PubMed Health⌕ Search

Biomedical subjects

Reinhold Eckstein

Publications and source records attributed to Reinhold Eckstein.

At least 19 recordsLinked to original sources

Hepatitis B vaccination status among healthy adults in Germany.

OBJECTIVES: The hepatitis B vaccination policy in Germany was intensified by the implementation of hepatitis B vaccination for adolescents in the vaccination calendar in 1995. To investigate the effect of this measure on the hepatitis B vaccination coverage of healthy adults, we analysed the hepatitis B vaccination status of blood donors. Furthermore, the reasons for vaccination and the relationship between vaccination status and age, sex, and current profession were studied. METHOD: Using a standardised questionnaire, randomly incoming whole blood donors were asked for hepatitis B vaccination status, the reason for vaccination, gender, age and current profession. Multiple logistic regression analysis with vaccination status as dependent variable and age, gender and current profession as explanatory variables was performed. RESULTS: Overall, 1519 (22.3%) of the 6812 interviewed whole blood donors were vaccinated against hepatitis B. Younger age was significantly associated with higher acceptance of hepatitis B vaccination with already 44.1% of whole blood donors aged 18-29 years being hepatitis B immunised. Beside health care workers, teaching professions and students showed the highest hepatitis B vaccination rate. Foreign travel was nearly an equivalently important reason for hepatitis B vaccination as occupational risks. CONCLUSION: The high hepatitis B vaccination coverage among young and healthy adults indicates the success of the intensified hepatitis B vaccination policy since 1995. However, concentrating education measures on individuals with lower educational level and intensifying hepatitis B vaccination in the context of foreign travel could further increase the acceptance of hepatitis B vaccination.

Adolescent↗

The new generation of platelet additive solution for storage at 22 degrees C: development and current experience.

The storage of platelets (PLTs) in PLT additive solutions (PASs) might have several advantages. It can reduce allergic and febrile transfusion reactions, facilitate AB0-incompatible PLT transfusions, enable pathogen inactivation, and make more plasma available for other purposes (eg, for fractionation). For this reason, there has been considerable focus on the development of new PASs that assure maintenance of good PLT quality throughout storage. Several compounds in PASs such as citrate, acetate, phosphate, potassium, and magnesium have all turned out to be important, and the same applies to the necessary amount of glucose as determined by the plasma carryover. The latest generation of PASs, the modified PAS-III and Composol-PS, contains most or all of those compounds. Recently published data on the in vitro quality of either buffy coat- or apheresis-derived PLT concentrates stored in 70% or even 80% of PAS might encourage transfusion specialists to consider using these PASs in routine blood banking. However, because in vitro tests do not adequately predict clinical effectiveness of PLTs after transfusion, in vivo studies are still needed to assess the quality of PAS-stored PLTs.

Blood Platelets↗

CD 14+ cell collection in non-cytokine-stimulated donors with the COM.TEC cell separator.

BACKGROUND: The COM.TEC cell separator (Fresenius Hemocare), equipped with the MNC program (single-stage chamber) and the PBSC-LYM program (dual-stage chamber), was evaluated for CD 14+ cell collection regarding cell yields, collection efficiencies (CEs), and the content of residual cells in harvests. STUDY DESIGN AND METHODS: Twenty-four non-cytokine-stimulated donors underwent 5-L mononuclear cell (MNC) collections on the COM.TEC device to compare both programs. Two software versions (v02.03.05 vs. v 03.00.04) were investigated for optimization of the CD 14+ cell collection process. Blood counts of donors and products were analyzed for CD 14+ cells by flow cytometry and for platelets (PLTs), white blood cells, and red blood cells (RBCs) by a blood cell counter. RESULTS: In 5-L collections, the MNC program resulted in high CEs (83+/- 23%) and yields (1.2 x 10(9)+/- 0.6 x 10(9) per unit) of CD 14+ cells, but the products showed high residual PLTs. The use of a dual-stage chamber in the PBSC-LYM program produced a low content of residual PLTs (0.7 x 10(11) +/- 0.3 x 10(11) per unit) and RBCs but failed to reach a target of 1 x 10(9) CD 14+ cells. Modulated light to stabilize the buffy-coat detection by the interface monitor significantly improved CD 14+ cell enrichment. By use of the PBSC-LYM program, higher centrifuge velocity (1700 rpm [382 x g] vs. 1500 rpm [297 x g]) improved significantly CD 14+ cell yields (0.7 x 10(9) vs. 0.5 x 10(9) cells). CONCLUSION: A pure CD 14+ cell product with low numbers of residual cells was obtained by the PBSC-LYM program, which could be useful for good manufacturing practice-conformed production within closed systems. The MNC program offers the collection of high CD 14+ cell yields with excellent CEs but also high residual PLT counts.

Blood Donors↗

Washing platelets with new additive solutions: aspects on the in vitro quality after 48 hours of storage.

BACKGROUND: Rare clinical conditions cause the need for washed platelet (PLT) concentrates (PCs). Saline-washed PCs can only be stored shortly, however, owing to lack of substrates for PLT metabolism. New PLT additive solutions (PASs) contain such substrates and might be used alternatively. The in vitro quality of apheresis PCs washed with Composol-PS or modified PAS-III (PAS-IIIM) stored up to 48 hours after wash was compared. STUDY DESIGN AND METHODS: Twelve blood donors underwent two apheresis procedures (A and B) collecting 6.0 x 10(11) PLTs in 500 mL of plasma with a least 2 weeks in between. The PCs collected by Apheresis A were stored for 3 days and then split in two equal units before washing with Composol-PS or PAS-IIIM. The PCs collected by Apheresis B were split after collection. One unit was released for transfusion and 1 unit was stored unwashed up to Day 6 and used as reference unit. In vitro testing was performed before and after washing as well as 24 and 48 hours after wash. RESULTS: After 48 hours of postwash storage, the units washed with either PAS showed acceptable results for hypotonic shock response (HSR), P-selectin expression, and pH, whereas PLT aggregability was significantly impaired. Throughout the storage, unwashed units showed better in vitro quality. HSR and P-selectin expression were similar before and immediately after the washing procedure. CONCLUSION: Based on these in vitro results, 48-hour postwash storage of washed PCs with the two PASs seems to be feasible. In vivo recovery studies, however, must confirm this finding in the future.

Blood Platelets↗

Platelet function in variable platelet split products intended for neonatal transfusion.

BACKGROUND: Only a few systematic studies have examined the effect of variable produced small platelet (PLT) aliquots on PLT function before transfusion to neonates. Although neonatal transfusion could be critical, no standardization of production or systematic quality controls have been introduced so far. STUDY DESIGN AND METHODS: PLT split products were prepared in three different ways (30- or 60-mL bag, syringe aliquot) at different times from the parent unit (Days 1-4) and stored for 2 or 4 hours. The measures of PLT function include pH, lactate, P-selectin expression, and cytokines (beta-thromboglobulin [beta-TG], PLT-derived growth factor AB [PDGF-AB]). Additionally, syringe passage (0.5 mL/min) was assessed. RESULTS: High product variability of PLT content was found (40% deviation of PLT content from programmed target, 13%-19% PLT loss by product distribution), which resulted in PLT concentrations of split units between 0.94 x 10(9) and 1.66 x 10(9) PLTs per mL. Different gas transfer rates (pCO2) of PLT containers caused different pH values of the product (Trima 7.47 +/- 0.09 vs. COM.TEC 7.33 +/- 0.08; p < 0.0001), but acceptable results of PLT metabolism were found in all split units (minimum pH, 7.09; maximum lactate content, 13.1 mmol/L). P-selectin expression on PLTs increased by factor of 2 in the parent units stored for 4 days (16.9 +/- 8.6% 32.2 +/- 13.4%; p = 0.02). After Day 3, beta-TG and PDGF-AB increased by twofold. PLTs stored during passage for 100 minutes in syringes dropped pO(2) by 50 percent and caused 15 percent higher lactate levels. CONCLUSION: High variability of PLT content in split units requires at least additional PLT counts before transfusion in critical preterm or neonatal infants.

Adult↗

A pilot study of continuous ambulatory monitoring of blood pressure in repeated preoperative autologous blood donation.

BACKGROUND: The aim of this study was to investigate the occurrence of hypotension in the 24-hour period after preoperative autologous blood donation (PABD) in patients with and without hypertension. STUDY DESIGN AND METHODS: In 20 patients, 24-hour ambulatory blood pressure monitoring (ABPM) was performed before PABD was started and on every donation day in two repeated phlebotomies. RESULTS: Seven patients had no hypertension and 11 patients had hypertension. In 2 additional patients, hypertension was diagnosed during the study. Overall, the mean systolic BP (SBP) decreased from 131+/-15 mmHg before donation to 128+/-13 and 127+/-10 mmHg after Donations 1 and 2; the corresponding values for the diastolic BP (DBP) were 77+/-9, 75+/-9, and 73+/-7 mmHg, both without significant differences between the groups with and without hypertension. In single patients, substantial decreases of BP occurred, especially during the night. Two patients with and 2 without hypertension showed a nightly decrease in SBP and DBP of more than 10 percent (in 1 of these patients, more than 20%). Concerning diurnal BP variability, 1 patient with and 1 without hypertension, the latter showing a nightly decrease of SBP and DBP of more than 10 percent, also changed to the pattern of a nightly "extreme dipper" after PABD. CONCLUSION: In 25 percent of the patients, changes of BP were observed during the 24-hour period after PABD, especially during the night, which are known to be associated with an increased risk of cerebral or myocardial ischemia. Whether those changes of BP lead to major morbidity or mortality requires further investigation.

Adult↗

Impact of different hold time before addition of platelet additive solution on the in vitro quality of apheresis platelets.

BACKGROUND: The quality of platelets (PLTs) stored in PLT additive solution (PAS) is dependent on the type and proportion of the used PAS. No data are available as to whether a different hold time before the addition of PAS to hyperconcentrated PLT suspensions has an impact on PLT quality. The in vitro quality between single-donor PLT concentrates was compared with two different hold times with two PASs. STUDY DESIGN AND METHODS: On two occasions, 6x10(11) PLTs in 150 mL of plasma were collected from 20 blood donors. The units were split into two equal parts, and 140 mL of PAS-II or PAS-IIIM (randomized sequence) was added after 2 or 8 hours resulting in a PAS proportion of 65 percent. On Days 1, 5, and 7, glucose and lactate concentration, pH value, PLTs' P-selectin expression, response to hypotonic shock, and release of transforming growth factor-beta1 were determined. RESULTS: On all days, the lactate concentrations were higher and pH values were lower in units with an 8-hour hold time, whereas the results of in vitro tests relating to the in vivo viability and activation of PLTs were similar for both groups. PAS-IIIM-stored PLTs showed a lower glycolytic activity and better results in all performed in vitro tests than PAS-II-stored PLTs. CONCLUSIONS: Although the metabolism of glucose was enhanced during hold time, the differences between both hold time groups are not meaningful from a biological viewpoint. Therefore, an 8-hour hold time is feasible. PLT storage in PAS-IIIM results in a PLT in vitro quality superior to that of PLTs stored in PAS-II.

Blood Platelets↗

Di(2-ethylhexyl)phthalate (DEHP) exposure of voluntary plasma and platelet donors.

Each year thousands of healthy volunteers undergo apheresis procedures to donate blood components and safe lives. However, many disposables used in apheresis contain di(2-ethylhexyl)phthalate (DEHP). This way, donors are exposed to DEHP, which is a reproductive and developmental toxicant in animals and a suspected endocrine modulator in humans. We quantified the DEHP exposure of six plasma donors, six discontinuous-flow platelet donors and six continuous-flow platelet donors by determining three specific metabolites in urine (5OH-MEHP: mono(2-ethyl-5-hydroxyhexyl)phthalate; 5oxo-MEHP: mono(2-ethyl-5-oxo-hexyl)phthalate and MEHP: mono(2-ethylhexyl)phthalate). We found maximum concentrations in urine samples after the discontinuous-flow plateletpheresis procedure with 826 microg/l for 5OH-MEHP, 774 microg/l for 5oxo-MEHP and 266 microg/l for MEHP (mean of the six volunteers). Metabolite excretions were found to be significantly (p<0.0001) higher for both plateletpheresis techniques compared to plasmapheresis and controls. Continuous-flow plateletpheresis led to significantly higher (p<0.0001) excretions than discontinuous-flow plateletpheresis. Mean absolute DEHP exposures were 1.2 mg for discontinuous- and 2.1 mg for continuous-flow plateletpheresis. Exposure for plasmapheresis (0.37 mg) was in the range of the controls (0.41 mg). Mean DEHP doses for both plateletpheresis techniques (18.1 and 32.3 microg/kg/day) were close to or exceeded the reference dose (RfD) of the US EPA and tolerable daily intake (TDI) value of the EU on the day of the apheresis. Therefore, margins of safety might be insufficient to protect especially young men and women in their reproductive age from effects on reproductivity. At present, discontinuous-flow devices should be preferred to avert conceivable health risks from plateletpheresis donors. Strategies to avoid DEHP exposure of donors during apheresis need to be developed.

Adult↗

Intravenous exposure to di(2-ethylhexyl)phthalate (DEHP): metabolites of DEHP in urine after a voluntary platelet donation.

In this study we investigated human metabolism and excretion of DEHP after intravenous exposure. For this purpose we determined the five major DEHP metabolites in urine samples of a volunteer before and after a platelet donation (dual-needle technique). Plateletpheresis procedures are known to cause a significant DEHP exposure. We observed a sharp increase in urinary DEHP metabolite concentrations after the procedure. Maximum concentrations of 5OH-MEHP, 5oxo-MEHP, 5cx-MEPP and MEHP observed 4 h after the procedure were 822, 729, 577 and 388 microg/l respectively. 2cx-MMHP was excreted at highest concentrations after 8 h (201 microg/l). Due to longer elimination half-times, 5cx-MEPP and 2cx-MMHP were the major metabolites excreted in urine 24 h after the exposure. The 24-h-cumulative excretion of 363 microg 5cx-MEPP, 353 microg 5OH-MEHP, 309 microg 5oxo-MEHP, 178 microg MEHP and 133 microg 2cx-MMHP indicates an absolute exposure of our volunteer of about 2.6 mg DEHP. Related to the body weight this equals a dose of 31.6 microg/kg body weight/day. This indicates that current risk or preventive limit values for DEHP such as the RfD of the US EPA (20 microg/kg/day) and the TDI of the European Union (20-48 microg/kg/day) can be exceeded on the day of the plateletpheresis. The amount of the dose excreted in urine, distribution of the metabolites in urine and all other elimination characteristics after intravenous DEHP exposure are comparable to oral exposure. There are no indications that toxicokinetic behaviour and the toxicity of DEHP are fundamentally different after the two routes of exposure. Therefore, toxicological endpoints observed for DEHP after oral application should also be considered relevant for medical procedures causing intravenous DEHP exposure, like apheresis procedures. Especially women in their reproductive age need to be protected from DEHP exposures exceeding the above mentioned preventive limit values.

Adult↗

Mononuclear cell variability and recruitment in non-cytokine-stimulated donors after serial 10-liter leukapheresis procedures.

BACKGROUND: We introduced monitoring of mononuclear cell (MNC) counts to obtain enhanced donor control and a stable quality of MNC products, because there are limited data available about blood donors after serial leukapheresis (LP) procedures. STUDY DESIGN AND METHODS: In a prospective paired study, 13 male healthy blood donors underwent 10-L LP procedures performed on two apheresis devices by use of two MNC program settings (COBE Spectra, Gambro BCT, SF 250 vs. SF 500; and AS.TEC 204, Fresenius Hemocare, CP 129 vs. CP 194). Donors' pre- and postdonation MNC counts were analyzed by fluorescence-activated cell sorting. RESULTS: After each 10-L LP procedure, a transient decline (p < 0.05) of CD14+ monocyte and platelet counts appeared in donors. Loss of donors' CD3+ T cells, CD19+ B cells, and CD16+56+ natural killer (NK) cells during MNC collection was partly compensated by cell recruitment. The MNC recruitment factor (RF) seems to be higher with high-yield MNC program settings. Negative correlations (p < 0.01) were noticed between predonation counts and RFs of CD3+ T cells and CD16+56+ NK cells. Four serial 10-L LP procedures did not result in long lasting MNC depletion for donors. CONCLUSION: MNC recruitment seems to depend on MNC program settings and collected cell yields. Low MNC counts could result in high cell recruitment that may contribute to stable collection results to some degree. Nevertheless, there seems to be a considerable individual variation of MNC recruitment in donors that should be investigated in more detail.

Adult↗

Plateletpheresis does not cause long-standing platelet-derived growth factor release into the donor blood.

BACKGROUND: Recently, long-standing elevations of soluble growth factors released from platelets (PLTs) after contact with artificial surfaces during dialysis were described. They could be jointly responsible for the high frequency of death from cardiovascular diseases in dialysis patients. There are no comparable data on the extent and the duration of a growth factor release by plateletpheresis procedures. STUDY DESIGN AND METHODS: A total of 37 plateletpheresis procedures were performed with two different devices. PLT-derived growth factor (PDGF) isoform AB, transforming growth factor (TGF)-beta1, and beta-thromboglobulin (beta-TG) were measured in the donors' plasma samples, and PLT activation and function were measured by cytometry and aggregometry before and after plateletpheresis and 1 and 24 hours later. RESULTS: Before apheresis, the following mean plasma levels were found: beta-TG, 98.6 +/- 37.3 IU per mL; PDGF-AB, 71.5 +/- 38.5 pg per mL; and TGF-beta1, 2.24 +/- 0.80 ng per mL. At the end of the apheresis procedures, the mean PDGF-AB level had increased by a factor of 1.8 (p < 0.05). One hour later, the mean PDGF-AB level had normalized again. No significant change in the levels of beta-TG and TGF-beta1 was found by the apheresis procedures. There was no influence of the blood cell separator type on the results. CONCLUSION: Only a slight and rapidly reversible increase in soluble PDGF-AB was found during plateletpheresis and no increase in soluble TGF-beta1 and beta-TG was found. This change should not be harmful to the donor.

Blood Donors↗

Frequently used plateletpheresis techniques result in variable target yields and platelet recruitment of donors.

BACKGROUND: Standard plateletpheresis techniques and effects on platelet (PLT) donors were investigated to provide an informative basis for advancement of apheresis software. STUDY DESIGN AND METHODS: Three paired groups with 33 male and 22 female blood donors were prospectively investigated by analyzing blood counts of donors and products. Four apheresis platforms, the COBE Spectra LRS and the Trima v4 (Gambro BCT) and the AS.TEC204 and the COM.TEC (Fresenius Hemocare), were compared. Deviations of the collected from programmed PLT targets and donor PLT recruitment were calculated for single-unit PLT concentrates (SU-PCs; 3 x 10(11) PLTs) and double-unit PLT concentrates (DU-PCs; 6 x 10(11) PLTs). RESULTS: Regarding SU-PCs, the productivity of the COM.TEC machine was superior to the AS.TEC204 machine, because of shorter processing time (54 min vs. 67 min) and higher yields (2.90 x 10(11) PLTs vs. 2.75 x 10(11) PLTs). Compared to the Spectra machine, the Trima v4 machine showed higher collection efficiencies (CEs) and shorter processing time and complied better with the programmed target (SU-PCs, 3.24 x 10(11) PLTs vs. 3.70 x 10(11) PLTs; DU-PCs, 6.87 x 10(11) PLTs vs. 7.56 x 10(11) PLTs). Harvests of the Spectra machine (DU-PCs) exceeded the target by 40 percent, which resulted in high PLT loss for donors. A longer processing time resulted in some higher CEs (SU-PCs, 53%; DU-PCs, 58%), which could contribute to this result. PLT recruitment compensated PLT loss to some extent. CONCLUSION: The major finding was that the newer devices (COM.TEC and Trima) gave more predictable yields than the older devices (AS.TEC204 and Spectra) and resulted in lower PLT deficit. PLT software should be improved to minimize relevant variations of collected yields regarding the programmed target.

Adult↗

Comparison of two mononuclear cell program settings on two apheresis devices intended to collect high yields of CD14+ and CD3+ cells.

BACKGROUND: In cancer and transplantation therapy apheresis devices and software of optimum standards are required for the collection of high cell yields with high purity of the desired cell fraction. STUDY DESIGN AND METHODS: In a paired study, 15 healthy blood donors underwent four 10-L leukapheresis procedures (197 +/- 33 min) with an inlet blood flow rate of 60 mL per minute by use of two different MNC program settings of the COBE Spectra (Gambro BCT) and the AS.TEC 204 (Fresenius Hemocare) cell separators. RESULTS: Use of the standard MNC program of both apheresis devices resulted in significantly higher (p < 0.01) collection efficiencies of CD14+ monocytes, CD3+ cells, CD4+ cells, CD8+ T cells, CD16+ CD56+ natural killer (NK) cells, and residual PLTs (p < 0.001), owing to higher centrifuge speed. The mean MNC purity of all components was more than 90 percent. By use of standard programs of either device, significant correlations (p < 0.01) between donor monocytes and preleukapheresis NK cell counts and the corresponding component cell yields were found. CONCLUSION: Compared to the program modifications with lower centrifuge velocities the standard MNC programs were significantly more efficient regarding CD14+, CD3+, and CD16+ CD56+ cells. Enhanced centrifuge speed and inlet blood flow rate in MNC programs resulted in higher, similar composed MNC concentrations of the products.

Adult↗