PubMed Health⌕ Search

Biomedical subjects

Reinhold Scherer

Publications and source records attributed to Reinhold Scherer.

10 recordsLinked to original sources

Study of discriminant analysis applied to motor imagery bipolar data.

We present a study of linear, quadratic and regularized discriminant analysis (RDA) applied to motor imagery data of three subjects. The aim of the work was to find out which classifier can separate better these two-class motor imagery data: linear, quadratic or some function in between the linear and quadratic solutions. Discriminant analysis methods were tested with two different feature extraction techniques, adaptive autoregressive parameters and logarithmic band power estimates, which are commonly used in brain-computer interface research. Differences in classification accuracy of the classifiers were found when using different amounts of data; if a small amount was available, the best classifier was linear discriminant analysis (LDA) and if enough data were available all three classifiers performed very similar. This suggests that the effort needed to find regularizing parameters for RDA can be avoided by using LDA.

Brain↗

Motor imagery and EEG-based control of spelling devices and neuroprostheses.

A brain-computer interface (BCI) transforms signals originating from the human brain into commands that can control devices or applications. With this, a BCI provides a new non-muscular communication channel, which can be used to assist patients who have highly compromised motor functions. The Graz-BCI uses motor imagery and associated oscillatory EEG signals from the sensorimotor cortex for device control. As a result of research in the past 15 years, the classification of ERD/ERS patterns in single EEG trials during motor execution and motor imagery forms the basis of this sensorimotor-rhythm controlled BCI. The major frequency bands of cortical oscillations considered here are the 8-13 and 15-30 Hz bands. This chapter describes the basic methods used in Graz-BCI research and outlines possible clinical applications.

Communication Devices for People with Disabilities↗

Online control of a brain-computer interface using phase synchronization.

Currently, almost all brain-computer interfaces (BCIs) ignore the relationship between phases of electroencephalographic signals detected from different recording sites (i.e., electrodes). The vast majority of BCI systems rely on feature vectors derived from e.g., bandpower or univariate adaptive autoregressive (AAR) parameters. However, ample evidence suggests that additional information is obtained by quantifying the relationship between signals of single electrodes, which might provide innovative features for future BCI systems. This paper investigates one method to extract the degree of phase synchronization between two electroencephalogram (EEG) signals by calculating the so-called phase locking value (PLV). In our offline study, several PLV-based features were acquired and the optimal feature set was selected for each subject individually by a feature selection algorithm. The online sessions with three trained subjects revealed that all subjects were able to control three mental states (motor imagery of left hand, right hand, and foot, respectively) with single-trial accuracies between 60% and 66.7% (33% would be expected by chance) throughout the whole session.

Adolescent↗

Steady-state somatosensory evoked potentials: suitable brain signals for brain-computer interfaces?

One of the main issues in designing a brain-computer interface (BCI) is to find brain patterns, which could easily be detected. One of these pattern is the steady-state evoked potential (SSEP). SSEPs induced through the visual sense have already been used for brain-computer communication. In this work, a BCI system is introduced based on steady-state somatosensory evoked potentials (SSSEPs). Transducers have been used for the stimulation of both index fingers using tactile stimulation in the "resonance"-like frequency range of the somatosensory system. Four subjects participated in the experiments and were trained to modulate induced SSSEPs. Two of them learned to modify the patterns in order to set up a BCI with an accuracy of between 70% and 80%. Results presented in this work give evidence that it is possible to set up a BCI which is based on SSSEPs.

Adult↗

BCI meeting 2005--workshop on technology: hardware and software.

This paper describes the outcome of discussions held during the Third International BCI Meeting at a workshop to review and evaluate the current state of BCI-related hardware and software. Technical requirements and current technologies, standardization procedures and future trends are covered. The main conclusion was recognition of the need to focus technical requirements on the users' needs and the need for consistent standards in BCI research.

Algorithms↗

Brain-computer interfaces for control of neuroprostheses: from synchronous to asynchronous mode of operation.

Transferring a brain-computer interface (BCI) from the laboratory environment into real world applications is directly related to the problem of identifying user intentions from brain signals without any additional information in real time. From the perspective of signal processing, the BCI has to have an uncued or asynchronous design. Based on the results of two clinical applications, where 'thought' control of neuroprostheses based on movement imagery in tetraplegic patients with a high spinal cord injury has been established, the general steps from a synchronous or cue-guided BCI to an internally driven asynchronous brain-switch are discussed. The future potential of BCI methods for various control purposes, especially for functional rehabilitation of tetraplegics using neuroprosthetics, is outlined.

Adult↗

Steady-state visual evoked potential (SSVEP)-based communication: impact of harmonic frequency components.

Brain-computer interfaces (BCIs) can be realized on the basis of steady-state evoked potentials (SSEPs). These types of brain signals resulting from repetitive stimulation have the same fundamental frequency as the stimulation but also include higher harmonics. This study investigated how the classification accuracy of a 4-class BCI system can be improved by incorporating visually evoked harmonic oscillations. The current study revealed that the use of three SSVEP harmonics yielded a significantly higher classification accuracy than was the case for one or two harmonics. During feedback experiments, the five subjects investigated reached a classification accuracy between 42.5% and 94.4%.

Adult↗

Imagery of motor actions: differential effects of kinesthetic and visual-motor mode of imagery in single-trial EEG.

Single-trial motor imagery classification is an integral part of a number of brain-computer interface (BCI) systems. The possible significance of the kind of imagery, involving rather kinesthetic or visual representations of actions, was addressed using the following experimental conditions: kinesthetic motor imagery (MIK), visual-motor imagery (MIV), motor execution (ME) and observation of movement (OOM). Based on multi-channel EEG recordings in 14 right-handed participants, we applied a learning classifier, the distinction sensitive learning vector quantization (DSLVQ) to identify relevant features (i.e., frequency bands, electrode sites) for recognition of the respective mental states. For ME and OOM, the overall classification accuracies were about 80%. The rates obtained for MIK (67%) were better than the results of MIV (56%). Moreover, the focus of activity during kinesthetic imagery was found close to the sensorimotor hand area, whereas visual-motor imagery did not reveal a clear spatial pattern. Consequently, to improve motor-imagery-based BCI control, user training should emphasize kinesthetic experiences instead of visual representations of actions.

Adolescent↗

EEG-based neuroprosthesis control: a step towards clinical practice.

This case study demonstrates the coupling of an electroencephalogram (EEG)-based Brain-Computer Interface (BCI) with an implanted neuroprosthesis (Freehand system). Because the patient was available for only 3 days, the goal was to demonstrate the possibility of a patient gaining control over the motor imagery-based Graz BCI system within a very short training period. By applying himself to an organized and coordinated training procedure, the patient was able to generate distinctive EEG-patterns by the imagination of movements of his paralyzed left hand. These patterns consisted of power decreases in specific frequency bands that could be classified by the BCI. The output signal of the BCI emulated the shoulder joystick usually used, and by consecutive imaginations the patient was able to switch between different grasp phases of the lateral grasp that the Freehand system provided. By performing a part of the grasp-release test, the patient was able to move a simple object from one place to another. The results presented in this work give evidence that Brain-Computer Interfaces are an option for the control of neuroprostheses in patients with high spinal cord lesions. The fact that the user learned to control the BCI in a comparatively short time indicates that this method may also be an alternative approach for clinical purposes.

Adult↗

An asynchronously controlled EEG-based virtual keyboard: improvement of the spelling rate.

An improvement of the information transfer rate of brain-computer communication is necessary for the creation of more powerful and convenient applications. This paper presents an asynchronously controlled three-class brain-computer interface-based spelling device [virtual keyboard (VK)], operated by spontaneous electroencephalogram and modulated by motor imagery. Of the first results of three able-bodied subjects operating the VK, two were successful, showing an improvement of the spelling rate sigma, the number of correctly spelled letters/min, up to sigma = 3.38 (average sigma = 1.99).

Algorithms↗