Ultrasound is not the only technique to visualize third occipital nerve blockade.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Reinhold Schatzer.
Explore the source record for details and available documents.
Forestier's disease is a systemic rheumatologic abnormality of unknown etiology, characterized by a flowing ossification of the anterior ligament of the spine. In this case study we report on an atypical appearance of Forestier's disease in a 72-year-old woman. This patient had a one-month history of rapidly progressing dysphonia and dyspnea and at the time of admission was unable to eat. She had been operated for gastric and colon carcinoma seventeen months earlier. Total body CT scans showed a flowing ossification of the anterior ligament between levels C2 and C7 and an osteophyte protruding in the ventral direction at level C2. Before the osteophyte's removal, a tumor screening was conducted to exclude the presence of distant metastases or occult malignancy. Resection of the large osteophyte was performed via a typical ventral-cervical approach with horizontal skin incision. Six months after the procedure, the patient experienced distinct improvement of her condition and was able to eat both pulpy and solid foods again. In this case example, a rapidly progressive dysphagia was not caused by secondary malignancy, as initially speculated, but resulted from a ventral-cervical osteophyte, considered a rare cause for acute development of severe dysphagia. Early diagnosis of Forestier's disease in this patient led to immediate surgical intervention, which proved to be adequate treatment and enabled the patient to make a good recovery.
Two new approaches to the design of speech processors for cochlear implants are described. The first aims to represent "fine structure" or "fine frequency" information in a way that it can be perceived and used by patients, and the second aims to provide a closer mimicking than was previously possible of the signal processing that occurs in the normal cochlea.
UNLABELLED: We conducted this study to develop an ultrasound-guided approach for facet joint injections of the lumbar spine. Five zygapophyseal joints (L1-S1) on each side of 5 embalmed cadavers were examined by ultrasound for a total of 50 examinations. The joint space was demonstrated under ultrasound guidance. The midpoint of the joint space, defined as the middle of its cranio-caudal extension on its dorsal surface, was taken as a reference point, and its position was computed from its depth and lateral distance from the spinous process. Forty-two of 50 approaches could be clearly visualized. Subsequently, these distances were compared to those obtained by computed tomography (CT). To assess the efficacy of ultrasound in the needle placement, all lumbar facet joints were approached in one embalmed cadaver. The exact placement of the needle tips was again evaluated by CT. Ultrasound and CT measurements showed the same mean depth and lateral distance to the reference point, 3.15 +/- 0.5 cm and 1.9 +/- 0.6 cm, respectively. Pearson's coefficient of correlation was 0.86 (P < 0.0001) between ultrasound and CT. All 10 needle tips were within the joint space during simulated facet joint injections. We conclude that ultrasound guidance might be a useful adjunct for facet joint injections in the lumbar spine. IMPLICATIONS: This study was designed to develop an ultrasound-guided approach to the facet joints of the lumbar spine and to assess its feasibility and accuracy by means of a comparison to computed tomography images. The imaging study demonstrated a significant correlation between ultrasound and computed tomography measurements. During simulated facet injection, ultrasound guidance consistently resulted in accurate needle placement.
OBJECTIVE: We conducted this study to develop a sonographically guided approach to the spinal nerve of the lumbar spine and to assess its feasibility and accuracy by means of computed tomography (CT). METHODS: Fifty sonographically guided approaches at 5 levels (L1-S1) were performed on 5 embalmed cadavers, which were positioned prone. The spinal nerves of the lumbar spine were shown under sonographic guidance. In 1 cadaver, the most lateral aspect of the roof of the intervertebral foramen was defined as a reference point. Its position was computed as a distance from the tip of the spinal process (A), the midline (B), and the intervertebral disk (C). Subsequently, axial transverse CT scans were made to verify these distances. In a second part of the experiment, a spinal needle was advanced under sonographic guidance to the spinal nerves for each lumbar spinal level on 1 embalmed cadaver. The exact placement of the needle tips was checked with the help of CT. RESULTS: This technique for a sonographically guided approach to the periradicular area proved to be feasible and accurate. Sonography and CT provided the same mean measurements of 4.0, 2.5, and 1.4 cm for distances A, B, and C, respectively. The Pearson correlation coefficient was 0.99 (P < .001) between sonography and CT. In the experimental study, all 10 needle tips were placed periradicular to the spinal nerves. CONCLUSIONS: Sonographic guidance is a useful adjunct to increase the safety and efficacy of periradicular injections in the lumbar spine.
BACKGROUND AND OBJECTIVES: The objective of this study was to show the efficacy of ultrasound in facilitating the performance of a simulated cervical periradicular injection in cadavers. METHODS: A total of 40 ultrasound-guided examinations at 4 levels (C3 to C7) were performed on 4 embalmed cadavers. The cervical spinal nerves were located with ultrasound. First, the transverse process of each level was taken as a sonoanatomic landmark. The most lateral aspect of the transverse process of the seventh cervical vertebra was then established as the reference point. Ipsilateral distances (A, B, C, and D) between this point and each one of the transverse processes of the cervical spine up to the third vertebra were then computed. Subsequently, coronal computed tomography (CT) scans were taken to verify these distances. In a second part, a spinal needle was advanced under ultrasound guidance to the spinal nerves C5 to C8 on both sides of one cadaver. The exact placement of the needle tips was checked by CT. RESULTS: The transverse processes were identified in all cadavers. In 5 attempts, a depiction of the spinal nerves was not possible. Ultrasound and CT provided the same mean measurements of 1.1 cm, 2.1 cm, 3.1 cm, and 4.1 cm for distances A, B, C, and D, respectively. All 8 needle tips were placed within 5 mm dorsal to the spinal nerve and less than 5 mm away from the posterior tubercle of each level's transverse process, as also verified by CT. CONCLUSIONS: This preclinical study suggests that ultrasound is a useful guiding tool for periradicular injections in the cervical spine.
OBJECTIVES: The aim of this study was to investigate the efficacy of ultrasound as a guiding tool for simulated cervical facet joint injections in cadavers. METHODS: A total of 40 ultrasound examinations at 5 levels (C6-7 to C2-3) were performed on 4 embalmed cadavers. The zygapophyseal joints were located with ultrasound. First, the transverse processes of C6 and C7 were established and the facet joint of C6-7 was demonstrated. The midpoint of this joint space, defined as the middle of its cranio-caudal extension on its lateral surface, was taken as a reference point. Ipsilateral distances (A, B, C, and D) between this point and each one of the 4 facet joints of the cervical spine up to the facet joints C2-3 were then computed. Subsequently, coronal computed tomography (CT) scans were taken to verify these distances. In a second experiment, a spinal needle was advanced under ultrasound guidance to the zygapophyseal joints from C2-3 to C6-7 on both sides of 1 cadaver. The exact placement of the needle tips was again verified by CT. RESULTS: In 4 attempts, a depiction of the joint space was not possible. Ultrasound and CT provided the same mean measurements of 1.2+/-0.2 cm, 2.0+/-0.3 cm, 3.0+/-0.2, and 4.0+/-0.5 cm for distances A, B, C, and D, respectively. All 10 needle tips were located in the joint space during simulated facet joint injections, as also verified by CT. DISCUSSION: This preclinical study suggests that ultrasound is a useful guiding tool for facet joint injections in the cervical spine.