rate of ablation determined. In addition, the irradiated surface was investigated histologically and the degree of tissue alteration was evaluated. RESULTS: The lowest energy threshold for ablation was found at an energy density of 0.8 J/cm2. Depending on the type of tissue, the maximum rate of ablation was evaluated as 1.7-6.3 microm/pulse. The depth of the thermal alteration to the surrounding tissue was about 30-70 microm. CONCLUSION: The guidable 308 nm excimer laser light offers a combination of precise tissue ablation with only minimal thermal damage to the surrounding tissue.

Animals↗

Genotoxicity and cytotoxicity of dental materials in human lymphocytes as assessed by the single cell microgel electrophoresis (comet) assay.

OBJECTIVES: Resin monomers may be released from restorative dental materials and can diffuse into the tooth pulp or the gingiva, and can reach the saliva and the circulating blood. Whereas the cytotoxic potential of some components has been clearly documented, possible genotoxicity in human target cells demands further investigation. METHODS: The Comet assay was used to quantify DNA single strand breaks, alkali labile and incomplete excision repair sites in lymphocytes of 10 volunteers. The xenobiotics investigated were 2-hydroxyethylmethacrylate (HEMA), triethyleneglycoldimethacrylate (TEGDMA), urethane dimethacrylate (UDMA), and bisphenol A-glycidyl methacrylate (Bis-GMA) with N-methyl-N'-nitro-N-nitrosoguanidine and dimethyl sulfoxide as controls. DNA migration was quantified using the tail moment according to Olive (OTM) and DNA migration was considered to be elevated at OTM levels above 2. Cytotoxicity was monitored using trypan blue. RESULTS: In the negative controls, OTM ranged between 1.0 and 1.2. With HEMA concentrations above 10(-6)M, TEGDMA 10(-3)M, Bis-GMA 10(-4)M, and UDMA above 10(-6)M relevant enhancements of DNA migration (OTM>2) were achieved. At higher concentrations of up to 2.5x10(-2) induced DNA migration was expressed by OTM of 3.3 for HEMA, 4.5 for TEGDMA, 7.4 for Bis-GMA, and 2.8 for UDMA. Relevant cytotoxic effects were also seen but vitality levels were at a critical range of 71% for Bis-GMA and 73% for TEGDMA, only. SIGNIFICANCE: In higher concentration levels, all tested substances induced significant but minor enhancement of DNA migration in the Comet assay as a possible sign for limited genotoxic effects. However, with the highest levels of DNA migration being combined with elevated cytotoxic effects, a low in vivo genotoxic strain appears to be posed by the resin components.

Adult↗